Baumer electric Actuator-Sensor-Interface AS-Interface module ASIA 56A4411 Art.-Code: 119158 • Specification 2.11 100 50 • Standard addressing mode as S-slave; up to 31 modules mounting module base • Fault diagnosis LED‘s ø 2,8 bis 6 • Output diagnosis feedback bus data voltage supply range supply current reverse polarity protection E/A configuration ID-code / ID-2 code AS-i voltage indicator / error indicator inputs supply voltage for sensors short-circuit protection with feedback total current for sensors -25...+40 °C total current for sensors +40...+70 °C polarity of the inputs input current high / low input voltage high / low input indicator outputs switching element / polarity galvanic separation AS-i <> load circuit switching current per output Imax total current for outputs short-circuit protection / with feedback watchdog for bus monitoring output indicator external power supply for outputs voltage range external feed max. load inductivity (mH) @ 2,3 A general protection class temperature range / storage temperature housing material specification power supply unit for external feed mounting EMC certificate no. 25 13 bus cable energy cable 35 (DIN rail) 3,5 • External power supply with flat cables for four actuators add. cable nut max.75 56 44 • Power supply for four 2-wire or 3-wire sensors via bus 54,5 • Profile S - 7.0.F 20 ø 4,4 (2x) 38 ø 16 20 20 20 connection diagram 26,5 - 33,1 VDC ≤ 240 mA yes 7 HEX 0 HEX / F HEX green LED / red LED 15 - 30 VDC yes ≤ 200 mA ≤ 150 mA PNP ≥ 5 mA / ≤ 1,5 mA > 11 VDC / < 5 VDC yellow LED FET / plus switching (PNP) 2000 VDC 2,3 A each 4A yes / peripheral error diagnosis LED yes yellow LED via separate AS-i flat cable, black 12 - 30 VDC ≤ 21 mH IP 65 (with EPDM cable) -25...+70 °C / -25...+85 °C PBT / PC (UL 94 V-0) according to PELV DIN rail / screws refer to the AS-i brochure 70802 Baumer Electric AG Hummelstrasse 17 Postfach CH-8501 Frauenfeld Drawn: 13.08.04/sli Checked: 19.08.04/phw AS-i AS-i + AS-i - P0 D0 . . . . . . P3 D3 + IN 1 + IN 2 + IN 3 + IN 4 0+ 0EX+ 0+ 0EX+ EXT+ EXT - 0+ 0EX+ 0+ 0EX+ 1 2 3 4 general port assignment: D0, D1, D2, D3 P0, P1, P2, P3 output input possible conductor cross-sections: sensor terminals: 0,08...2,5 mm2, actuator terminals: 0,08...2,5 mm2 max. outer cable diameter: ø 2,8...6 mm diagnosis ASI Error (green) (red) Status Description POWER OFF Address = 0 no data exchange no AS-i power Address = 0 Watchdog activated, Address = 0 ok - Sensor supply overload - Sensor supply shorted outputs: - overload / shorted ok external RESET, overload peripheral error LED dark LED light LED flashing - A periperal error at the outputs does not activate a master config. error - Break of output cables not monitored Technical specifications subject to change Tel. +41 52 728 11 22 Fax +41 52 728 11 44 Released: 18.01.06/phw Last change: Baumer electric Actuator-Sensor-Interface AS-Interface module ASIA 56A4321 Art.-Code: 152050 • Specification 2.11 100 50 • Extended addressing mode as A/B-slave; up to 62 modules mounting module base • Fault diagnosis LED‘s ø 2,8 bis 6 35 (DIN rail) 38 ø 16 20 • Output diagnosis feedback bus data voltage supply range supply current reverse polarity protection E/A configuration ID-code / ID-2 code AS-i voltage indicator / error indicator inputs supply voltage for sensors short-circuit protection with feedback total current for sensors -25...+40 °C total current for sensors +40...+70 °C polarity of the inputs input current high / low input voltage high / low input indicator outputs switching element / polarity galvanic separation AS-i <> load circuit switching current per output 1 / 2 / 3 Imax total current for outputs short-circuit protection / with feedback watchdog for bus monitoring output indicator external power supply for outputs voltage range external feed max. load inductivity (mH) output 1 / 2 @ 2,3 A max. load inductivity (mH) output 3 @ 3,3 A general protection class temperature range / storage temperature housing material specification power supply unit for external feed mounting EMC certificate no. 13 bus cable energy cable 3,5 • External power supply with flat cables for three actuators max.75 56 44 add. cable nut • Power supply for four 2-wire or 3-wire sensors via bus 25 54,5 • Profile S - 7.A.0 20 ø 4,4 (2x) 20 20 connection diagram 26,5 - 33,1 VDC ≤ 240 mA yes 7 HEX A HEX / 0 HEX green LED / red LED 15 - 30 VDC yes ≤ 200 mA ≤ 150 mA PNP ≥ 5 mA / ≤ 1,5 mA > 11 VDC / < 5 VDC yellow LED FET / plus switching (PNP) 2000 VDC 2,3 A / 2,3 A / 3,3 A 4A yes / peripheral error LPF yes yellow LED via separate AS-i flat cable, black 12 - 30 VDC ≤ 21 mH ≤ 25 mH IP 65 (with EPDM cable) -25...+70 °C / -25...+85 °C PBT/PC (UL 94 V-0) according to PELV DIN rail / screws refer to the AS-i brochure 70801 Baumer Electric AG Hummelstrasse 17 Postfach CH-8501 Frauenfeld Drawn: 16.08.04/sli Checked: 18.08.04/phw AS-i + AS-i AS-i - P0 D0 . . . . . D2 P3 + IN 1 + IN 2 + IN 3 + IN 4 0+ 01 EX+ 0+ 02 EX+ EXT+ EXT - 0+ 03 EX+ 0+ 04 EX+ general port assignment: D0, D1, D2 P0, P1, P2, P3 output input possible conductor cross-sections: sensor terminals: 0,08...2,5 mm2, actuator terminals: 0,08...2,5 mm2 max. outer cable diameter: ø 2,8...6 mm diagnosis ASI Error (green) (red) Status Description POWER OFF Address = 0 no data exchange no AS-i power Address = 0 Watchdog activated, Address = 0 ok - Sensor supply overload - Sensor supply shorted outputs: - overload / shorted ok external RESET, overload peripheral error LED dark LED light LED flashing - A periperal error at the outputs does not activate a master config. error - Break of output cables not monitored Technical specifications subject to change Tel. +41 52 728 11 22 Fax +41 52 728 11 44 Released: 22.08.05/phw Last change: 18.01.06/phw