ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: TR5 Product #: 370xxxxx Series Issue Date: January 29, 2013 It is hereby certified by Littelfuse, Inc. that there is neither RoHS (EU Directive 2002/95/EC, 2011/65/EU)-restricted substance nor such use, for materials to be used for unit parts, for packing/packaging materials, and for additives and the like in the manufacturing processes. In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing processes, are all composed of the following components. Issued by: <Global EHS Engineer> (1) Parts, sub-materials and unit parts This document covers the TR5 RoHS-Compliant series products manufactured by Littelfuse, Inc. < Raw Materials Used Please see Table 1 (2) The ICP data on all measurable substances Please see appropriate pages as identifed in Table 1 Remarks: Form 585-047 Rev. A 1 2/21/06 Table 1: List of Raw Materials covered by this report Total Parts 1 2 3 4 5 6 7 Raw Material Part Number DRAGxxx DRCUxxx DRKOxxx LOZZ194/ 692213 T6791/ 910-016 867-00x/ 867-003 KEPA001/ 009116 Raw Material Description Element – Silver plated wires Element – Copper cladded Wires Element – Cu Ni alloys Solder Wire Plastic Cap Socket with Pin Ceramic Paper 2 Page(s) 3-7 8-12 13-17 18-23 24-32 33-42 43-49 Test Report Applicant: Number : TWNC00249179 Littelfuse Philippines Inc. LIMA Technology Center, Lipa City, Malvar, Batangas Date : Mar 28, 2012 Sample Description: One (1) group of submitted samples said to be : Part Description : Silver plated Wire Part Number : DRAGxxx Date Sample Received : Mar 22, 2012 Date Test Started : Mar 22, 2012 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory. Page 1 of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00249179 Test Conducted (Ⅰ) Test Result Summary : Test Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content (mg/kg with 50cm2) Result (ppm) Submitted Samples ND ND ND Negative (< 0.02) Remarks: ppm = Parts per million based on weight of tested sample = mg/kg ND = Not detected < = Less than mg/kg with 50cm2 = milligram per kilogram with 50 square centimetre Negative = A negative test result indicated positive observation was not found at the time of Test. Responsibility of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received Test Period : Mar 22, 2012 : Mar 22, 2012 To Mar 27, 2012 (Ⅱ) RoHS Requirement: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr6+) Content Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. Page 2 of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00249179 Test Conducted (Ⅲ) Test Method: Test Item Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Test Method With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in annex B, by boiling water extraction and determined by UV-Vis Spectrophotometer. Reporting Limit 2 ppm 2 ppm 2 ppm 0.02 mg/kg with 50cm2 Remark: Reporting limit = Quantitation limit of analyte in sample Page 3 of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00249179 Test Conducted (Ⅳ) Measurement Flowchart: Test For Cd/Pb/Hg/Chromium (VI) Reference Standard:IEC 62321 edition 1.0:2008 Sampling/grinding or cutting Cd/Pb/Hg Cr Polymers / Electronics Metal For different material, digest the sample with *1 appropriate acid By spot test Negative Confirm the tested samples are totally dissolved Make up with deionized water 6+ *2 Weigh sample and add alkaline solution Get 50cm2 sample Definite temp. extraction Boiling water extraction Cool and filter the extract Analyzed by ICP-OES Make up with deionized water and add diphenylcarbazide solution Analyzed by UV-VIS Remarks: *1: List Of Appropriate Acid: Material Polymers Metals Electronics Acid Added For Digestion HNO3,HCl,HF,H2O2,H3BO3 HNO3,HCl,HF HNO3,HCl,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. End of Report Page 4 of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00249179 Test Conducted Photo Page 5 of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number: Test Report Applicant: GM ELSCHUKOM ELEKTROSCHUTZKOMPONENTENBAU BH GEWERBESTRASSE 87,D-98669 VEILSDORF, GERMANY Date: SHAH00362299 JAN 18, 2013 Sample Description: Two(2) pieces of submitted samples said to be : (1) Mixed all kinds of metal substrates. (2) Mixed all kinds of plating layers. Item Name : Silver Plated & Pure Silver Wires. Item No. : (1) 101.0132.---- - silver copper alloy wire – AgCu50. (2) 101--232.0--- - tin plated silver copper alloy wire – AgCu50,Sn - -%. Country Of Origin : Germany. ************************************************************************************************************************************************************ Tests Conducted: As requested by the applicant, for details refer to attached page(s). ************************************************************************************************************************************************************ To Be Continued Authorized by: For intertek testing services Ltd., Shanghai Jacob Lin General Manager Page 1 Of 5 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Number: Test Report SHAH00362299 Tests Conducted (A) Test result of RoHS Directive: Result Testing item (1) Cadmium (Cd) content (mg/kg) ND Lead (Pb) content (mg/kg) ND Mercury (Hg) content (mg/kg) ND 6+ Chromium (VI)(Cr ) result (by boiling water extraction on metal) (mg/kg 2 with 50cm ) ND Result Testing item (2) Cadmium (Cd) content (mg/kg) / Plating ND Lead (Pb) content (mg/kg) / Plating 20 Mercury (Hg) content (mg/kg) / Plating ND 6+ Chromium (VI)(Cr ) result (by boiling water extraction on metal) (mg/kg 2 with 50cm ) / Plating ND 2 Remark:mg/kg with 50cm = milligram per kilogram with 50 square centimeter ND = not detected (B) RoHS Requirement: Restricted substances Cadmium (Cd) Lead (Pb) Mercury (Hg) 6+ Chromium (VI) (Cr ) Limits 0.01% (100 mg/kg) 0.1% (1000 mg/kg) 0.1% (1000 mg/kg) 0.1% (1000 mg/kg) The above limits were quoted from RoHS Directive 2011/65/EU for homogeneous material. (C) Test method: Testing item Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content 6+ Chromium (VI) (Cr ) content (for metal) Testing method With reference to IEC 62321 Edition 1.0: 2008, by acid digestion until the tested sample was totally dissolved, and determined by ICP-OES. With reference to IEC 62321 Edition 1.0: 2008, by acid digestion until the tested sample was totally dissolved, and determined by ICP-OES. With reference to IEC 62321 Edition 1.0: 2008, by acid digestion until the tested sample was totally dissolved, and determined by ICP-OES. With reference to IEC 62321 Edition 1.0: 2008, by boiling water extraction and determined by UV-VIS Spectrophotometer. Reporting limit 2 mg/kg 2 mg/kg 2 mg/kg 2 0.02mg/kg with 50cm (in testing solution) Date sample received:Jan.14, 2013 Testing period:Jan.14, 2013 To Jan.17, 2013 ************************************************************************************************************************************************************ To Be Continued Page 2 Of 5 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Number: Test Report SHAH00362299 Tests Conducted (D) Measurement flowchart: Test for Cd/Pb/Hg/Cr (VI)/PBBs/PBDEs contents Reference standard: IEC 62321 Edition 1.0: 2008 Sampling/grinding or cutting Cr Cd/Pb/Hg Metal Weigh sample and for different material, digest the sample with *1 appropriate acid Positive Confirm the tested samples are totally dissolved Yes Get 50cm samples Polymers / electronics PBBs/PBDEs Weigh sample and add alkaline solution Spot test No 6+ Weigh sample and add organic solvent *2 Definite temp. Extraction 2 Boiling water extraction Soxhlet extraction or Solvent extraction Cool and filter the extract Concentrate the extract and make up with organic solvent Make up with deionized water Analyzed by ICP-OES Make up with deionized water and add diphenyl-carbazide solution Analyzed by GC-MSD Analyzed by UV-VIS Remarks: *1: list of appropriate acid: Material Polymers HNO Metals HNO Electronics H Acid added for digestion 3,HCL,HF,H2O2,H3BO3 3,HCL,HF NO3,HCL,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. ************************************************************************************************************************************************************ To Be Continued Page 3 Of 5 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH00362299 Tests Conducted ************************************************************************************************************************************************************ To Be Continued Page 4 Of 5 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Number: SHAH00362299 Tests Conducted ************************************************************************************************************************************************************ End Of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. Page 5 Of 5 Intertek Testing Services Ltd., Shanghai Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 上海天祥質量技術服務有限公司 上海市宜山路 801 號金陵商務廣場 B 座 200233 Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740 www.intertek.com www.intertek.com.cn Test Report Applicant: GM ELSCHUKOM ELEKTROSCHUTZKOMPONENTENBAU BH GEWERBESTRASSE 87,D-98669 VEILSDORF, GERMANY Number: Date: SHAH00362249 JAN 18, 2013 Sample Description: Two(2) pieces of submitted samples said to be : (1)Substrate. (2)Plating. Item Name : Wire With Plating. Item No. : 101 -- 283.0 --- tin plated,copper plated copper nickel alloy wire – Elcon30,Sn --%. Country Of Origin : Germany. ************************************************************************************************************************************************************ Tests Conducted: As requested by the applicant, for details refer to attached page(s). ************************************************************************************************************************************************************ To be continued Authorized by: For intertek testing services Ltd., Shanghai Jacob Lin General Manager Page 1 Of 5 Number: Test Report SHAH00362249 Tests Conducted (A) Test result of RoHS Directive: Testing item Result Cadmium (Cd) content (mg/kg) (1) ND Lead (Pb) content (mg/kg) 43 ND Mercury (Hg) content (mg/kg) 6+ 2 Chromium (VI)(Cr ) result (by boiling water extraction on metal) (mg/kg with 50cm ) ND Result Testing item Cadmium (Cd) content (mg/kg)/Plating (2) ND Lead (Pb) content (mg/kg)/Plating ND Mercury (Hg) content (mg/kg)/Plating ND 6+ ND Chromium (VI)(Cr ) result (by boiling water extraction on metal) (mg/kg with 2 50cm )/Plating 2 Remark:mg/kg with 50cm = milligram per kilogram with 50 square centimeter ND = not detected (B) RoHS Requirement: Restricted substances Cadmium (Cd) Lead (Pb) Mercury (Hg) 6+ Chromium (VI) (Cr ) Limits 0.01% (100 mg/kg) 0.1% (1000 mg/kg) 0.1% (1000 mg/kg) 0.1% (1000 mg/kg) The above limits were quoted from RoHS Directive 2011/65/EU for homogeneous material. (C) Test method: Testing item Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content 6+ Chromium (VI) (Cr ) content (for metal) Testing method With reference to IEC 62321 Edition 1.0: 2008, by acid digestion until the tested sample was totally dissolved, and determined by ICP-OES. With reference to IEC 62321 Edition 1.0: 2008, by acid digestion until the tested sample was totally dissolved, and determined by ICP-OES. With reference to IEC 62321 Edition 1.0: 2008, by acid digestion until the tested sample was totally dissolved, and determined by ICP-OES. With reference to IEC 62321 Edition 1.0: 2008, by boiling water extraction and determined by UV-VIS Spectrophotometer. Reporting limit 2 mg/kg 2 mg/kg 2 mg/kg 0.02mg/kg with 50cm (in testing solution) 2 Date sample received: Jan.14, 2013 Testing period: Jan.14, 2013 To Jan.17, 2013 ************************************************************************************************************************************************************ To be continued Page 2 Of 5 Number: Test Report SHAH00362249 Tests Conducted (D) Measurement flowchart: Test for Cd/Pb/Hg/Cr (VI)/PBBs/PBDEs contents Reference standard: IEC 62321 Edition 1.0: 2008 Sampling/grinding or cutting Cr Cd/Pb/Hg Metal Weigh sample and for different material, digest the sample with *1 appropriate acid Positive Confirm the tested samples are totally dissolved Yes Get 50cm samples Polymers / electronics Weigh sample and add alkaline solution Spot test No 6+ Boiling water extraction Soxhlet extraction or Solvent extraction Cool and filter the extract Make up with deionized water Analyzed by ICP-OES Weigh sample and add organic solvent *2 Definite temp. Extraction 2 PBBs/PBDEs Make up with deionized water and add diphenyl-carbazide solution Concentrate the extract and make up with organic solvent Analyzed by GC-MSD Analyzed by UV-VIS Remarks: *1: list of appropriate acid: Material Polymers HNO Metals HNO Electronics H Acid added for digestion 3,HCL,HF,H2O2,H3BO3 3,HCL,HF NO3,HCL,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. ************************************************************************************************************************************************************ To be continued Page 3 Of 5 Test Report Number: SHAH00362249 Tests Conducted ************************************************************************************************************************************************************ To be continued Page 4 Of 5 Test Report Number: SHAH00362249 Tests Conducted ************************************************************************************************************************************************************ End of report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. Page 5 Of 5 Test Report Applicant: Number : TWNC00282894 Littelfuse Philippines Inc. LIMA Technology Center, Lipa City, Malvar, Batangas Date : Nov 01, 2012 Sample Description: One (1) group of submitted samples said to be : Part Description : Solder wire Part Number : 692213 Date Sample Received : Oct 24, 2012 Date Test Started : Oct 25, 2012 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ0282894* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 1 of 6 Number : TWNC00282894 Test Conducted (Ⅰ) Test Result Summary : Result (ppm) Silvery Metal Wire Test Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content (mg/kg with 50cm2) ND 84 ND Negative (< 0.02) Remarks: ppm = Parts per million based on weight of tested sample = mg/kg ND = Not detected < = Less than mg/kg with 50cm2 = milligram per kilogram with 50 square centimetre Negative = A negative test result indicated positive observation was not found at the time of Test. Responsibility of Chemist : Irene Chiou / Kevin Liu Date Sample Received Test Period : Oct 24, 2012 : Oct 25, 2012 To Nov 01, 2012 (Ⅱ) RoHS Limits: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr6+) Content Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from Annex II of 2011/65/EU for homogeneous material. *THJ0282894* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 2 of 6 Number : TWNC00282894 Test Conducted (Ⅲ) Test Method: Test Item Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Test Method With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in annex B, by boiling water extraction and determined by UV-Vis Spectrophotometer. Reporting Limit 2 ppm 2 ppm 2 ppm 0.02 mg/kg with 50cm2 Remark: Reporting limit = Quantitation limit of analyte in sample *THJ0282894* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 3 of 6 Number : TWNC00282894 Test Conducted (Ⅳ) Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI) Reference Standard:IEC 62321 edition 1.0:2008 Sample preparation Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component Cd/Pb/Hg Cr 6+ Polymers / electronics Metal For different material, digest the sample with *1 appropriate acid By spot test Negative Confirm the tested samples are totally dissolved Make up with deionized water *2 Weigh sample and add alkaline solution Get 50cm2 sample Definite temp. extraction By boiling water extraction Cool and filter the extract Analyzed by ICP-OES Make up with deionized water and add diphenyl-carbazide solution Analyzed by UV-VIS *THJ0282894* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 4 of 6 Number : TWNC00282894 Test Conducted Remarks: *1: List of Appropriate Acid: Material Polymers Metals Electronics Acid Added for Digestion HNO3,HCl,HF,H2O2,H3BO3 HNO3,HCl,HF HNO3,HCl,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. *THJ0282894* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 5 of 6 Number : TWNC00282894 Test Conducted Photo *THJ0282894* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 6 of 6 Test Report Applicant: Number : TWNC00282891 Littelfuse Philippines Inc. LIMA Technology Center, Lipa City, Malvar, Batangas Date : Oct 31, 2012 Sample Description: One (1) group of submitted samples said to be : Part Description : TRTE cap Part Number : 910-017 Date Sample Received : Oct 24, 2012 Date Test Started : Oct 25, 2012 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ0282891* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 1 of 9 Number : TWNC00282891 Test Conducted (Ⅰ) Test Result Summary : Result (ppm) Brown Plastic Test Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Halogen Content Fluorine (F) Chlorine (Cl) Bromine (Br) Iodine (I) ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND *THJ0282891* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 2 of 9 Number : TWNC00282891 Test Conducted (Ⅰ) Test Result Summary : Result (ppm) Brown Plastic Test Item Phthalates Di(2-ethylhexyl) Phthalate (DEHP) Dibutyl Phthalate (DBP) Benzyl Butyl Phthalate (BBP) Others Hexabromocyclododecane (HBCDD) ND ND ND ND Remarks: ppm = Parts per million based on weight of tested sample = mg/kg ND = Not detected Responsibility of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received Test Period : Oct 24, 2012 : Oct 25, 2012 To Oct 30, 2012 (Ⅱ) RoHS Limits: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr6+) Content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ehters (PBDEs) Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from Annex II of 2011/65/EU for homogeneous material. *THJ0282891* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 3 of 9 Number : TWNC00282891 Test Conducted (Ⅲ) Test Method: Test Item Test Method With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by Cadmium (Cd) content microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by Lead (Pb) content microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave Mercury (Hg) content digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition Chromium VI (Cr6+) 1.0:2008 in annex C, by alkaline content digestion and determined by UV-Vis spectrophotometer. With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent Polybrominated extraction and determined by GC-MS Biphenyls (PBBs) and further HPLC-DAD confirmation when necessary. With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent Polybrominated Diphenyl Ethers extraction and determined by GC-MS (PBDEs) and further HPLC-DAD confirmation when necessary. With reference to EN 14582:2007 by Halogen Content calorimetric bomb with oxygen and determined by Ion Chromatograph. With reference to EN 14372: 2004, by Phthalates solvent extraction and determined by GC-MS. Hexabromocyclododecane With reference to USEPA 3540C, by solvent extraction and determined by (HBCDD) GC-MSD. Reporting Limit 2 ppm 2 ppm 2 ppm 1 ppm 5 ppm 5 ppm 50 ppm 50 ppm 10 ppm Remark: Reporting limit = Quantitation limit of analyte in sample *THJ0282891* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 4 of 9 Number : TWNC00282891 Test Conducted (Ⅳ) Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents Reference Standard: IEC 62321 edition 1.0:2008 Sample preparation For non-metal part For metal part Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component Cd/Pb/Hg Cr Confirm the tested samples are totally dissolved Make up with deionized water PBBs/PBDEs Polymers / electronics Metal For different material, digest the sample with *1 appropriate acid 6+ Weigh sample and add organic solvent By spot test Negative Get 50cm2 sample By boiling water extraction *2 Weigh sample and add alkaline solution By Soxhlet extraction or Solvent extraction Definite temp. extraction Cool and filter the extract Analyzed by ICP-OES Concentrate the extract and make up with organic solvent Analyzed by GC-MSD Make up with deionized water and add diphenylcarbazide solution Remarks: *1: List of Appropriate Acid: Material Polymers Metals Electronics Analyzed by UV-VIS Acid Added for Digestion HNO3,HCl,HF,H2O2,H3BO3 HNO3,HCl,HF HNO3,HCl,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. *THJ0282891* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 5 of 9 Number : TWNC00282891 Test Conducted (Ⅳ) Measurement Flowchart: Test for Halogen Content Reference Standard:EN 14582 Sampling/grinding or cutting Add absorbent in a combustion flask & place weighed sample in equipment Fill oxygen into calorimetric bomb Ignite then leave the bomb at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography *THJ0282891* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 6 of 9 Number : TWNC00282891 Test Conducted (Ⅳ) Measurement Flowchart: Test For Phthalates Contents Reference Method: EN 14372: 2004 Sampling/grinding or cutting Weigh sample and add organic solvent By solvent extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MSD *THJ0282891* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 7 of 9 Number : TWNC00282891 Test Conducted (Ⅳ) Measurement Flowchart: Test For Hexabromocyclododecane (HBCDD) Reference Standard:USEPA 3540C Sampling/grinding or cutting Weigh sample and add organic solvent By soxhlet extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MSD End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. *THJ0282891* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 8 of 9 Number : TWNC00282891 Test Conducted Photo *THJ0282891* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 9 of 9 Test Report Applicant: Littelfuse Philippines Inc. LIMA Technology Center, Lipa City, Malvar, Batangas Number : TWNC00256914 Date : May 15, 2012 Sample Description: One (1) group of submitted samples said to be : Part Description : Socket with Pin Part Number : 867-003 Date Sample Received : May 10, 2012 Date Test Started : May 10, 2012 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory. Page 1 of 10 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number: TWNC00256914 Test Conducted (Ⅰ) Test Result Summary : Test Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content (For Non-Metal Material) Chromium VI (Cr6+) content (By Boiling Water Extraction On Metal) (mg/kg with 50cm2) Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Halogen Content Fluorine (F) Chlorine (Cl) Bromine (Br) Iodine (I) (1) Result (ppm) (2) (3) ND ND ND ND ND ND ND ND ND ND -- -- ND Negative (< 0.02)(#) Negative (< 0.02)(#) ND ND ND ND ND ND ND ND ND ND ----------- ----------- ND ND ND ND ND ND ND ND ND ND ----------- ----------- ND ND ND ND ----- ----- Page 2 of 10 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number: TWNC00256914 Test Conducted (Ⅰ) Test Result Summary : Test Item (1) Result (ppm) (2) (3) ND ND ND ---- ---- ND -- -- Phthalates Di(2-ethylhexyl) Phthalate (DEHP) Dibutyl Phthalate (DBP) Benzyl Butyl Phthalate (BBP) Others Hexabromocyclododecane (HBCDD) Remarks: ppm = Parts per million based on weight of tested sample = mg/kg ND = Not detected < = Less than mg/kg with 50cm2 = milligram per kilogram with 50 square centimetre Negative = A negative test result indicated positive observation was not found at the time of Test. # = Due to the insufficient sample area, reduced total sample surface of 25 cm2 was used and the dilution factor was adjusted accordingly. Tested Components: (1) Black Body Part (2) Coppery Metal Substrate (3) Silvery Plating On Metal Pin Responsibility of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received Test Period : May 10, 2012 : May 10, 2012 To May 14, 2012 (Ⅱ) RoHS Requirement: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr6+) Content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ehters (PBDEs) Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. Page 3 of 10 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number: Test Conducted (Ⅲ) Test Method: Test Item TWNC00256914 Test Method With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by Cadmium (Cd) microwave digestion until the tested content samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by Lead (Pb) content microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave Mercury (Hg) digestion until the tested samples are content totally dissolved and determined by ICP-OES. Chromium VI (Cr6+) With reference to IEC 62321 edition content (For Non1.0:2008 in annex C, by alkaline Metal Extraction On digestion and determined by UV-Vis Metal) spectrophotometer. Chromium VI (Cr6+) With reference to IEC 62321 edition content (By Boiling 1.0:2008 in annex B, by boiling water Water Extraction On extraction and determined by UV-Vis Metal) Spectrophotometer. With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent Polybrominated extraction and determined by GC-MS and Biphenyls (PBBs) further HPLC-DAD confirmation when necessary. With reference to IEC 62321 edition Polybrominated 1.0:2008 in annex A, by solvent Diphenyl Ethers extraction and determined by GC-MS and (PBDEs) further HPLC-DAD confirmation when necessary. With reference to EN 14582:2007 by Halogen Content calorimetric bomb with oxygen and determined by Ion Chromatograph. With reference to EN 14372: 2004, by Phthalates solvent extraction and determined by GC-MS. With reference to USEPA 3540C, by Hexabromocyclodode solvent extraction and determined by cane (HBCDD) GC-MSD. Reporting Limit 2 ppm 2 ppm 2 ppm 1 ppm 0.02 mg/kg with 50cm2 5 ppm 5 ppm 50 ppm 50 ppm 10 ppm Remark: Reporting limit = Quantitation limit of analyte in sample Page 4 of 10 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number: TWNC00256914 Test Conducted (Ⅳ) Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI) Reference Standard:IEC 62321 edition 1.0:2008 Sample preparation Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component Cd/Pb/Hg Cr Polymers / electronics Metal For different material, digest the sample with *1 appropriate acid By spot test Negative Confirm the tested samples are totally dissolved Make up with deionized water 6+ *2 Weigh sample and add alkaline solution Get 50cm2 sample Definite temp. extraction By boiling water extraction Cool and filter the extract Analyzed by ICP-OES Make up with deionized water and add diphenyl-carbazide solution Remarks: *1: List of Appropriate Acid: Material Polymers Metals Electronics Analyzed by UV-VIS Acid Added for Digestion HNO3,HCl,HF,H2O2,H3BO3 HNO3,HCl,HF HNO3,HCl,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. Page 5 of 10 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number: TWNC00256914 Test Conducted (Ⅳ) Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents Reference Standard: IEC 62321 edition 1.0:2008 Sample preparation For non-metal part For metal part Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component Cd/Pb/Hg Cr Weigh sample and add organic solvent By spot test Negative Confirm the tested samples are totally dissolved Make up with deionized water PBBs/PBDEs Polymers / electronics Metal For different material, digest the sample with *1 appropriate acid 6+ Get 50cm2 sample By boiling water extraction *2 Weigh sample and add alkaline solution By Soxhlet extraction or Solvent extraction Definite temp. extraction Cool and filter the extract Analyzed by ICP-OES Concentrate the extract and make up with organic solvent Analyzed by GC-MSD Make up with deionized water and add diphenylcarbazide solution Analyzed by UV-VIS Remarks: *1: List of Appropriate Acid: Material Polymers Metals Electronics Acid Added for Digestion HNO3,HCl,HF,H2O2,H3BO3 HNO3,HCl,HF HNO3,HCl,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. Page 6 of 10 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number: TWNC00256914 Test Conducted (Ⅳ) Measurement Flowchart: Test for Halogen Content Reference Standard:EN 14582 Sampling/grinding or cutting Add absorbent in a combustion flask & place weighed sample in equipment Fill oxygen into calorimetric bomb Ignite then leave the bomb at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography Page 7 of 10 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number: TWNC00256914 Test Conducted (Ⅳ) Measurement Flowchart: Test For Phthalates Contents Reference Method: EN 14372: 2004 Sampling/grinding or cutting Weigh sample and add organic solvent By solvent extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MSD Page 8 of 10 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number: TWNC00256914 Test Conducted (Ⅳ) Measurement Flowchart: Test For Hexabromocyclododecane (HBCDD) Reference Standard:USEPA 3540C Sampling/grinding or cutting Weigh sample and add organic solvent By soxhlet extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MSD End of Report Page 9 of 10 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number: TWNC00256914 Test Conducted Photo Page 10 of Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Test Report Applicant: Number : TWNC00282889 Littelfuse Philippines Inc. LIMA Technology Center, Lipa City, Malvar, Batangas Date : Oct 31, 2012 Sample Description: One (1) group of submitted samples said to be : Part Description : Ceramic paper Part Number : 009116 Date Sample Received : Oct 24, 2012 Date Test Started : Oct 25, 2012 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ0282889* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 1 of 7 Number : TWNC00282889 Test Conducted (Ⅰ) Test Result Summary : Result (ppm) White Ceramic Paper Test Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Halogen Content Fluorine (F) Chlorine (Cl) Bromine (Br) Iodine (I) ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND Remarks: ppm = Parts per million based on weight of tested sample = mg/kg ND = Not detected Responsibility of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received Test Period : Oct 24, 2012 : Oct 25, 2012 To Oct 30, 2012 *THJ0282889* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 2 of 7 Number : TWNC00282889 Test Conducted (Ⅱ) RoHS Limits: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr6+) Content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ehters (PBDEs) Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from Annex II of 2011/65/EU for homogeneous material. (Ⅲ) Test Method: Test Item Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Test Method With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in annex C, by alkaline digestion and determined by UV-Vis spectrophotometer. Reporting Limit *THJ0282889* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 2 ppm 2 ppm 2 ppm 1 ppm Page 3 of 7 Number : TWNC00282889 Test Conducted (Ⅲ) Test Method: Test Item Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) Halogen Content Test Method With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MS and further HPLC-DAD confirmation when necessary. With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MS and further HPLC-DAD confirmation when necessary. With reference to EN 14582:2007 by calorimetric bomb with oxygen and determined by Ion Chromatograph. Reporting Limit 5 ppm 5 ppm 50 ppm Remark: Reporting limit = Quantitation limit of analyte in sample *THJ0282889* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 4 of 7 Number : TWNC00282889 Test Conducted (Ⅳ) Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents Reference Standard: IEC 62321 edition 1.0:2008 Sample preparation For non-metal part For metal part Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component Cd/Pb/Hg Cr Confirm the tested samples are totally dissolved Make up with deionized water PBBs/PBDEs Polymers / electronics Metal For different material, digest the sample with *1 appropriate acid 6+ Weigh sample and add organic solvent By spot test Negative Get 50cm2 sample By boiling water extraction *2 Weigh sample and add alkaline solution By Soxhlet extraction or Solvent extraction Definite temp. extraction Cool and filter the extract Analyzed by ICP-OES Concentrate the extract and make up with organic solvent Analyzed by GC-MSD Make up with deionized water and add diphenylcarbazide solution Remarks: *1: List of Appropriate Acid: Material Polymers Metals Electronics Analyzed by UV-VIS Acid Added for Digestion HNO3,HCl,HF,H2O2,H3BO3 HNO3,HCl,HF HNO3,HCl,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. *THJ0282889* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 5 of 7 Number : TWNC00282889 Test Conducted (Ⅳ) Measurement Flowchart: Test for Halogen Content Reference Standard:EN 14582 Sampling/grinding or cutting Add absorbent in a combustion flask & place weighed sample in equipment Fill oxygen into calorimetric bomb Ignite then leave the bomb at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. *THJ0282889* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 6 of 7 Number : TWNC00282889 Test Conducted Photo *THJ0282889* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 7 of 7