ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: 5x20 Fuse Product #: 215xxxXEP Issue Date: April 13, 2013 It is hereby certified by Littelfuse, Inc. that there is neither RoHS (EU Directive 2002/95/EC, 2011/65/EU)-restricted substance nor such use, for materials to be used for unit parts, for packing/packaging materials, and for additives and the like in the manufacturing processes. In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing processes, are all composed of the following components. Issued by: <Global EHS Specialist > (1) Parts, sub-materials and unit parts This document covers the 5x20 Fuse RoHS-Compliant series products manufactured by Littelfuse, Inc. < Raw Materials Used Please see Table 1 (2) The ICP data on all measurable substances Please see appropriate pages as identifed in Table 1 Remarks: Form 585-047 Rev. A 1 2/21/06 Table 1: List of Raw Materials covered by this report Total Parts 2 Raw Material Part Number 030204, 934-077, C030210, 934-079 C910510, 910-555 (replaced 910-553) 3 4 5 910-556 692529 692539-002 Cap Solder Solder 6 909532/ 909-449 Body 7 11-0595 (082xxx-001) 57-61 8 9 082xxx-001 0042xx Ag-Cu Sn Plated (687xxx-001) Element – Cu99.9MSn(082xxx) Tin plated Wire 10 11 12 12 648118 648901 195116 087355 Yarn – GLZZXXX-6481XX Yarn Flux_Chlorinated Glue 72-78 79-85 86-98 99-102 13 091250/ 091251 Sand 103-109 1 Raw Material Description Page(s) Overcap 3-6 Cap 7-10 11-17 18-22 23-27 28-56 Rating(s) All Amps 2 62-65 66-71 0.125-0.8Amps & 1-6.3Amps 8,10-16, 20 & 25Amps 0.125-0.8Amps 1-25Amps 0.125-0.8Amps/ 1-25Amps 0.125-0.250/ 4-12Amps 0.315-0.8, 15, 16, 20 & 25Amps 1-3.15Amps 0.125 & 0.160Amps 0.2-0.8Amps 0.2-0.8Amps 0.125-0.8Amps 0.125 & 0.160, 0.5-0.8Amps/ 1-25Amps AOV"BPFS,U TESTREPORT R02 NO.:4002R12100802+1 Dare:ocr.10,2012 Customer:SuzhouFuHongElectronjc InduslrialCo., Lld. XIANGCHENG DlsTRlCT, SUZHOU, CHINA Addres!:NO.89WEIDUROAD,WANGTINGTOWN, to be Reporton ths submitreds.mplesald S.mplename:CoppeJ,shell Mod€h/ Item/LoiNo.:/ Metarlal:/, Buyer: / , Suppli€r:/ Samplorecaivsdd.te: Ocl.08.2012 1o'O4r'10, 2012 Testinsperiod:Ffomoct os,20!€ '\l ' . . ,, E9S!.s-Ecs!ed9!f samplein Chrcmium contentin thesubmitled & Hexavalent As specifiedby dient, to determineihe Lead,cadmlun, Mercury accordancewith Dircctive2002/95/EC{RoHS). Ec!!!s-ee$9!.: instrumeni I\4QL Measunng Testingltem (cd) Cadmium (Hg) [4ercury IEC62321:2008,s€ction9 |EC62321: 2008,seclionI 7 lEc 623212008,seclron Chromum(Cr\rl) IEC623212008AnnexB Lead(Pb) ICP€ES 2-'nglkg ICP-OES 2 mg/kg tcP-oEs 2 mg/kg 0.02m9/k9' Ieq r 0.02mg/kgreE|sto theMQLofsampleextfaction liquid SsElcge!: Decision ol 18 Aug 2005 of commission -whentesledas speci{i€d withthe requirements samplecomplied the submitted 2005/618/Ec noiiliedunderdocument 2002/95/Ec Directjve amending ILS,PLEASEREFERTOTHE FOLLOWNGPAGE(S)*** signedlor andon behalfof Brcncn Co.,Ltd,Kunshan Technology Shenzhen AOVTesling We-r k] n **n*"oor, /blfil caeateaaer: LiTingting,Maggie ooo,',*or44. Ylan Qi, lrickey Chemic€lTestDirecror S I t E N 2 H E NA O V T f S I I N G T € C H N O I , O 6 YC O . , I " T O . K U N S N ABNR A N C T I , /// \ Noll ne Ja,t 7tt) 9€'t'o AOV'*F#S,[ TESTREPORT NO.:4002R121008024-1 R02 Oate:Od.10,2012 1. To Determiney'.ead, C€dmium Contenli(Metalsubslrate) I*redby (y'a04* Weighihe sampleinto Add ihe digestionsolulionithe vesselis heatedunlilthe sample AddHrOruntilthe sampleis clear nlter;washed and Cooling thevess€|, Rlled wat€r. 10themarkwithdistill€d To Dete sulit€le) Content i|retb.r . \ . The sampleis digestedin the Weighihe sample microwaveovenfollowinga specific decomposrlonprogram Tested by lcP-oES Coolingthe vessel,tiltei washedand filledlothe maiKwilh dislilledwater. ChromiumContenl(boiling-wat€F€xtlaclion):([4etalEubstrate) Takethe (50i5) cm, samplein the beaker. Heat50 mLof Olwaterin thebe6ker to boilingfor 1o F;;1.- lhe sample, andcool Remove thebeak€rto roomtemperature, anddo thecolorreaction Testthe samplesolutionand lhe 0.02 ng/kg standardsolltion by uv-vls. BSANCH lCCINOLOGYCO.,LTD.KUNSIIAN SH€NZH€NAOVTESTITIG (: Hotlrne 'tL)0700 8600 nov'Bpf,F,il TESTREPORT NO.: 4002R121008024-1R02 Daie:Ocl.10, 2012 5. TooetemineHexavalenl Chromium Contonlin colorlessand coloredchromatecoatingon metats:iPtating) _ .. -i\ : va'hu't' lfthe lest resultis positive, the sample is consideredto havehexavalent chmmium Place 1-5 Boiling- water- extraotion procedu€shallbe usedto and the 0.02 mg/kg lflhee is interference or it is hardto decide whetherlhesamplehavelhe hexavalent 5.2Boiling-wateF enradion Remove thesample, andcool thebeaker lo roomtemperalure, anddolhe colorreaction Heat50 mlof Dlwaier in the samplein thebeaker. beakerto boilingfor 10 min Testtnesamplesolution andlhe0.02 mg/kgstandadsolulion by UV-VIS. SampleDelcriptlon: Code 1-1 SampleDescndion Substrate Plating Te3tR63ulb: Unit RoHSLimit Lead(Pb) msfts 1000 N.D. 10 (Cd) Cadmium Merorry(Hg) mg/K9 N.D. ms/Kg 100 1000 N.D, N.O. N.D. Chromium {Crl,ll) m9/kg 1000 Negative Negative s8€NZh€N AOVT€SrtNGTECHNOlOSYCO,,tTD,TUNSHAI! ARANCH ,.r Ho t l i ne .100700B6a0 nov'F"Ff"qn TESTREPORT No.:A002R1210o602:L1 R02 -ThenewRoHSdircclive 2011/6tEU,on Jul.21,2011comeintoforc€,onJan.03,2013lheformalimplementation, Direclive 2002r'95/EC simultaneously. ahallbe repealed Sp€cimens, whichr€Slested lo detemineLead,Cadmium havebeendissolved andMercury Content, completely, -mg/kg=ppm , -N.D.=not i",,,,,, ( The iested sample resultis uncertain or neoatve., -"The te8t is bas€d on lhe followins d!!{mplifi: maybe cannot stand lor the physical lrdh 6t s€r Coppershell SH€NZII AFANCH AOVTIST|n|GTECHNOIOCVCO.,ITD.KUNSHAN Ho t l i ne 400 /00 8600 a GTI#,ffiffi,H TestReport ageI of4 ReportNo. RLSZE0o1492l00002 Applicart Address CO.'LTD DONGGUANCITY XNHAI METALPRODUCTS 'ST COMMUI"IIry I WEIMING ROAD HENGZENGAV.XINAN TOWN DONGGUANCITY GUANGDONGPROVINCE GAN by/onthe The following samplqs) and samPleinformttion wavwere submitt€drnd id behaHof the client BASEOFCAP SampleName BRASSH65 Materidl SampleReceivedDate Nov.16,2012 Nov. 16,2012to Nov. 19,2012 TestingPeriod As specifiedby client,to testLead(Pb),Cadrnium(Cd), T€st Requ€st€d Hexavalent Chromium(Cr(Vl)) in the submitted sample(s). T€st Method Ed.l Sec.9 IEC62121:2008 IEC612r:2008Ed.l S€.9 Ed.t Sec-7 IEc 62321:2008 Ed.l AnnexB IEC62121:2C108 Pleasereferio the following page(s). Test Result(s) Di.d !y picL L Ddc Appt@dR $6i.d Cdlldi€Iffi Nov. 19, No. I 033098 ttu4!. (S*)Co-Lrt cottonNlol{ c!!rnE rEslrNgINrEtNAlloNAl comot.r4lc6ti D755,33tSii'ra lc Rcvicr€d by Eofi,li LinNlti{ Zfla BD'a ru Dntrrt cdmplsrn1E ft sll- .orip s ll@cx'e Glnfdd&Chil @4 0 0 - 0 7 8 E . 3 ! 3 ftn I F_}'H.mryl GTI TestRePort Page2 of4 ReportNo. R1S2E001492100002 T€rr R€rrlt(sl Testedltem(s) Lead(Pb) Cadmium(Cd) Mercury(Hg) Chromium(cr(v l)) Hexavalent TestedSample/PartD€scriptioD Note: Result 13 mgllg N.D. N.D, Negative Metalbase totally testedfor Lead,Cadmium' ry. The samplehad bdendi,csolved = -MDL MethodDetectionLinit -N.D. = Not Detected(<MDL ) -mg/kg= pptn= PartsPermillion in boiling -Negative= Abs€nceofC(VD , the detectedC(VI) concentration samplesurface a used. extractionsolutionis lessthan0 02 mg/kgwith 5ocm'? cl{ra[ trt t T t t a Gr N l a l N A l l o l l A l c o l P o l a l l o l I cal] 0755.331t81700 corpls'nl E mtrl con! r'ilG)cl ced cr)ri 0 0 , 6 7t 8 - 3 3 l E-fla FJrE.',{e'r ':. o GTIF_i,H"m,m TestReport ReportNo RIS2E001492100002 Page3 of4 Test Process 1. Lmd(Pb),Cadmiun(cd) 2, Mercury(Hg) Weigh saraple ed place it m a microwave digE'stionves sel Chromiun(C(Vl)) 3. Hexavalent Sdecl a test sallplc m.aswing about 50t5cnf AElyred ty UV-V1s cottolallofl ctuTtt t!st| o rNlElrlaltoNAL .4mcirrrtt.l' ren c'n E_m6r 0755-!36S:7i0 Compi:r.r conormLnrcrll @.iif;".,,, a GTI#,mffi,^)# TestReport ReportNo. RLS2E001492100002 Pag. 4 of 4 Photo(s)of the sample(s) *** End of rcport*** Thetestaeportis effectiveonly with bothsignatueandsp€cializedstamp.Theresult(s shownin this report refer only to the sarnple(s)tested.Without written approvalof CTI, this can't be reDroduced exceDtin full. c c N l a E t a i r | N G t N l E R N A l t o l t Acl o l t o l ^ r i o N n l- r 3 r l c o n p i a' u r d c I N e nc o m C o m o r a rcnar r r0 7 5 5 - 3 3 6 8 1 1 0 0 C o m p l s r E E nra,, .,'ii,. i.fliLd O;';;,;",,,.,, a GTI#,HMJ"M TestReport ReportNo. RLSZE001492I0O00I PageI of3 DONGGUANCITY XINHAI METAL PRODUCTSCO.,LD I 'ST WEIMING ROAD HENGZENGAV.XINAN COMMLINITY TOWN DONGGUANCITY CUANGDONGPROVINCE Applicant Address by/on the The following samplqs) and sampleinformatiotr was/weresubmittedand behalfof the client SILVERCOLORPLATINGOF CAP SampleName El€ctrolyticNickel Material SampleReceivedDate Nov.16;2012 Nov. 16,2012to Nov. 19,2012 TestingPeriod As specifledby client,to testLead(Pb),Cadmium(cd), T€st Requested HexavalentChrcmium(Cr(Vl)) in the subrnittedsample(s). Test Mothod T€st Itein(s) Ed.t Ref€rto IEc 62321:2008 Ed.l R€ferto IEc 62321:2008 Refe.to IEC62321 :2008Ed.I IEC62321:2008 Ed.l AnnexB Pleasereferto thefollowing page(s). T€stResul(s) elc lliod Rrvi.&dby by teic.l Cd!f!di! I@bd Nov. 19, D& 4rt ov.dty (Sedd No. I 1033098 ltu|gr. Co-bf Ea8wdbtil Zoc Bs'- Cu-fiL.& 6na ToDitti:t' cotPol^lloll cItlrE ra5TrN6,NlEtNArroNl! codpLi hr cari 0 7 55-l3li I I / i)0 c ompldril E-fi3r1I cohpia rl@cl' ce.l .ofr E 03 !{4?.r rcfl in n a .a00.6tt6-!ll o GTIlt.)m.ffiirm TestReport Page2 of3 ReportNo. RLSzE001492l0000l Test€dSample/Prrt Desc ption Not€: silvery plating The wasb€dplrtirg had beondissolv€dtotally test€dfor Lead, Mercury. -MDL = MethodDetectionLimit -N.D. = Not Detected(<MDL ) -mg/kg: pprn= partspermillion -Negative= Absenceof C(VI) , thedetectedC(VI) concenbation in boilingwater used. extmctionsolutionis lesslhan0.02mg,&gwith 50cm2sarnplesurface Test Process l. Lead(Pb),Crdmium(Cd)' Mercury(Hg) Selecl a lesl sample 'n.asurmg aboul 50c!rf 2. Il€xaval€ntChrornium(C(VD) Selecl a !€st samplc mlasuring aboui 50t5ctrf A)alyr.d by UV-VIS c I f { r R l T E s l t r Gr N T l l N A l r O N A lC O I P O R A T I O f i r ^m l a r lc a m !r . l l . l d , c e n . o t c r l l 0 7 5 53 3 6 8 1 7 0 0 C o m p L EE Complsrn E-nn mio@q' r:.n ..n @4 0 0 - r 1 3 !! 1 3 o GTI#-),m.ffi^'Y! TestReport ReportNo. RLSZE00I492I00001 P€e3of3 Photo(s)ofthe sample(s) +** End of repon*** Thet€strcport is elfectiveonty with bothsignatureandspecializedstamp.The report ref€r only to the samplds) test€d.Witlod witten apProvalof CTl, this reorcducedexceotin full. cot?olAIloN ct,{nt f tlfltG rNIElr{ArrotrAt canro aLnlcair !f55-3308r fao lompla'nl E m$l coc'piii rlrc].l' ce1l c.rr shownin this can't be ,a a00-6188.133 T€stReport No.SHAEC1216714738 Page1 ol5 Date:25 Sep 2012 CO.,LTD MATERIAL SOLDERING&BRAZING ASIAGENERAL ZHEJIANG CHINA PROVINCE' CIry' ZHEJIANG, HANGZHOU PARK,SANDUN, XIHUINDUSTRIAL SoLDER The following 6ample(s)was/were submittedand identifiedon behalf of the clients as : LEAD-FREE WIRE Dateof Sampl€Received: TestingPeriod: TestR€quested: - SH sP12-028285 YTW2O6 sno.3Ag0.7ouce 21 Sep2012 21 s,ep2012- 25 SeP2012 Selectedtest(s)as requestedby client TestMethod: Pleasereferto nextPage(s) T€stResulb: : Condusion Pleasereferto nextPage(s). Baa€don the perfomedtestson submittedsamples'the resultsof Lead' (PBB)' biphenyls chomium,Polybrorninated Hexavalent I\rercury, Cadmium, RoHS by limits as set with the diphenylethe6 (PBDE)comply Polybrominated 200295/EC Annexll; recasting 2011/65/EU Di.ective SGSJobNo.: PartNo.(PN) : Compositlon: Signed for and on b€half of scs-csTc Ltd. /Qv'' .n#ffiffi Fan Jingiie,JJ Approved Signatory irmr r* u-ra -td *vot tirtDafi$EE|ihtltrorr il.t.|.*f,Ertr€€.lt$l rmrr.t.t t* zxtao ll@3 tErEl@llitldt6!E{ti"clt06t'9 Kr(,-tt)Eaffi xr.c+rti el iLnlirotllt ffior*ofr 1j!ltorSOSOtbt4 (aGS8A) T€6tReport No.SHAEC1216714734 Date:25 Sep2012 Page2 o15 TestResults: ; TestPertDe€criotion S@rn6n No, 1 D6ctiptioi SGSSampl€lD wire SHA12-167147.035Silvery Rgmarks: (1)1 mg/kg=I PPm=00001% Limit (2)MDL= MethodDeteclion (3) ND = NotD€teded( < lrDL ) (4) '-' = NotRegulated RoHSDllBdivs201l/85/EU Test Llethod with referenceto lEc 62321:2008 (1)Determination of cadmiumby ICP-oEs. (2) Dete.mination of Leadby ICP-oEs (3) Determination of Mercrlryby ICP-OES. (4) Determination Chromiumby Spottest/ Colorimetricl\,ethodusingUV-Vis of Hexavalent (5)Detemination by GC-[IS. PBBS i PBoES of Limit 100 1000 1000 Test ltem{s) Cadmium(Cd) Lead (Pb) Mercuryfig) HexavalentChromium(Ci(VD) UlE mdkg ms/kg ms/kS mS.ftS mS/kS mdkg mdkS mSikS mdks ms/kg mg/kg mdkS msikg mdks mgftS mg/KS 1000 - Sumof PBBS Monobromobiphenyl Dibromobiphenyl Tribromobiph€nyl Tetrabrornobiphenyl PentabromobiPhenYl He/€bromobiphenyl HeptabromobiPhenyl Octabromobiphenyl NonabromobiPhenyl DecabromobiPhenYl SumoI PBDES ether Monobromodiphenyl 1m0 - 5 5 s 5 5 5 5 5 5 5 5 ND 50 ND N€gative ND ND ND ND ND ND ND ND ND ND ND ND ND ffi ffiffi:ffi g"fff ###f rffi !#,g;"EHT* *,Hffi ffi Stift Ufi *lvl*sm.1m*ts""nr* #ffi*,rx*$'#'ffi Ij*tffi b D.r. na co{d6 ;;bii*hEni-.6fr l\rDL 2 2 2 o Sffi*ff d tbtk *r I r6tr.{.)r-H tt-ErrlFYasft.cxd|lt.9|dlcrn +l -l|.*tr[lt|fte||6+l zfrlr3 lr:2@ tElEF{lF6tl rd€6+1)6r.@ Hit!-2l164@raa it{&aFl@ (8cgs ) lr.nD.t o1$.8GgOrouP Tes{Report No. SHAEC1216714738 Test ltem(s) Dibromodiphenylether Tribromodiphenyl ether Tetrabromodiphenyl ether Pentabromodiphenyl elher Hexabromodiphenyl ether Heptabromodiphenyl ether Oc-tabromodiphenyl ether Nonabro.nodiphenyl ether D€cabromodiphenyl ether thi! Date:25Sep2012 UdT MDt mdkS mdkS mdkS mdkg mS/kg mSikS mg/kg mS/kS mgkg 5 5 5 5 5 5 5 5 5 Page3 of 5 @ ND ND ND NO ND ND ND ND ND Notes : (1) The maximumpermissiblelimitis quotedfromdiredive2011/65/EU, Annexll (2) ospot{est: Negative = Absence of Cr(Vl) coating, Positive= Presenceof Cr(Vl) coating; CIhe tested sample should be fudher verifed by boiling-waterextractionmethodif the spot test result is Negative or cannot be confirmed.) oBoiling-wateFextraction: Negative = Ahsence of Cr(Vl) coating Positive = Pesence of Cr(Vl) coating;the detectedconcentrationin boiling-water-ext€ctionsolution is equal or greater than 0.02 mgl(q with 50 cm'zsample surtace area. For corrosion protectioncoatingson metals: Informationon storage conditionsand producliondate of the tested sample is unavailableand thus results of Cr(Vl) representstatus of lhe sample at the time of testing. t'ilt,b.aYrbto +1 drchrbrd,Swaon !e3a I ErE{O-Zr)OtrOO raEFaFffiTl *FA)ala@!.a |{j{l.?J)6r@ M.m!.rorh.scsGtuc(acgs ) TestReport No.SHAEC1216714734 Page 4 of 5 Date:25 S€p2012 ATTACHMENTS RoHSTe€tingFlowChart xu Xiao/Gary Wang/Allen JanShi/Yoyo 1) Nameof the personwhomadetesting: Xu/LindaLi ' 2i Nameof thebersonin chargeof testing:JeffZhang/George chart.(Cf to berowflow accorcting 6'ypre-condit-roningherhod totarry aissoried iiiii,"i !!rir!!,i. testmethodexcluded) andPBBdPBDES SamplePrcparation SampleMeasurement Pbrcd,Hg PB86fPBDE8 Acid digestionwith microw€ve/hotplate Concentration/ Dilutionof extraclion solution '1)AlkaliFusion/ DryAshing 2) Acidto dissolve Adding1,s diphenylcarbazide for color development A red color indicatesthe presence of cP'. neceas€ry, confirmwith tr 'l';-;Ltidbd$rffi'd6.h*lhE.,nrdri*6 tilairl$gYb.rto dErloat4ltrtracnr 20(43 a|lM fl..tjt.*Iqldl|6els+l rEtEFzr)0tac53 rE&&4lrsa l+{a-a)dlqaa rtjF.?1)6@ $6nb.fol th.ao6 GlDlD{8oas ) TestReport No.SHAECl2'16714738 Date:25 Sep2012 Page5 of 5 Samplephoto: sHA12-167147.035 SGSauthenticato the photoon originalreportonly '* Endof Report"" (d-l!r. .Dor -iibhihr.ldcn.h, '|l!!a|i!!{l|ddbd' ,td.lwb|||d4ded tLlliDl! Bftfiufition tr.tl.*tr6l||,|rF|6r+l 2dEs ll: @3 rElE[6-eDdag6l lElfF2l!ffia rr{&a1}ara@a ttF+lFN d6.ccil *6r*.& .,9d'rt.l.- l|.fiDcrolm. SOSGtu,D|SOSS ] TestReport No. SHAEC1216714749 Date:25 Sep2012 Page1of 5 ZHEJIANG ASIAGENERAL SOLDERING&BRAZING I.iIATERIAL CO.,LTD XIHUINDUSTRIAL PARK,SANDUN,HANGZHOU CITY,ZHEJIANG, PROVINCE, CHINA The followingsample(s)was/weresubmittedand identifiedon behalfof the clientsas : LEAD-FREESOLDER WIRE SGSJobNo.: PartNo.(P/N): Composition : Dateof SampleReceived: TestingPeriodI - SH sP12-028285 (692535-002) YTW'102 TestRequestedI Selecledtest(s)as requestedby client. Test l\relhod: Pleasereferto nextpage(s). Pleas€referto nextpage(s). Basedon the performedtesb on submitteds€mples,th€ resultsof Lead, (PBB), biphenyls cfiromium, Polybrominated Meroiry,Cadmium, Hexavalent (PBDE) withthelimitsas setby RoHS comply Polybrominated diphenylethers 200295/EC. Annexll; rec€sting Directive 2011/65/EtJ Sn2.ocuRE 21 Sep2012 21 Sep2012- 25 Sep2012 T€stResults: : Condusion Signed for and on bohalf of SGgCSTC Ltd. .,/1,- ,rt*{'""^ FanJinqjie,JJ ApprovedSignatory H, ',E l.db&o-d cdd|{d. orswI6 frqiiffi*#r"r#H'ffil'ft1#l'l'Id*i,ffi t.Uiltrar|$&r,lrnllq,gldicti! *l '.tf. *ir8l'lraast3rtll @ ar:M M6t{rm tEl€(S{1)t1{q60 l6lE(E-llF{S't9 Hljfi.2l)614&r04rl!(s-n)$5d83''q9dmFdl (SGssA) Momlarolth. SGsGloup TastReport No.SHAECl216714749 Date:25Sep2012 Page2 of 5 TestResulb: TestPartDescriotion: Sp6dr|on No. 1 SGSSamplolD Dgcriptio.l SHA12-167147.042 Silvery wire Rema*s: (1)1 mg/ks=1 PPm=0.0001% (2) lrDL = LlethodDeteclionLimit (3) ND= NotDetected( < IVDL) (4)'-" = 1o1q*r,","d RoHSDlrB.dv€2011/55iEU TestMethod: Withreferenceto IEC62321:2008 (1)Determination of Cadmium by ICP-OES. (2) Determination of Leadby ICP-OES. (3) Determin€tion of l\rercuryby ICP-OES. (4) Deteminationof Hexavalent Chromiumby Spottest/ Colorimetric MethodusingUV-Vis. (5)Detemination of PBBS/ PBDES by GC-[IS. Testltem(s) Limit unit 100 msfts 1000 mdkg Cadmium(Cd) Lead (Pb) Merd.iry(Hg) (C(Vl)) Hexavalent Chromium Sumof PBBS Monobromobiphenyl Dibromobiphenyl Tribromobiphenyl Tetrabromobiphenyl Penlabromobiphenyl Hexabmmobiphenyl Heptabromobiphenyl Octabromobiphenyl Nonabromobiphenyl Decabromobiphenyl Sumof PBDES Monobromodiphenyl ether ,o:o *1* 1000 _ 1000 - mdlQ ms,/KS mg/Kg mg/Kg mgxs mg/Kg ms/Kg msfts mg/Kg mgKg mgKg mg/kg mg/Kg MDt 2 @2 N D 2 1 n 2 o - N D Negative N D 5 5 5 5 5 5 5 5 5 5 - N N N N N N N N N N N D D D D D D D D D D D 5 N D rh!dcllld|rb.4.'lh irdd,''q1..!'*fut -rd.dcr{rt h&!tu, i;c-;ii;di;d; rd, rr;'iirrd firhr.drd na.!rdb. blB thbrdrr.tth.4s' riE.Ir.c@-tr rh dr$fitv doffid sd sd [email protected] &diii, it(rn;i;. * t F ht c r.d ndtu @mr.6 i.r ffir h Mr'. md Fd b E 6,tu0.. Md d-tr n d-pt Mr'. md Fr {nl!...l .ry6brhrr.olr..bd tr.ldnlBrrsto d&nrdri4srtrcrh 2@ l* 2@3 Sl.I|.*f:At[lls8eB3et lElEteeld.0e$! IElE&al6OSt9 ru{s-2r)61r&9rrLo-aFas! *.i..4..06 ..$drro.}6 lilrmDor orth€SOSGlou!(scs s ) TestReport No.SHAECl2'16714749 T6stltem(s) Dibromodiphenyl ether Tribrcmodiphenyl elher Tetrabromodiphenyl ether Pentabohodiphenyl ether Hexabrcmodiphenyl ether Heptabromodiphenyl ether Oclabromodiphenyl ether Nonabromodiphenyl ether Decabromodiphenyl ether thi! Date:25Sep2012 llil MDt mg/kS mg/kg mSikS mg/kg mg/kg mg/kg mg/kg mg/kS mg/kg 5 5 5 5 5 5 5 5 5 Page3 of 5 g2 ND ND ND ND ND ND ND ND ND Notes : (1) The maximumpermissible limitis quotedfromdiroclive2011/65/EU, Annexll (2) "spot-test:= Negative Absence of Cr(Vl) coating, Positive= Presenceof Cr(Vl) coatingi (The tested sample should be further verified by boiling-wateFextractionmethod if the spot test result is Negativeor cannot be confirmed.) oBoiling-wateFext€c{on: Negative = Abs€nc€ of Cr(Vl) coating Positive = Presenceof Cr(Vl) coalingt the detectedconcentrationanboiling-water-extractionsolution is equal or gre€ter than 0.02 mg/kg wilh 50 cm':sample surface area, For corosion protectioncoatingson melals: Informationon storage conditionsand productiondate of the tested sample is unavailableand thus results of Cr(Vl) representstatus of the sample at the time of testing. .Md b r&d br rh cmtsry !!Fr &iid d.dniatL4n b r. o.€llc.ndr6o, l.ft.na cor,|n6 !.n14 pid-.shd, ri.t'rl.ddbrl h.t!dn, nri rh.C@!/. mcot&.rb.frrst rE.d'{t Nr.Db d rqu.l ro,.r-M.e$r brstddoidoxbm'd .el4dbdold.lbofu| e xdrd!|. d !!e44a, {r 6'!4qtil.dr6r hblt [email protected]'I|dh E4dd.rarr h tu[,*r6d rd'd irrbih.rnD.(.)bbc t: I I rtallt&lb.r'idErilb!{tllrlto.r +r.tl.*tr 2!@ l E!E$-A)6!1G53 lElEl{EAF6!r9 Hr{an}6J4G04 fr(6-A)do63 r*.64*M .!d..dire.t-6 Mombdolrh. sqs cloup(8qssA) T€€tReport No.SHAEC121671474S Date:25 Sep 2012 Page 4 of 5 ATTACHMENTS RoHSTestingFlowChart 1) Nameof the personwho madetesting:Jan Shi/YoyoWangy'Aen Xiaor'caryXu 2) Nameof the personin chargeof testing:Jeff ZhangJceorge Xd LindaLi 3) Thesesamples wereda66olved totallyby preconditioning methodaccording to betowflowchad.(Cf' andPBBS,/PBDES testmethodexcluded) Sample I\reasurement Pb/CdrHg PBB8/PBDEs Nonmetallic mateial Concentration/ Dilution of extraction solution 1)AlkaliFusion/ DryAshing 2) Acjdto dissolve Adding1,5diphenylcabazide for color development htr @dd I sud br rh 6l!|q eq.d b L o,nrc.dd*..r 3.e tsdr os&t,.nbr. m q{, d |d'D. r-{!rtRt&. d lud'& h,.otod tulr ^ry Fr.r.,dr @id h dld hriiGd$-EAE d tlslfii,-dlli!$in|ltr. hr d q$t| hd6noE. r mr n 6o.bvr ,r. i@dr'ny i b rn crr.d $ itFltc*larrfimhnrddl{.rrd.uic..UihB.dbdddnts.r rrh@ddflior!.|@d,{d.,F .,..fle.,6l!" d t/d@o,Ed rr b tu rhrr.(,) brh . s't-E't eYlu tod&trl|tr.€E Sl,I|.ftE8l'!ft3e+3*l torr 2@ ll:2@ r! ib:lffi ia6ffEft Adding1,5diphenylcarbalde for color development A red color indicates the presenceof Cr6'. necessary, confirmwith E.ffin ccqdrr !!m rlld .!!'!rc!rl rEir .'hbd rInlull,rhtu4tsrdr!. *6Ia..m rEEis-el)il{@! IEtEFA)64Agn ..g5d.qb.@ H!(6-41)61{@l fNrl*-a)Aaa63 M6mbq ol the AGS Oroqp (SqS SA) Test Repori No.SHAEC1216714749 Date: 25 Sep 20 12 Page5 of 5 Samplephoto: sHAl2-167147.042 repodonly thephotoonoriginal SGSauthenticate '"' Endof Reporl"* bi Eb.n' b r.n. d (dh.n eqii'i i.;i'' r-m* r-io a"-;.N tvw"i"iiiB-;;';;;tt;;; ili,i,"lii:*#r.i^imua'qFsq;a"tauo"" iil',i,",ii?ji;;iiiiiifiil;i;iifi:;i;;ii;;;fib-;;;;;;r];;;i ..no|x*rg&.lidp'hr'rg.4ld Atudbr hr '{dr-!!4!s1 b d "!eua!sn rhdhe xhhftd h"co'P""r'i'ne-''h,h-o' 'irr('6if,ni6Endd-hiii*,-ds.conFivt 'dGid6n'!Mir'6' iii,iirriinulo"n..ol.-'r'iryYl'c@-yrstdD6! h tun'"r'o' $l"in rio ourmuo ro, not-.a o"ooo'o.rr nr oooni-nn;iU@';dlad "FD' d t" d-'".{ k i;;;;';.;;e;.-n. $ll;-iii?iini--;;; "i nrrrcri.r'^t.G)krtd " Dodrstr cha 2o@3 t"afEnr3gYssmF@dxlinicriild,sturdf ilnr2oca33 +E.!l.*[Alul36s!3+il tE&E{6e{r$4946?9 R639.coh l aE (s-z )61lozsst fu (6-lr)fireset HLm-21s45@63 . lqidlE€tsFs h€sGs Glouo(sG9SA) M6mberofi Test Report Applicant: Number: ELSCHUKOM ELEKTROSCHUTZKOMPONENTENBAU GMBH GEWERBESTRASSE 87,D-98669 VEILSDORF, GERMANY Date: SHAH0036227401 JAN 18, 2013 Sample Description: Two(2) pieces of submitted samples said to be : (1) Mixed all kinds of metal substrates. (2) Mixed all kinds of plating layers. Item Name : Silver Plated & Pure Silver Wires. Item No. : (B-1) 101.014 -. ---– silver plated copper wire – Cu, Ag--% (B-2) 101.0131.---– pure silver wire – Ag 1000 (B-3) 101.0123.0--– silver plated purest nickel wire – Ni99.98%, Ag1% (B-4) 101.0182.0--– silver-copper alloy plated copper plated iron nickel alloy wire – ElconD, AgCu5% (B-5) 101.0120.0--– silver plated constantan wire – CuNi44, Ag5% (B-6) 101.0151.0--– silver plated copper - nickel 44 alloy wire – CuNi44, Ag10% (B-7) 1050--31.-------– pure silver strips – Ag 1000 pure Country Of Origin : Germany. ************************************************************************************************************************************************************ Tests Conducted: As requested by the applicant, for details refer to attached page(s). ************************************************************************************************************************************************************ To Be Continued Authorized by: For intertek testing services Ltd., Shanghai Jacob Lin General Manager Page 1 Of 5 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH0036227401 Tests Conducted (A) Test result of RoHS Directive: Result Testing item (1) Cadmium (Cd) content (mg/kg) ND Lead (Pb) content (mg/kg) ND Mercury (Hg) content (mg/kg) 6+ Chromium2(VI)(Cr ) result (by boiling water extraction on metal) (mg/kg with 50cm ) ND ND Result Testing item (2) Cadmium (Cd) content (mg/kg) /Plating ND Lead (Pb) content (mg/kg) /Plating ND Mercury (Hg) content (mg/kg) /Plating ND 6+ Chromium2(VI)(Cr ) result (by boiling water extraction on metal) (mg/kg with 50cm ) /Plating ND 2 Remark:mg/kg with 50cm = milligram per kilogram with 50 square centimeter ND = not detected (B) RoHS Requirement: Restricted substances Cadmium (Cd) Lead (Pb) Mercury (Hg) 6+ Chromium (VI) (Cr ) Limits 0.01% (100 mg/kg) 0.1% (1000 mg/kg) 0.1% (1000 mg/kg) 0.1% (1000 mg/kg) The above limits were quoted from RoHS Directive 2011/65/EU for homogeneous material. (C) Test method: Testing item Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content 6+ Chromium (VI) (Cr ) content (for metal) Testing method With reference to IEC 62321 Edition 1.0: 2008, by acid digestion until the tested sample was totally dissolved, and determined by ICP-OES. With reference to IEC 62321 Edition 1.0: 2008, by acid digestion until the tested sample was totally dissolved, and determined by ICP-OES. With reference to IEC 62321 Edition 1.0: 2008, by acid digestion until the tested sample was totally dissolved, and determined by ICP-OES. With reference to IEC 62321 Edition 1.0: 2008, by boiling water extraction and determined by UV-VIS Spectrophotometer. Reporting limit 2 mg/kg 2 mg/kg 2 mg/kg 2 0.02mg/kg with 50cm (in testing solution) Date sample received: Jan.14, 2013 Testing period: Jan.14, 2013 To Jan.17, 2013 ************************************************************************************************************************************************************ To Be Continued Page 2 Of 5 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH0036227401 Tests Conducted (D) Measurement flowchart: Test for Cd/Pb/Hg/Cr (VI)/PBBs/PBDEs contents Reference standard: IEC 62321 Edition 1.0: 2008 Sampling/grinding or cutting Cr Cd/Pb/Hg Metal Weigh sample and for different material, digest the sample with *1 appropriate acid Positive No Confirm the tested samples are totally dissolved Yes Polymers / electronics PBBs/PBDEs Weigh sample and add alkaline solution Spot test Get 50cm samples 6+ Weigh sample and add organic solvent *2 Definite temp. Extraction 2 Boiling water extraction Soxhlet extraction or Solvent extraction Cool and filter the extract Concentrate the extract and make up with organic solvent Make up with deionized water Analyzed by ICP-OES Make up with deionized water and add diphenyl-carbazide solution Analyzed by GC-MSD Analyzed by UV-VIS Remarks: *1: list of appropriate acid: Material Polymers Metals Electronics Acid added for digestion HNO3,HCL,HF,H2O2,H3BO3 HNO3,HCL,HF HNO3,HCL,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. ************************************************************************************************************************************************************ To Be Continued Page 3 Of 5 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH0036227401 Tests Conducted ************************************************************************************************************************************************************ To Be Continued Page 4 Of 5 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH0036227401 Tests Conducted ************************************************************************************************************************************************************ End Of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. Page 5 Of 5 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Applicant: Number: LITTELFUSE,INC. 800 E. NORTHWEST HWY A.DIVIETRO/D.UNTIEDT Attn: Date: SHAH00361401 JAN 16, 2013 Sample Description: One (1) submitted sample said to be Grey Wire. Item Name : Wire Tin Plated Cu. Part No. : Element. ************************************************************************************************************************************************************ Tests Conducted: As requested by the applicant, for details refer to attached page(s). ************************************************************************************************************************************************************ To be continued Authorized by: For intertek testing services Ltd., Shanghai Jacob Lin General Manager Page 1 Of 4 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report SHAH00361401 Number: Tests Conducted (Ⅰ) Test Result Summary: Result (ppm) (1) Testing Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content 6+ 2 Chromium VI (Cr ) content (mg/kg With 50cm ) ND ND ND Negative (< 0.02) Testing Item Result (ppm) (2) Heavy Metal Cadmium (Cd) content / Plating Lead (Pb) content / Plating Mercury (Hg) content / Plating 6+ 2 Chromium VI (Cr ) content (mg/kg With 50cm ) / Plating ND 60 ND Negative (< 0.02) Remarks: ppm = parts per million = mg/kg ND = not detected 2 @ = Due to the insufficient sample area, reduced total sample surface of 10 cm was used and the dilution factor was adjusted accordingly. 2 mg/kg with 50cm = milligram per kilogram with 50 square centimetre Tested components: (1)Substrate. (2)Plating. Responsibility of Chemist: Dent Fang / Ken He (Ⅱ) RoHS Requirement: Restricted substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content 6+ Chromium VI (Cr ) Content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from RoHS Directive 2011/65/EU for homogeneous material. (Ⅲ) Test Method: Testing item Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content 6+ Chromium VI (Cr ) content Testing method With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in Annex B, by boiling water extraction and determined by UV-VIS Spectrophotometer. Reporting limit 2 ppm 2 ppm 2 ppm 0.02 2 mg/kg with 50cm Remark:Reporting limit = Quantitation limit of analyze in sample Date Sample Received:Jan.9, 2013 Testing Period:Jan.9, 2013 to Jan.14, 2013 ************************************************************************************************************************************************************ To be continued Page 2 Of 4 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH00361401 Tests Conducted (Ⅳ) MEASUREMENT FLOWCHART: Test for Cd/ Pb/ Hg/Cr (VI)/ PBBs/PBDEs contents Reference standard: IEC 62321 edition 1.0:2008 Sampling/grinding or cutting Cr Cd/Pb/Hg Metal Weigh sample and for different material, digest the sample with *1 appropriate acid No Get 50cm samples Yes Weigh sample and add organic solvent *2 Soxhlet extraction or Solvent extraction Cool and filter the extract Make up with deionized water and add Diphenylcarbazide solution Analyzed by ICP-OES PBBs/PBDEs Definite temp. Extraction 2 Boiling water extraction Make up with deionized water Polymers / electronics Weigh sample and add alkaline solution Spot test Negative Confirm the tested samples are totally dissolved 6+ Concentrate the extract and make up with organic solvent Analyzed by GC-MSD Analyzed by UV-VIS REMARKS: *1: LIST OF APPROPRIATE ACID: MATERIAL Polymers Metals Electronics ACID ADDED FOR DIGESTION HNO3,HCl,HF,H2O2,H3BO3 HNO3,HCL,HF HNO3,HCL,H2O2,HBF4 *2: IF THE RESULT OF SPOT TEST IS POSITIVE, CHROMIUM (VI) WOULD BE DETERMINED AS DETECTED. ************************************************************************************************************************************************************ To be continued Page 3 Of 4 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH00361401 Tests Conducted *********************************************************************************************************************************************************** End of report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. Page 4 Of 4 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Number : TWNC00294415 Test Report Applicant: Littelfuse Philippines Inc. LIMA Technology Center, Lipa City, Malvar, Batangas Date : Jan 17, 2013 Sample Description: One (1) group of submitted samples said to be : Part Description : Tin plated Elcon Wire Element Part Number : 0042xx/ 0063x Date Sample Received : Jan 11, 2013 Date Test Started : Jan 11, 2013 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized by: On Behalf of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ0294415* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全國公證檢驗股份有限公司 11492 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 1 of 6 Number : TWNC00294415 Test Conducted (Ⅰ) Test Result Summary: Test Item Unit Result Test Method RL (1) (2) ND ND 2 ND 248 2 ND ND 2 Negative Negative 0.02 Heavy Metal Cadmium (Cd) content ppm Lead (Pb) content ppm Mercury (Hg) content ppm Chromium VI (Cr6+) content Remarks: mg/kg with 50 cm2 With reference to IEC 62321: 2008, by microwave digestion and determined by ICP-OES. With reference to IEC 62321: 2008, by microwave digestion and determined by ICP-OES. With reference to IEC 62321: 2008, by microwave digestion and determined by ICP-OES. With reference to IEC 62321: 2008, by boiling water extraction and determined by UV-Vis Spectrophotometer. ppm = parts per million based on weight of tested sample = mg/kg ND = Not detected RL = Reporting Limit, Quantitation limit of analyte in sample mg/kg with 50cm2 = milligram per kilogram with 50 square centimeter Negative = A negative test result indicated positive observation was not found at the time of Test. When the spot test showed a negative result, the boiling water extraction procedure shall be used to verify the result. Tested Components (1) Coppery metal wire base material (2) Silvery plating layer Responsibility of Chemist: Date Sample Received Test Period Kevin Liu/ Irene Chiou : Jan 11, 2013 : Jan 11, 2013 To Jan 15, 2013 *THJ0294415* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全國公證檢驗股份有限公司 11492 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 2 of 6 Number : TWNC00294415 Test Conducted (Ⅱ) RoHS Limits: Restricted Substances Limits Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from Annex II of 2011/65/EU for homogeneous material. *THJ0294415* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全國公證檢驗股份有限公司 11492 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 3 of 6 Number : TWNC00294415 Test Conducted (Ⅲ) Measurement Flowchart: Test For Cd/Pb/Hg/Chromium (VI) Reference Standard:IEC 62321 edition 1.0:2008 Sample preparation Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component Cd/Pb/Hg Substrate For different material, digest the sample with *1 appropriate acid Cr 6+ By spot test Confirm the tested samples are totally dissolved Make up with deionized water Plating Negative *2 Get 50cm2 sample By boiling water extraction Analyzed by ICP-OES Make up with deionized water and add diphenyl-carbazide solution Analyzed by UV-VIS *THJ0294415* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全國公證檢驗股份有限公司 11492 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 4 of 6 Number : TWNC00294415 Test Conducted Remarks: *1: List Of Appropriate Acid: Material Polymers Metals Electronics Acid Added For Digestion HNO3,HCl,HF,H2O2,H3BO3 HNO3,HCl,HF HNO3,HCl,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. *THJ0294415* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全國公證檢驗股份有限公司 11492 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 5 of 6 Number : TWNC00294415 Test Conducted Photo *THJ0294415* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全國公證檢驗股份有限公司 11492 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 6 of 6 Test Report Applicant: Number : TWNC00286464 Littelfuse Philippines Inc. LIMA Technology Center, Lipa City, Malvar, Batangas Date : Nov 22, 2012 Sample Description: One (1) group of submitted samples said to be : Part Description : Yarn Part Number : 648118_648119_648120 (6481xxx_GLZZxxx) Date Sample Received : Nov 15, 2012 Date Test Started : Nov 16, 2012 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ0286464* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 1 of 7 Number : TWNC00286464 Test Conducted (Ⅰ) Test Result Summary : Result (ppm) White Yarn Test Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Halogen Content Fluorine (F) Chlorine (Cl) Bromine (Br) Iodine (I) ND 14 ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND Remarks: ppm = Parts per million based on weight of tested sample = mg/kg ND = Not detected Responsibility of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received Test Period : Nov 15, 2012 : Nov 16, 2012 To Nov 21, 2012 *THJ0286464* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 2 of 7 Number : TWNC00286464 Test Conducted (Ⅱ) RoHS Limits: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr6+) Content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ehters (PBDEs) Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from Annex II of 2011/65/EU for homogeneous material. (Ⅲ) Test Method: Test Item Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Test Method With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in annex C, by alkaline digestion and determined by UV-Vis spectrophotometer. Reporting Limit *THJ0286464* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 2 ppm 2 ppm 2 ppm 1 ppm Page 3 of 7 Number : TWNC00286464 Test Conducted (Ⅲ) Test Method: Test Item Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) Halogen Content Test Method With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MS and further HPLC-DAD confirmation when necessary. With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MS and further HPLC-DAD confirmation when necessary. With reference to EN 14582:2007 by calorimetric bomb with oxygen and determined by Ion Chromatograph. Reporting Limit 5 ppm 5 ppm 50 ppm Remark: Reporting limit = Quantitation limit of analyte in sample *THJ0286464* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 4 of 7 Number : TWNC00286464 Test Conducted (Ⅳ) Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents Reference Standard: IEC 62321 edition 1.0:2008 Sample preparation For non-metal part For metal part Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component PBBs/PBDEs Weigh sample and add organic solvent By Soxhlet extraction or Solvent extraction Concentrate the extract and make up with organic solvent Cr 6+ Substrate Cd/Pb/Hg Weigh sample and add alkaline solution For different material, digest the sample with *1 appropriate acid Plating Cr 6+ By spot test Definite temp. extraction Cool and filter the extract Confirm the tested samples are totally dissolved Negative Get 50cm2 sample Make up with deionized water By boiling water extraction Analyzed by ICP-OES Analyzed by GC-MSD Remarks: *1: List of Appropriate Acid: Material Polymers Metals Electronics *2 Make up with deionized water and add diphenyl-carbazide solution Analyzed by UV-VIS Acid Added for Digestion HNO3,HCl,HF,H2O2,H3BO3 HNO3,HCl,HF HNO3,HCl,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. *THJ0286464* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 5 of 7 Number : TWNC00286464 Test Conducted (Ⅳ) Measurement Flowchart: Test for Halogen Content Reference Standard:EN 14582 Sampling/grinding or cutting Add absorbent in a combustion flask & place weighed sample in equipment Fill oxygen into calorimetric bomb Ignite then leave the bomb at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. *THJ0286464* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 6 of 7 Number : TWNC00286464 Test Conducted Photo *THJ0286464* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 7 of 7 Test Report Applicant: Number: LITTELFUSE,INC. 800 E. NORTHWEST HWY A.DIVIETRO/D.UNTIEDT Attn: Date: SHAH00361375 JAN 16, 2013 Sample Description: One(1) submitted sample said to be White Yarn. Item Name : Glass Yarn. Part No. : 648901. ************************************************************************************************************************************************************ Tests Conducted: As requested by the applicant, for details refer to attached page(s). ************************************************************************************************************************************************************ To Be Continued Authorized by: For intertek testing services Ltd., Shanghai Jacob Lin General Manager Page 1 Of 7 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH00361375 Tests Conducted 1 (Ⅰ) Test Result Summary: Testing Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content 6+ Chromium VI (Cr ) content Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Result (ppm) ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND Remarks:ppm = parts per million = mg/kg ND = not detected Responsibility of Chemist: Dent Fang / Leaf Liu (Ⅱ) RoHS Requirement: Restricted substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content 6+ Chromium VI (Cr ) Content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from RoHS Directive 2011/65/EU for homogeneous material. ************************************************************************************************************************************************************ To Be Continued Page 2 Of 7 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH00361375 Tests Conducted (Ⅲ) Test Method: Testing item Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content 6+ Chromium VI (Cr ) content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) Testing method With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in annex C, by alkaline digestion and determined by UV-VIS Spectrophotometer. With reference to IEC 62321 edition 1.0:2008 in Annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary. With reference to IEC 62321 edition 1.0:2008 in Annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary. Reporting limit 2 ppm 2 ppm 2 ppm 1 ppm 5 ppm 5 ppm Remark:Reporting limit = Quantitation limit of analyze in sample ************************************************************************************************************************************************************ To Be Continued Page 3 Of 7 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH00361375 Tests Conducted (Ⅳ) MEASUREMENT FLOWCHART: Test for Cd/ Pb/ Hg/Cr (VI)/ PBBs/PBDEs contents Reference standard: IEC 62321 edition 1.0:2008 Sampling/grinding or cutting Cr Cd/Pb/Hg Metal Weigh sample and for different material, digest the sample with *1 appropriate acid No Get 50cm samples Yes Weigh sample and add organic solvent *2 Soxhlet extraction or Solvent extraction Cool and filter the extract Make up with deionized water and add Diphenylcarbazide solution Analyzed by ICP-OES PBBs/PBDEs Definite temp. Extraction 2 Boiling water extraction Make up with deionized water Polymers / electronics Weigh sample and add alkaline solution Spot test Negative Confirm the tested samples are totally dissolved 6+ Concentrate the extract and make up with organic solvent Analyzed by GC-MSD Analyzed by UV-VIS REMARKS: *1: LIST OF APPROPRIATE ACID: MATERIAL Polymers Metals Electronics ACID ADDED FOR DIGESTION HNO3,HCl,HF,H2O2,H3BO3 HNO3,HCL,HF HNO3,HCL,H2O2,HBF4 *2: IF THE RESULT OF SPOT TEST IS POSITIVE, CHROMIUM (VI) WOULD BE DETERMINED AS DETECTED. ************************************************************************************************************************************************************ To Be Continued Page 4 Of 7 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH00361375 Tests Conducted 2 Halogen content (Ⅰ) Test result summary: Testing item Fluorine (F) Chlorine (Cl) Bromine (Br) Result (ppm) 350 150 ND Iodine (I) ND Remarks:ppm = parts per million = mg/kg ND = Not detected Responsibility of chemist:Grave Wang (Ⅱ) Test method: Testing item Halogen content Testing method Reporting limit With reference to EN 14582:2007 by combustion flask with oxygen and determined by ion chromatography 50 ppm Remark:Reporting limit = quantitation limit of analyte in sample Date sample received:Jan.8, 2013 Testing period:Jan.8, 2013 To Jan.14, 2013 ************************************************************************************************************************************************************ To Be Continued Page 5 Of 7 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH00361375 Tests Conducted (Ⅲ) MEASUREMENT FLOWCHART: Test for halogen content REFERENCE STANDARD:EN 14582 Sampling/grinding or cutting Add absorbent in a combustion flask & place weighed sample in equipment Fill the combustion flask with oxygen Ignite then leave the flask at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography ************************************************************************************************************************************************************ To Be Continued Page 6 Of 7 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH00361375 Tests Conducted ************************************************************************************************************************************************************ End Of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. Page 7 Of 7 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Applicant: Number: LITTELFUSE,INC. 800 E. NORTHWEST HWY A.DIVIETRO/D.UNTIEDT Attn: Date: SHAH00361371 JAN 16, 2013 Sample Description: One(1) submitted sample said to be Brown Liquid. Item Name : Solder Flux BC310. Part No. : 195116. ************************************************************************************************************************************************************ Tests Conducted: As requested by the applicant, for details refer to attached page(s). ************************************************************************************************************************************************************ Authorized by: For intertek testing services Ltd., Shanghai Jacob Lin General Manager Page 1 Of 13 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH00361371 Tests Conducted 1 (Ⅰ) Test Result Summary: Testing Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content 6+ Chromium VI (Cr ) content Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Result (ppm) ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND Remarks:ppm = parts per million = mg/kg ND = not detected Responsibility of Chemist: Dent Fang / Leaf Liu (Ⅱ) RoHS Requirement: Restricted substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content 6+ Chromium VI (Cr ) Content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from RoHS Directive 2011/65/EU for homogeneous material. ************************************************************************************************************************************************************ To Be Continued Page 2 Of 13 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH00361371 Tests Conducted (Ⅲ) Test Method: Testing item Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content 6+ Chromium VI (Cr ) content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) Testing method With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in annex C, by alkaline digestion and determined by UV-VIS Spectrophotometer. With reference to IEC 62321 edition 1.0:2008 in Annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary. With reference to IEC 62321 edition 1.0:2008 in Annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary. Reporting limit 2 ppm 2 ppm 2 ppm 1 ppm 5 ppm 5 ppm Remark:Reporting limit = Quantitation limit of analyze in sample ************************************************************************************************************************************************************ To Be Continued Page 3 Of 13 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH00361371 Tests Conducted (Ⅳ) MEASUREMENT FLOWCHART: Test for Cd/ Pb/ Hg/Cr (VI)/ PBBs/PBDEs contents Reference standard: IEC 62321 edition 1.0:2008 Sampling/grinding or cutting Cr Cd/Pb/Hg Metal Weigh sample and for different material, digest the sample with *1 appropriate acid No Get 50cm samples Yes Weigh sample and add organic solvent *2 Soxhlet extraction or Solvent extraction Cool and filter the extract Make up with deionized water and add Diphenylcarbazide solution Analyzed by ICP-OES PBBs/PBDEs Definite temp. Extraction 2 Boiling water extraction Make up with deionized water Polymers / electronics Weigh sample and add alkaline solution Spot test Negative Confirm the tested samples are totally dissolved 6+ Concentrate the extract and make up with organic solvent Analyzed by GC-MSD Analyzed by UV-VIS REMARKS: *1: LIST OF APPROPRIATE ACID: MATERIAL Polymers Metals Electronics ACID ADDED FOR DIGESTION HNO3,HCl,HF,H2O2,H3BO3 HNO3,HCL,HF HNO3,HCL,H2O2,HBF4 *2: IF THE RESULT OF SPOT TEST IS POSITIVE, CHROMIUM (VI) WOULD BE DETERMINED AS DETECTED. ************************************************************************************************************************************************************ To Be Continued Page 4 Of 13 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH00361371 Tests Conducted 2 Halogen content (Ⅰ) Test result summary: Testing item Fluorine (F) Chlorine (Cl) Bromine (Br) Result (ppm) ND 1000 ND Iodine (I) ND Remarks:ppm = parts per million = mg/kg ND = Not detected Responsibility of chemist:Grave Wang (Ⅱ) Test method: Testing item Halogen content Testing method Reporting limit With reference to EN 14582:2007 by combustion flask with oxygen and determined by ion chromatography 50 ppm Remark:Reporting limit = quantitation limit of analyte in sample ************************************************************************************************************************************************************ To Be Continued Page 5 Of 13 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH00361371 Tests Conducted (Ⅲ) MEASUREMENT FLOWCHART: Test for halogen content REFERENCE STANDARD:EN 14582 Sampling/grinding or cutting Add absorbent in a combustion flask & place weighed sample in equipment Fill the combustion flask with oxygen Ignite then leave the flask at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography ************************************************************************************************************************************************************ To Be Continued Page 6 Of 13 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report SHAH00361371 Number: Tests Conducted 3 HBCDD content (Ⅰ)Test result summary: Testing item Result (ppm) HBCDD (hexabromocyclododecane) ND Remarks:ppm = parts per million = mg/kg ND = Not detected (Ⅱ) Test method: Testing item Testing method Reporting limit HBCDD (hexabromocyclododecane) With reference to US EPA 3540C, by solvent extraction and determined by GC-MS 10 ppm ***************************************************************************************************************************************************** To Be Continued Page 7 Of 13 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH00361371 Tests Conducted Measurement flowchart: Test for HBCDD (hexabromocyclododecane) content Weigh sample and place into a thimble Soxhlet extraction with organic solvent Concentrate the extract Transfer the extract into a volumetric flask Make up with organic solvent Analyze by GC-MS ***************************************************************************************************************************************************** To Be Continued Page 8 Of 13 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH00361371 Tests Conducted 4 Phthalate content test With reference to EN 14372, by Gas Chromatography-Mass Spectrometry (GC-MS) analysis. Tested compound Result (%,w/w) Di-butyl phthalate (DBP) Di(2-ethyl hexyl) phthalate(DEHP) Benzyl butyl phthalate (BBP) Sum of three phthalates ND ND ND ND Limit(%,w/w) (MAX.) ------0.1 Remark:The above limit was quoted according to Annex XVII items 51 & 52 of the REACH regulation (EC) NO.1907/2006 & Amendment NO.552/2009 for phthalate content in toys and children care articles. Detection limit = 0.01%(w/w) ND = Not detected ***************************************************************************************************************************************************** To Be Continued Page 9 Of 13 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH00361371 Tests Conducted Measurement flowchart: Test for phthalate content Weigh sample and place in a thimble Extracted by soxhlet extraction with organic solvent Concentrate the extract TRANSFER THE EXTRACT INTO A VOLUMETRIC FLASK Make up with organic solvent Analyze by GC-MS ***************************************************************************************************************************************************** To Be Continued Page 10 Of 13 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH00361371 Tests Conducted 5 PHTHALATE CONTENT TEST WITH REFERENCE TO CPSC-CH-C1001-09.3, BY GAS CHROMATOGRAPHY-MASS SPECTROMETRY (GC-MS) ANALYSIS. TESTED COMPOUND RESULT (%,W/W) DI-BUTYL PHTHALATE (DBP) DI(2-ETHYL HEXYL) PHTHALATE(DEHP) BENZYL BUTYL PHTHALATE (BBP) REMARK: ND ND ND LIMIT(%,W/W) (MAX.) 0.1 0.1 0.1 DETECTION LIMIT = 0.01%(W/W) ND = NOT DETECTED DATE SAMPLE RECEIVED:JAN.8, 2013 TESTING PERIOD:JAN.8, 2013 TO JAN.11, 2013 ***************************************************************************************************************************************************** To Be Continued Page 11 Of 13 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH00361371 Tests Conducted MEASUREMENT FLOWCHART TEST FOR PHTHALATE CONTENT Weigh sample and place in a thimble Extracted by soxhlet extraction with organic solvent Concentrate the extract TRANSFER THE EXTRACT INTO A VOLUMETRIC FLASK Make up with organic solvent Analyze by GC-MS ***************************************************************************************************************************************************** To Be Continued Page 12 Of 13 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH00361371 Tests Conducted ***************************************************************************************************************************************************** End Of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. Page 13 Of 13 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Applicant: Number : TWNC00282886 Littelfuse Philippines Inc. LIMA Technology Center, Lipa City, Malvar, Batangas Date : Oct 31, 2012 Sample Description: One (1) group of submitted samples said to be : Part Description : sand Part Number : 091250 Date Sample Received : Oct 24, 2012 Date Test Started : Oct 25, 2012 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ0282886* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 1 of 7 Number : TWNC00282886 Test Conducted (Ⅰ) Test Result Summary : Result (ppm) Submitted Samples Test Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Halogen Content Fluorine (F) Chlorine (Cl) Bromine (Br) Iodine (I) ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND Remarks: ppm = Parts per million based on weight of tested sample = mg/kg ND = Not detected Responsibility of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received Test Period : Oct 24, 2012 : Oct 25, 2012 To Oct 30, 2012 *THJ0282886* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 2 of 7 Number : TWNC00282886 Test Conducted (Ⅱ) RoHS Limits: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr6+) Content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ehters (PBDEs) Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from Annex II of 2011/65/EU for homogeneous material. (Ⅲ) Test Method: Test Item Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Test Method With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in annex C, by alkaline digestion and determined by UV-Vis spectrophotometer. Reporting Limit *THJ0282886* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 2 ppm 2 ppm 2 ppm 1 ppm Page 3 of 7 Number : TWNC00282886 Test Conducted (Ⅲ) Test Method: Test Item Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) Halogen Content Test Method With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MS and further HPLC-DAD confirmation when necessary. With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MS and further HPLC-DAD confirmation when necessary. With reference to EN 14582:2007 by calorimetric bomb with oxygen and determined by Ion Chromatograph. Reporting Limit 5 ppm 5 ppm 50 ppm Remark: Reporting limit = Quantitation limit of analyte in sample *THJ0282886* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 4 of 7 Number : TWNC00282886 Test Conducted (Ⅳ) Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents Reference Standard: IEC 62321 edition 1.0:2008 Sample preparation For non-metal part For metal part Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component Cd/Pb/Hg Cr Confirm the tested samples are totally dissolved Make up with deionized water PBBs/PBDEs Polymers / electronics Metal For different material, digest the sample with *1 appropriate acid 6+ Weigh sample and add organic solvent By spot test Negative Get 50cm2 sample By boiling water extraction *2 Weigh sample and add alkaline solution By Soxhlet extraction or Solvent extraction Definite temp. extraction Cool and filter the extract Analyzed by ICP-OES Concentrate the extract and make up with organic solvent Analyzed by GC-MSD Make up with deionized water and add diphenylcarbazide solution Remarks: *1: List of Appropriate Acid: Material Polymers Metals Electronics Analyzed by UV-VIS Acid Added for Digestion HNO3,HCl,HF,H2O2,H3BO3 HNO3,HCl,HF HNO3,HCl,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. *THJ0282886* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 5 of 7 Number : TWNC00282886 Test Conducted (Ⅳ) Measurement Flowchart: Test for Halogen Content Reference Standard:EN 14582 Sampling/grinding or cutting Add absorbent in a combustion flask & place weighed sample in equipment Fill oxygen into calorimetric bomb Ignite then leave the bomb at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. *THJ0282886* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 6 of 7 Number : TWNC00282886 Test Conducted Photo *THJ0282886* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 7 of 7