ICPTest_462_11 30 2012 pdf

ICP Test Report Certification Packet
Company name :
Littelfuse, Inc.
Product Series:
NANO Fuse
Product #:
462 SERIES
Issue Date:
November 30, 2012
It is hereby certified by Littelfuse, Inc. that there is neither RoHS (EU Directive 2002/95/EC,
2011/65/EU)-restricted substance nor such use, for materials to be used for unit parts, for
packing/packaging materials, and for additives and the like in the manufacturing processes.
In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used
for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing
processes, are all composed of the following components.
Issued by:
<Global EHS Engineer>
(1) Parts, sub-materials and unit parts
This document covers the
462--Nano
RoHS-Compliant series products manufactured
by Littelfuse, Inc.
< Raw Materials Used
Please see Table 1
(2) The ICP data on all measurable substances
Please see appropriate pages as identifed in Table 1
Remarks:
1
Table 1: List of Raw Materials covered by this report
Total Parts
1
2
3
4
5
6
Form 585-047 Rev. A
Raw Material Part Number
910-280
909-438
901-311
901-310
DRFE-001,2,3,5 (497303-001)
DRAG (082719-001)
2
Raw Material Description
Cap
Plastic Tube
Silicon Square Profile
Silicon Round Profile
Wire-Sn Plated NiFeMCu
Wire-Sn Plated AgCu
Page(s)
3-8
9-19
20-29
30-38
39-45
46-50
2/21/06
Test Report
Applicant:
Number : TWNC00285775
Littelfuse Philippines Inc.
LIMA Technology Center, Lipa City,
Malvar, Batangas
Date
: Nov 19, 2012
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: Cap
Part Number
: 910-280
Date Sample Received
: Nov 12, 2012
Date Test Started
: Nov 13, 2012
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
*THJ0285775*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 1 of 6
Number : TWNC00285775
Test Conducted
(Ⅰ) Test Result Summary :
Result (ppm)
(1)
(2)
Test Item
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content (mg/kg with 50cm2)
ND
ND
ND
Negative
(< 0.02)
ND
ND
ND
Negative
(< 0.02)
Remarks: ppm = Parts per million based on weight of tested sample = mg/kg
ND = Not detected
<
= Less than
mg/kg with 50cm2 = milligram per kilogram with 50 square centimetre
Negative = A negative test result indicated positive observation
was not found at the time of Test.
Tested Components
(1) Coppery metal base material
(2) Silvery plating layer
Responsibility of Chemist : Irene Chiou / Kevin Liu
Date Sample Received
Test Period
: Nov 12, 2012
: Nov 13, 2012 to Nov 16, 2012
(Ⅱ) RoHS Limits:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from Annex II of 2011/65/EU for homogeneous
material.
*THJ0285775*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 2 of 6
Number : TWNC00285775
Test Conducted
(Ⅲ) Test Method:
Test Item
Cadmium (Cd)
content
Lead (Pb) content
Mercury (Hg)
content
Chromium VI (Cr6+)
content
Test Method
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 7, by microwave
digestion until the tested samples are
totally dissolved and determined by
ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in annex B, by boiling water
extraction and determined by UV-Vis
Spectrophotometer.
Reporting Limit
2 ppm
2 ppm
2 ppm
0.02
mg/kg with 50cm2
Remark: Reporting limit = Quantitation limit of analyte in sample
*THJ0285775*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 3 of 6
Number : TWNC00285775
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Cd/Pb/Hg/Chromium (VI)
Reference Standard:IEC 62321 edition 1.0:2008
Sample preparation
Take sample and immerse into Aqua Regia, start to strip plating layer
Stop the stripping procedure upon color change completely
Take the Aqua solution as plating component and stripped body as substrate component
Cd/Pb/Hg
Substrate
Plating
For different
material, digest
the sample with
*1
appropriate acid
Cr
6+
By spot test
Confirm the tested
samples are
totally dissolved
Make up with
deionized water
Negative
*2
Get 50cm2 sample
By boiling water
extraction
Analyzed by ICP-OES
Make up with deionized water and add
diphenyl-carbazide solution
Analyzed by UV-VIS
*THJ0285775*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 4 of 6
Number : TWNC00285775
Test Conducted
Remarks:
*1: List Of Appropriate Acid:
Material
Polymers
Metals
Electronics
Acid Added For Digestion
HNO3,HCl,HF,H2O2,H3BO3
HNO3,HCl,HF
HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected.
End of Report
This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a
recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than
the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions
governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this
report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not
accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in
the event of our gross negligence or wilful misconduct.
*THJ0285775*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 5 of 6
Number : TWNC00285775
Test Conducted
Photo
*THJ0285775*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 6 of 6
Test Report
Applicant:
Number : TWNC00285763
Littelfuse Philippines Inc.
LIMA Technology Center, Lipa City,
Malvar, Batangas
Date
: Nov 19, 2012
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: Silicon Round
Part Number
: 910-311
Date Sample Received
: Nov 12, 2012
Date Test Started
: Nov 13, 2012
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
*THJ0285763*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 1 of 10
Number : TWNC00285763
Test Conducted
(Ⅰ) Test Result Summary :
Result (ppm)
Dark ked silicon
Test Item
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content
Polybrominated Biphenyls (PBBs)
Monobrominated Biphenyls (MonoBB)
Dibrominated Biphenyls (DiBB)
Tribrominated Biphenyls (TriBB)
Tetrabrominated Biphenyls (TetraBB)
Pentabrominated Biphenyls (PentaBB)
Hexabrominated Biphenyls (HexaBB)
Heptabrominated Biphenyls (HeptaBB)
Octabrominated Biphenyls (OctaBB)
Nonabrominated Biphenyls (NonaBB)
Decabrominated Biphenyl (DecaBB)
Polybrominated Diphenyl Ethers (PBDEs)
Monobrominated Diphenyl Ethers (MonoBDE)
Dibrominated Diphenyl Ethers (DiBDE)
Tribrominated Diphenyl Ethers (TriBDE)
Tetrabrominated Diphenyl Ethers (TetraBDE)
Pentabrominated Diphenyl Ethers (PentaBDE)
Hexabrominated Diphenyl Ethers (HexaBDE)
Heptabrominated Diphenyl Ethers (HeptaBDE)
Octabrominated Diphenyl Ethers (OctaBDE)
Nonabrominated Diphenyl Ethers (NonaBDE)
Decabrominated Diphenyl Ether (DecaBDE)
Halogen Content
Fluorine (F)
Chlorine (Cl)
Bromine (Br)
Iodine (I)
Phthalates
Di(2-ethylhexyl) Phthalate (DEHP)
Dibutyl Phthalate (DBP)
Benzyl Butyl Phthalate (BBP)
Others
Hexabromocyclododecane (HBCDD)
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
453
ND
ND
ND
ND
ND
ND
Remarks: ppm = Parts per million based on weight of tested sample = mg/kg
ND = Not detected
Responsibility of Chemist : Irene Chiou / Kevin Liu / Cathy Chen
Date Sample Received
Test Period
: Nov 12, 2012
: Nov 13, 2012 to Nov 16, 2012
*THJ0285763*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 2 of 10
Number : TWNC00285763
Test Conducted
(Ⅱ) RoHS Limits:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Polybrominated Biphenyls (PBBs)
Polybrominated Diphenyl Ehters (PBDEs)
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from Annex II of 2011/65/EU for homogeneous
material.
(Ⅲ) Test Method:
Test Item
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+)
content
Reporting Limit
Test Method
With reference to IEC 62321
edition 1.0:2008 in clause 8/9/10,
by microwave digestion until the
2 ppm
tested samples are totally
dissolved and determined by ICPOES.
With reference to IEC 62321
edition 1.0:2008 in clause 8/9/10,
by microwave digestion until the
2 ppm
tested samples are totally
dissolved and determined by ICPOES.
With reference to IEC 62321
edition 1.0:2008 in clause 7, by
microwave digestion until the
2 ppm
tested samples are totally
dissolved and determined by ICPOES.
With reference to IEC 62321 edition
1.0:2008 in annex C, by alkaline
1 ppm
digestion and determined by UV-Vis
spectrophotometer.
*THJ0285763*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 3 of 10
Number : TWNC00285763
Test Conducted
(Ⅲ) Test Method:
Test Item
Test Method
With reference to IEC 62321
edition 1.0:2008 in annex A, by
Polybrominated
solvent extraction and determined
Biphenyls (PBBs)
by GC-MS and further HPLC-DAD
confirmation when necessary.
With reference to IEC 62321
edition 1.0:2008 in annex A, by
Polybrominated Diphenyl
solvent extraction and determined
Ethers (PBDEs)
by GC-MS and further HPLC-DAD
confirmation when necessary.
With reference to EN 14582:2007 by
Halogen Content
calorimetric bomb with oxygen and
determined by Ion Chromatograph.
With reference to EN 14372: 2004,
Phthalates
by solvent extraction and
determined by GC-MS.
With reference to USEPA 3540C, by
Hexabromocyclododecane
solvent extraction and determined
(HBCDD)
by GC-MS.
Reporting Limit
5 ppm
5 ppm
50 ppm
50 ppm
10 ppm
Remark: Reporting limit = Quantitation limit of analyte in sample
*THJ0285763*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 4 of 10
Number : TWNC00285763
Test Conducted
(Ⅳ) Measurement Flowchart:
Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents
Reference Standard: IEC 62321 edition 1.0:2008
Sample preparation
For non-metal part
For metal part
Take sample and immerse into Aqua Regia, start to strip plating layer
Stop the stripping procedure upon color change completely
Take the Aqua solution as plating component and stripped body as substrate component
PBBs/PBDEs
Weigh sample and
add organic solvent
By Soxhlet
extraction or
Solvent extraction
Concentrate the
extract and make up
with organic
solvent
Analyzed by GC-MSD
Cr
6+
Substrate
Cd/Pb/Hg
Weigh sample
and add
alkaline
solution
For different
material, digest
the sample with
*1
appropriate acid
Plating
Cr
6+
By spot test
Definite temp.
extraction
Cool and filter
the extract
Confirm the tested
samples are
totally dissolved
Negative
*2
Get 50cm2 sample
Make up with
deionized water
By boiling water
extraction
Analyzed by ICP-OES
Make up with deionized
water and add
diphenyl-carbazide
solution
Analyzed by UV-VIS
*THJ0285763*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 5 of 10
Number : TWNC00285763
Test Conducted
Remarks:
*1: List of Appropriate Acid:
Material
Polymers
Metals
Electronics
Acid Added for Digestion
HNO3,HCl,HF,H2O2,H3BO3
HNO3,HCl,HF
HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected.
*THJ0285763*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 6 of 10
Number : TWNC00285763
Test Conducted
(Ⅳ) Measurement Flowchart:
Test for Halogen Content
Reference Standard:EN 14582
Sampling/grinding or
cutting
Add absorbent in a
combustion flask &
place weighed sample in
equipment
Fill oxygen into
calorimetric bomb
Ignite then leave the
bomb at room
temperature
Transfer the absorbent
into a volumetric flask
Make up with deionized
water
Analyzed by ion
chromatography
*THJ0285763*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 7 of 10
Number : TWNC00285763
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Phthalates Contents
Reference Method: EN 14372: 2004
Sampling/grinding or
cutting
Weigh sample and add
organic solvent
By solvent extraction
Concentrate the extract
and make up with
organic solvent
Analyzed by GC-MSD
*THJ0285763*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 8 of 10
Number : TWNC00285763
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Hexabromocyclododecane (HBCDD)
Reference Standard:USEPA 3540C
Sampling/grinding or cutting
Weigh sample and add
organic solvent
By soxhlet extraction
Concentrate the extract and
make up with organic solvent
Analyzed by GC-MSD
End of Report
This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a
recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than
the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions
governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this
report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not
accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in
the event of our gross negligence or wilful misconduct.
*THJ0285763*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 9 of 10
Number : TWNC00285763
Test Conducted
Photo
*THJ0285763*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 10 of 10
Test Report
Applicant:
Number : TWNC00285762
Littelfuse Philippines Inc.
LIMA Technology Center, Lipa City,
Malvar, Batangas
Date
: Nov 19, 2012
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: Silicon Square
Part Number
: 901-310
Date Sample Received
: Nov 12, 2012
Date Test Started
: Nov 13, 2012
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
*THJ0285762*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 1 of 9
Number : TWNC00285762
Test Conducted
(Ⅰ) Test Result Summary :
Result (ppm)
Dark Red Silicon
Test Item
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content
Polybrominated Biphenyls (PBBs)
Monobrominated Biphenyls (MonoBB)
Dibrominated Biphenyls (DiBB)
Tribrominated Biphenyls (TriBB)
Tetrabrominated Biphenyls (TetraBB)
Pentabrominated Biphenyls (PentaBB)
Hexabrominated Biphenyls (HexaBB)
Heptabrominated Biphenyls (HeptaBB)
Octabrominated Biphenyls (OctaBB)
Nonabrominated Biphenyls (NonaBB)
Decabrominated Biphenyl (DecaBB)
Polybrominated Diphenyl Ethers (PBDEs)
Monobrominated Diphenyl Ethers (MonoBDE)
Dibrominated Diphenyl Ethers (DiBDE)
Tribrominated Diphenyl Ethers (TriBDE)
Tetrabrominated Diphenyl Ethers (TetraBDE)
Pentabrominated Diphenyl Ethers (PentaBDE)
Hexabrominated Diphenyl Ethers (HexaBDE)
Heptabrominated Diphenyl Ethers (HeptaBDE)
Octabrominated Diphenyl Ethers (OctaBDE)
Nonabrominated Diphenyl Ethers (NonaBDE)
Decabrominated Diphenyl Ether (DecaBDE)
Halogen Content
Fluorine (F)
Chlorine (Cl)
Bromine (Br)
Iodine (I)
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
242
ND
ND
*THJ0285762*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 2 of 9
Number : TWNC00285762
Test Conducted
(Ⅰ) Test Result Summary :
Result (ppm)
Dark Red Silicon
Test Item
Phthalates
Di(2-ethylhexyl) Phthalate (DEHP)
Dibutyl Phthalate (DBP)
Benzyl Butyl Phthalate (BBP)
Others
Hexabromocyclododecane (HBCDD)
ND
ND
ND
ND
Remarks: ppm = Parts per million based on weight of tested sample = mg/kg
ND = Not detected
Responsibility of Chemist : Irene Chiou / Kevin Liu / Cathy Chen
Date Sample Received
Test Period
: Nov 12, 2012
: Nov 13, 2012 To Nov 16, 2012
(Ⅱ) RoHS Limits:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Polybrominated Biphenyls (PBBs)
Polybrominated Diphenyl Ehters (PBDEs)
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from Annex II of 2011/65/EU for homogeneous
material.
*THJ0285762*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 3 of 9
Number : TWNC00285762
Test Conducted
(Ⅲ) Test Method:
Test Item
Test Method
Reporting
Limit
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
Cadmium (Cd) content
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
Lead (Pb) content
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 7, by microwave
Mercury (Hg) content
digestion until the tested samples
are totally dissolved and determined
by ICP-OES.
With reference to IEC 62321 edition
Chromium VI (Cr6+)
1.0:2008 in annex C, by alkaline
content
digestion and determined by UV-Vis
spectrophotometer.
With reference to IEC 62321 edition
1.0:2008 in annex A, by solvent
Polybrominated
extraction and determined by GC-MS
Biphenyls (PBBs)
and further HPLC-DAD confirmation
when necessary.
With reference to IEC 62321 edition
1.0:2008 in annex A, by solvent
Polybrominated Diphenyl extraction and determined by GC-MS
Ethers (PBDEs)
and further HPLC-DAD confirmation
when necessary.
With reference to EN 14582:2007 by
Halogen Content
calorimetric bomb with oxygen and
determined by Ion Chromatograph.
With reference to EN 14372: 2004, by
Phthalates
solvent extraction and determined by
GC-MS.
Hexabromocyclododecane With reference to USEPA 3540C, by
solvent extraction and determined by
(HBCDD)
GC-MS.
2 ppm
2 ppm
2 ppm
1 ppm
5 ppm
5 ppm
50 ppm
50 ppm
10 ppm
Remark: Reporting limit = Quantitation limit of analyte in sample
*THJ0285762*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 4 of 9
Number : TWNC00285762
Test Conducted
(Ⅳ) Measurement Flowchart:
Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents
Reference Standard: IEC 62321 edition 1.0:2008
Sample preparation
For non-metal part
For metal part
Take sample and immerse into Aqua Regia, start to strip plating layer
Stop the stripping procedure upon color change completely
Take the Aqua solution as plating component and stripped body as substrate component
PBBs/PBDEs
Weigh sample and
add organic solvent
By Soxhlet
extraction or
Solvent extraction
Concentrate the
extract and make up
with organic
solvent
Analyzed by GC-MSD
Cr
6+
Substrate
Cd/Pb/Hg
Weigh sample
and add
alkaline
solution
For different
material, digest
the sample with
*1
appropriate acid
Plating
Cr
6+
By spot test
Definite temp.
extraction
Cool and filter
the extract
Confirm the tested
samples are
totally dissolved
Negative
*2
Get 50cm2 sample
Make up with
deionized water
By boiling water
extraction
Analyzed by ICP-OES
Make up with deionized
water and add
diphenyl-carbazide
solution
Analyzed by UV-VIS
Remarks:
*1: List of Appropriate Acid:
Acid Added for Digestion
Material
Polymers
HNO3,HCl,HF,H2O2,H3BO3
Metals
HNO3,HCl,HF
Electronics
HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected.
*THJ0285762*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 5 of 9
Number : TWNC00285762
Test Conducted
(Ⅳ) Measurement Flowchart:
Test for Halogen Content
Reference Standard:EN 14582
Sampling/grinding or
cutting
Add absorbent in a
combustion flask &
place weighed sample in
equipment
Fill oxygen into
calorimetric bomb
Ignite then leave the
bomb at room
temperature
Transfer the absorbent
into a volumetric flask
Make up with deionized
water
Analyzed by ion
chromatography
*THJ0285762*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 6 of 9
Number : TWNC00285762
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Phthalates Contents
Reference Method: EN 14372: 2004
Sampling/grinding or
cutting
Weigh sample and add
organic solvent
By solvent extraction
Concentrate the extract
and make up with
organic solvent
Analyzed by GC-MSD
*THJ0285762*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 7 of 9
Number : TWNC00285762
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Hexabromocyclododecane (HBCDD)
Reference Standard:USEPA 3540C
Sampling/grinding or cutting
Weigh sample and add
organic solvent
By soxhlet extraction
Concentrate the extract and
make up with organic solvent
Analyzed by GC-MSD
End of Report
This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a
recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than
the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions
governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this
report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not
accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in
the event of our gross negligence or wilful misconduct.
*THJ0285762*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 8 of 9
Number : TWNC00285762
Test Conducted
Photo
*THJ0285762*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 9 of 9
Validi
nown
ForQues
P|easeU
TestReport
No.: CE/2011i84956
l
Th€followingsampl€(s)was/w6resubmitt€d and identified by/on b€halfofthe client as:
SampleDescdption
Buyer/Order
No.
SampleReceiving
Date
TesiingPeriod
Ni42Fe5SMCuMSn
'10-1185
2011t11t25
2011| 11n5 10 2011t12tol
Pleasereferto nextpage(s).
T€atR€ault(s)
Efn d fe.rd
Ct rdcJ L.bor.tory- rupd
r,rllj"ili!nrl.i f i lR 11{.11
cdoaiy 1l r1irr!.f-li
ii,"iJ"1.!'ji!*';Jul;"c".p"nysgb]edbbcsi*dcdndi6i3ds
aao conoro* o aa
so,eit o i"-"
iii.aonc
ro*a ai'-s.
,a*i.in*r -,t
e"sa*
rec)rosbdft€G{ctod€ndber
I!l 4n'!rtn,{
**";
"r'i,
i ' r iisft
. o m*o
. u "o,,"-.
l i ' t o c " '**,,h"
" . " t , d " *B d a ' ' y T i . " c " ' p . r y 3 $ b 6
i" o te o^cn reeri o' a
"r*r
Page:'1of7
Dale:2O11|1ZO1
POLYFIL
AG
OBERALLMENDSTMSSE
2OA.CH$3OO
ZUG/ SWITZERLAND
L l Il?
1iI' ItrlII'l+46lo?)'ee
ithscs
[t[[l[ttl]l
Test Report
No.: CE/201
1/84956
Dale:2011t1201
Page:2 of 7
POLYFIL
AG
OBEMLLMENDSTMSSE
2OA,CH63OO
ZUG/ SWITZERLAND
ll]ttutflflttl
T€at Resultls)
PARTl.lAMENo.1
T6st ltem(s)
uaomrum(qd)
Lead (Pb)
Mercury
(Hg)
Hexavalent
Chrornium
Cr(Vl)
Sum ot PBBS
Monobromobiphenyl
Dibromobrphenyl
Triblomobiphenyl
Tetrabromobiphenyl
Pentabromobiphenyl
Hexabromobiphenyl
Heptabromobiphenyl
Octabromobiphenyl
Nonabromobiphenyl
Decabromobiphenyl
Sumof PBOEa
Monobromodiphenyl
ether
Dibromodiphonyl
ether
Tribromodiphenyl
ether
Tetrabromodiphenyl
ether
Pentabromodiphenyl
ether
Hexabromodiphenyl
ether
Heptabromodiphenyl
ether
SILVERCOLORED
IJETALWIRE(NCLUDING
THEPLATING
LAYER)
Unit
Method
IIIDL
mg/Kg Withreference
to tEC62321:zl08 and-
Result
No.l
pedonned
by ICP-AES.
mgikS Withreference
to tEC62321:2008€nd
perfomedby ICP-AES_
2
n.o.
2
62
mg/kg With referenc€to IEC 62321: 2008 and
performedby ICP-AES.
2
n.d.
Wilhreference
to IEC62321:2008and
performedby Boilingwaterextrection
Method.#
Negative
5
5
5
5
With referenceto IEC62321: 2008and
mg/Kg p€rformed
by GC/[,S.
5
5
n.o,
n.d.
n,d,
n.d.
n.d.
n.d.
n.d.
n.dn.d.
n.d.
n.o.
n.d.
5
5
5
n,o,
5
n.d.
5
5
5
n.d.
n.d.
Octabromodiphenyl
elher
5
NonabromodiDhenvl
ether
Decabromodiphenyl
ether
n.d.
5
n.d.
n.d.
5
cffip.dy hr | 1 lr'rf;ri
r,1'riiilt,itJ.r
rt,..t]i
*1{J1i
Tb€doons'csFbysecdnPanysuqedbcoseE|cdndloi3olsefuepinbdovsdeat6V6ibdeo.€q
iidbol€p.du€dercplmigl.wbou
Lfi!-*. rir i: rk!, i,,t + s6 t0r)rre
n.d.
n.d.
n.d.
Test Report
No. : CE/2011/84956
Page: 3 of 7
Ode :2O114ZO1
POLYFILAG
OBEMLLMENDSTRASSE2OA,CH€3OOZUG / SWITZERLAND
Tost ltem(s)
Halogen
Halogen-Fluorine
(F)
(CASNo.r14762-94-8)
Halogen-Chlorine
(Cl)
(CASNo.:22537-15-1)
Halogen-Bromine
(Bt
(CASNo.:10097-32-2)
Unit
[[||||l|||m|lrll]l
Method
MDL
With referenceto BS EN 14582..2007.
mg/Kg
Analysis
wasperfomedby lC.
Halogenlodine
(l)
(CASNo.:14362-44-8)
Result
No.1
50
n.d.
50
n.d.
50
n.d.
50
n.d.
Note :
1. mg/kg= ppm; 0.1M%= lOOOppm
2. n.d. = Not Detected
3. MDL= MethodDetection
Limit
4."-"=NotRegulated
5. " = Qualitative
(NoUnit)
analysas
=
6. # a. Positivemeansthe presenceof CA/l on the testedareas
b. Negativemeansthe absenceof CrVlon the testedareas
Thedetected
concentration
in boiling-water-€xt€ction
sorrition
is equaror greaterthan
o.02mg/kgwith50cm,
testedareas,
T Thesample(s)
was^rcreanaryzed
on beharfof theappric€nt
as mixingsamprein onetesting.Theaboveresurt(s)
wEsl^/ere
onlygivenas the infomalityvatue.
c o m p a r yi ! ,
1 ,r j r l , ! , i ' i r - r lj i l l j l i f t
[email protected]'gedby6ecompa
L L . L .t f
lt!!L\
mpreG)
resbdrh3 b..6odd €ndorb
i !r.,.,r rji,,f,.!.
o-.ai'edo,n"i
-
. . ' " ' , o ". d * . ; r s - . . 4 D . a ' . 0
\
Test Report
No. : CE/201'1/84956
Page: 4 of 7
Da1e| 2O1112JO1
POLYFILAG
OBERALLMENDSTMSSE2OA,CH{3OOZUG / SWITZERLAND
rtl |ltt Ltt
tt
1) Thesesampleswere
dissolved
totallyby precondjtjoning
methodaccorcling
to belowflowcnaft.
I Ur tesl methodexctuded)
yang
2') Nameof thepersonwhomademeasuremedt:
Climbgreat
3) Nameofthe pe6onin chargeof measurement
TroyChang
SampleI\reasurement
Aciddigestion
by suitable
acid
dependedon diferent samole
material(as belowtable)
Micro,,€vedigestionwith
HNOs/HCUHF
Addappopriateamountof
digestion
reagent
Heatto appropriate
temperatureto extract
'1) AlkaliFusion
2) HCltodissolve
ICP.AES
Cool,filterdigestate
throughfilter
Add diphenyl-carbazide
for
SampleMaterial
colordevelopment
DigeslionAcid
Steel,copper,
aluminum,
solder
Aqua regia,HNO3,HCl,HF,H2O,
Glass
palladium,
Gold,platinum,
ce€mic
HNO3/HF
Aqua regia
Silver
HNO3
Plastic
HrSO4,HrOr,HNO3,HCt
Others
Anyacidtototaldigestion
comDa+
n yl , r i r l , r l l
irrrtili:ll f;. i,.i.lF
*iirrl\ I
Ths dmenl s 'ged by 6e c6mpa
subj.cl'o t tu $d conddo^sfor F
'j.r
measurethe absorbance
at 540 nm by UV-VIS
:i,l\li.
Aibn'onG dRn ro s6 rmid'onof rdrt
+onsbi|yslo6cen'ad6Edc!
!hdsrizo,qN4!F.vriieaoilf!1r,rjr.fr
rt's6(0r)2eer^r+s6(or)rsrr@wa*on
Test Report
No.: CE/2011/84956
Pager5 of 7
Date:2011t1?/0i
POLYFIL
AG
OBEMLLMENDSTMSSE
2OA,CH63OO
ZUG/ SWITZERLAND
nl|
l||l[]tn
PBB/PBDE
analytical FLOW CHART
1) Narneofthe personwnonECerEasuerent: RonEnWong
2) NarE of the personin chargeof rEasurernent:
TroyCharE
Firsttestingprocess---t
Odionalscreenprocess--,proc€ss - .>
Confiarnation
Screenamlysis
"""""'1""........
Sarpleextraction/
SoxhletdEthod
Concentrate/Dilute
Extractedsolution
Ft|ter
Analysis
by GC/MS
rsG)ras€drh s 16sr.6pod
annd b€,
.l:.
c d n p , i yi , : r ' rl r i r i . : - r i i i l ' l ; i l i J t i
i:i.!t
i
i!r,1!l l!l!l
Th5dogrud6gu3dbyb.compan,s!jedb{sG:iemlcofu1disolsedepndddvede,t9v,'3daoncq
{qed {o Tems aid coid{o.s ior E
3!d^gb'tyslo'9c€dandh's@
Ane oo r dr&^ ld s6 hrd'odo
drty
TestReport
No.: C92011/84956
Dale: 2Olltiuj,l
POLYFILAG
OBERALLMENDSTRASSE
2OA,CH63OO
ZUG/ SWITZERLANO
|l!t][mmfftmfl
Analyticalflow chartof halogencontent
1) Narneof thepersonwhonradenEasurenEntt
RitaChen
2) Nameof the personin chargeof nEasurenEnt:TroyChang
SanplepretreatnEnt/ Separation
Weighting
andputtings€rptein cetl
OrygenBombCombustion
/ AbsorDtion
Dildonto fixed\^clunE
Analysis
wasperforn€dby lC
comtsiy riji,tlr r1rr,. 3' i r1lliitlft r+ Lt,. ! jt .Lti!11_\
Th3dogm.nlE]s!.dbybecon0,n'9qedb€Gd.r.|condloBds.
3G) r6€d rh s €d €pod €iid
: r, 4r !rJll!j{-
Page: 6 of 7
B re
3p.nsb]itr€b{scl€d3ndlhsd@
_Lirr!?,ri:
i.ri:l1rj,t +8610r)r!e
Test Report
No.: CE/2011/84956
Paget7 ol7
D€l'e:2011112101
POLYFILAG
OBERALLMENDSTMSSE
2OA,CH€3OO
ZUG/ SWITZERLAND
ltN ltlt]fltttltl
* Thetestedaample/ part is markod
by an anow it ifs shownon the Dhoto.,
'* Endof Report
"
cohF0 'ir ! i !!r, rt,{' I rr'ri,lr.r!"t;
Ths dddmsl 6 'sd h, 6e c.np'
ior sbdonc rom31dodneib abj
1, . 1,3 rii+r-\ I
p3(s) t3d.d nEbd
rspd€ntu1b3
1. . rr, tr,Jrrl(.
r0 rh. rn'brd dr iab't,
r:-Irir
+:Iri14,.:i+s6loarrerD r+s6oareerr
pws5@
Test Report
Applicant:
Number : TWNC00249179
Littelfuse Philippines Inc.
LIMA Technology Center, Lipa City,
Malvar, Batangas
Date
: Mar 28, 2012
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: Silver plated Wire
Part Number
: DRAGxxx
Date Sample Received
: Mar 22, 2012
Date Test Started
: Mar 22, 2012
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
This report shall not be reproduced
except in full, without the written
approval of the laboratory.
Page 1 of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00249179
Test Conducted
(Ⅰ) Test Result Summary :
Test Item
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content (mg/kg with 50cm2)
Result (ppm)
Submitted Samples
ND
ND
ND
Negative (< 0.02)
Remarks: ppm = Parts per million based on weight of tested sample = mg/kg
ND = Not detected
<
= Less than
mg/kg with 50cm2 = milligram per kilogram with 50 square centimetre
Negative = A negative test result indicated positive observation
was not found at the time of Test.
Responsibility of Chemist : Irene Chiou / Kevin Liu / Cathy Chen
Date Sample Received
Test Period
: Mar 22, 2012
: Mar 22, 2012 To Mar 27, 2012
(Ⅱ) RoHS Requirement:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for
homogeneous material.
Page 2 of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00249179
Test Conducted
(Ⅲ) Test Method:
Test Item
Cadmium (Cd)
content
Lead (Pb) content
Mercury (Hg)
content
Chromium VI (Cr6+)
content
Test Method
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 7, by microwave
digestion until the tested samples are
totally dissolved and determined by
ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in annex B, by boiling water
extraction and determined by UV-Vis
Spectrophotometer.
Reporting Limit
2 ppm
2 ppm
2 ppm
0.02
mg/kg with 50cm2
Remark: Reporting limit = Quantitation limit of analyte in sample
Page 3 of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00249179
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Cd/Pb/Hg/Chromium (VI)
Reference Standard:IEC 62321 edition 1.0:2008
Sampling/grinding or cutting
Cd/Pb/Hg
Cr
Polymers /
Electronics
Metal
For different
material, digest
the sample with
*1
appropriate acid
By spot test
Negative
Confirm the tested
samples are
totally dissolved
Make up with
deionized water
6+
*2
Weigh sample
and add
alkaline
solution
Get 50cm2 sample
Definite temp.
extraction
Boiling water
extraction
Cool and filter
the extract
Analyzed by ICP-OES
Make up with deionized
water and add diphenylcarbazide solution
Analyzed by UV-VIS
Remarks:
*1: List Of Appropriate Acid:
Material
Polymers
Metals
Electronics
Acid Added For Digestion
HNO3,HCl,HF,H2O2,H3BO3
HNO3,HCl,HF
HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected.
End of Report
Page 4 of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00249179
Test Conducted
Photo
Page 5 of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401