LITTELFUSE SL1002A260

Gas Discharge Tubes
High Performance Beta Range
RoHS
Greentube™ SL1002 Series Gas Plasma Arresters
Pb
®
The Broadband Optimized™ SL1002 series has been especially
developed for use in broadband equipment. Unique design features offer high levels of performance on fast rising transients in
the domain of 100V/µS to 1KV/µS, which are those most likely
from induced Lightning disturbances. These devices have Ultra
low capacitance (typically 1.2pF or less) and present insignificant
signal losses up to 1.5GHz. These devices are extremely robust
and are able to divert a 5000A pulse without destruction. For AC
Power Cross of long duration, overcurrent protection is recommended.
FEATURES
• RoHS compliant
• Ultra Low Insertion Loss
• Surface mountable
• 5KA surge capability tested with 8/20µS pulse
as defined by IEC 61000-4-5
• Excellent response to fast rising transients.
• Can be used to meet Telcordia GR1089
without series resistance
• 10/700 6KV capability, as per ITUT k.21, enhanced test level
• 2000 Amp 2/10µS surge rating
• Meets FCC part 68 10/160µs waveform, 200A test and
8
10/560µs waveform 100A test.
GAS DISCHARGE
TUBES
Applications:
• Broadband equipment.
• ADSL equipment.
• XDSL equipment.
• Satellite and CATV equipment.
• General telecom equipment.
2 ELECTRODE GDT
GRAPHICAL SYMBOL
ORDERING INFORMATION
SL 1002 A XXX
All dimensions in mm
Mechanical Specifications:
SM=Surfacemount
Voltage C= Core
Weight:
Materials:
Type
2 Pole Arrester
Device Marking:
w w w. l i t t e l f u s e . c o m
0.63g (0.022 oz.)
Electrode Base: Nickel Iron Alloy
Electrode Plating: Bright Sn
Body: Ceramic
‘LF’ logo, Voltage and date code
323
Gas Discharge Tubes
High Performance Beta Range
RoHS
Pb
Greentube™ SL1002 Series Gas Plasma Arresters
LITTELFUSE 2 TERMINAL MINI ARRESTER SERIES
TOTALLY NON-RADIOACTIVE, UL RECOGNIZED
Max Dynamic
DC Voltage Breakover
@ 100V/sec Voltage @
(V)
Part Number
100V/µs (Vbr)
SL1002A090
90
360
SL1002A230
230
400
SL1002A250
250
400
Max
Max Holdover Nominal
Max Dynamic Max Repetitive Max Single Max Single
Impulse
Leakage Capacit
Impulse
Impulse
Breakover
On-State
(1)
Discharge
Discharge Current(3) ance(4) Voltage
Voltage @ 1 Discharge
Voltage
(pF)
@ 1A (V)
(V)
(nA)
kV/µs (Vbr) Current(2) (kA) Current(5) (A) Current(6) (A)
2
50
1.2
20
2
100
700
5
2
135
1.2
20
2
100
500
5
500
5
2
2
100
1.2
135
20
20
SL1002A260
260
400
500
5
2
2
100
1.2
135
SL1002A350
350
500
600
5
2
2
100
1.2
135
20
SL1002A600
600
800
900
5
2
2
100
1.2
135
20
Notes:
(1) Tested according to ITU-T Rec.K12
(2) 10 shots, 8/20µs wave form per IEC 61000-4-5
(3) Measured @ 100 Volts
(4) Measured @ 1MHz, O volt bias
(5) Measured with 2/10µs wave form
(6) Measured with 10/350µs wave form
Voltage vs Time Characteristic
Max dynamic breakover
voltage
Typical Insertion loss figures
@1.0 GHz = 0.01dB
@1.4 GHz = 0.1dB
Voltage
(V)
@1.8 GHz = 0.53dB
@2.1 GHz = 0.81dB
@2.45 GHz = 1.0dB
@2.8 GHz = 1.2dB
Hold-over voltage
@3.1 GHz= 1.5dB
On-State voltage
0
200
400
600
800
1000
@3.5 GHz = 2.1dB
1200
Time (ns)
324
w w w. l i t t e l f u s e . c o m
®
Gas Discharge Tubes
High Performance Beta Range
RoHS
Pb
Greentube™ SL1002 Series Gas Plasma Arresters
Profile for reflow soldering
®
Profile for wave soldering
250
300
225
T 1 max = 266oC
Solder
Flow Area
175
150
T 1 = 239oC
125
100
200
50
25
0
0
50
100
150
200
250
300
Time in seconds
350
400
450
Tm = 179oC
Forced Cooling
Preheating
Area
500
8
100
10
20
30
40
Time(seconds)
Notes:
T1 max
T1
Tm
Tamb
= Maximum TabTemperature = 266oC
= Flow Tempearture of Solder = 239oC
= Melting Point of Solder = 179oC
o
= 25 C
o
Maximum permissible rate of temperature change = 7C / sec
w w w. l i t t e l f u s e . c o m
325
GAS DISCHARGE
TUBES
75
Temperature (˚C)
Temperature ˚C
200