LITTELFUSE SL1003

Gas Discharge Tubes
High Performance Beta Range
RoHS
Pb
Greentube™ SL1003 Series Gas Plasma Arresters
®
The SL1003 series has been especially developed for Broadband
equipment. Unique design features offer high levels of performance on fast rising transients in the domain of 100V/µS to
1KV/µS, which are those most likely from induced Lightning disturbances. These devices have Ultra low capacitance ( typically
1.2pF or less ) and present insignificant signal losses up to
1.5GHz. These devices are extremely robust and are able to
divert a 5000A pulse without destruction. For AC Power Cross of
long duration, overcurrent protection is recommended.
FEATURES
• RoHS compliant
• Low insertion loss
• Surface mountable
• 5KA surge capability tested with 8/20µS pulse as defined by
IEC 61000-4-5
• GHz working frequency.
• Excellent response to fast rising transients.
• Can be used to meet Telcordia GR1089 without
series resistance
• 10/700 6KV capability, as per ITUT k.21, enhanced test level
• 2000 Amp 2/10µS surge rating
Applications:
• Broadband equipment.
• ADSL equipment.
• XDSL equipment.
• Satellite and CATV equipment.
• General telecom equipment.
3 ELECTRODE GDT
GRAPHICAL SYMBOL
ORDERING INFORMATION
SL 1003 A XXX
All dimensions in mm
Pin Configuration
Voltage
Type
3 Pole Arrester
C= Core
R= Leaded
w w w. l i t t e l f u s e . c o m
331
Gas Discharge Tubes
High Performance Beta Range
RoHS
Pb
Greentube™ SL1003 Series Gas Plasma Arresters
®
LITTELFUSE 3 TERMINAL MINI ARRESTER SERIES
TOTALLY NON-RADIOACTIVE, UL RECOGNIZED
Part Number
Max Dynamic Max Dynamic Max Repetitive
Breakover
Impulse
Breakover
DC Voltage
Voltage @
Discharge
Voltage @
@100V/sec
100 V/µs (Vbr) 1 kV/µs (Vbr) Current2 (kA)
(V)
SL1003A090
90
600
700
5
SL1003A230
350
500
SL1003A250
SL1003A260
230
250
260
400
SL1003A300
300
SL1003A350
SL1003A400
SL1003A450
350
600
600
650
700
800
800
5
5
5
5
5
5
5
420
450
500
550
650
400
450
Nominal
Max
Holdover On-State
Alternating
4
1
Capacitance
Voltage Voltage @
Discharge
(pF)
(V)
Current3 (A)
1A (V)
1.2
9
50
5
20
1x10 @50V
1.2
135
5
20
1x109 @100V
1.2
135
5
20
1x109 @100V
Insulation
Resistance7
(Ω)
1x109 @100V
1x109 @100V
1x109 @100V
1x109 @100V
1x109 @100V
5
5
5
5
5
1.2
1.2
1.2
1.2
1.2
135
135
135
135
135
20
20
20
20
20
Notes:
(1) Tested according to ITU-T Rec.K12
(2) 10 shots, 8/20µs wave form per IEC 61000-4-5
(3) Measured @ 100 Volts
(4) Measured @ 1 MHz, 0 volt bias
8
GAS DISCHARGE
TUBES
(5) Measured with 2/10µs wave form
(6) Measured with 10/350µs wave form
(7) Measured @ 100VDC except 90V which is measured at 50VDC
Voltage vs Time Characteristic
Typical Inser
tion loss figures
Max dynamic breakover
voltage
@1.0 GHz = 0.01dB
@1.4 GHz = 0.1dB
Voltage
(V)
@1.8 GHz = 0.53dB
@2.1 GHz = 0.81dB
@2.45 GHz = 1.0dB
@2.8 GHz = 1.2dB
Hold-over voltage
@3.1 GHz= 1.5dB
On-State voltage
0
200
400
600
800
1000
@3.5 GHz = 2.1dB
1200
Time (ns)
332
w w w. l i t t e l f u s e . c o m
Gas Discharge Tubes
High Performance Beta Range
RoHS
Pb
Greentube™ SL1003 Series Gas Plasma Arresters
Profile for reflow soldering
®
Profile for wave soldering
250
300
225
T 1 max = 266oC
Solder
Flow Area
175
150
T 1 = 239oC
125
100
200
75
Temperature (˚C)
Temperature ˚C
200
50
25
0
0
50
100
150
200
250
300
Time in seconds
350
400
450
Tm = 179oC
Forced Cooling
Preheating
Area
500
100
10
20
30
40
Time(seconds)
Notes:
T1 max
T1
Tm
o
= Maximum TabTemperature = 266 C
= Flow Tempearture of Solder = 239oC
o
= Melting Point of Solder = 179 C
Tamb
= 25 C
o
o
Maximum permissible rate of temperature change = 7C / sec
w w w. l i t t e l f u s e . c o m