ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: TE5 Product #: 396xxxxxxx Series Issue Date: June 11, 2012 It is hereby certified by Littelfuse, Inc. that there is neither RoHS (2011/65/EU - recast of EU Directive 2002/95/EC)-restricted substance nor such use, for materials to be used for unit parts, for packing/packaging materials, and for additives and the like in the manufacturing processes. In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing processes, are all composed of the following components. Issued by: <Global EHS Engineer> (1) Parts, sub-materials and unit parts This document covers the TE5 RoHS-Compliant series products manufactured by Littelfuse, Inc. < Raw Materials Used Please see Table 1 (2) The ICP data on all measurable substances Please see appropriate pages as identifed in Table 1 Remarks: Form 585-047 Rev. A 1 2/21/06 Table 1: List of Raw Materials covered by this report Total Parts 1 2 3 4 5 6 Raw Material Part Number DRAG*** (082xxx) 692213 (LOZZ194) 910-017 867-002 009116 6481xx (GLZZXXX) Raw Material Description Element – Ag plated Cu wire Solder Wire Plastic Cap Socket with Pin Ceramic Paper Yarn 2 Page(s) 3-8 9-13 14-22 23-32 33-38 39-44 Intertek Testing Services Ltd., Shanghai TFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338 TEST REPORT APPLICANT: LITTELFUSE,INC. 800 E. NORTHWEST HWY ATTN: A. CESISTA/ K. BACILA NUMBER: SHAH00320463 DATE: JUN 06, 2012 SAMPLE DESCRIPTION: ONE(1) SUBMITTED SAMPLE SAID TO BE WIRE WITH PLATING. PART DESCRIPTION : AG PLATED CU WIRE. PART NUMBER : 082555. DATE SAMPLE RECEIVED : MAY.30, 2012. DATE TEST STARTED : MAY.30, 2012. *********************************************************************** TESTS CONDUCTED: AS REQUESTED BY THE APPLICANT, FOR DETAILS REFER TO ATTACHED PAGE(S) *********************************************************************** TO BE CONTINUED AUTHORIZED BY: FOR INTERTEK TESTING SERVICES LTD., SHANGHAI JACOB LIN GENERAL MANAGER PAGE 1 OF 6 Intertek Testing Services Ltd., Shanghai TFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338 TEST REPORT NUMBER: SHAH00320463 TESTS CONDUCTED (I) TEST RESULT SUMMARY: TESTING ITEM HEAVY METAL CADMIUM (Cd) CONTENT LEAD (Pb) CONTENT MERCURY (Hg) CONTENT CHROMIUM VI (Cr6+) CONTENT (mg/kg WITH 50cm2) TESTING ITEM HEAVY METAL CADMIUM (Cd) CONTENT / PLATING LEAD (Pb) CONTENT / PLATING MERCURY (Hg) CONTENT / PLATING CHROMIUM VI (Cr6+) CONTENT (mg/kg WITH 50cm2) / PLATING RESULT (PPM) (1) ND ND ND NEGATIVE (< 0.02) RESULT (PPM) (2) ND ND ND NEGATIVE (< 0.02) REMARKS: ppm = PARTS PER MILLION = mg/kg ND = NOT DETECTED mg/kg WITH 50cm2 = MILLIGRAM PER KILOGRAM WITH 50 SQUARE CENTIMETRE NEGATIVE = A NEGATIVE TEST RESULT INDICATED POSITIVE OBSERVATION WAS NOT FOUND AT THE TIME OF TESTING. TESTED COMPONENTS: (1) SUBSTRATE. (2) PLATING. *********************************************************************** TO BE CONTINUED PAGE 2 OF 6 Intertek Testing Services Ltd., Shanghai TFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338 TEST REPORT NUMBER: SHAH00320463 TESTS CONDUCTED (II) RoHS REQUIREMENT: RESTRICTED SUBSTANCES CADMIUM (Cd) CONTENT LEAD (Pb) CONTENT MERCURY (Hg) CONTENT CHROMIUM VI (Cr6+) CONTENT POLYBROMINATED BIPHENYLS (PBBs) POLYBROMINATED DIPHENYL EHTERS (PBDEs) LIMITS 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) THE ABOVE LIMITS WERE QUOTED FROM 2002/95/EC AND AMENDMENT 2005/618/EC FOR HOMOGENEOUS MATERIAL. (III) TEST METHOD: TESTING ITEM TESTING METHOD WITH REFERENCE TO IEC 62321 EDITION 1.0:2008 IN CLAUSE 8/9/10, BY CADMIUM (Cd) MICROWAVE DIGESTION UNTIL THE TESTED CONTENT SAMPLES ARE TOTALLY DISSOLVED AND DETERMINED BY ICP-OES. WITH REFERENCE TO IEC 62321 EDITION 1.0:2008 IN CLAUSE 8/9/10, BY LEAD (Pb) CONTENT MICROWAVE DIGESTION UNTIL THE TESTED SAMPLES ARE TOTALLY DISSOLVED AND DETERMINED BY ICP-OES. WITH REFERENCE TO IEC 62321 EDITION 1.0:2008 IN CLAUSE 7, BY MICROWAVE MERCURY (Hg) DIGESTION UNTIL THE TESTED SAMPLES CONTENT ARE TOTALLY DISSOLVED AND DETERMINED BY ICP-OES. WITH REFERENCE TO IEC 62321 EDITION CHROMIUM VI (Cr6+) 1.0:2008 IN ANNEX B, BY BOILING CONTENT WATER EXTRACTION AND DETERMINED BY UV-VIS SPECTROPHOTOMETER. REPORTING LIMIT 2 ppm 2 ppm 2 ppm 0.02 mg/kg WITH 50cm2 REMARK: REPORTING LIMIT = QUANTITATION LIMIT OF ANALYTE IN SAMPLE DATE SAMPLE RECEIVED : JUN.1, 2012 TESTING PERIOD : JUN.1, 2012 TO JUN.4, 2012 *********************************************************************** TO BE CONTINUED PAGE 3 OF 6 Intertek Testing Services Ltd., Shanghai TFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338 TEST REPORT NUMBER: SHAH00320463 TESTS CONDUCTED (IV) MEASUREMENT FLOWCHART: TEST FOR Cd/Pb/Hg/Chromium (VI)/PBBs/PBDEs CONTENTS REFERENCE STANDARD: IEC 62321 EDITION 1.0:2008 sampling/grinding or cutting Cr6+ Cd/Pb/Hg metal weigh sample and for different material, digest the sample with appropriate acid*1 spot test polymers / electronics weigh sample and add alkaline solution PBBs/PBDEs weigh sample and add organic solvent negative*2 confirm the tested samples are totally dissolved No get 50cm2 samples definite temp. extraction boiling water extraction cool and filter the extract soxhlet extraction or solvent extraction make up with deionized water analyzed by ICP-OES make up with deionized water and add diphenylcarbazide solution concentrate the extract and make up with organic solvent analyzed by GCMSD analyzed by UV-VIS *********************************************************************** TO BE CONTINUED PAGE 4 OF 6 Intertek Testing Services Ltd., Shanghai TFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338 TEST REPORT NUMBER: SHAH00320463 TESTS CONDUCTED REMARKS: *1: LIST OF APPROPRIATE ACID: MATERIAL ACID ADDED FOR DIGESTION POLYMERS HNO3,HCl,HF,H2O2,H3BO3 METALS HNO3,HCl,HF ELECTRONICS HNO3,HCl,H2O2,HBF4 *2: IF THE RESULT OF SPOT TEST IS POSITIVE, CHROMIUM VI WOULD BE DETERMINED AS DETECTED. *********************************************************************** TO BE CONTINUED PAGE 5 OF 6 Intertek Testing Services Ltd., Shanghai TFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338 TEST REPORT NUMBER: SHAH00320463 TESTS CONDUCTED *********************************************************************** END OF REPORT PAGE 6 OF 6 Number : TWNC00232330 Test Report Applicant: Littelfuse Philippines Inc. LIMA Technology Center, Lipa City, Malvar, Batangas Date : Nov 18, 2011 Sample Description: One (1) group of submitted samples said to be : Part Description : Solder Part Number : 692213 Date Sample Received : Nov 11, 2011 Date Test Started : Nov 14, 2011 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory. Page 1 of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00232330 Test Conducted (Ⅰ) Test Result Summary : Test Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content (mg/kg with 50cm2) Result (ppm) Silvery Metal ND 92 ND Negative (< 0.02) Remarks: ppm = Parts per million based on weight of tested sample = mg/kg ND = Not detected < = Less than mg/kg with 50cm2 = milligram per kilogram with 50 square centimetre Negative = A negative test result indicated positive observation was not found at the time of Test. Responsibility of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received Test Period : Nov 11, 2011 : Nov 14, 2011 To Nov 17, 2011 (Ⅱ) RoHS Requirement: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr6+) Content Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. Page 2 of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00232330 Test Conducted (Ⅲ) Test Method: Test Item Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Test Method With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in annex B, by boiling water extraction and determined by UV-Vis spectrophotometer. Reporting Limit 2 ppm 2 ppm 2 ppm 0.02 mg/kg with 50cm2 Remark: Reporting limit = Quantitation limit of analyte in sample Page 3 of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00232330 Test Conducted (Ⅳ) Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI) Reference Standard:IEC 62321 edition 1.0:2008 Sample preparation Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component Cd/Pb/Hg Cr Polymers / electronics Metal For different material, digest the sample with *1 appropriate acid By spot test Negative Confirm the tested samples are totally dissolved Make up with deionized water 6+ *2 Weigh sample and add alkaline solution Get 50cm2 sample Definite temp. extraction By boiling water extraction Cool and filter the extract Analyzed by ICP-OES Make up with deionized water and add diphenyl-carbazide solution Remarks: *1: List of Appropriate Acid: Material Polymers Metals Electronics Analyzed by UV-VIS Acid Added for Digestion HNO3,HCl,HF,H2O2,H3BO3 HNO3,HCl,HF HNO3,HCl,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. End of Report Page 4 of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00232330 Test Conducted Photo Page 5 of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Test Report Applicant: Number : TWNC00232331 Littelfuse Philippines Inc. LIMA Technology Center, Lipa City, Malvar, Batangas Date : Nov 18, 2011 Sample Description: One (1) group of submitted samples said to be : Part Description : TE Caps (same with 910-016 TR Caps) Part Number : 910-017 Date Sample Received : Nov 11, 2011 Date Test Started : Nov 14, 2011 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory. Page 1 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00232331 Test Conducted (Ⅰ) Test Result Summary : Test Item Result (ppm) Brown Plastic Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Halogen Content Fluorine (F) Chlorine (Cl) Bromine (Br) Iodine (I) Phthalates Di(2-ethylhexyl) Phthalate (DEHP) Dibutyl Phthalate (DBP) Benzyl Butyl Phthalate (BBP) Others Hexabromocyclododecane (HBCDD) ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND Remarks: ppm = Parts per million based on weight of tested sample = mg/kg ND = Not detected Responsibility of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received Test Period : Nov 11, 2011 : Nov 14, 2011 To Nov 16, 2011 Page 2 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Test Conducted (Ⅱ) RoHS Requirement: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr6+) Content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ehters (PBDEs) Number : TWNC00232331 Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. (Ⅲ) Test Method: Test Item Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Test Method With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICPOES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICPOES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in annex C, by alkaline digestion and determined by UV-Vis spectrophotometer. Reporting Limit 2 ppm 2 ppm 2 ppm 1 ppm Page 3 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00232331 Test Conducted (Ⅲ) Test Method: Test Item Test Method Reporting Limit With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent Polybrominated 5 ppm extraction and determined by GC-MSD Biphenyls (PBBs) and further HPLC confirmation when necessary. With reference to IEC 62321 edition Polybrominated 1.0:2008 in annex A, by solvent 5 ppm Diphenyl Ethers extraction and determined by GC-MSD and further HPLC confirmation when (PBDEs) necessary. With reference to EN 14582:2007 by Halogen Content 50 ppm calorimetric bomb with oxygen and determined by ion chromatography With reference to EN 14372: 2004, by Phthalates solvent extraction and determined by 50 ppm GC-MSD With reference to USEPA 3540C, by Hexabromocyclododecane 10 ppm solvent extraction and determined by (HBCDD) GC-MSD Remark: Reporting limit = Quantitation limit of analyte in sample Page 4 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00232331 Test Conducted (Ⅳ) Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents Reference Standard: IEC 62321 edition 1.0:2008 Sample preparation For non-metal part For metal part Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component Cd/Pb/Hg Cr Confirm the tested samples are totally dissolved Make up with deionized water PBBs/PBDEs Polymers / electronics Metal For different material, digest the sample with *1 appropriate acid 6+ Weigh sample and add organic solvent By spot test Negative Get 50cm2 sample By boiling water extraction *2 Weigh sample and add alkaline solution By Soxhlet extraction or Solvent extraction Definite temp. extraction Cool and filter the extract Analyzed by ICP-OES Concentrate the extract and make up with organic solvent Analyzed by GC-MSD Make up with deionized water and add diphenylcarbazide solution Remarks: *1: List of Appropriate Acid: Material Polymers Metals Electronics Analyzed by UV-VIS Acid Added for Digestion HNO3,HCl,HF,H2O2,H3BO3 HNO3,HCl,HF HNO3,HCl,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. Page 5 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00232331 Test Conducted (Ⅳ) Measurement Flowchart: Test for Halogen Content Reference Standard:EN 14582 Sampling/grinding or cutting Add absorbent in a combustion flask & place weighed sample in equipment Fill oxygen into calorimetric bomb Ignite then leave the flask at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography Page 6 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00232331 Test Conducted (Ⅳ) Measurement Flowchart: Test For Phthalates Contents Reference Method: EN 14372: 2004 Sampling/grinding or cutting Weigh sample and add organic solvent By solvent extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MSD Page 7 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00232331 Test Conducted (Ⅳ) Measurement Flowchart: Test For Hexabromocyclododecane (HBCDD) Reference Standard:USEPA 3540C Sampling/grinding or cutting Weigh sample and add organic solvent By soxhlet extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MSD End of Report Page 8 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00232331 Test Conducted Photo Page 9 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Test Report Applicant: Littelfuse Philippines Inc. LIMA Technology Center, Lipa City, Malvar, Batangas Number : TWNC00256913 Date : May 15, 2012 Sample Description: One (1) group of submitted samples said to be : Part Description : Socket with Pin Part Number : 867-002 Date Sample Received : May 10, 2012 Date Test Started : May 10, 2012 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory. Page 1 of 10 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number: TWNC00256913 Test Conducted (Ⅰ) Test Result Summary : Test Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content (For Non-Metal Material) Chromium VI (Cr6+) content (By Boiling Water Extraction On Metal) (mg/kg with 50cm2) Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Halogen Content Fluorine (F) Chlorine (Cl) Bromine (Br) Iodine (I) (1) Result (ppm) (2) (3) ND ND ND ND ND ND ND ND ND ND -- -- ND Negative (< 0.02)(#) Negative (< 0.02)(#) ND ND ND ND ND ND ND ND ND ND ----------- ----------- ND ND ND ND ND ND ND ND ND ND ----------- ----------- ND ND ND ND ----- ----- Page 2 of 10 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number: TWNC00256913 Test Conducted (Ⅰ) Test Result Summary : Test Item Phthalates Di(2-ethylhexyl) Phthalate (DEHP) Dibutyl Phthalate (DBP) Benzyl Butyl Phthalate (BBP) Others Hexabromocyclododecane (HBCDD) (1) Result (ppm) (2) (3) ND ND ND ---- ---- ND -- -- Remarks: ppm = Parts per million based on weight of tested sample = mg/kg ND = Not detected < = Less than mg/kg with 50cm2 = milligram per kilogram with 50 square centimetre Negative = A negative test result indicated positive observation was not found at the time of Test. # = Due to the insufficient sample area, reduced total sample surface of 25 cm2 was used and the dilution factor was adjusted accordingly. Tested Components: (1) Black Body Part (2) Coppery Metal Substrate (3) Silvery Plating On Metal Pin Responsibility of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received Test Period : May 10, 2012 : May 10, 2012 To May 14, 2012 (Ⅱ) RoHS Requirement: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr6+) Content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ehters (PBDEs) Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. Page 3 of 10 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number: Test Conducted (Ⅲ) Test Method: Test Item TWNC00256913 Test Method With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by Cadmium (Cd) microwave digestion until the tested content samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by Lead (Pb) content microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave Mercury (Hg) digestion until the tested samples are content totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 6+ Chromium VI (Cr ) 1.0:2008 in annex C, by alkaline content (For Nondigestion and determined by UV-Vis Metal Meterial) spectrophotometer. Chromium VI (Cr6+) With reference to IEC 62321 edition content (By Boiling 1.0:2008 in annex B, by boiling water Wter Extraction On extraction and determined by UV-Vis Metal) Spectrophotometer. With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent Polybrominated extraction and determined by GC-MS and Biphenyls (PBBs) further HPLC-DAD confirmation when necessary. With reference to IEC 62321 edition Polybrominated 1.0:2008 in annex A, by solvent Diphenyl Ethers extraction and determined by GC-MS and (PBDEs) further HPLC-DAD confirmation when necessary. With reference to EN 14582:2007 by Halogen Content calorimetric bomb with oxygen and determined by Ion Chromatograph. With reference to EN 14372: 2004, by Phthalates solvent extraction and determined by GC-MS. With reference to USEPA 3540C, by Hexabromocyclodode solvent extraction and determined by cane (HBCDD) GC-MSD. Reporting Limit 2 ppm 2 ppm 2 ppm 1 ppm 0.02 mg/kg with 50cm2 5 ppm 5 ppm 50 ppm 50 ppm 10 ppm Remark: Reporting limit = Quantitation limit of analyte in sample Page 4 of 10 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number: TWNC00256913 Test Conducted (Ⅳ) Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI) Reference Standard:IEC 62321 edition 1.0:2008 Sample preparation Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component Cd/Pb/Hg Cr Polymers / electronics Metal For different material, digest the sample with *1 appropriate acid By spot test Negative Confirm the tested samples are totally dissolved Make up with deionized water 6+ *2 Weigh sample and add alkaline solution Get 50cm2 sample Definite temp. extraction By boiling water extraction Cool and filter the extract Analyzed by ICP-OES Make up with deionized water and add diphenyl-carbazide solution Remarks: *1: List of Appropriate Acid: Material Polymers Metals Electronics Analyzed by UV-VIS Acid Added for Digestion HNO3,HCl,HF,H2O2,H3BO3 HNO3,HCl,HF HNO3,HCl,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. Page 5 of 10 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number: TWNC00256913 Test Conducted (Ⅳ) Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents Reference Standard: IEC 62321 edition 1.0:2008 Sample preparation For non-metal part For metal part Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component Cd/Pb/Hg Cr Weigh sample and add organic solvent By spot test Negative Confirm the tested samples are totally dissolved Make up with deionized water PBBs/PBDEs Polymers / electronics Metal For different material, digest the sample with *1 appropriate acid 6+ Get 50cm2 sample By boiling water extraction *2 Weigh sample and add alkaline solution By Soxhlet extraction or Solvent extraction Definite temp. extraction Cool and filter the extract Analyzed by ICP-OES Concentrate the extract and make up with organic solvent Analyzed by GC-MSD Make up with deionized water and add diphenylcarbazide solution Remarks: *1: List of Appropriate Acid: Material Polymers Metals Electronics Analyzed by UV-VIS Acid Added for Digestion HNO3,HCl,HF,H2O2,H3BO3 HNO3,HCl,HF HNO3,HCl,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. Page 6 of 10 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number: TWNC00256913 Test Conducted (Ⅳ) Measurement Flowchart: Test for Halogen Content Reference Standard:EN 14582 Sampling/grinding or cutting Add absorbent in a combustion flask & place weighed sample in equipment Fill oxygen into calorimetric bomb Ignite then leave the bomb at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography Page 7 of 10 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number: TWNC00256913 Test Conducted (Ⅳ) Measurement Flowchart: Test For Phthalates Contents Reference Method: EN 14372: 2004 Sampling/grinding or cutting Weigh sample and add organic solvent By solvent extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MSD Page 8 of 10 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number: TWNC00256913 Test Conducted (Ⅳ) Measurement Flowchart: Test For Hexabromocyclododecane (HBCDD) Reference Standard:USEPA 3540C Sampling/grinding or cutting Weigh sample and add organic solvent By soxhlet extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MSD End of Report Page 9 of 10 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number: TWNC00256913 Test Conducted Photo Page 10 of Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00232333 Test Report Applicant: Littelfuse Philippines Inc. LIMA Technology Center, Lipa City, Malvar, Batangas Date : Nov 18, 2011 Sample Description: One (1) group of submitted samples said to be : Part Description : Ceramic Paper Part Number : 009116 Date Sample Received : Nov 11, 2011 Date Test Started : Nov 14, 2011 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory. Page 1 of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00232333 Test Conducted (Ⅰ) Test Result Summary : Test Item Result (ppm) White Material Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Halogen Content Fluorine (F) Chlorine (Cl) Bromine (Br) Iodine (I) ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND Remarks: ppm = Parts per million based on weight of tested sample = mg/kg ND = Not detected Responsibility of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received Test Period : Nov 11, 2011 : Nov 14, 2011 To Nov 16, 2011 Page 2 of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Test Conducted (Ⅱ) RoHS Requirement: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr6+) Content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ehters (PBDEs) Number : TWNC00232333 Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. (Ⅲ) Test Method: Test Item Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) Halogen Content Test Method With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in annex C, by alkaline digestion and determined by UV-Vis spectrophotometer. With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary. With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary. With reference to EN 14582:2007 by calorimetric bomb with oxygen and determined by ion chromatography Reporting Limit 2 ppm 2 ppm 2 ppm 1 ppm 5 ppm 5 ppm 50 ppm Remark: Reporting limit = Quantitation limit of analyte in sample Page 3 of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00232333 Test Conducted (Ⅳ) Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents Reference Standard: IEC 62321 edition 1.0:2008 Sample preparation For non-metal part For metal part Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component Cd/Pb/Hg Cr Confirm the tested samples are totally dissolved Make up with deionized water PBBs/PBDEs Polymers / electronics Metal For different material, digest the sample with *1 appropriate acid 6+ Weigh sample and add organic solvent By spot test Negative Get 50cm2 sample By boiling water extraction *2 Weigh sample and add alkaline solution By Soxhlet extraction or Solvent extraction Definite temp. extraction Cool and filter the extract Analyzed by ICP-OES Concentrate the extract and make up with organic solvent Analyzed by GC-MSD Make up with deionized water and add diphenylcarbazide solution Remarks: *1: List of Appropriate Acid: Material Polymers Metals Electronics Analyzed by UV-VIS Acid Added for Digestion HNO3,HCl,HF,H2O2,H3BO3 HNO3,HCl,HF HNO3,HCl,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. Page 4 of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00232333 Test Conducted (Ⅳ) Measurement Flowchart: Test for Halogen Content Reference Standard:EN 14582 Sampling/grinding or cutting Add absorbent in a combustion flask & place weighed sample in equipment Fill oxygen into calorimetric bomb Ignite then leave the flask at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography End of Report Page 5 of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00232333 Test Conducted Photo Page 6 of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00232329 Test Report Applicant: Littelfuse Philippines Inc. LIMA Technology Center, Lipa City, Malvar, Batangas Date : Nov 18, 2011 Sample Description: One (1) group of submitted samples said to be : Part Description : Yarn(GLZZXXX-6481XX) Part Number : 648118 Date Sample Received : Nov 11, 2011 Date Test Started : Nov 14, 2011 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory. Page 1 of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00232329 Test Conducted (Ⅰ) Test Result Summary : Test Item Result (ppm) White Yarn Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Halogen Content Fluorine (F) Chlorine (Cl) Bromine (Br) Iodine (I) ND 7 ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND Remarks: ppm = Parts per million based on weight of tested sample = mg/kg ND = Not detected Responsibility of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received Test Period : Nov 11, 2011 : Nov 14, 2011 To Nov 17, 2011 Page 2 of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00232329 Test Conducted (Ⅱ) RoHS Requirement: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr6+) Content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ehters (PBDEs) Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. (Ⅲ) Test Method: Test Item Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) Halogen Content Test Method With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in annex C, by alkaline digestion and determined by UV-Vis spectrophotometer. With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary. With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary. With reference to EN 14582:2007 by calorimetric bomb with oxygen and determined by ion chromatography Reporting Limit 2 ppm 2 ppm 2 ppm 1 ppm 5 ppm 5 ppm 50 ppm Remark: Reporting limit = Quantitation limit of analyte in sample Page 3 of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00232329 Test Conducted (Ⅳ) Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents Reference Standard: IEC 62321 edition 1.0:2008 Sample preparation For non-metal part For metal part Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component Cd/Pb/Hg Cr Confirm the tested samples are totally dissolved Make up with deionized water PBBs/PBDEs Polymers / electronics Metal For different material, digest the sample with *1 appropriate acid 6+ Weigh sample and add organic solvent By spot test Negative Get 50cm2 sample By boiling water extraction *2 Weigh sample and add alkaline solution By Soxhlet extraction or Solvent extraction Definite temp. extraction Cool and filter the extract Analyzed by ICP-OES Concentrate the extract and make up with organic solvent Analyzed by GC-MSD Make up with deionized water and add diphenylcarbazide solution Analyzed by UV-VIS Remarks: *1: List of Appropriate Acid: Material Polymers Metals Electronics Acid Added for Digestion HNO3,HCl,HF,H2O2,H3BO3 HNO3,HCl,HF HNO3,HCl,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. Page 4 of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00232329 Test Conducted (Ⅳ) Measurement Flowchart: Test for Halogen Content Reference Standard:EN 14582 Sampling/grinding or cutting Add absorbent in a combustion flask & place weighed sample in equipment Fill oxygen into calorimetric bomb Ignite then leave the flask at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography End of Report Page 5 of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00232329 Test Conducted Photo Page 6 of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401