Baumer electric Actuator-Sensor-Interface AS-Interface module ASIA 56A2411 Art.-Code: 137391 82 • Specification 2.11 41 44,5 • Standard addressing mode as S-slave; up to 31 modules mounting module base ø 4,4 (2x) 13,3 BUS EXT 38 35 (DIN rail) 56 bus cable energy cable 6 max. 75 • For two 3-wire sensors and two DC-motors 44 add. cable nut • Adress programming via jack EXT • Profile S - 7.F.F • Power supply for 2 sensors via bus • Fault diagnosis LED‘s ø 2,8 to 6,0 ø 16 20 bus data voltage supply range supply current reverse polarity protection E/A configuration ID-code / ID-2 code AS-i voltage indicator / error indicator inputs supply voltage for sensors short-circuit protection with feedback total current for sensors -25...+40 °C total current for sensors +40...+70 °C polarity of the inputs input current high / low input voltage high / low input indicator outputs switching element / polarity galvanic separation AS-i <>load circuit switching current per output Imax total current for outputs short-circuit protection / with feedback watchdog for bus monitoring external power supply for outputs voltage range external feed general protection class temperature range / storage temperature housing material specification power supply unit for external feed mounting EMC 20 25,5 20 connection diagram 26,5 - 33,1 VDC ≤ 200 mA yes 7 HEX F HEX / F HEX green LED / red LED AS-i AS-i + AS-i - D0 . . . D3 FET / H-bridges 2000 VDC 1,7 A 4A yes / peripheral error diagnosis LED yes via separate AS-i flat cable, black 10 - 30 VDC IP 65 (with EPDM-cable) -25...+70 °C / -25...+85 °C PBT / PC (UL 94 V-0) according to PELV DIN rail / screws refer to the AS-i brochure Baumer Electric AG Hummelstrasse 17 Postfach CH-8501 Frauenfeld Drawn: 03.12.03/rue Checked: 04.12.03/phw 2 0+ OUT1 Motor 1 H-bridge 0- OUT2 IN2 GND EX+ EX+ +VS IN1 0+ OUT1 H-bridge IN2 Motor 2 0- OUT2 GND general port assignment: P0, P1 D0, D1, D2, D3 input output possible conductor cross-sections: sensor terminals: 0,08...2,5 mm2, actuator terminals: 0,08...2,5 mm2 max. outer cable diameter: ø 2,8...6 mm diagnosis * ASI Error (green) (red) brake turns CCW turns CW brake * Status Description POWER OFF Address = 0 no data exchange no AS-i power Address = 0 Watchdog activated, Address = 0 ok - Sensor supply overload - Sensor supply shorted external supply: - overload / shorted ok external RESET, overload peripheral error LED dark * Diagnosis LED indicates a short circuit either of each half H-bridge to GND or VDD or a short circuit between the two half H-bridges. Overtemperature and low voltage were also indicated by the diagnosis LED. The error status can be removed by switching off the respective H-bridge, resetting the external power supply or resetting the ASi-Bus communication. 1 + IN +VS IN1 EXT+ EXT - 18 - 30 VDC yes ≤ 170 mA ≤ 130 mA PNP ≥ 1,5 mA / ≤ 0,5 mA > 10 VDC / < 5 VDC yellow LED + IN LED light Motor1 OUT1 0 0 1 1 LED flashing OUT2 0 1 0 1 Motor2 OUT3 0 0 1 1 OUT4 0 1 0 1 Technical specifications subject to change Tel. +41 52 728 11 22 Fax +41 52 728 11 44 Released: 22.08.05/phw Last change: