LITTELFUSE SL1411A

Gas Discharge Tubes
Heavy Duty Delta Range
RoHS
SL1411A Series Two-terminal Gas Plasma Arrester
Pb
®
The Greentube™ SL1411A (Delta) Series Gas Plasma Arrester
(improved gas discharge tube (GDT)) features is a highperformance transient voltage suppressor designed for heavyduty protection of telecom and industrial equipment.
The Delta range offers high levels of performance and durability
on fast-rising transients in the domain of 100 V/µS to 1 kV/µS,
which are those most likely from induced lightning disturbances.
The high surge rating of these devices makes them ideal for
arduous service conditions and Outside Plant locations.
The Delta range also features ultra low capacitance (typically 1 pF
or less) and optimized internal geometry which provides low
insertion loss at high frequencies, so are ideal for the protection
of broadband equipment.
FEATURES
• RoHS compliant and Lead-free
6.0±0.2
8.0 ±0.2
• Can be used to meet the requirements of GR-1361, RUS PE-80,
ITU K.12 and YD/T940, 950, 1082, 993, 694
8
GAS DISCHARGE
TUBES
• Excellent response to fast rising transients
• Up to 1.5 gHz working frequency
• 10 kA surge capability tested with 8/20µS pulse as defined by
IEC 61000-4-5 (20 kA for 90 V)
• 20,000 A single shot surge capability tested with 8/20µs
SL1411AxxxA
pulse as defined by IEC 61000-4-5
5.4
• Excellent service life characteristics
6.0±0.3
Applications:
• Outside Plant and MDF protector modules.
7.0
• ADSL equipment.
8.0 ±0.2
• XDSL equipment (including ADSL2, VDSL, VDSL2).
• Satellite and CATV equipment.
• General telecom equipment.
1.3
SL1411AxxxSM
RECOMMENDED PAD LAYOUT
6.0±0.2
• Cell phone base stations.
8.0 ±0.2
GDT SHOWING SEATING PLANE
FOR SL1411AxxxSM
0.8
SL1411AxxxC
2 ELECTRODE GDT
ORDERING INFORMATION
SL 1411 A
All dimensions in mm
Mechanical Specifications:
Weight:
Materials:
Surge Capability
A= 5kA
Voltage
Device Marking:
Pin Configuration
2.7g (0.095 oz.)
Electrode Base: Nickel Iron Alloy
Electrode Plating: Bright Sn
Body: Ceramic
Littelfuse ‘LF’ marking, Voltage and
date code.
SM= Surface Mount
C= Core
A= Axial Leaded
w w w. l i t t e l f u s e . c o m
358
Gas Discharge Tubes
Heavy Duty Delta Range
RoHS
Pb
SL1411A Series Two-terminal Gas Plasma Arrester
DC Breakover
Voltage @100 V/s1,2
Volts
Part
Number*
SL1411A075
MAX Dynamic
Breakover
Voltage3
100 V/µs
Volts
450
1kV/µs
Volts
700
AC
Discharge
Current4
Amps
10
Max
Repetitive
Impulse
Current3
kAmps
10
MAX Single
Impulse Current
8/20 µs 10/350 µs
kAmps
kAmps
20
3
Max
Leakage
Current 6
nAmps
50
®
Holdover
Voltage 7,8
Volts
50
Nominal
On-state
Voltage
@1A
Volts
20
MIN
60
MAX
90
SL1411A090
72
108
450
700
10
10
20
3
50
50
20
SL1411A230
184
276
450
650
10
10
20
3
100
135
20
SL1411A250
200
300
475
700
10
10
20
3
100
135
20
SL1411A350
280
420
600
800
10
10
20
3
100
135
20
SL1411A470
400
540
700
1000
10
10
20
3
100
135
20
SL1411A600
510
690
850
1100
10
10
20
3
100
135
20
SL1411A800
680
920
1100
1300
10
10
20
3
100
135
20
SL1411A1000
850
1150
1300
1500
10
10
20
3
100
135
20
*Max capacitance is 1.5 pF, measured at 1 MHz.
Notes:
1. At delivery AQL 0.65 level II, DIN ISO 2859
2. In ionized mode
3. Comparable to the silicon measurement Switching Voltage (Vs)
4. 10 shots, AC 60 Hz, 1µs duration
5. 10 shots, 8/20 µs waveform
6. Measured at 100 V, except for devices 90 VDC which are measured at 50 V
7. With network applied, 52V for 75 VDC and 90VDC ratings
8. Tested according to ITU-T Rec. K 12
Service Life Rating
Voltage vs Time Characteristic
10A, 10/1000µs, 1500 operations
100A, 10/1000µs, 100 operations
Max dynamic breakover
voltage
Voltage
(V)
300A, 10/1000µs, 50 operations
Hold-over voltage
On-State voltage
0
200
400
600
800
1000
1200
Time (ns)
359