VSK-S1-3R3U

For more information, please visit the product page.
date
11/12/2013
page
1 of 5
SERIES: VSK-S1 │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
•
•
up to 1 W continuous power
compact board mount design
universal input (85~305 Vac / 120~430 Vdc)
single output from 3.3~24 V
over current and short circuit protection
UL/cUL and CE safety approvals
efficiency up to 75%
MODEL
output
voltage
output
current
output
power
ripple
and noise1
efficiency
(Vdc)
max
(mA)
max
(W)
max
(mVp-p)
typ
(%)
3.3
300
1
200
63
VSK-S1-5U
5
200
1
200
68
VSK-S1-9U
9
111
1
200
72
VSK-S1-12U
12
83
1
200
73
VSK-S1-15U
15
67
1
200
74
VSK-S1-24U
24
42
1
200
75
VSK-S1-3R3U
Notes:
1. At full load 20 MHz bandwidth oscilloscope, see Test Configuration section.
PART NUMBER KEY
VSK-S1 - XX U
Base Number
Output Voltage
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VSK-S1 │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/12/2013 │ page 2 of 5
INPUT
parameter
conditions/description
min
voltage
frequency
max
units
85
120
typ
305
430
Vac
Vdc
47
63
Hz
current
at 115 Vac
at 230 Vac
30
17
mA
mA
inrush current
at 115 Vac
at 230 Vac
5
11
A
A
leakage current
0.15
mA
OUTPUT
parameter
conditions/description
maximum capacitave load
3.3 and 5 V output models
9 and 12 V output models
15 V output model
24 V output model
min
typ
line regulation
max
units
4,000
2,200
1,000
680
μF
μF
μF
μF
±2
%
load regulation
10 ~ 100%
±5
%
voltage accuracy
3.3 V model
all other models
±6
±5
%
%
100
kHz
max
units
switching frequency
PROTECTIONS
parameter
conditions/description
min
over current protection
short circuit protection
typ
110
%
continuous, auto restart
SAFETY & COMPLIANCE
parameter
conditions/description
min
typ
isolation voltage
for 1 minute
safety approvals
UL 60950-1
safety class
class II
conducted emissions
CISPR22/EN55022 Class B
radiated emissions
CISPR22/EN55022 Class B
ESD
IEC/EN61000-4-2 class B, contact ±4kV, air ±8kV
radiated immunity
IEC/EN61000-4-3 class A, 10V/m
EFT/burst
IEC/EN61000-4-4 class B, ±2kV (external circuit required, see figure 3)
surge
IEC/EN61000-4-5 class B, ±2kV (external circuit required, see figure 3)
conducted immunity
IEC/EN61000-4-6 class A, 10 Vr.m.s
PFM
IEC/EN61000-4-8 class A, 10 A/m
voltage dips & interruptions
IEC/EN61000-4-11 class B, 0%-70%
MTBF
25°C
RoHS
2011/65/EU
max
3,000
units
Vac
300,000
hrs
ENVIRONMENTAL
parameter
conditions/description
min
max
units
operating temperature
see derating curve
-25
70
°C
-40
storage temperature
typ
85
°C
operating humidity
non-condensing
90
%
storage humidity
non-condensing
95
%
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VSK-S1 │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/12/2013 │ page 3 of 5
DERATING CURVES
1. output power vs.
ambient temperature
(85~305 Vac)
3. efficiency vs. input voltage
(load=100%)
2. efficiency vs. output power
(Vin=220Vac)
80
75
70
60
40
65
VSK-S1-5U
VSK-S1-9U
60
VSK-S1-12U
VSK-S1-15U
55
VSK-S1-24U
50
20
70
VSK-S1-3R3U
Efficiency (%)
80
Efficiency (%)
Load (%)
80
75
100
-20
0
20
40
55
40
10
70 80
Ambient Temperature (°C)
VSK-S1-9U
VSK-S1-12U
60
VSK-S1-15U
VSK-S1-24U
55
50
45
-25
VSK-S1-3R3U
VSK-S1-5U
65
45
20
30
40
50
60
70
80
90
85
100
120
220
240
264
305
Input Voltage (Vac)
Load (%)
MECHANICAL
parameter
conditions/description
dimensions
33.70 x 22.20 x 18.00 (1.327 x 0.874 x 0.708 inch)
min
case material
UL94V-0
typ
max
units
mm
weight
20
g
MECHANICAL DRAWING
(Fro nt vie w)
>@
>@
units: mm [inches]
tolerance: ±0.5 [±0.02]
pin section tolerance: ±0.10 mm [±0.004]
PIN CONNECTIONS
>@
>@
>@
∅1.10[0.43]
PIN
FUNTION
1
AC(N)
2
AC(L)
3
-Vo
4
+Vo
>@
3
>@
1
3
4
2
>@
cui.com
>@
(Side vie w)
>@
4
>@
1
>@
(Bo tt o m vie w)
>@
>@
2
For more information, please visit the product page.
CUI Inc │ SERIES: VSK-S1 │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/12/2013 │ page 4 of 5
TEST CONFIGURATION
Copper sheet
FUSE
AC(L)
AC(L)
Figure 1
+Vo
AC/DC
AC( N)
AC(N)
C2
C1
Connect
Oscillograph Probe
Load
-Vo
Table 1
12. 7m m
25. 4m m
25. 4m m
External components
C1
1μF ceramic
C2
10μF electrolytic
TYPICAL APPLICATION CIRCUIT
AC (L)
FU S E
N TC
MO V
Figure 2
AC(L)
CX
AC (N)
C1
+Vo
C2
TVS
+
A C /D C
RL
A C (N )
- Vo
Table 2
Recommended external circuit components
Model
FUSE
NTC
MOV
LCM
TVS1
C12
C23
CY3
CY4
CX
VSK-S1-3R3U
1A/300V, slow blow
5D-9
S14K350
10 mH
SMBJ7.0A
1μF/50V
220μF
2.2nF/400V
2.2nF/400V
0.1μF/305Vac
VSK-S1-5U
1A/300V, slow blow
5D-9
S14K350
10 mH
SMBJ7.0A
1μF/50V
220μF
2.2nF/400V
2.2nF/400V
0.1μF/305Vac
VSK-S1-9U
1A/300V, slow blow
5D-9
S14K350
10 mH
SMBJ12A
1μF/50V
120μF
2.2nF/400V
2.2nF/400V
0.1μF/305Vac
VSK-S1-12U
1A/300V, slow blow
5D-9
S14K350
10 mH
SMBJ20A
1μF/50V
120μF
2.2nF/400V
2.2nF/400V
0.1μF/305Vac
VSK-S1-15U
1A/300V, slow blow
5D-9
S14K350
10 mH
SMBJ20A
1μF/50V
120μF
2.2nF/400V
2.2nF/400V
0.1μF/305Vac
VSK-S1-24U
1A/300V, slow blow
5D-9
S14K350
10 mH
SMBJ30A
1μF/50V
68μF
2.2nF/400V
2.2nF/400V
0.1μF/305Vac
EMC RECOMMENDED CIRCUIT
AC(L)
Figure 3
FUSE
NTC
CY3
MO V
CY4
AC(L)
LCM
CX
AC/DC
AC(N)
Notes:
+Vo
AC(N)
C1
C2
+
TVS
RL
-Vo
1. See Table 2 for EMC components.
2. TVS is a recommended component to protect post-circuits if converter fails.
3. C1 is a ceramic capacitor used to filter high frequency noise.
4. C2 is an electrolytic capacitor. We recommend using high frequency and low impedence electrolytic capacitors. For capacitance and current of capacitor please refer to the manufacture’s datasheet. Voltage derating of capacitor should be 80% or above.
5. All specifications are measured at rated input voltage, rated output load, TA=25°C, and humidity < 75% unless otherwise specified.
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VSK-S1 │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/12/2013 │ page 5 of 5
REVISION HISTORY
rev.
description
date
1.0
initial release
06/04/2012
1.01
picture updated
09/06/2012
1.02
updated derating curves and spec
11/12/2013
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.