X

HHC12 Series
12-Inch Camera
Enclosure
Install Guide
Document 900.0559 – 04/06 – Rev 1.01
Revisions
Issue
Date
Revisions
1.00
07/05
New document rebranded to Honeywell standards,
based on KHM1000017 03/15/02
1.01
04/06
Added section Connecting the Heater/Blower
(HHC12WM2 Only), added supplied screws to
package contents, minor changes throughout
Rev 1.01
ii
Document 900.0559
04/06
Warnings
Installation and servicing should be performed only by qualified and
experienced technicians to conform to all local codes and to maintain
your warranty.
WARNING! The use of CSA Certified/UL Listed Class 2
power adapters is required to ensure
compliance with electrical safety standards.
Explanation of Graphical Symbols
THIS SYMBOL INDICATES THAT
DANGEROUS VOLTAGE
CONSTITUTING A RISK OF
ELECTRIC SHOCK IS PRESENT
WITHIN THE UNIT.
CAUTION
RISK OF ELECTRIC
SHOCK
DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRIC
SHOCK, DO NOT REMOVE THE COVER.
NO USER-SERVICEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL
Rev 1.01
iii
THIS SYMBOL INDICATES THAT
IMPORTANT OPERATING AND
MAINTENANCE INSTRUCTIONS
ACCOMPANY THIS UNIT.
Document 900.0559
04/06
Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Unpack Everything . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Equipment Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Preparing for Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Connecting the Heater/Blower (HHC12WM2 Model Only) . . . . . 4
Mounting the Camera . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Mounting the Wall Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Rev 1.01
Document 900.0559
04/06
Introduction
The HHC12 series camera housings are stylishly and functionally
designed for 1/2" and 1/3" CCD cameras with fixed focal length or small
zoom lenses.
Features
•
Contemporary design
•
Die-cast and extruded aluminum
construction
•
Adjustable mounting rack
•
Removable body for easy servicing
•
Indoor/outdoor
applications
•
Epoxy powder coating for corrison
resistance
•
IP66 rated
Ordering Information
Model No.
Description
Housing Models
HHC1200
12-inch housing
HHC12WM
12-inch housing with sunshield and HHMW13 wall mount
HHC12WM2 12-inch housing with sunshield, heater kit, blower kit and
HHMW13 wall mount
Optional Components
HHMC21J
Ceiling “J” mount, 21” high, 30 lbs (13.5 kg) max.
HHMCMA
Corner mount adapter for HHMW13
HHMPMA
Pole mount adapter for HHMW13
HHMW13
Wall mount, 13” high, 30 lbs (13.5 kg) max., grey
Rev 1.01
1
Document 900.0559
04/06
Before You Begin
This guide describes how to assemble the housing
and its optional components, affix the camera, and
mount the assembly to a suitable surface. Please read
this guide carefully before you install the housing.
Keep this guide for future reference.
Unpack Everything
Check that the items received match those listed on the order form and
packing slip. The HHC12 packing box includes, in addition to this guide:
Housing Model
Packing Includes
HHC1200
•
•
•
One 12-inch housing
One dessicant bag
Two UNC 1/4 x 20 machine screws
HHC12WM
•
•
•
•
•
One 12-inch housing with sunshield
One dessicant bag
One HHMW13 wall mount
Four 1/4 x 20 UNC machine screws
Four #14 1-1/4 sheet metal screws
HHC12WM2
•
•
•
•
•
One 12-inch housing with heater, blower and sunshield
One dessicant bag
One HHMW13 wall mount
Four 1/4 x 20 UNC machine screws
Four #14 1-1/4 sheet metal screws
If any parts are missing or damaged, contact the dealer you purchased
the housing from or call Honeywell Customer Service (see back cover).
Equipment Required
You may require the following tools (not supplied) to complete the
installation:
Screwdriver, camera and camera cable, power supply
Rev 1.01
2
Document 900.0559
04/06
Installation
To correcting install the heater/blower and mount the camera, please
follow the instructions in the order provided.
Preparing for Installation
1.
If applicable, move the sunshield by sliding it forward on the main
housing unit. Set the sunshield aside until needed.
2.
Unlatch the lid and open the upper body.
Unlatch lid
3.
4.
5.
Remove the dessicant bag from the protective packaging and place
the bag inside the housing to absorb moisture.
Close the housing.
Locate the gold, 1/4” x 20 panhead UNC screws and set them aside
for use later.
Rev 1.01
3
Document 900.0559
04/06
Connecting the Heater/Blower (HHC12WM2
Model Only)
Feed the external power supply (not included) through one of the
compression glands, then connect to the circuit board. The
recommended power supply is 24 VAC, 50VA.
Compression glands
from external 24
VAC power supply
J1
AC
GND
GND
AC/IN
Ground
C1
R1
FAN
GND
AC OUT
HEATER
VAC Out
to Heater
AC/Out
Ground
Ground
VDC
to Blower
B
Caution These wires must be connected for
the heater/blower/camera to operate.
to camera
Rev 1.01
4
Document 900.0559
04/06
Mounting the Camera
This section describes how to install a camera into any of the HHC12
series camera housings.
1.
Remove the mounting plate from the lower body by unscrewing one
Philips panhead screw. Set the screw aside.
2. Tilt mounting plate.
1. Unscrew panhead screw.
3. Secure camera with a 1/4 x 20
UNC screw.
2.
3.
4.
Tilt the mounting plate as shown.
Mount the camera onto the mounting plate and secure with the 1/2”
Philips panhead screw. You may need to turn the mounting plate
over to better accommodate your camera.
Place the mounting plate in its original position and secure the
assembling by tightening the Philips panhead screw through the
mounting plate into the lower body of the housing.
Rev 1.01
5
Document 900.0559
04/06
5.
Run the camera cable through the compression glands and make all
necessary electrical connections (refer to the guide that came with
your camera). Make sure that the compression glands are firmly
fixed.
4. Return mounting plate
to original position.
5. Run camera cable
through compression
glands.
6.
Reassemble the housing unit by closing the upper body and
latching the lid tight.
6. Latch the lid.
7.
If applicable, reinstall the sunshield by sliding it across the top of the
housing.
Rev 1.01
6
Document 900.0559
04/06
Mounting the Wall Bracket
To mount the wall bracket:
1.
2.
3.
4.
5.
Use fasteners of an appropriate size and type to attach the bracket
to the wall surface. Position the housing so that it allows for viewing
the selected area.
Locate the two nuts that freely slide along the channel. Position the
nuts approximately 2 inches from each other.
Place the housing onto the mount, aligning the holes. Insert the two
1/4"-20 UNC screws (supplied) through the mount and into the nuts
and tighten to secure the assembly.
Adjust the moveable arm of the wall bracket to attain the desired
position.
Tighten the bolt located at the pivot point of the movable arm and
tighten set screw.
1. Attach bracket to wall
using 4 sheet metal screws.
2. Position two
nuts 2” apart.
3. Secure housing with
2 x 1/4 x 20 UNC screws.
4. Adjust arm, then
tighten set screw.
Maintenance
Regularly scheduled maintenance prolongs the operational life and
appearance of equipment.
On a regular basis, perform the following:
•
•
Clean the viewing area window with a soft cloth using a mild
detergent and water to maintain picture quality.
Verify that all mounting hardware is secure.
Rev 1.01
7
Document 900.0559
04/06
Specifications
Housing Specifications
Dimensions:
(with sunshield)
5.8 x 4.6 x 16.0 in.
(147 x 118 x 406 mm)
Weight:
HHC1200
HHC12WM2
4.2 lbs (1.9 kg)
5.5 lbs (2.5 kg) (without mount)
Max. camera size:
Accommodates camera/lens combinations
(including BNC) up to:
HHC1200
HHC12WM
HHC12WM2
3.1 x 3.2 x 11.4 in (78 x 82 x 290 mm)
3.1 x 3.2 x 11.4 in (78 x 82 x 290 mm)
3.1 x 3.2 x 9.0 in (78 x 82 x 230 mm)
Viewing area:
2.9 x 2.4 in (73 x 61 mm)
Viewing window:
Clear 1/8” double-density glass
Construction:
Extruded and die-cast aluminum
Finish:
Epoxy power coating
Environment:
Indoor/outdoor: -4°F to 140°F (-20°C to 60°C)
IP66 rated
Camera mounting:
Slotted camera sled
Recommended mounts:
HHMC21J (Ceiling “J” mount)
HHMW13 (Wall mount)
HHMCMA (Corner mount adapter)
HHMPMA (Pole mount adapter)
Cable entry:
3 compression fittings: PG9, PG16, PG21
Rev 1.01
8
Document 900.0559
04/06
Sunshield Specifications
Dimensions:
(sunshield only)
5.8 x 4.6 x 16.0 in.
(147 x 118 x 406 mm)
Weight:
1.22 lbs (0.52 kg)
Heater (HHC12WM2) Specifications
Power Supply:
24 VAC
Power Consumption:
20 W
Heater ON:
Heater turns ON at 41°F (5°C)
Heater OFF:
Heater turns OFF at 59°F (15°C)
Blower (HHC12WM2) Specifications
Power Supply:
24 VAC
Power Consumption:
3.4 W
Blower ON:
Blower turns ON at 95°F (35°C)
Blower OFF:
Blower turns OFF at 68°F (20°C)
Rev 1.01
9
Document 900.0559
04/06
Honeywell Video Systems (Head Office)
2700 Blankenbaker Pkwy, Suite 150
Louisville, KY 40299, USA
www.honeywellvideo.com
℡ +1.800.796.2288
Honeywell Video Systems Northern Europe
Netwerk 121
1446 WV Purmerend, The Netherlands
www.SecurityHouse.nl
℡ +31.299.410.200
Honeywell Security Australia Pty Ltd.
Unit 5, Riverside Centre, 24-28 River Road West
Parramatta, NSW 2150, Australia
www.ademco.com.au
℡ +61.2.8837.9300
Honeywell Video Systems UK Ltd.
Aston Fields Road, Whitehouse Ind Est
Runcorn, Cheshire, WA7 3DL, UK
www.honeywellvideo.com
℡ +0844 8000 235
Honeywell Security Asia Pacific
33/F Tower A, City Center, 100 Zun Yi Road
Shanghai 200051, China
www.security.honeywell.com/cn
℡ +86 21.2527.4568
Honeywell Security South Africa
Unit 6 Galaxy Park, 17 Galaxy Avenue
Linbro Park, P.O. Box 59904
2100 Kengray, Johannesburg, South Africa
www.honeywell.co.za
℡ +27.11.574.2500
Honeywell Security Asia
Flat A, 16/F, CDW Building, 388 Castle Peak Road
Tsuen Wan, N.T., Hong Kong
www.security.honeywell.com/hk
℡ +852.2405.2323
Honeywell Security France
Parc Gutenberg, 8, Voie La Cardon
91120, Palaiseau, France
www.honeywell.com/security/fr
℡ +33.01.64.53.80.40
Honeywell Security Germany
Großenbaumer Weg 8
40472 Düsseldorf, Germany
www.honeywell-security.de
℡ +49.211.41.50.90
Honeywell Security Poland
Chmielewskiego 22a, 70-028
Szczecin, Polska
www.ultrak.pl
℡ +48.91.485.40.60
Honeywell Security Italia SpA
Via Treviso 2 / 4
31020 San Vendemiano
Treviso, Italy
www.honeywell.com/security/it
℡ +39.04.38.36.51
Honeywell Security Czech Republic
Havránkova 33, Brno
Dolní Heršpice, 619 00, Czech Republic
www.olympo.cz
℡ +420.543.558.111
Honeywell Security España
Calle Vivero, 5, 28040
Madrid, Spain
www.honeywell.com/security/es
℡ +34.91.102.5900
Honeywell Security Slovakia Republic
Vajnorská 142, 83104 Bratislava
Slovakia
www.olympo.sk
℡ +421.2.444.54.660
Video Systems
www.honeywellvideo.com
+1.800.796.CCTV (North America only)
Document 900.0559 Rev 1.01 04/06
© 2006 Honeywell International Inc. All rights reserved. No part of this publication may be
reproduced by any means without written permission from Honeywell Video Systems. The
information in this publication is believed to be accurate in all respects. However, Honeywell Video
Systems cannot assume responsibility for any consequences resulting from the use thereof. The
information contained herein is subject to change without notice. Revisions or new editions to this
publication may be issued to incorporate such changes.