Photoelectric sensors OADR 20I6565/S14F Distance sensors dimension drawing 7,5 4,6 4 51 39,5 20,25 65 57 LED 9 * 16 M 12 x1 16,4 * emitter axis general data photo measuring distance Sd 30 ... 130 mm special type Washdown design adjustment external Teach-in range min. > 3 mm power on indication LED green soiled lens indicator LED red resolution 0,005 ... 0,06 mm linearity error ± 0,015 ... ± 0,2 mm light source pulsed red laser diode wave length 650 nm laser class 2 beam type line beam width 2 ... 1 mm beam height 3 ... 5 mm temperature drift < 0,03 % Sde/K approvals/certificates Ecolab connection diagram BN (2) +Vs WH (1) electrical data response time / release time Analog < 0,9 ms voltage supply range +Vs 12 ... 28 VDC current consumption max. (no load) 100 mA output circuit analog output signal 4 ... 20 mA / 0 ... 10 VDC load resistance (analog I) < (+Vs - 6 V) / 0,02 A load resistance (analog U) > 100 kOhm output current < 100 mA alarm output PNP short circuit protection yes reverse polarity protection yes, Vs to GND OADR 20I6565/S14F n.c. GN (3) PNP analog U GY (5) alarm YE (4) ext. teach RD (8) BU (7) www.baumer.com analog I PK (6) sync. in Z Z Z 0V alignment of the laser line 23/4/2015 Photoelectric sensors OADR 20I6565/S14F Distance sensors mechanical data laser warning width / diameter 20,3 mm height / length 65 mm depth 51 mm type rectangular housing material stainless steel 1.4404 (V4A) front (optics) PMMA connection types connector M12 8 pin LASER RADIATION DO NOT STARE INTO BEAM Wavelength: 620...680nm Max. av. Output: < 1mW IEC 60825-1, Ed. 2, 2007 CLASS 2 LASER PRODUCT Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to laser notice No. 50, dated June 24, 2007 ambient conditions ambient light immunity < 40 kLux operating temperature 0 ... +50 °C protection class IP 69K & proTect+ Sensor FDA compliant and Ecolab approved sensitivity adjustable: via Teach-in wire input OADR 20I6565/S14F www.baumer.com 23/4/2015