PANASONIC ALFG2PF12

LF (ALF)
VDE
Load for air conditioner
1a 20A power relays
TMP type
PCB type
RoHS compliant
LF RELAYS (ALF)
FEATURES
TYPICAL APPLICATIONS
1. Ideal for compressor and inverter
loads
1) Compressor load: 20A 250V AC
2) Inverter load: 20A 100V AC,
10A 200V AC
2. High insulation resistance
• Creepage distance and clearances
between contact and coil;
Creepage Min. 9.5mm .374inch/
Clearance Min. 8mm .315inch
• Surge withstand voltage: 10,000V
3. “PCB” and “TMP” types available
4. Conforms to the various safety
standards:
UL/C-UL, TÜV and VDE approved
• Air conditioner
• Refrigerators
• OA equipment
ORDERING INFORMATION
ALF
LF relay
Contact arrangement
1: 1 Form A
Terminal shape
T: TMP type
P: PCB type
Nominal coil voltage, V DC
05: 5, 06: 6, 09: 9, 12: 12, 18: 18, 24: 24
Note: Certified by UL/C-UL,VDE and TÜV
TYPES
Contact arrangement
Nominal coil voltage
1 Form A
5V DC
6V DC
9V DC
12V DC
18V DC
24V DC
Part No.
TMP type
ALF1T05
ALF1T06
ALF1T09
ALF1T12
ALF1T18
ALF1T24
PCB type
ALF1P05
ALF1P06
ALF1P09
ALF1P12
ALF1P18
ALF1P24
Standard packing: Carton 50 pcs., Case 200 pcs.
RATING
1. Coil data
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
5V DC
180 mA
27.8Ω
6V DC
9V DC
12V DC
18V DC
24V DC
150 mA
100 mA
75 mA
50 mA
37.5mA
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
70%V or less of
nominal voltage
(Initial)
ASCTB195E 201202-T
Drop-out voltage
(at 20°C 68°F)
10%V or more of
nominal voltage
(Initial)
Panasonic Corporation
40
90
160
360
640
Ω
Ω
Ω
Ω
Ω
Automation Controls Business Unit
Nominal operating
power
(at 20°C 68°F)
Max. applied voltage
(at 20°C 68°F)
900mW
110%V of
nominal voltage
industrial.panasonic.com/ac/e/
LF (ALF)
2. Specifications
Characteristics
Contact
Rating
Item
Contact material
Arrangement
Contact resistance (Initial)
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
Max. switching current
Nominal operating power
Min. switching capacity (reference value)*1
Insulation resistance (Initial)
Between open contacts
Between contact and coil
Breakdown voltage
(Initial)
Electrical
characteristics
Temperature rise (coil)
Surge breakdown voltage*2
(Between contact and coil) (Initial)
Operate time (at nominal voltage) (at 20°C 68°F)
Release time (at nominal voltage) (at 20°C 68°F)
Functional
Destructive
Functional
Vibration resistance
Destructive
Mechanical (at 180 times/min.)
Electrical (at 20 times/min.)
Shock resistance
Mechanical
characteristics
Expected life
Conditions for operation, transport and storage*3
Conditions
Max. operating speed
Unit weight
Specifications
AgSnO2 type
1 Form A
Max. 100 mΩ (By voltage drop 6 V DC 1A)
20A 250V AC
6,250VA
250V AC
25A
900mW
100mA, 5V DC
Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
1,000 Vrms for 1 min. (Detection current: 10 mA)
5,000 Vrms for 1 min. (Detection current: 10 mA)
Max. 45°C 113°F (By resistive method, nominal coil voltage applied to the coil;
contact carrying current: 20A, at 60°C 140°F)
10,000 V
Max. 20 ms (excluding contact bounce time.)
Max. 15 ms (excluding contact bounce time) (With diode)
100 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 1.5 mm
Min. 2×106
Min. 105 (resistive load)
Ambient temperature: –40°C to +60°C –40°F to +140°F,
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 times/min. (at nominal switching capacity)
Approx. 23 g .81 oz
* Specifications will vary with foreign standards certification ratings.
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
3. Switching capacity
20 A, 250 V AC (cosφ = 1)
Min. 105
(at 20 times/min.)
25 A, 250 V AC (cosφ = 1)
Min. 104
(at 20 times/min.)
Min. 105
(at 20 times/min.)
Min. 3×104
(at 10 times/min.)
Min. 3×104
(at 10 times/min.)
Resistive load
Inrush 70 A (cosφ = 0.7), Steady 20 A (cosφ = 0.9)
250 V AC
Inrush 200 A, Steady 20 A
100 V AC
Inrush 100 A, Steady 10 A
200 V AC
Compressor load
Electrical Life
Inverter load
REFERENCE DATA
2-(1). 200V AC electrical life test
(200V AC, inverter load)
Sample: ALF1T12, 6 pcs.
Point measured: coil inside
Contact current: 20A
Ambient temperature: 25°C 77°F, 60°C 140°F
Temperature rise, °C °F
70
158
25°C 77°F
60°C 140°F
60
140
Sample: ALF1T12, 6 pcs.
Load: Inrush 102A (wave peak value),
Steady 14.4A (wave peak value)
Inverter dummy 200V AC
Switching frequency: ON 1s, OFF 5s
Circuit:
50
122
LF relay contact
40
104
30
86
200V AC
1.9Ω
20
68
10
50
0
32
2,000µF
Switch
80
100
12
Pick-up and drop-out voltage, V
1. Coil temperature rise
Contact welding: 0 times
Miscontact: 0 times
10
Pick-up voltage
6
Drop-out voltage
Min.
2
0
3
6
No. of operations, ×104
Coil applied voltage, %V
Panasonic Corporation
Max.
x
4
0
120
Max.
x
Min.
8
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
ASCTB195E 201202-T
LF (ALF)
2-(2). 100V AC electrical life test
(100V AC, inverter load)
Sample: ALF1T12, 6 pcs.
Load: Inrush 224A (wave peak value),
Steady 30.5A (wave peak value)
Inverter dummy 100V AC
Switching frequency: ON 1s, OFF 5s
Circuit:
LF relay contact
470µF
2,000µF
100V AC
470µF
Pick-up and drop-out voltage, V
12
Contact welding: 0 times
Miscontact: 0 times
10
Pick-up voltage
8
Max.
x
6
Min.
Drop-out voltage
Max.
x
Min.
4
2
0
0
3
6
No. of operations, ×104
2-(3). Inrush 70.7A, Steady 20A, 250V AC
electrical life test (Compressor dummy load)
2-(4). Electrical life test
(20A 250V AC, resistive load)
Sample: ALF1T12, 3 pcs.
Load: Inrush 70.7A, cosφ = 0.7
Steady 20A, cosφ 0.9
250V AC compressor dummy
Switching frequency: ON 1.5s, OFF 1.5s
Circuit:
Sample: ALF1T12, 6 pcs.
Switching frequency: ON 1.5s, OFF 1.5s
Mg
250V AC
(–)
60Hz
12V DC
SW1
(+)
Detection
Circuit
Contact Weld
Min. 0.5s
Miss Contact
after 0.2s
Contact welding: 0 times
Miscontact: 0 times
10
8
Pick-up voltage
Max.
x
Min.
6
4
Max.
x
Min.
Drop-out voltage
G
2
0
Contact welding: 0 times
Miscontact: 0 times
10
Pick-up voltage
8
Max.
x
Min.
6
Drop-out voltage
Max.
x
4
Min.
2
0
5
No. of operations,
ASCTB195E 201202-T
Pick-up and drop-out voltage, V
NO
Pick-up and drop-out voltage, V
COM
12
12
Panasonic Corporation
10
×104
Automation Controls Business Unit
0
0
10
No. of operations, ×104
industrial.panasonic.com/ac/e/
20
LF (ALF)
DIMENSIONS (mm inch)
The CAD data of the products with a
CAD Data
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
1. TMP type
PC board pattern (Bottom view)
External dimensions
CAD Data
11.25
.443
12.8
.504
#250 terminal
27.6 ±0.1
1.087 ±.004
6.4
.252
2.0
.079
2
.0 dia.
79
dia
13.8 ±0.1
.543 ±.004
a.
di ia.
d
79
2
.0
.
12.0 ±0.1
.472 ±.004
ALF1T12
20A277VAC
COSφ=1
20A250V
SPULE;12V
23.3
.917
a.
di ia.
8 d
1. 71
.0
0.5
.020
MADE IN THAILAND
22.0
.866
27.6
1.087
10.0 ±0.1
.394 ±.004
Tolerance: ±0.1 ±.004
4.0
.157
12.0
.472
Lot No.
12.0 ±0.1
.472 ±.004
1
.07 .8 d
1 d ia.
ia.
Schematic (Bottom view)
FASTON 250
30.1
1.185
3 NO COM 4
NO
15.7
.618
COM
PC board side
1
2
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch:
Min. 3mm .118 inch:
Tolerance
±0.1 ±.004
±0.2 ±.008
±0.3 ±.012
2. PCB type
External dimensions
CAD Data
PC board pattern (Bottom view)
27.6 ±0.1
1.087 ±.004
ALF1P12
20A277VAC
23.3
.917
COSφ=1
20A250V
SPULE;12V
2
.0 dia.
79
dia
13.8 ±0.1
.543 ±.004
a.
di ia.
d
79
2
.0
.
0.5
.020
MADE IN THAILAND
22.0
.866
27.6
1.087
Lot No.
12.0 ±0.1
.472 ±.004
4.0
.157
12.0
.472
a.
di ia.
8 d
1. 71
.0
30.1
1.185
12.0 ±0.1
.472 ±.004
10.0 ±0.1
.394 ±.004
1
.07 .8 d
1 d ia.
ia.
Tolerance: ±0.1 ±.004
3 NO COM 4
Schematic (Bottom view)
15.7
.618
1
2
NO
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch:
Min. 3mm .118 inch:
COM
Tolerance
±0.1 ±.004
±0.2 ±.008
±0.3 ±.012
SAFETY STANDARDS
File No.
E43028
UL/C-UL (Recognized)
Contact rating
25A 277V AC
20A 277V AC
File No.
40009169
VDE (Certified)
Contact rating
20A 250V AC (cosφ =1.0)
TV rating (UL/CSA)
File No.
Rating
UL
TV-8
E43028
File No.
B 11 04
13461 295
TÜV (Certified)
Rating
20A 250V AC (cosφ =1.0)
* CSA standard: Certified by C-UL
For Cautions for Use.
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
ASCTB195E 201202-T
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Panasonic:
ALFG1PF09 ALFG1PF12 ALFG1PF18 ALFG1PF24 ALF1M05 ALF1M06 ALF1M09 ALF1M12 ALF1M18
ALF1M24 ALF1P05 ALF1P06 ALF1P09 ALF1P18 ALF1P12 ALF1T24 ALF1T12 ALF1P24 ALF1PF12 ALF1T05
ALF1T06 ALF1T09 ALF1T18 ALF1TF12 ALF1TF24 ALFG2PF12