EN

Photoelectric sensors
OADR 20I6565/S14F
Distance sensors
dimension drawing
7,5
4,6
4
51
39,5
20,25
65
57
LED
9
* 16
M 12 x1
16,4
* emitter axis
general data
photo
measuring distance Sd
30 ... 130 mm
special type
Washdown design
adjustment
external
Teach-in range min.
> 3 mm
power on indication
LED green
soiled lens indicator
LED red
resolution
0,005 ... 0,06 mm
linearity error
± 0,015 ... ± 0,2 mm
light source
pulsed red laser diode
wave length
650 nm
laser class
2
beam type
line
beam width
2 ... 1 mm
beam height
3 ... 5 mm
temperature drift
< 0,03 % Sde/K
approvals/certificates
Ecolab
connection diagram
BN (2)
+Vs
WH (1)
electrical data
response time / release time
Analog
< 0,9 ms
voltage supply range +Vs
12 ... 28 VDC
current consumption max. (no load)
100 mA
output circuit
analog
output signal
4 ... 20 mA / 0 ... 10 VDC
load resistance (analog I)
< (+Vs - 6 V) / 0,02 A
load resistance (analog U)
> 100 kOhm
output current
< 100 mA
alarm output
PNP
short circuit protection
yes
reverse polarity protection
yes, Vs to GND
OADR 20I6565/S14F
n.c.
GN (3)
PNP
analog U
GY (5)
alarm
YE (4)
ext. teach
RD (8)
BU (7)
www.baumer.com
analog I
PK (6)
sync. in
Z
Z
Z
0V
alignment of the laser line
23/4/2015
Photoelectric sensors
OADR 20I6565/S14F
Distance sensors
mechanical data
laser warning
width / diameter
20,3 mm
height / length
65 mm
depth
51 mm
type
rectangular
housing material
stainless steel 1.4404 (V4A)
front (optics)
PMMA
connection types
connector M12 8 pin
LASER RADIATION
DO NOT STARE INTO BEAM
Wavelength: 620...680nm
Max. av. Output: < 1mW
IEC 60825-1, Ed. 2, 2007
CLASS 2 LASER PRODUCT
Complies with 21 CFR 1040.10 and 1040.11 except for deviations
pursuant to laser notice No. 50, dated June 24, 2007
ambient conditions
ambient light immunity
< 40 kLux
operating temperature
0 ... +50 °C
protection class
IP 69K & proTect+
Sensor FDA compliant and Ecolab
approved
sensitivity adjustable: via Teach-in wire
input
OADR 20I6565/S14F
www.baumer.com
23/4/2015