ICPTest_374 pdf

ICP Test Report Certification Packet
Company name :
Littelfuse, Inc.
Product Series:
TR5 Subminiature Fuse Series
Product #:
374xxxxxxx series
Issue Date:
April 18, 2012
It is hereby certified by Littelfuse, Inc. that there is neither RoHS (EU Directive
2002/95/EC)-restricted substance nor such use, for materials to be used for unit parts, for
packing/packaging materials, and for additives and the like in the manufacturing processes.
In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used
for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing
processes, are all composed of the following components.
Issued by:
<Global EHS Engineer>
(1) Parts, sub-materials and unit parts
This document covers the TR5 Subminiature Fuse Series RoHS-Compliant series products
manufactured by Littelfuse, Inc.
< Raw Materials Used
Please see Table 1
(2) The ICP data on all measurable substances
Please see appropriate pages as identifed in Table 1
Remarks:.
Form 585-047 Rev. A
1
2/21/06
Table 1: List of Raw Materials covered by this report
Total Parts
1
2
3
4
5
6
Raw Material Part Number
DRAGXXX
LOZZ194 (692213)
910-016
867-003
009116
GLZZXXX
Raw Material Description
Melting Wire
Wire-Solder
Plastic Cap
Socket with Pin
Ceramic Paper
Yarn
2
Page(s)
3-12
13-17
18-26
27-33
34-39
40-45
,fl.d,+E+
TestReport
trTxlt*.5G
nown
ForOue5ll
PleaseCo
ithscs
f i , S ( N " . ) , c E / 2 0 1 2 / ] 0 8 3 5 E 4 ( D a t e ) : 2 0 r 2 l 0 1 / 1 1 F & ( P a 8 e ): r o f r o
ELSCHUrcMELEKTROSCHUTZI{OMPONENTENBAU
GIIBH
CEI'ERBESTR,ASSE
87, D-98669 \EIISDORF, GE&UA\Y
ideltified
Validit
68P 't&, -R& *,P +*&lf*P
hylon behatf of rle client
iiSZ,f*(s.'pl" D€s.ripr ion)
if gd&(style/I r€b N".)
4 , & . E ( c o u n t i y" f o r i s i n )
{t4 A S (s.'!1" Rec€ivingDate)
,tlHS&l(Tesrihc P€.i od)
ji,t,+ jR(rest Resrlts )
'
|l]
*AnT
(The folloeins
saDples ra./rcre
srbeittcd
t|| fl m
and
as):
SILIER
PIATED & PURE SILVM
$'IRES
',tr+*sR
(PLEASEREFERTo PAGEs)
(GERI4A\"Y)
{EE
2012/0t/04
2 0 1 2 / 0 t / 0 4 ' f o2 a t 2 /a t / t l
5 + X .F - F { P r e a , e r e f p - r o r e x r ! a s c ! r
(Alw4?\
C$Fdft.|nd
chrnLd lrbor.tlry - Trlpd
?
r'-;.!liiri
i
.:
i
).:!tli
p3G)6rad rb s rad Gpon€n'orF
ir. r.r rl!tul.
McmbForfie !69 Gouo6c! Sr,.r
,fla,+E+
TestReport
! t 4 5 ( N o .) : c E / 2 0 I 2 l l o d J s
E q ( D a r " ) : 2 0 1 20 I / l l
E*{pase) ,2 oi l0
ELSCHUKOM
ELU(TRqSCHUTZXOMPONENTENMU
GVBH
GENERBESTI{ASSE
87, D-98669'IIEIISDORF,CE!.T{Ar\Y
It**(T.st
]||lt[ttl||||fiml|!
R e 6 u lt s )
jrl:i *r'.i (PARTNAME)No.l :
ie;qma&ein&
(6{t,r)
(Jt6t ) (MTXED
ALLmLoRtltErArNrm
( INCLUDINGTIiE PLATINC LA\'ER) (6 TYPES))
r|iiit E
ttt.ttrl
Etl{N
*ittri
+lt
(Urit)
,fr / cadniun (cd)
(rDL)
+arEc 623zLt2oo8r;i, 4&,S*{
6€*.F+&4t*.*d,h;Fl.
/ q'ith
refe.ence
perforfted
S
/ Lead (Pb)
to IFC 62327t 2008 anl
6y ICP-AFS.
++IEc 6232rt2008ti1, rr t$A*t
+t*fr+**i*,;*d&;il.
/ {i ih
.eference to IEC 62321: 2008 and
by ICP-,ES.
terforaed
*- / vercury (Hs)
: 2008t&,'r€E*4
++ lEx.62321
+€ {/F + **t rt ;* d,*birl. / $i r1'
reference to IEC 62321: ?008 and
perforned by tCP-r{XS,
,i.flJ'
/ Heaav,lent chroni!n c.(vI)
++ \F: 62321.2OO8li*, t)a.,fr
*+
/ with fefe.€n€e ro IEc
RliAtll.
6 2 3 2 1 . 2 i A B a n d p e r f o r m e db y
B o iI i n s s a t e r e x t . a c t i o n M € t h o d . #
}fr.+B**
sulfonates
/ Perrruo.oocrane
nglka
(PF!S-Acid. Uetal salt
t+us
EPA3540C:1996tii, 'lil
IO
iE,9*f1[-r*&}f,4
an+,t,4*69'
/ t r i t h r e f e r e n c e t o u s E P A3 5 4 0 c
1 9 9 6n € t h o d f o r P F o SC o . l e . l .
Analysis was perlorned by tClMS.
an+6.(J+) / PFoA(cAsNo.: 3356?
r)
++US EPA3540c:l996tt!,
,Xtl
&Eif 1{r*{,*fl an+d(n) }f
/ w i t h r e f e t e n c € t o U S E P A3 5 4 0 C
1 9 9 6e e t h o d f o r P F O AC o n t e n t .
Analysis was perfofned by rc/MS.
i j :i :r l , ]. r : . a i i . ; ; r t i ]
c o n o a .t y r r , : 1 r 1 , ri!' _, r r l - J n
iy $qd rob cene6cdidroc d s
onlysndwibinlh.imlsoic€nls'ns
pelsr reded rhE bd rcpod Enid be
1, . r, rjr,!*.
l0
s*
(Resql t)
No,1
rfla+E+
ft4(No.) : cE/20I2lr0835
Test Report
E J q ( D a r :e2)0 t 2 l 0 t
E * . t e , B " ,/ 3 . r
ELSCHUKOM
ELEKTROSCHUTZKONPONENTENBAU
CMBq
GMERBESTRASSE
87, D-98669 !'EIISDORF, GERMAIr\
d{t
E
lll
+4o
,{fi,t*
( U n it )
( R e s u1 t )
(IDL)
No.l
/ uonobronobiphenyt
:;Ad*
qA#tri
/ Dib.onobipltenyl
/ T r i b r o n o b ip h e n y l
/ T e t r a b r 6 n o bLo h e n v l
I*#Xi
/ P e n t a b r o n o br o h e n ! I
/ Hexabronobiphenyl
?!4$it
+iASf
/ H e p r a b . o n o bpi h e . y 1
^itrfi A / o.rabronobipheDyl
/ Nonabromobipheryt
4)qS*
/ D e c a b r o n o bpih e n y t
+;ASf
*trEc
/ suo of PBDES
t*AS.t&t"
-;ASf!{
/ M o n o b r o n o dD
i hehvl ether
=-r[#*e
:;A#+a{
/ D i b r o n o d ip h e n y l e t h e r
/ ' l r i b r o d o d i p } e n v l er h e .
B,*SiFa*
/ Tet ra6.onodi phe.vl erher
i;*Sxad
'r*S*a*
/ P e . r a b r o m o dDi h € " v l e t h e r
/ H e a a b r o n o dpih e r v t e r h e r
-k;A#Xa{
/ H e p t a b r o m o d iD h € n v l e t h e r
,\;*SXa{
/ o c r a b r o n o dD
i he.vl ether
,L;i#*e
i henvl etler
i N o n a b r o m o dD
+&#ii4
/ D € c a b r o n o d i D h e n velt h e r
623211
zoo$iiF, ,tfu|aE
+8dlf :*d,&jrl. / $ith rererence
ro IEC 62321:?008 and perforned
by rc/MS.
5
5
5
5
5
5
5
5
5
5
5
5
5
5
a* / s"l.s."
(fr.) / Halogen-Floo.ine(F) (c{s
6*
No.: 14?6?_94-8)
(5.) / Haloeen-chlo.ine (cl) (cAs
6*
! o . : 2 2 5 3 71- 5 - r )
& * ( * ) / H a l o r e n - B r o n i n e( B r ) ( c A S
l{o.: 10097-32-2)
50
ng/18
vx&+8fr
ltBs vt r4s82:2007,
50
/ sirh reference to Bs EN
{r}*t.
I 4 5 8 2 r 2 0 0 7A. n a l y si s v a s
50
(I) (cAS
6fr (dU / Halocen-lodine
No.: 14362-44-8)
conFiv;"
r 1 llu.,[r'r,
l: i/irr.r I i.tl
lt!,lr'i
oyglbredbb6ai.'alcondloisds
50
hrr.(s) rssbd rh s resr €pon ennd
lLr Lt[]!.
iq
3pdJb't}6lobc€da^dhsdocu
b
r**
,illt,rl
EIE{I
/ su! of PBtss
t*t**'ts
:14#*
:i*#f'
(Iethod)
ro
l ]tl|
]t
,F{a+E+
ff6(No.)
Test Report
: CE/2012l10835
aBlJzr.)
. 20L2/ot/71 Ftk(pare) : 1 of r0
EI-SCHIrXOI1I
ELEKTROSCHUTZ(oVPO|iENTU\]BAU
GttBH
GEI/ERBE.STT.ASSE
87, D,98669 VEITSDORF.GERVIIY
[]tl||t][]tI|
fiii(N.t.):
l . m g l k g: p p m ;0 . | w t %= l o o o p p n
2 _ n _ d . = N o r D e t e c t e d( * . t A r r )
3 - M D L: M e t l o d D e t e c t i o n L i r i i ( r l t l A ; { t s 1 8 1 6 )
4. '- = Not R"sulated (Sli,+&.6)
5 . r ' = Q u a t i t a t i v e a n a L y s i s( N o u n i t ) _ € , B r ) * f ( * + & )
6. #:
a . P o s i t i v e b e a ! s t l e p . e s e n c eo f C r V t o n t h e r € s t e d a r e a s
(po s i t i ve *,F rq,lit E q.tF jq r{ ,r{l rS)
b . N e g a t i v e n e a n s t h e a b s e n c eo f C i V I o n r h € r e s t e d a . e a s
( Nesat i ve i nr::tl*, E 4 t.tA ).14 'r1l1g )
T h e d e t e c t e dc o h c e n r r a t i o ni n b o i l ] n a - e a r € r - e x r r a c t i o sno l u t i o n i s € q u a l o r g r € a r e r t h a b 0 . 0 2
m A l k gw i t h
50 cn: tested ar.a". / li6;i{XA>0.02
nslka *iih 50 cm, (tested
z. tte.i,tlS{r.'Af
;F./.**isArxl:{,, *E+titi,sA,tt:ri}:+.Tftt 4 +1Erll+-ttlt aiAE.
(The sanples sas/were analyzed on behalf of the atfricant
! e s u l t s w a s / w e r eo n l y g i v e n a s r t e i n f o . n a t i t y v a l u e , )
PFos++*d,(R"f
Inf orlation)'
"'.o"€
(1) riitrrf rTfi.'|tsld.&n,r+r+4rrf,
as mixing sanpre in one resrine.
The above
!A+ 2oo6trzztEa (Di rect iae 2006/t2ztw)
d.Ee,Ed,rlE*tla+,i6d.n,+0.
005%.
(May not be placed on the market o. used as a sDbstance o. consrituent
€qual io or nigh€r than 0.005 % by nass.)
of prepararrons
(2rtit{ttX4n&*fi&}.ei+d."%d.6s{.*{r1+;1!i*€1+}aX*Jt+ApFosi.4t?J*fi}.e.t&r€t6€};l4pFosEE
,i.&+,i!d.i,ifo.r%,6*r&€d.4{tti.4rf. {,RprrsaAt*f + 6E*;Ad.Ji;Aruc/.,.
(Maynot be placed on ihe na.k€t in seni-linisned prodocts or articles, or pa.ts rhereof, if
ure
c o n c e n t . a t i o n o f P F O Si s e q u a t r o o r h i g h e . t h a n 0 . 1 % b y n a s s c a l c ! l a t e d s i t h r e f e r e n c e t o t l e n a s s o f
s t . u c t u r a l i y o . f r i c . o s t r u c r u r a l l y d i s r i n . r p a r r s t ! a i c o n t a i n P F o . so r , f o . r e x r i t e s o r o t h e . c o a r e d
naterials,
if thc anoun! of PFOSis equal to o. hiahcr than Ug/nr of thc coated nateriat.)
c o m p a ityr : ; r , r ; : i r l , , ; - f i t . r l J r . n i r r , . r , , t i i
Ltlttr
1i., r".l,r!/,)!
ont andub'n ihsh b orc en'3,ns
-.4ttr
- ! . ! , , : r r i r l l i - I. c i e o a F i
-:.r ;::rlnti,,;i+46iDr,ssr7
l
,rla#+
TestReport
ft,q(No.) : cE/20r2lr0835
E S ( D a t e ) : 2 0 1 2 1 0 1 / 1 1F * . ( p a s € ) : 5 o r l 0
EI-SCHIXOi,I
ELEKTRO€CHUIZKNTPONENTENMU
CVBH
GEIIERBESTInSSE
87, D 98669 IEIT,SDORF.GERILUY
tl&4!t(styl./I
[t[t
t.' N".)
(B-1) 101. 014
-silver
plated coFpe.{tre-Cu. Ag - - %
(B-2) 101. 0131. - - - - -pure silve. sire-Ag l()()()
( B - 3 ) 1 0 1 . 0 1 2 3 . 0- - - - s i l v e r
platcd purest nickct vire-Ni99.98%. AgI%
-silve.-copper alloy plated cotpe. clad vire-Elcon D,
(B-4) 10r,0182.0 - -silver
(B 5) 101.0120.0
p l a t e d c o n s t a n t a nw i i € - C u N i 4 4 , A A S %
( B - 6 ) 1 0 1 . 0 1 5 1 . 0- - - - c o p p e r - n i c k e t 4 4 a l l o y s v e r p l a r e d s i . e - c u N i 4 4 ,
c o D o a n tv l r I t ! . , r - N ' | , r " l : l , i l l l i
:. ! 1 1:;!1,1\
p sG)rssr€drh s€d Gpon€ind e
rlllrillrl.
!
ont 3nd*ii'n rh. hrs or c €nr s 'ns
ri.:l,;l-":Iq:j1
tl|
|||ll
,fl-d,#+
Test Report
f i { 5 ( N o . ) : C E l 2 0 1 2 l l o s 3 s E S ( D a r e ): 2 o t z l 0 r / t t F # ( p a s € ) :
ELSCHUI{OM
ELEKTROSCHUTZKOMPONENTENBAU
G\!BH
GEWERBESTRNSSE
8?, D 98669 WILSDoII, CERMA\Y
6
0 f l 0
[l|[]|l
r) ll?cr,-F $,EEn zI*1+ ' *.& aia*t+
. ( *1' j&d *tt *hrl. ) / Thes€samDtes
!,€€
d€sotuedrolrrryby p.e-condrumhgmethooaccodinglo betN nowchad. cP re€tmethodexcludeo
2) r.lri^l:
yang
$e ! / Naheotlneps6onwhomadenEsuremed:ctimbgreal
3) ir'13{I i ^ : tl4* / Nameof the pe6on in chargeormeasu€m€nlrTroychans
tr*. {rtt*s
/curing. p€galaton
iqr{.&,cf ! / sdde MeasuEmenl
&lf;F n l*'.g6tt{ f, 6 }xn!trai&it,tirt /LoeTt
4rt/!inlt n.i'la{&,aib /
4,;) /Acid dig€slion by suitabte acid dependedon
dtrerenlsahdemaledat{asbetowiable)
MiorcMve digestion with HNO3/HC|/HF
,"rl4rOf jit& jt.li,lilt +
C( / H€i to appropriate
1)
2)
f [*a{*4+*it{rtc
/ AlkaliF6ion
/HCltod$d€
/ rcP,aEs
f!911L / samdeMatedal
51eel,@pper,allnirum, solder
&ltgti
ta{*tt
;filt&AJlfi / DiqesL|onAcd
-t+, 4la{,!lt, nn*, el,,k /
Aa@ reoia. HNO' HCl. HF. H,O,
rra{,Inc / HNoJftF
A, J6,€, nit /
Gold,olalinum,
Dalladium,
ceramic
,i(f rf 7h-ir,g t.rLrlf,.' I
irl#B*i{Aftrcnm 6id
rti!€ /HNOr
&E / Plaslic
4?,*i&8tt$ / coot,
fherdigestate
lhrough
liher
*d, t{"*,
s!t, td / H,so. Ho,. HNorhcl
,! \'efi*1eti*l+
/ Anyacldlo lotaldig€Gtion
j i i r i r +
r i l , i ,
! . r 1 r . t p . l i , . 1 , i f i ' ! ! l .
rhcdddneiiAs€dbysgcompa^ys!b4d{ob6ai..a|condloi3ds
ab6o6anceat a/ronmby
UV-VIS
t]n]l
,F{a*R+
Test Report
iEIS(No.) : cE/2012l10835
E rr?(Dare) : 2012l01/11 F&(P,s")
ELSCHUKOMELEI$ROSCHUTZKOIIPONENTENB,qU
GMBH
CETERBESTRA.SSE87, D-98669 VEIISDORF, CER[{AI\'Y
t ttt*/t
rtt+4+f
l
*,aE / PBB/PBDE
anatyticat
FLOWCHART
a }l{,/\l
I a_i9*, / Nameoftheperson
whomademeasuremenl:
RomanWonq
r,$Ji( frt ^ : &+le / Nam€of thepersonIn chargeof measurement
TrcyCha;g
n^ ld,ElF / Firstlestry proce.s------------f
....,---.
prccess
€*,E&*€F / OptionalscE€n
-. -,t
*{.€,S / Confimation
orccess
:l
Scre€n
analysis
/ ,, rfi+rt
I
I
sample
erlraclion
*s+*/
Soxhlet
melhod6i,+tx;*
Concentrale/Dilute
Enractedsoluiion
+tri{ rira/ifi#
Filter/ +S.i{'E.d
Analysis
byGC/MS
/ fr"ian&f ie*,+&
*irl+
c o m D a n +! " , I
rirr,,: i;
r. lJ: ?.lria 1.:-!i
-j!,AlrI
3u!,0db'.ms,idcoidsdislolE
pslsl bdad h€rad cpod€nnorb3
i.,.-l:r311.!
|
|
t
l||tI
l
rF{-d,+E+
Test Report
f t 1 4 ( N o . ) , C E / 2 0 r 2 l 1 0 8 3 5E S ( D a r . ) , 2 o l 2 l l ] t / t t
F&{prse)
EI.SCHUI(OM
ELEI{TROSCHUTZ(OMA)NENTENB,{U
GVBIi
GE9ERBESTTASSE
87, D 98669 \,'EIT-SDoRF.GEf,Vl}IY
it+&fiAn
I
I
Il]tIltt][||||[|!
/ Analyticalflowchartof halogencontent
jtli{,l.F : gi',g* / Naneof thepersonwhomademe€surement:
RitaChen
jrl:i,A ll, : #,*e / Nameof thepersonin cbargeof measurement:
TroyChang
*+E &t&.'sl'I
Analysis
wE6perfomedby lC
.Iir
Th s ddfuh.il
s '$u€d bl ft
np61s) rssbd fu bn cpod €nnor b
i.'.iiri:llr
it
Li
ii'!r]-l
i -1"j! :
pa
c om
3 l b j e d b ] e m s a i d c o i d l o n s f o r E A t a ^ l o n 6 d d n l o f t ] m l a t o n d s b l t y
.;.: r.r- i.1-]ii1
r,r+ s6iorre
rD r+ s6 Lo?lrrenr
wwslon
ilts,#+
TestReport
it4(No. ) : cE/2012l10835 AS(Dare) : 201210r/tr
F*.(pase) : 9 of lo
E-SCHUKOM
EI-E(TROSCHUTZKO]\IIONENTEN&{U
GMBH
GEFERBESTRASSE
87, D-98669 VEIISDORF, CERMA]\ry
tI|fll|t][taf,
*Ji+n+fin€n /
Analyticalflow chartofSoxhtetextraction(LC/MS)procedure
r
r
i A/-F : ij!9*y / Nameofthe personwhomademeesuementRcmanWong
t4j:{, q i,\ : tF'.*4 / Nameof the personin chargeof measurement:
TroyChang
( rd8,{ a : Afi.+n*.n/Afi.+rt(*)
, **.:4i{bA4,
Test ltems: PFOS/PFOA. Benzotriazole)
*{*
cmpanyr:i r , tr 'ri_ll i ,r'"'ll:l ill+
r. r i rtirril: .
/ Datia
p3G)r8sbd
rh s rsd,epon
€inore
-. '.- it!,1 .
pdisb ,9 a b b cr ed and ih s dotum
/
l
trl'd,#+
TestReport
fi6(N". ) , c-E/2072/10a35
Es(Date) : 2tr2/ar/r1
E*@aEe) : r0 of t0
ELSCHTJKOM
ELENROSCHU'\ZKOMPONENTENBAU
GMBH
GEISRBESTR.ASSE
8?, D.98669 WII-SDOTF,GERVA}Y
trlt[tl
+ ffifi tr'6*t*i
' Fl* ftfrfl*lt,rlz{tsi
(The tested sanple / part is narked bt an arror if
ir's
1083s
10835
** lE+344.(E"d of Report) ++
i:. j:r.i | ,.tll
itt: I
c d h p , i in r . i ' , r , " r i l ' i , ,
rhsdoarudE 3s!sdbyhe.omp,^yeqedb G6erydcodromor s
+ *ri.*irr !r. i r,.
l6en,a r,p.
'
..
. !,r:L!.
${i'
t
shorn on rhe photo.)
fl|||trr
Number : TWNC00232330
Test Report
Applicant:
Littelfuse Philippines Inc.
LIMA Technology Center, Lipa City,
Malvar, Batangas
Date
: Nov 18, 2011
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: Solder
Part Number
: 692213
Date Sample Received
: Nov 11, 2011
Date Test Started
: Nov 14, 2011
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
This report shall not be reproduced
except in full, without the written
approval of the laboratory.
Page 1 of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00232330
Test Conducted
(Ⅰ) Test Result Summary :
Test Item
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content (mg/kg with 50cm2)
Result (ppm)
Silvery Metal
ND
92
ND
Negative (< 0.02)
Remarks: ppm = Parts per million based on weight of tested sample = mg/kg
ND = Not detected
<
= Less than
mg/kg with 50cm2 = milligram per kilogram with 50 square centimetre
Negative = A negative test result indicated positive observation
was not found at the time of Test.
Responsibility of Chemist : Irene Chiou / Kevin Liu / Cathy Chen
Date Sample Received
Test Period
: Nov 11, 2011
: Nov 14, 2011 To Nov 17, 2011
(Ⅱ) RoHS Requirement:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for
homogeneous material.
Page 2 of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00232330
Test Conducted
(Ⅲ) Test Method:
Test Item
Cadmium (Cd)
content
Lead (Pb) content
Mercury (Hg)
content
Chromium VI (Cr6+)
content
Test Method
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 7, by microwave
digestion until the tested samples are
totally dissolved and determined by
ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in annex B, by boiling water
extraction and determined by UV-Vis
spectrophotometer.
Reporting Limit
2 ppm
2 ppm
2 ppm
0.02
mg/kg with 50cm2
Remark: Reporting limit = Quantitation limit of analyte in sample
Page 3 of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00232330
Test Conducted
(Ⅳ) Measurement Flowchart:
Test for Cd/Pb/Hg/Chromium (VI)
Reference Standard:IEC 62321 edition 1.0:2008
Sample preparation
Take sample and immerse into Aqua Regia, start to strip plating layer
Stop the stripping procedure upon color change completely
Take the Aqua solution as plating component and stripped body as substrate component
Cd/Pb/Hg
Cr
Polymers /
electronics
Metal
For different
material, digest
the sample with
*1
appropriate acid
By spot test
Negative
Confirm the tested
samples are
totally dissolved
Make up with
deionized water
6+
*2
Weigh sample
and add
alkaline
solution
Get 50cm2 sample
Definite temp.
extraction
By boiling water
extraction
Cool and filter
the extract
Analyzed by ICP-OES
Make up with deionized water and add
diphenyl-carbazide solution
Remarks:
*1: List of Appropriate Acid:
Material
Polymers
Metals
Electronics
Analyzed by UV-VIS
Acid Added for Digestion
HNO3,HCl,HF,H2O2,H3BO3
HNO3,HCl,HF
HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected.
End of Report
Page 4 of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00232330
Test Conducted
Photo
Page 5 of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Test Report
Applicant:
Number : TWNC00232331
Littelfuse Philippines Inc.
LIMA Technology Center, Lipa City,
Malvar, Batangas
Date
: Nov 18, 2011
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: TE Caps (same with 910-016 TR Caps)
Part Number
: 910-017
Date Sample Received
: Nov 11, 2011
Date Test Started
: Nov 14, 2011
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
This report shall not be reproduced
except in full, without the written
approval of the laboratory.
Page 1 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00232331
Test Conducted
(Ⅰ) Test Result Summary :
Test Item
Result (ppm)
Brown Plastic
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content
Polybrominated Biphenyls (PBBs)
Monobrominated Biphenyls (MonoBB)
Dibrominated Biphenyls (DiBB)
Tribrominated Biphenyls (TriBB)
Tetrabrominated Biphenyls (TetraBB)
Pentabrominated Biphenyls (PentaBB)
Hexabrominated Biphenyls (HexaBB)
Heptabrominated Biphenyls (HeptaBB)
Octabrominated Biphenyls (OctaBB)
Nonabrominated Biphenyls (NonaBB)
Decabrominated Biphenyl (DecaBB)
Polybrominated Diphenyl Ethers (PBDEs)
Monobrominated Diphenyl Ethers (MonoBDE)
Dibrominated Diphenyl Ethers (DiBDE)
Tribrominated Diphenyl Ethers (TriBDE)
Tetrabrominated Diphenyl Ethers (TetraBDE)
Pentabrominated Diphenyl Ethers (PentaBDE)
Hexabrominated Diphenyl Ethers (HexaBDE)
Heptabrominated Diphenyl Ethers (HeptaBDE)
Octabrominated Diphenyl Ethers (OctaBDE)
Nonabrominated Diphenyl Ethers (NonaBDE)
Decabrominated Diphenyl Ether (DecaBDE)
Halogen Content
Fluorine (F)
Chlorine (Cl)
Bromine (Br)
Iodine (I)
Phthalates
Di(2-ethylhexyl) Phthalate (DEHP)
Dibutyl Phthalate (DBP)
Benzyl Butyl Phthalate (BBP)
Others
Hexabromocyclododecane (HBCDD)
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
Remarks: ppm = Parts per million based on weight of tested sample = mg/kg
ND = Not detected
Responsibility of Chemist : Irene Chiou / Kevin Liu / Cathy Chen
Date Sample Received
Test Period
: Nov 11, 2011
: Nov 14, 2011 To Nov 16, 2011
Page 2 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Test Conducted
(Ⅱ) RoHS Requirement:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Polybrominated Biphenyls (PBBs)
Polybrominated Diphenyl Ehters (PBDEs)
Number : TWNC00232331
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for
homogeneous material.
(Ⅲ) Test Method:
Test Item
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+)
content
Test Method
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the
tested samples are totally
dissolved and determined by ICPOES.
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the
tested samples are totally
dissolved and determined by ICPOES.
With reference to IEC 62321 edition
1.0:2008 in clause 7, by microwave
digestion until the tested samples
are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in annex C, by alkaline
digestion and determined by UV-Vis
spectrophotometer.
Reporting Limit
2 ppm
2 ppm
2 ppm
1 ppm
Page 3 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00232331
Test Conducted
(Ⅲ) Test Method:
Test Item
Test Method
Reporting Limit
With reference to IEC 62321 edition
1.0:2008 in annex A, by solvent
Polybrominated
5 ppm
extraction and determined by GC-MSD
Biphenyls (PBBs)
and further HPLC confirmation when
necessary.
With reference to IEC 62321 edition
Polybrominated
1.0:2008 in annex A, by solvent
5 ppm
Diphenyl Ethers
extraction and determined by GC-MSD
and further HPLC confirmation when
(PBDEs)
necessary.
With reference to EN 14582:2007 by
Halogen Content
50 ppm
calorimetric bomb with oxygen and
determined by ion chromatography
With reference to EN 14372: 2004, by
Phthalates
solvent extraction and determined by
50 ppm
GC-MSD
With reference to USEPA 3540C, by
Hexabromocyclododecane
10 ppm
solvent extraction and determined by
(HBCDD)
GC-MSD
Remark: Reporting limit = Quantitation limit of analyte in sample
Page 4 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00232331
Test Conducted
(Ⅳ) Measurement Flowchart:
Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents
Reference Standard: IEC 62321 edition 1.0:2008
Sample preparation
For non-metal part
For metal part
Take sample and immerse into Aqua Regia, start to strip plating layer
Stop the stripping procedure upon color change completely
Take the Aqua solution as plating component and stripped body as substrate component
Cd/Pb/Hg
Cr
Confirm the tested
samples are
totally dissolved
Make up with
deionized water
PBBs/PBDEs
Polymers /
electronics
Metal
For different
material, digest
the sample with
*1
appropriate acid
6+
Weigh sample and
add organic solvent
By spot test
Negative
Get 50cm2 sample
By boiling water
extraction
*2
Weigh sample
and add
alkaline
solution
By Soxhlet
extraction or
Solvent extraction
Definite temp.
extraction
Cool and filter
the extract
Analyzed by ICP-OES
Concentrate the
extract and make up
with organic
solvent
Analyzed by GC-MSD
Make up with deionized
water and add diphenylcarbazide solution
Remarks:
*1: List of Appropriate Acid:
Material
Polymers
Metals
Electronics
Analyzed by UV-VIS
Acid Added for Digestion
HNO3,HCl,HF,H2O2,H3BO3
HNO3,HCl,HF
HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected.
Page 5 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00232331
Test Conducted
(Ⅳ) Measurement Flowchart:
Test for Halogen Content
Reference Standard:EN 14582
Sampling/grinding or
cutting
Add absorbent in a
combustion flask &
place weighed sample in
equipment
Fill oxygen into
calorimetric bomb
Ignite then leave the
flask at room
temperature
Transfer the absorbent
into a volumetric flask
Make up with deionized
water
Analyzed by ion
chromatography
Page 6 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00232331
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Phthalates Contents
Reference Method: EN 14372: 2004
Sampling/grinding or
cutting
Weigh sample and add
organic solvent
By solvent extraction
Concentrate the extract
and make up with
organic solvent
Analyzed by GC-MSD
Page 7 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00232331
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Hexabromocyclododecane (HBCDD)
Reference Standard:USEPA 3540C
Sampling/grinding or cutting
Weigh sample and add organic
solvent
By soxhlet extraction
Concentrate the extract and
make up with organic solvent
Analyzed by GC-MSD
End of Report
Page 8 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00232331
Test Conducted
Photo
Page 9 of 9
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Test Report
Applicant:
Number : TWNC00202737S1
Littelfuse, Philippines Inc.
LIMA Technology Center, Lipa City,
Malvar, Batangas
Date
: May 26, 2011
This is to supersede
report NO. TWNC00202737
dated May 25, 2011
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: TR Socket with pin
Part Number
: 867-003
Date Sample Received
: May 20, 2011
Date Test Started
: May 20, 2011
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
This report shall not be reproduced
except in full, without the written
approval of the laboratory.
Page 1 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00202737S1
Test Conducted
(Ⅰ) Test Result Summary :
Test Item
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content
Chromium VI (Cr6+) content (mg/kg with 50cm2)
Polybrominated Biphenyls (PBBs)
Monobrominated Biphenyls (MonoBB)
Dibrominated Biphenyls (DiBB)
Tribrominated Biphenyls (TriBB)
Tetrabrominated Biphenyls (TetraBB)
Pentabrominated Biphenyls (PentaBB)
Hexabrominated Biphenyls (HexaBB)
Heptabrominated Biphenyls (HeptaBB)
Octabrominated Biphenyls (OctaBB)
Nonabrominated Biphenyls (NonaBB)
Decabrominated Biphenyl (DecaBB)
Polybrominated Diphenyl Ethers (PBDEs)
Monobrominated Diphenyl Ethers (MonoBDE)
Dibrominated Diphenyl Ethers (DiBDE)
Tribrominated Diphenyl Ethers (TriBDE)
Tetrabrominated Diphenyl Ethers (TetraBDE)
Pentabrominated Diphenyl Ethers (PentaBDE)
Hexabrominated Diphenyl Ethers (HexaBDE)
Heptabrominated Diphenyl Ethers (HeptaBDE)
Octabrominated Diphenyl Ethers (OctaBDE)
Nonabrominated Diphenyl Ethers (NonaBDE)
Decabrominated Diphenyl Ether (DecaBDE)
Result (ppm)
(1)
(2)
(3)
ND
ND
ND
ND
--
ND
ND
ND
ND
ND
ND
--Negative Negative
(< 0.02) (< 0.02)
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
-----------
-----------
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
-----------
-----------
Page 2 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00202737S1
Test Conducted
(Ⅰ) Test Result Summary :
Test Item
Halogen Content
Fluorine (F)
Chlorine (Cl)
Bromine (Br)
Iodine (I)
Result (ppm)
(1)
(2)
(3)
ND
ND
ND
ND
-----
-----
Remarks: ppm = Parts per million based on weight of tested sample = mg/kg
ND = Not detected
<
= Less than
mg/kg with 50cm2 = milligram per kilogram with 50 square centimetre
Negative = A negative test result indicated positive observation
was not found at the time of Test.
Tested Components
(1) Black Body Part
(2) Silvery Plating On Metal
(3) Silvery Metal Substrate
Responsibility Of Chemist : Irene Chiou / Kevin Liu / Cathy Chen
Date Sample Received
Test Period
: May 20, 2011
: May 20, 2011 To May 24, 2011
(Ⅱ) RoHS Requirement:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Polybrominated Biphenyls (PBBs)
Polybrominated Diphenyl Ehters (PBDEs)
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for
homogeneous material.
Page 3 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00202737S1
Test Conducted
(Ⅲ) Test Method:
Test Item
Cadmium (Cd)
content
Lead (Pb) content
Mercury (Hg)
content
Chromium VI (Cr6+)
content
Chromium VI (Cr6+)
content
Polybrominated
Biphenyls (PBBs)
Polybrominated
Diphenyl Ethers
(PBDEs)
Halogen Content
Test Method
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 7, by microwave
digestion until the tested samples are
totally dissolved and determined by
ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in annex C, by alkaline
digestion and determined by UV-Vis
spectrophotometer.
With reference to IEC 62321 edition
1.0:2008 in annex B, by boiling water
extraction and determined by UV-Vis
spectrophotometer.
With reference to IEC 62321 edition
1.0:2008 in annex A, by solvent
extraction and determined by GC-MSD
and further HPLC confirmation when
necessary.
With reference to IEC 62321 edition
1.0:2008 in annex A, by solvent
extraction and determined by GC-MSD
and further HPLC confirmation when
necessary.
With reference to EN 14582:2007 by
calorimetric bomb with oxygen and
determined by ion chromatography
Reporting Limit
2 ppm
2 ppm
2 ppm
1 ppm
0.02
mg/kg with 50cm2
5 ppm
5 ppm
50 ppm
Remark: Reporting limit = Quantitation limit of analyte in sample
Page 4 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00202737S1
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents
Reference Standard: IEC 62321 edition 1.0:2008
Sample preparation
For non-metal part
For metal part
Take sample and immerse into Aqua Regia, start to strip plating layer
Stop the stripping procedure upon color change completely
Take the Aqua solution as plating component and stripped body as substrate component
Cd/Pb/Hg
Cr
Weigh sample and
add organic solvent
By spot test
Negative
Confirm the tested
samples are
totally dissolved
Make up with
deionized water
PBBs/PBDEs
Polymers /
electronics
Metal
For different
material, digest
the sample with
*1
appropriate acid
6+
Get 50cm2 sample
By boiling water
extraction
*2
Weigh sample
and add
alkaline
solution
By Soxhlet
extraction or
Solvent extraction
Definite temp.
extraction
Cool and filter
the extract
Analyzed by ICP-OES
Concentrate the
extract and make up
with organic
solvent
Analyzed by GC-MSD
Make up with deionized
water and add diphenylcarbazide solution
Remarks:
*1: List Of Appropriate Acid:
Material
Polymers
Metals
Electronics
Analyzed by UV-VIS
Acid Added For Digestion
HNO3,HCl,HF,H2O2,H3BO3
HNO3,HCl,HF
HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected.
Page 5 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00202737S1
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Halogen Content
Reference Standard:EN 14582
Sampling/grinding or
cutting
Add absorbent in a
combustion flask &
place weighed sample in
equipment
Fill oxygen into
calorimetric bomb
Ignite then leave the
flask at room
temperature
Transfer the absorbent
into a volumetric flask
Make up with deionized
water
Analyzed by ion
chromatography
End Of Report
Page 6 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00202737S1
Test Conducted
Photo
Page 7 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00232333
Test Report
Applicant:
Littelfuse Philippines Inc.
LIMA Technology Center, Lipa City,
Malvar, Batangas
Date
: Nov 18, 2011
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: Ceramic Paper
Part Number
: 009116
Date Sample Received
: Nov 11, 2011
Date Test Started
: Nov 14, 2011
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
This report shall not be reproduced
except in full, without the written
approval of the laboratory.
Page 1 of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00232333
Test Conducted
(Ⅰ) Test Result Summary :
Test Item
Result (ppm)
White Material
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content
Polybrominated Biphenyls (PBBs)
Monobrominated Biphenyls (MonoBB)
Dibrominated Biphenyls (DiBB)
Tribrominated Biphenyls (TriBB)
Tetrabrominated Biphenyls (TetraBB)
Pentabrominated Biphenyls (PentaBB)
Hexabrominated Biphenyls (HexaBB)
Heptabrominated Biphenyls (HeptaBB)
Octabrominated Biphenyls (OctaBB)
Nonabrominated Biphenyls (NonaBB)
Decabrominated Biphenyl (DecaBB)
Polybrominated Diphenyl Ethers (PBDEs)
Monobrominated Diphenyl Ethers (MonoBDE)
Dibrominated Diphenyl Ethers (DiBDE)
Tribrominated Diphenyl Ethers (TriBDE)
Tetrabrominated Diphenyl Ethers (TetraBDE)
Pentabrominated Diphenyl Ethers (PentaBDE)
Hexabrominated Diphenyl Ethers (HexaBDE)
Heptabrominated Diphenyl Ethers (HeptaBDE)
Octabrominated Diphenyl Ethers (OctaBDE)
Nonabrominated Diphenyl Ethers (NonaBDE)
Decabrominated Diphenyl Ether (DecaBDE)
Halogen Content
Fluorine (F)
Chlorine (Cl)
Bromine (Br)
Iodine (I)
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
Remarks: ppm = Parts per million based on weight of tested sample = mg/kg
ND = Not detected
Responsibility of Chemist : Irene Chiou / Kevin Liu / Cathy Chen
Date Sample Received
Test Period
: Nov 11, 2011
: Nov 14, 2011 To Nov 16, 2011
Page 2 of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Test Conducted
(Ⅱ) RoHS Requirement:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Polybrominated Biphenyls (PBBs)
Polybrominated Diphenyl Ehters (PBDEs)
Number : TWNC00232333
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for
homogeneous material.
(Ⅲ) Test Method:
Test Item
Cadmium (Cd)
content
Lead (Pb) content
Mercury (Hg)
content
Chromium VI (Cr6+)
content
Polybrominated
Biphenyls (PBBs)
Polybrominated
Diphenyl Ethers
(PBDEs)
Halogen Content
Test Method
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 7, by microwave
digestion until the tested samples are
totally dissolved and determined by
ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in annex C, by alkaline
digestion and determined by UV-Vis
spectrophotometer.
With reference to IEC 62321 edition
1.0:2008 in annex A, by solvent
extraction and determined by GC-MSD
and further HPLC confirmation when
necessary.
With reference to IEC 62321 edition
1.0:2008 in annex A, by solvent
extraction and determined by GC-MSD
and further HPLC confirmation when
necessary.
With reference to EN 14582:2007 by
calorimetric bomb with oxygen and
determined by ion chromatography
Reporting Limit
2 ppm
2 ppm
2 ppm
1 ppm
5 ppm
5 ppm
50 ppm
Remark: Reporting limit = Quantitation limit of analyte in sample
Page 3 of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00232333
Test Conducted
(Ⅳ) Measurement Flowchart:
Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents
Reference Standard: IEC 62321 edition 1.0:2008
Sample preparation
For non-metal part
For metal part
Take sample and immerse into Aqua Regia, start to strip plating layer
Stop the stripping procedure upon color change completely
Take the Aqua solution as plating component and stripped body as substrate component
Cd/Pb/Hg
Cr
Confirm the tested
samples are
totally dissolved
Make up with
deionized water
PBBs/PBDEs
Polymers /
electronics
Metal
For different
material, digest
the sample with
*1
appropriate acid
6+
Weigh sample and
add organic solvent
By spot test
Negative
Get 50cm2 sample
By boiling water
extraction
*2
Weigh sample
and add
alkaline
solution
By Soxhlet
extraction or
Solvent extraction
Definite temp.
extraction
Cool and filter
the extract
Analyzed by ICP-OES
Concentrate the
extract and make up
with organic
solvent
Analyzed by GC-MSD
Make up with deionized
water and add diphenylcarbazide solution
Remarks:
*1: List of Appropriate Acid:
Material
Polymers
Metals
Electronics
Analyzed by UV-VIS
Acid Added for Digestion
HNO3,HCl,HF,H2O2,H3BO3
HNO3,HCl,HF
HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected.
Page 4 of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00232333
Test Conducted
(Ⅳ) Measurement Flowchart:
Test for Halogen Content
Reference Standard:EN 14582
Sampling/grinding or
cutting
Add absorbent in a
combustion flask &
place weighed sample in
equipment
Fill oxygen into
calorimetric bomb
Ignite then leave the
flask at room
temperature
Transfer the absorbent
into a volumetric flask
Make up with deionized
water
Analyzed by ion
chromatography
End of Report
Page 5 of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00232333
Test Conducted
Photo
Page 6 of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00232329
Test Report
Applicant:
Littelfuse Philippines Inc.
LIMA Technology Center, Lipa City,
Malvar, Batangas
Date
: Nov 18, 2011
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: Yarn(GLZZXXX-6481XX)
Part Number
: 648118
Date Sample Received
: Nov 11, 2011
Date Test Started
: Nov 14, 2011
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
This report shall not be reproduced
except in full, without the written
approval of the laboratory.
Page 1 of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00232329
Test Conducted
(Ⅰ) Test Result Summary :
Test Item
Result (ppm)
White Yarn
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content
Polybrominated Biphenyls (PBBs)
Monobrominated Biphenyls (MonoBB)
Dibrominated Biphenyls (DiBB)
Tribrominated Biphenyls (TriBB)
Tetrabrominated Biphenyls (TetraBB)
Pentabrominated Biphenyls (PentaBB)
Hexabrominated Biphenyls (HexaBB)
Heptabrominated Biphenyls (HeptaBB)
Octabrominated Biphenyls (OctaBB)
Nonabrominated Biphenyls (NonaBB)
Decabrominated Biphenyl (DecaBB)
Polybrominated Diphenyl Ethers (PBDEs)
Monobrominated Diphenyl Ethers (MonoBDE)
Dibrominated Diphenyl Ethers (DiBDE)
Tribrominated Diphenyl Ethers (TriBDE)
Tetrabrominated Diphenyl Ethers (TetraBDE)
Pentabrominated Diphenyl Ethers (PentaBDE)
Hexabrominated Diphenyl Ethers (HexaBDE)
Heptabrominated Diphenyl Ethers (HeptaBDE)
Octabrominated Diphenyl Ethers (OctaBDE)
Nonabrominated Diphenyl Ethers (NonaBDE)
Decabrominated Diphenyl Ether (DecaBDE)
Halogen Content
Fluorine (F)
Chlorine (Cl)
Bromine (Br)
Iodine (I)
ND
7
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
Remarks: ppm = Parts per million based on weight of tested sample = mg/kg
ND = Not detected
Responsibility of Chemist : Irene Chiou / Kevin Liu / Cathy Chen
Date Sample Received
Test Period
: Nov 11, 2011
: Nov 14, 2011 To Nov 17, 2011
Page 2 of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00232329
Test Conducted
(Ⅱ) RoHS Requirement:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Polybrominated Biphenyls (PBBs)
Polybrominated Diphenyl Ehters (PBDEs)
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for
homogeneous material.
(Ⅲ) Test Method:
Test Item
Cadmium (Cd)
content
Lead (Pb) content
Mercury (Hg)
content
Chromium VI (Cr6+)
content
Polybrominated
Biphenyls (PBBs)
Polybrominated
Diphenyl Ethers
(PBDEs)
Halogen Content
Test Method
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 7, by microwave
digestion until the tested samples are
totally dissolved and determined by
ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in annex C, by alkaline
digestion and determined by UV-Vis
spectrophotometer.
With reference to IEC 62321 edition
1.0:2008 in annex A, by solvent
extraction and determined by GC-MSD
and further HPLC confirmation when
necessary.
With reference to IEC 62321 edition
1.0:2008 in annex A, by solvent
extraction and determined by GC-MSD
and further HPLC confirmation when
necessary.
With reference to EN 14582:2007 by
calorimetric bomb with oxygen and
determined by ion chromatography
Reporting Limit
2 ppm
2 ppm
2 ppm
1 ppm
5 ppm
5 ppm
50 ppm
Remark: Reporting limit = Quantitation limit of analyte in sample
Page 3 of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00232329
Test Conducted
(Ⅳ) Measurement Flowchart:
Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents
Reference Standard: IEC 62321 edition 1.0:2008
Sample preparation
For non-metal part
For metal part
Take sample and immerse into Aqua Regia, start to strip plating layer
Stop the stripping procedure upon color change completely
Take the Aqua solution as plating component and stripped body as substrate component
Cd/Pb/Hg
Cr
Confirm the tested
samples are
totally dissolved
Make up with
deionized water
PBBs/PBDEs
Polymers /
electronics
Metal
For different
material, digest
the sample with
*1
appropriate acid
6+
Weigh sample and
add organic solvent
By spot test
Negative
Get 50cm2 sample
By boiling water
extraction
*2
Weigh sample
and add
alkaline
solution
By Soxhlet
extraction or
Solvent extraction
Definite temp.
extraction
Cool and filter
the extract
Analyzed by ICP-OES
Concentrate the
extract and make up
with organic
solvent
Analyzed by GC-MSD
Make up with deionized
water and add diphenylcarbazide solution
Analyzed by UV-VIS
Remarks:
*1: List of Appropriate Acid:
Material
Polymers
Metals
Electronics
Acid Added for Digestion
HNO3,HCl,HF,H2O2,H3BO3
HNO3,HCl,HF
HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected.
Page 4 of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00232329
Test Conducted
(Ⅳ) Measurement Flowchart:
Test for Halogen Content
Reference Standard:EN 14582
Sampling/grinding or
cutting
Add absorbent in a
combustion flask &
place weighed sample in
equipment
Fill oxygen into
calorimetric bomb
Ignite then leave the
flask at room
temperature
Transfer the absorbent
into a volumetric flask
Make up with deionized
water
Analyzed by ion
chromatography
End of Report
Page 5 of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00232329
Test Conducted
Photo
Page 6 of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401