データシート

For more information, please visit the product page.
date
06/11/2015
page
1 of 7
SERIES: VSK-S25 │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
•
•
up to 25W continuous power
compact board mount design
universal input (85~264 Vac / 100~370 Vdc)
single output from 5~48 Vdc
over voltage, over current, and short circuit protections
UL/cUL safety approvals
efficiency up to 87%
MODEL
VSK-S25-5U
VSK-S25-9U
output
voltage
output
current
output
power
ripple
and noise1
efficiency
(Vdc)
max
(A)
max
(W)
typ
(mVp-p)
typ
(%)
5
4.1
20.5
50
79
9
2.5
22.5
50
81
VSK-S25-12U
12
2.1
25
50
83
VSK-S25-15U
15
1.6
25
50
84
VSK-S25-24U
24
1.1
25
50
85
VSK-S25-48U
48
0.5
25
50
87
Notes:
1. Ripple and noise are measured at 20 MHz BW by “parallel cable” method with 1 uF ceramic and 10 uF electrolytic capacitors on the output.
PART NUMBER KEY
VSK-S25 - XXU
Base Number
Output Voltage
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VSK-S25 │ DESCRIPTION: AC-DC POWER SUPPLY
date 06/11/2015 │ page 2 of 7
INPUT
parameter
conditions/description
min
voltage
frequency
max
units
85
100
typ
264
370
Vac
Vdc
47
63
Hz
600
340
mA
mA
current
at 115 Vac
at 230 Vac
inrush current
at 115 Vac
at 230 Vac
16
30
A
A
leakage current
at 230 Vac, 50 Hz (RMS)
0.1
mA
input fuse
3.15 A/250 V, slow-blow type (external)
OUTPUT
parameter
conditions/description
capacitive load
5 Vdc output model
9 Vdc output model
12 Vdc output model
15 Vdc output model
24 Vdc output model
48 Vdc output model
line regulation
at full load
load regulation
at 10~100% load
min
voltage set accuracy
adjustability
hold-up time
at 115 Vac
at 230 Vac
switching frequency
temperature coefficient
typ
max
units
12,000
5,600
5,400
2,400
1,400
800
μF
μF
μF
μF
μF
μF
±0.5
%
±1
%
±2
%
±10
%
15
80
ms
ms
65
kHz
±0.02
%/°C
PROTECTIONS
parameter
conditions/description
min
over current protection
auto restart
110
short circuit protection
continuous, auto restart
over voltage protection
5 Vdc output model
9 Vdc output model
12 Vdc output model
15 Vdc output model
24 Vdc output model
48 Vdc output model
typ
max
units
%
7.5
12
20
20
30
60
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
max
units
SAFETY & COMPLIANCE
parameter
conditions/description
isolation voltage
input to output for 1 minute
input to ground for 1 minute
safety approvals
UL60950-1, CE
safety class
class I
conducted emissions
CISPR22/EN55022, Class B
radiated emissions
CISPR22/EN55022, Class B
ESD
IEC/EN61000-4-2 Class B, contact ±6 kV/air ±8 kV
radiated immunity
IEC/EN61000-4-3 Class A, 10V/m
EFT/burst
min
typ
3,000
2,000
IEC/EN61000-4-4 Class B, ±2 kV
IEC/EN61000-4-4 Class B, ±4 kV (external circuit required, see figure 2)
cui.com
Vac
Vac
For more information, please visit the product page.
CUI Inc │ SERIES: VSK-S25 │ DESCRIPTION: AC-DC POWER SUPPLY
date 06/11/2015 │ page 3 of 7
SAFETY & COMPLIANCE (CONTINUED)
parameter
conditions/description
surge
IEC/EN61000-4-5 Class B, ±1 kV/±2 kV
IEC/EN61000-4-5 Class B, ±2 kV/±4 kV (external circuit required, see figure 2)
min
typ
max
conducted immunity
IEC/EN61000-4-6 Class A, 10 Vr.m.s
PFM
IEC/EN61000-4-8 Class A, 10 A/m
voltage dips & interruptions
IEC/EN61000-4-11 Class B, 0%-70%
MTBF
as per MIL-HDBK-217F at 25°C
RoHS
2011/65/EU
units
300,000
hrs
ENVIRONMENTAL
parameter
conditions/description
min
operating temperature
see derating curves
storage temperature
storage humidity
typ
max
units
-40
70
°C
-40
105
°C
95
%
non-condensing
DERATING CURVES
60
Safe operating area
40
20
~
~
100
75
60
Safe operating area
40
70
Ambient Temperature (°C)
Safe operating area
40
20
~
~
50
-10
75
60
85
95 100 105
115
125
235 240 245
~
~
20
~
~
-40
load vs. input voltage (Vdc)
(at 25°C)
Load (%)
~
~
100
80
Load (%)
Load (%)
100
load vs. input voltage (Vac)
(at 25°C)
~
~
load vs. ambient temperature
(at 100~240 Vac)
255
264
100
120
Input Voltage (Vac)
340
370
Input Voltage (Vdc)
SOLDERABILITY
parameter
conditions/description
min
typ
max
units
hand soldering
for 3~5 seconds
350
360
370
°C
wave soldering
for 5~10 seconds (see wave soldering profile)
255
260
265
°C
Peak Temp. 260°C Max.
Wave Soldering Time
4 Sec. Max.
250
Temperature (°C)
200
10 Sec. Max.
150
100
50
0
Time (sec.)
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VSK-S25 │ DESCRIPTION: AC-DC POWER SUPPLY
date 06/11/2015 │ page 4 of 7
MECHANICAL
parameter
conditions/description
dimensions
70.0 x 48.0 x 23.5 (2.756 x 1.889 x 0.925 inch)
min
case material
UL94V-0
typ
max
units
mm
weight
120
cooling
g
convection cooling
MECHANICAL DRAWING
units: mm[inches]
tolerance: ±0.50[±0.020]
pin diameter: Ø1.00[0.039]±0.10[±0.004]
70.0 2.756
PIN CONNECTIONS
PIN
FUNCTION
1
23.5 0.925
GND
2
AC(N)
3
AC(L)
4
TRIM
5
-Vo
6
+Vo
6.0 0.236
(TYP)
FRONT VIEW
Ø1.50[Ø0.059]
4.0 0.157
1
4
5
62.0 2.441
3
6
20.0 0.787
48.0 1.889
2
2
23.0 0.905
5
6
4
1
3
Grid size: 2.54 x 2.54
TOP VIEW
PCB LAYOUT
BOTTOM VIEW
cui.com
5.75 0.226
4.0 0.157
(2 PLCS)
For more information, please visit the product page.
CUI Inc │ SERIES: VSK-S25 │ DESCRIPTION: AC-DC POWER SUPPLY
date 06/11/2015 │ page 5 of 7
TYPICAL APPLICATION CIRCUIT
Figure 1
AC (L)
FU S E
AC(L)
C1
+Vo
C2
T VS
AC D C
MO V 1
LO AD
AC(N)
AC (N)
-Vo
Table 1
Recommended External Circuit Components
MODEL
FUSE
MOV1
C1
C2
TVS
VSK-S25-5U
3.15A/250V
S14K350
1µF
330μF
SMBJ7.0A
VSK-S25-9U
3.15A/250V
S14K350
1µF
330μF
SMBJ12A
VSK-S25-12U
3.15A/250V
S14K350
1µF
330μF
SMBJ20A
VSK-S25-15U
3.15A/250V
S14K350
1µF
330μF
SMBJ20A
VSK-S25-24U
3.15A/250V
S14K350
1µF
120μF
SMBJ30A
VSK-S25-48U
3.15A/250V
S14K350
1µF
68μF
SMBJ64A
EMC RECOMMENDED CIRCUIT
Figure 2
FUSE
LDM
LCM
AC(L)
AC( L)
+Vo
CY1
MOV1
CY2
-Vo
AC(N)
AC(N)
Table 2
Recommended External Circuit Components
Note:
MOV1
S14K350
CY1, CY2
1000pF/400Vac
CX
0.1μF/275Vac
LCM
10mH
LDM
4.7μH/2A
Also refer to Table 1
cui.com
C2
TVS1
+
ACDC
CX
C1
RL
For more information, please visit the product page.
CUI Inc │ SERIES: VSK-S25 │ DESCRIPTION: AC-DC POWER SUPPLY
date 06/11/2015 │ page 6 of 7
APPLICATION NOTES
1. Output voltage trimming
Leave open if not used.
Figure 3
Application Circuit for Trim pin (part in broken line is the interior of models)
+ Vo
+Vo
R1
V re f
Formula for Trim Resistor
R3
V re f
aR 2
R2-a
-R3
a=
Vref
R1
Vo’ - Vref
down : R T=
aR 1
R1-a
-R3
a=
Vo’ - Vref
R2
Vref
RT
R1
Trim
up : R T=
R3
R2
RT
R2
0V
0V
Tr im up
Tr im down
Trim
Note:
Table 3
Notes:
Value for R1, R2, R3, and Vref refer to Table 3
RT: Trim Resistor
a: User-defined parameter, no actual meanings
Vo': The trim up/down voltage
Vout
(Vdc)
R1
(kΩ)
R2
(kΩ)
R3
(kΩ)
Vref
(V)
5
3.3
3.3
1
2.5
9
7.5
2.87
1
2.5
12
3.83
1
1
2.5
15
7.5
1.5
1
2.5
24
8.66
1
1
2.5
48
68
3.73
1
2.5
1. Output filtering capacitor C2 is an electrolytic capacitor, It is recommended to use high frequency and low impedance electrolytic capacitors. For capacitance and current of capacitor please refer to manufacture’s datasheet. Voltage derating of capacitor should be 80% or above. C1 is used to filter high frequency noise. TVS is recommended component to protect post-circuits (when converter fails).
2. All specifications measured at Ta=25C, humidity <75%, nominal input voltage, and rated output load, unless otherwise specified.
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VSK-S25 │ DESCRIPTION: AC-DC POWER SUPPLY
date 06/11/2015 │ page 7 of 7
REVISION HISTORY
rev.
description
date
1.0
initial release
07/26/2011
1.01
new template applied
03/07/2012
1.02
V-Infinity branding removed
08/21/2012
1.03
spec. update
11/05/2012
1.04
updated spec
01/08/2014
1.05
updated operating and storage temperatures, updated spec
02/25/2015
1.06
updated spec
06/11/2015
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.