Si5040 Device Functionality and Datasheet Change Std

Process Change Notice #1002151A
User Registration
Register today to create your account on Silabs.com. Your personalized profile allows you to receive technical document
updates, new product announcements, “how-to” and design documents, product change notices (PCN) and other valuable content
available only to registered users. http://www.silabs.com/profile
PCN Date: 15Feb10
Effective Date: 10May10
Title: Title: Si5040 Device Functionality & Datasheet Change
Originator: Mike Petrowski
Phone: 512-464-9426
Dept: Timing
Customer Contact: Kathy Haggar
Phone: 512-532-5261
Dept: Sales/Customer Service
PCN Type:
Assembly
Discontinuance
Package
Test
Datasheet
Fabrication
Product Revision
Packing
Labeling
Location
Other
Last Order Date: NA
PCN Details
Description of Change:
The following changes are being made to device functionality:
1.) A dynamic modification of receiver (RX) control registers is required when the receive CMU
transitions between locked and unlocked states. In addition, if the transmit CMU is
configured for reference less operation, Reg134[2:0] = 000b, the transmit (TX) control
registers require modification when the transmit CMU transitions between locked and
unlocked states. This dynamic register write procedure improves acquisition performance
and causes no other changes to device performance. The new Si5040 datasheet (Rev 0.86)
documents the dynamic RX & TX register write procedure that is highlighted in the table
below.
Register Modification
Firmware Requirements
RX Register
TX Register
Set Reg77[7:0] = 0Dh.
Set Reg205[7:0] = 0Dh.
When TX LOL transitions “high“
No change
Set Reg226[7:0] = 98h
When TX LOL transitions “low“
No change
Set Reg226[7:0] = 00h
When RX LOL transitions “high“
Set Reg98[7:0] = 98h
No change
When RX LOL transitions “low“
Set Reg98[7:0] = 00h
No change
One time register modification at power up
2.) Transmit CMU mode 3 (Reg134[2:0] = 011b) and mode 7 (Reg134[2:0] = 111b) will no longer
be supported. Please contact Silicon Labs if this change impacts your application. A list of
Silicon Laboratories sales representatives is available at www.silabs.com.
Reason for Change:
Improve lead times and delivery schedules that were negatively impacted when test coverage was
enhanced to address the acquisition performance issue highlighted in the quality notification letter
dated 7-OCT-09.
W7206F1 Process Change Notice Form rev V
The information contained in this document is PROPRIETARY to Silicon Laboratories, Inc. and shall not be reproduced or used in
part or whole without Silicon Laboratories’ written consent. The document is uncontrolled if printed or electronically saved. Pg 1
Process Change Notice #1002151A
Impact on Form, Fit, Function, Quality, Reliability:
Si5040 functionality has changed as described above and documented in Rev 0.86 of the datasheet.
There is no impact to the part form, fit, quality, or reliability.
Product Identification:
See Appendix A for affected part numbers.
Last Date of Unchanged Product: 10May10
Qualification Samples:
Available now. Please contact your local Silicon Laboratories sales representative to request
samples. A list of Silicon Laboratories sales representatives is available at www.silabs.com.
Customer Early Acceptance Sign Off:
Customers may approve early PCN acceptance by completing the information below:
Early Acceptance Date:
Name:
Company:
Email your early Acceptance approval to: [email protected]
Qualification Data: N/A
Appendix A: Affected Part Numbers
Current OPN
Si5040-D-GM
Si5040-D-GMR
W7206F1 Process Change Notice Form rev V
The information contained in this document is PROPRIETARY to Silicon Laboratories, Inc. and shall not be reproduced or used in
part or whole without Silicon Laboratories’ written consent. The document is uncontrolled if printed or electronically saved. Pg 2