vsk s1

For more information, please visit the product page.
date
10/26/2015
page
1 of 5
SERIES: VSK-S1 │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
•
•
up to 1 W continuous power
compact board mount design
universal input (85~305 Vac / 120~430 Vdc)
single output from 3.3~24 Vdc
over current and short circuit protection
UL/cUL and CE safety approvals
efficiency up to 75%
MODEL
output
voltage
output
current
output
power
ripple
and noise1
efficiency
(Vdc)
max
(mA)
max
(W)
max
(mVp-p)
typ
(%)
3.3
300
1
200
63
VSK-S1-5U
5
200
1
200
68
VSK-S1-9U
9
111
1
200
72
VSK-S1-12U
12
83
1
200
73
VSK-S1-15U
15
67
1
200
74
VSK-S1-24U
24
42
1
200
75
VSK-S1-3R3U
Notes:
1. At full load 20 MHz bandwidth oscilloscope, see Test Configuration section.
PART NUMBER KEY
VSK-S1 - XX U
Base Number
Output Voltage
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VSK-S1 │ DESCRIPTION: AC-DC POWER SUPPLY
date 10/26/2015 │ page 2 of 5
INPUT
parameter
conditions/description
min
voltage
frequency
current
at 115 Vac
at 230 Vac
inrush current
at 115 Vac
at 230 Vac
max
units
85
120
typ
305
430
Vac
Vdc
47
63
Hz
37
21
mA
mA
7
14
leakage current
no load power consumption
A
A
0.15
mA
0.2
W
max
units
4,000
2,200
1,000
680
μF
μF
μF
μF
OUTPUT
parameter
conditions/description
min
typ
maximum capacitive load
3.3 and 5 Vdc output models
9 and 12 Vdc output models
15 Vdc output model
24 Vdc output model
line regulation
at full load
±2
%
load regulation
at 10 ~ 100% load
±5
%
voltage accuracy
3.3 Vdc model
all other models
±6
±5
%
%
switching frequency
100
kHz
max
units
PROTECTIONS
parameter
conditions/description
min
over current protection
auto restart
110
short circuit protection
continuous, auto restart
typ
%
SAFETY & COMPLIANCE
parameter
conditions/description
min
typ
isolation voltage
input to output for 1 minute
safety approvals
UL 60950-1
safety class
class II
conducted/radiated emissions
CISPR22/EN55022 Class B
ESD
IEC/EN61000-4-2 class B, contact ±4kV, air ±8kV
radiated immunity
IEC/EN61000-4-3 class A, 10V/m
EFT/burst
IEC/EN61000-4-4 class B, ±2kV (external circuit required, see figure 3)
surge
IEC/EN61000-4-5 class B, ±2kV (external circuit required, see figure 3)
conducted immunity
IEC/EN61000-4-6 class A, 10 Vr.m.s
PFM
IEC/EN61000-4-8 class A, 10 A/m
voltage dips & interruptions
IEC/EN61000-4-11 class B, 0%-70%
MTBF
as per MIL-HDBK-217F, 25°C
RoHS
2011/65/EU
max
3,000
units
Vac
300,000
hours
ENVIRONMENTAL
parameter
conditions/description
min
max
units
operating temperature
see derating curves
-25
70
°C
-25
storage temperature
typ
85
°C
operating humidity
non-condensing
90
%
storage humidity
non-condensing
95
%
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VSK-S1 │ DESCRIPTION: AC-DC POWER SUPPLY
date 10/26/2015 │ page 3 of 5
DERATING/EFFICIENCY CURVES
output power vs. ambient temperature
output power vs. input voltage
(25°C)
(85~305 Vac; 120~430 Vdc)
60
50
40
20
~
~
~
~
100
80
Load (%)
Load (%)
100
80
60
40
-25
-10
55
~
~
~
~
20
70
85
120
Ambient Temperature (°C)
305
430
Input Voltage (Vac/Vdc)
efficiency vs. output power
(Vin=230 Vac)
efficiency vs. input voltage
(full load)
90
90
80
85
VSK-S1-24U
VSK-S1-12U
VSK-S1-5U
70
Efficiency (%)
Efficiency (%)
100
140
60
50
40
30
20
80
75
VSK-S1-24U
VSK-S1-12U
VSK-S1-5U
70
65
60
55
10
50
10
20
30
40
50
60
70
80
90
100
85
120
Load (%)
220
240
264
305
Input Voltage (Vac)
MECHANICAL
parameter
conditions/description
dimensions
33.70 x 22.20 x 18.00 (1.327 x 0.874 x 0.708 inch)
min
case material
UL94V-0
typ
max
mm
weight
20
g
MECHANICAL DRAWING
>@
units: mm [inches]
tolerance: ±0.50 [±0.020]
pin section tolerance: ±0.10 mm [±0.004]
-Vo
4
+Vo
>@
Fro nt vie w
∅1.10[0.43]
>@
>@
1
2
4
1
4
2
3
>@
3
>@
Recommended PCB Layout
Top View
Bo tt o m vie w
cui.com
>@
3
>@
AC(L)
>@
AC(N)
2
>@
1
>@
FUNCTION
>@
PIN
>@
PIN CONNECTIONS
units
For more information, please visit the product page.
CUI Inc │ SERIES: VSK-S1 │ DESCRIPTION: AC-DC POWER SUPPLY
date 10/26/2015 │ page 4 of 5
TEST CONFIGURATION
AC(L)
Copper sheet
FUSE
AC(L)
Figure 1
+Vo
AC/DC
AC( N)
AC(N)
C2
C1
Connect
Oscillograph Probe
Load
-Vo
Table 1
12. 7m m
25. 4m m
25. 4m m
External components
C1
1μF ceramic
C2
10μF electrolytic
TYPICAL APPLICATION CIRCUIT
AC (L)
NTC
FUSE
CX
M OV
Figure 2
AC (N)
AC (L)
+Vo
C1
C2
TVS
+
AC / DC
RL
AC (N)
-Vo
Table 2
Recommended external circuit components
Model
FUSE
MOV
NTC
R1
CY3, CY4
CX
LCM
TVS1
C12
C23
VSK-S1-3R3U
1A/300V, slow blow
S14K350
10D-11
47Ω/3W
2.2nF/400V
0.4μF/305Vac
10 mH
SMBJ7.0A
1μF/50V
220μF
VSK-S1-5U
1A/300V, slow blow
S14K350
10D-11
47Ω/3W
2.2nF/400V
0.1μF/305Vac
10 mH
SMBJ7.0A
1μF/50V
220μF
VSK-S1-9U
1A/300V, slow blow
S14K350
10D-11
47Ω/3W
2.2nF/400V
0.1μF/305Vac
10 mH
SMBJ12A
1μF/50V
120μF
VSK-S1-12U
1A/300V, slow blow
S14K350
10D-11
47Ω/3W
2.2nF/400V
0.1μF/305Vac
10 mH
SMBJ20A
1μF/50V
120μF
VSK-S1-15U
1A/300V, slow blow
S14K350
10D-11
47Ω/3W
2.2nF/400V
0.1μF/305Vac
10 mH
SMBJ20A
1μF/50V
120μF
VSK-S1-24U
1A/300V, slow blow
S14K350
10D-11
47Ω/3W
2.2nF/400V
0.1μF/305Vac
10 mH
SMBJ30A
1μF/50V
68μF
EMC RECOMMENDED CIRCUIT
AC (L)
Figure 3
FUSE
R1
CY3
M OV
CY4
LCM
AC (L)
CX
AC / DC
AC (N)
Notes:
+Vo
AC (N)
C1
C2
+
TVS
RL
-Vo
1. See Table 2 for EMC components.
2. TVS is a recommended component to protect post-circuits if converter fails.
3. C1 is a ceramic capacitor used to filter high frequency noise.
4. C2 is an electrolytic capacitor. We recommend using high frequency and low impedence electrolytic capacitors. For capacitance and current of capacitor please refer to the manufacture’s datasheet. Voltage derating of capacitor should be 80% or above.
5. All specifications are measured at rated input voltage, rated output load, TA=25°C, and humidity < 75% unless otherwise specified.
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VSK-S1 │ DESCRIPTION: AC-DC POWER SUPPLY
date 10/26/2015 │ page 5 of 5
REVISION HISTORY
rev.
description
date
1.0
initial release
06/04/2012
1.01
picture updated
09/06/2012
1.02
updated derating curves and spec
11/12/2013
internal inductor & PCB structure changed
10/26/2015
1.03
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.