Technical Specification IQ32xxxQTXxxx 9-75V 100V Continuous Input Transient Input 1.8-48V 86W 2250V dc Quarter-brick Outputs Max Power Isolation DC-DC Converter The InQor quarter-brick converter series is composed of next-generation, board-mountable, isolated, fixed switching frequency dc-dc converters that use synchronous rectification to achieve extremely high power conversion efficiency. Each module is supplied completely encased to provide protection from the harsh environments seen in many industrial and transportation applications. IQ ERT S-G 7A High efficiency, 85% at full rated load current Delivers full power with minimal derating - no heatsink required Operating input voltage range: 9-75V Fixed frequency switching provides predictable EMI No minimum load requirement Protection Features Mechanical Features • • • • R 17N Q T C ER @1 ONV DC C 5.0V OUT DCV IN 9-75 Operational Features • • • • • 50 320 Industry standard Quarter-brick pin-out configuration Size: 2.386" x 1.536" x 0.500" (60.60 x 39.01 x 12.70 mm) Total weight: 3.0 oz (85 g) Flanged baseplate version available • • • • • Input under-voltage lockout Output current limit and short circuit protection Active back bias limit Output over-voltage protection Thermal shutdown Control Features • On/Off control referenced to input side • Remote sense for the output voltage • Output voltage trim range of -20%, +10% Safety Features • • • • UL 60950-1/R:2011-12 Basic Insulation CAN/CSA-C22.2 No. 60950-1/A1:2011 EN 60950-1/A12:2011 RoHS compliant (see last page) Product # IQ32xxxQTXxxx Phone 1-888-567-9596 CONTENTS Page No. Family Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 aaVout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . . 4 aaVout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . . 6 5.0Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . . 8 aaVout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . 10 12Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . 12 aaVout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . 14 24Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . 16 aaVout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . 18 aaVout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . 20 Application Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Standards & Qualification Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Standard Mechanical Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Flanged Mechanical Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 www.synqor.com Doc.# 005-0005527 Rev. B 11/12/13 Page 1 Technical Specification IQ32xxxQTXxxx IQ32-QT FAMILY ELECTRICAL CHARACTERISTICS (all output voltages) Ta = 25 °C, airflow rate = 300 LFM, Vin = 32V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. ABSOLUTE MAXIMUM RATINGS Input Voltage Non-Operating -1 Operating Operating Transient Protection Insulation Voltage Input to Output Input to Base-Plate Output to Base-Plate Operating Temperature -40 Storage Temperature -45 Voltage at ON/OFF input pin -2 INPUT CHARACTERISTICS Operating Input Voltage Range 9 Input Under-Voltage Lockout Turn-On Voltage Threshold 9.0 Turn-Off Voltage Threshold 8.1 Lockout Voltage Hysteresis Input Over-Voltage Shutdown Recommended External Input Capacitance Input Filter Component Values (L\C) DYNAMIC CHARACTERISTICS Turn-On Transient Turn-On Time Start-Up Inhibit Time 200 Output Voltage Overshoot ISOLATION CHARACTERISTICS Isolation Voltage (dielectric strength) Isolation Resistance 30 Isolation Capacitance (input to output) TEMPERATURE LIMITS FOR POWER DERATING CURVES Semiconductor Junction Temperature Board Temperature Transformer Temperature Maximum Baseplate Temperature, Tb FEATURE CHARACTERISTICS Switching Frequency 260 ON/OFF Control Off-State Voltage 2.4 On-State Voltage -2 ON/OFF Control Pull-Up Voltage Pull-Up Resistance Over-Temperature Shutdown OTP Trip Point Over-Temperature Shutdown Restart Hysteresis RELIABILITY CHARACTERISTICS Calculated MTBF (Telcordia) TR-NWT-000332 Calculated MTBF (MIL-217) MIL-HDBK-217F Field Demonstrated MTBF Product # IQ32xxxQTXxxx Phone 1-888-567-9596 Max. Units Notes & Conditions 100 75 100 V V V 2250 2250 2250 100 125 18 V dc V dc V dc °C °C V 32 75 V 9.5 8.5 1.0 330.0 0.47\6.6 10.0 8.9 V V V V µF µH\µF Not Available Typical ESR 0.1-0.2 Ω Internal values; see Figure D ms ms % Full load, Vout=90% nom. Figure E Maximum Output Capacitance 9 230 0 250 Continuous Continuous Baseplate temperature See Absolute Maximum Ratings MΩ pF 1000 275 125 125 125 100 °C °C °C °C Package rated to 150 °C UL rated max operating temp 130 °C 290 kHz Isolation stage switching freq. is half this 18 0.8 V Application notes Figures A & B 5 50 125 10 1.49 1.31 www.synqor.com V kΩ °C °C Average PCB Temperature 106 Hrs. Tb = 70°C 106 Hrs. Tb = 70°C 106 Hrs. See our website for details Doc.# 005-0005527 Rev. B 11/12/13 Page 2 Technical Specification IQ32xxxQTXxxx Family Figures (all output voltages) 120 Typical Current Limit Inception Point Nominal Vout Output Voltage (%) 100 80 Typical Output Voltage at Shutdown 60 40 Vin min Vin nom 20 Vin max 0 0 Common Figure 1: Typical startup waveform. Input voltage pre-applied, ON/ OFF Pin on Ch 2. 20 30 40 50 60 70 80 90 100 110 120 130 140 150 Load Current (%) Common Figure 2: Output voltage vs. load current showing typical current limit curves and converter shutdown points. 100,000.0 100,000.0 1.8 V 10,000.0 3.3 V 5V 7V 12 V 15 V Trim Resistance (kOhms) Trim Resistance (kOhms) 10 1,000.0 100.0 10.0 24 V 30 V 48 V 10,000.0 1,000.0 100.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0 Increase in Vout (%) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Increase in Vout (%) Common Figure 3: Trim graph for trim-up 1.8 to 12 V outputs. Common Figure 4: Trim graph for trim-up 15 to 48 V outputs. 10,000.0 Trim Resistance (kOhms) All voltages 1,000.0 100.0 10.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Decrease in Vout (%) Common Figure 5: Trim graph for trim down. Product # IQ32xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005527 Rev. B 11/12/13 Page 3 Input:9-75V Output:1.8V Current:35A Part No.:IQ32018QTx35 Technical Specification IQ32018QTx35 ELECTRICAL CHARACTERISTICS (1.8 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 32V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. Units Notes & Conditions INPUT CHARACTERISTICS Maximum Input Current 12.0 A Vin min; trim up; in current limit No-Load Input Current 200 250 mA Disabled Input Current 4 6 mA Response to Input Transient 0.2 V See Figure 6 Input Terminal Ripple Current 100 mA RMS Recommended Input Fuse 20 A Fast acting external fuse recommended OUTPUT CHARACTERISTICS Output Voltage Set Point 1.782 1.800 1.818 V Output Voltage Regulation Over Line ±0.1 ±0.3 % Over Load ±0.1 ±0.3 % Over Temperature -27 27 mV Total Output Voltage Range 1.755 1.845 V Over sample, line, load, temperature & life Output Voltage Ripple and Noise 20 MHz bandwidth; see Note 1 Peak-to-Peak 100 200 mV Full load RMS 10 20 mV Full load A Operating Output Current Range 0 35 Subject to thermal derating Output DC Current-Limit Inception 38.5 42.0 45.5 A Output voltage 10% Low Output DC Current-Limit Shutdown Voltage 0.9 V Back-Drive Current Limit while Enabled 0.8 A Negative current drawn from output Back-Drive Current Limit while Disabled 15 mA Negative current drawn from output Maximum Output Capacitance 15,000 µF Vout nominal at full load (resistive load) Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) 90 mV 50% to 75% to 50% Iout max Settling Time 500 µs To within 1% Vout nom Output Voltage Trim Range -20 10 % Across Pins 8&4; Common Figures 3-5; see Note 2 Output Voltage Remote Sense Range 10 % Across Pins 8&4 Output Over-Voltage Protection 2.1 2.2 2.3 V Over full temp range EFFICIENCY 100% Load 77 % See Figure 1 for efficiency curve 50% Load 79 % See Figure 1 for efficiency curve Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Note 2: Trim-up range is limited below 10% at lower line and full load. Contact SynQor applications support for more detail (email: [email protected]) Product # IQ32xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005527 Rev. B 11/12/13 Page 4 Input:9-75V Output:1.8V Current:35A Part No.:IQ32018QTx35 Technical Specification 20 100 95 16 Power Dissipation (W) Efficiency (%) 90 85 80 75 70 9Vin 9Vin 32 Vin 75 Vin 75 Vin 0 60 0 5 10 15 20 Load Current (A) 25 30 0 35 Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 5 10 15 20 Load Current (A) 25 30 35 Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 40 40 35 35 30 30 25 25 Iout (A) Iout (A) 8 4 32 Vin 65 12 20 20 15 15 400 LFM (2.0 m/s) 10 200 LFM (1.0 m/s) 5 400 LFM (2.0 m/s) 10 300 LFM (1.5 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 5 100 LFM (0.5 m/s) 100 LFM (0.5 m/s) 0 0 25 40 55 Ambient Air Temperature (°C) 70 25 85 40 55 Ambient Air Temperature (°C) 70 85 Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.6A/µs). Load cap: 15µF tantalum cap and 1µF ceramic cap. Ch 1: Vout, Ch 2: Iout (10A/div). Figure 6: Output voltage response to step-change in input voltage (nominal to maximum), at full load current. Load cap: 15µF tantalum capacitor and 1uF ceramic cap. Ch 1: Vout, Ch 2: Vin. Product # IQ32xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005527 Rev. B 11/12/13 Page 5 Input:9-75V Output:3.3V Current:25A Part No.:IQ32033QTx25 Technical Specification IQ32033QTx25 ELECTRICAL CHARACTERISTICS (3.3 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 32V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. Units Notes & Conditions INPUT CHARACTERISTICS Maximum Input Current No-Load Input Current Disabled Input Current 14.1 A 200 250 mA 4 6 mA Response to Input Transient 0.19 V Input Terminal Ripple Current 100 mA Recommended Input Fuse 20 A 3.300 3.333 V ±0.1 ±0.3 % ±0.1 Vin min; trim up; in current limit See Figure 6 RMS Fast acting external fuse recommended OUTPUT CHARACTERISTICS Output Voltage Set Point 3.267 Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range ±0.3 % -50 50 mV 3.217 3.383 V 100 200 mV Full load 10 20 mV Full load 25 A Subject to thermal derating 32.5 A Output voltage 10% Low Output Voltage Ripple and Noise Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1 Peak-to-Peak RMS Operating Output Current Range 0 Output DC Current-Limit Inception 27.5 Output DC Current-Limit Shutdown Voltage 30.0 1.5 V Back-Drive Current Limit while Enabled 1 A Negative current drawn from output Back-Drive Current Limit while Disabled 15 mA Negative current drawn from output µF Vout nominal at full load (resistive load) Maximum Output Capacitance 10,000 Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) 125 mV 50% to 75% to 50% Iout max Settling Time 500 µs To within 1% Vout nom 10 % Across Pins 8&4; Common Figures 3-5 10 % Across Pins 8&4 4.2 V Over full temp range % See Figure 1 for efficiency curve Output Voltage Trim Range -20 Output Voltage Remote Sense Range Output Over-Voltage Protection 3.9 4.0 EFFICIENCY 100% Load 86 50% Load 87 % See Figure 1 for efficiency curve Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Product # IQ32xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005527 Rev. B 11/12/13 Page 6 Input:9-75V Output:3.3V Current:25A Part No.:IQ32033QTx25 Technical Specification 20 100 95 16 Power Dissipation (W) Efficiency (%) 90 85 80 75 70 9Vin 9Vin 32 Vin 75 Vin 75 Vin 60 0 0 5 10 15 20 Load Current (A) 25 Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 0 30 30 25 25 20 20 15 10 10 15 20 Load Current (A) 25 15 10 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 5 5 Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. Iout (A) Iout (A) 8 4 32 Vin 65 12 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 5 200 LFM (1.0 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) 100 LFM (0.5 m/s) 0 0 25 40 55 Ambient Air Temperature (°C) 70 25 85 40 55 Ambient Air Temperature (°C) 70 85 Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.6A/µs). Load cap: 15µF tantalum cap and 1µF ceramic cap. Ch 1: Vout, Ch 2: Iout (10A/div). Figure 6: Output voltage response to step-change in input voltage (nominal to maximum), at full load current. Load cap: 15µF tantalum capacitor and 1uF ceramic cap. Ch 1: Vout, Ch 2: Vin. Product # IQ32xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005527 Rev. B 11/12/13 Page 7 Input:9-75V Output:5V Current:17A Part No.:IQ32050QTx17 Technical Specification IQ32050QTx17 ELECTRICAL CHARACTERISTICS (5.0 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 32V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. Units Notes & Conditions INPUT CHARACTERISTICS Maximum Input Current No-Load Input Current Disabled Input Current 14.8 A 200 250 mA 4 6 mA Response to Input Transient 0.24 V Input Terminal Ripple Current 100 mA Recommended Input Fuse 20 A 5.000 5.050 V ±0.1 ±0.3 % ±0.1 Vin min; trim up; in current limit See Figure 6 RMS Fast acting external fuse recommended OUTPUT CHARACTERISTICS Output Voltage Set Point 4.950 Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range ±0.3 % -75 75 mV 4.875 5.125 V 100 200 mV Full load 10 20 mV Full load 17 A Subject to thermal derating 22.1 A Output voltage 10% Low Output Voltage Ripple and Noise Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1 Peak-to-Peak RMS Operating Output Current Range 0 Output DC Current-Limit Inception 18.7 20.4 Output DC Current-Limit Shutdown Voltage 2.5 V Back-Drive Current Limit while Enabled 0.6 A Negative current drawn from output Back-Drive Current Limit while Disabled 15 mA Negative current drawn from output µF Vout nominal at full load (resistive load) 50% to 75% to 50% Iout max Maximum Output Capacitance 8,000 Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) 200 mV Settling Time 500 µs Output Voltage Trim Range -20 Output Voltage Remote Sense Range Output Over-Voltage Protection 5.9 6.1 To within 1% Vout nom 10 % Across Pins 8&4; Common Figures 3-5; see Note 2 10 % Across Pins 8&4 6.4 V Over full temp range % See Figure 1 for efficiency curve EFFICIENCY 100% Load 84 50% Load 85 % See Figure 1 for efficiency curve Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Note 2: Trim-up range is limited below 10% at lower line and full load. Contact SynQor applications support for more detail (email: [email protected]) Product # IQ32xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005527 Rev. B 11/12/13 Page 8 Input:9-75V Output:5V Current:17A Part No.:IQ32050QTx17 Technical Specification 20 100 95 16 Power Dissipation (W) Efficiency (%) 90 85 80 75 70 9Vin 9Vin 32 Vin 75 Vin 75 Vin 0 60 0.0 1.7 3.4 5.1 6.8 8.5 10.2 Load Current (A) 11.9 13.6 15.3 0.0 17.0 Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 18 18 15 15 12 12 9 6 3.4 5.1 6.8 8.5 10.2 Load Current (A) 11.9 13.6 15.3 17.0 9 6 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 3 1.7 Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. Iout (A) Iout (A) 8 4 32 Vin 65 12 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 3 200 LFM (1.0 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) 100 LFM (0.5 m/s) 0 0 25 40 55 Ambient Air Temperature (°C) 70 25 85 40 55 Ambient Air Temperature (°C) 70 85 Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.6A/µs). Load cap: 15µF tantalum cap and 1µF ceramic cap. Ch 1: Vout, Ch 2: Iout (10A/div). Figure 6: Output voltage response to step-change in input voltage (nominal to maximum), at full load current. Load cap: 15µF tantalum capacitor and 1uF ceramic cap. Ch 1: Vout, Ch 2: Vin. Product # IQ32xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005527 Rev. B 11/12/13 Page 9 Input:9-75V Output:7V Current:12A Part No.:IQ32070QTx12 Technical Specification IQ32070QTx12 ELECTRICAL CHARACTERISTICS (7.0 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 32V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. Units Notes & Conditions INPUT CHARACTERISTICS Maximum Input Current No-Load Input Current Disabled Input Current 14.3 A 200 250 mA 4 6 mA Response to Input Transient 0.35 V Input Terminal Ripple Current 300 mA Recommended Input Fuse 20 A 7.000 7.070 V ±0.1 ±0.3 % ±0.1 Vin min; trim up; in current limit See Figure 6 RMS Fast acting external fuse recommended OUTPUT CHARACTERISTICS Output Voltage Set Point 6.930 Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range ±0.3 % -105 105 mV 6.825 7.175 V 100 200 mV Full load 10 20 mV Full load 12 A Subject to thermal derating 15.6 A Output voltage 10% Low Output Voltage Ripple and Noise Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1 Peak-to-Peak RMS Operating Output Current Range 0 Output DC Current-Limit Inception 13.2 Output DC Current-Limit Shutdown Voltage 14.4 4 V Back-Drive Current Limit while Enabled 0.6 A Negative current drawn from output Back-Drive Current Limit while Disabled 15 mA Negative current drawn from output µF Vout nominal at full load (resistive load) 50% to 75% to 50% Iout max Maximum Output Capacitance 8,000 Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) 300 mV Settling Time 400 µs Output Voltage Trim Range -20 Output Voltage Remote Sense Range Output Over-Voltage Protection 8.2 8.5 To within 1% Vout nom 10 % Across Pins 8&4; Common Figures 3-5 10 % Across Pins 8&4 8.9 V Over full temp range % See Figure 1 for efficiency curve EFFICIENCY 100% Load 86 50% Load 87 % See Figure 1 for efficiency curve Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Product # IQ32xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005527 Rev. B 11/12/13 Page 10 Input:9-75V Output:7V Current:12A Part No.:IQ32070QTx12 Technical Specification 100 18 95 16 14 Power Dissipation (W) Efficiency (%) 90 85 80 75 70 9Vin 32 Vin 65 10 8 6 4 9Vin 32 Vin 2 75 Vin 75 Vin 0 60 0 2 4 6 Load Current (A) 8 10 0 12 Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 12 12 9 9 6 400 LFM (2.0 m/s) 3 2 4 6 Load Current (A) 8 10 12 Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. Iout (A) Iout (A) 12 6 400 LFM (2.0 m/s) 3 300 LFM (1.5 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) 100 LFM (0.5 m/s) 0 0 25 40 55 Ambient Air Temperature (°C) 70 25 85 40 55 Ambient Air Temperature (°C) 70 85 Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.6A/µs). Load cap: 15µF tantalum cap and 1µF ceramic cap. Ch 1: Vout, Ch 2: Iout. Figure 6: Output voltage response to step-change in input voltage (nominal to maximum), at full load current. Load cap: 15µF tantalum capacitor and 1uF ceramic cap. Ch 1: Vout, Ch 2: Vin. Product # IQ32xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005527 Rev. B 11/12/13 Page 11 Input:9-75V Output:12V Current:7A Part No.:IQ32120QTx07 Technical Specification IQ32120QTx07 ELECTRICAL CHARACTERISTICS (12.0 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 32V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. Units Notes & Conditions INPUT CHARACTERISTICS Maximum Input Current No-Load Input Current Disabled Input Current 14.2 A 200 250 mA 4 6 mA Response to Input Transient 0.97 V Input Terminal Ripple Current 100 mA Recommended Input Fuse 20 A 12.00 12.12 V ±0.1 ±0.3 % ±0.1 Vin min; trim up; in current limit See Figure 6 RMS Fast acting external fuse recommended OUTPUT CHARACTERISTICS Output Voltage Set Point 11.88 Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range ±0.3 % -180 180 mV 11.70 12.30 V 100 200 mV Full load 10 20 mV Full load 7 A Subject to thermal derating 9.1 A Output voltage 10% Low Output Voltage Ripple and Noise Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1 Peak-to-Peak RMS Operating Output Current Range 0 Output DC Current-Limit Inception 7.7 Output DC Current-Limit Shutdown Voltage 8.4 6 V Back-Drive Current Limit while Enabled 0.6 A Negative current drawn from output Back-Drive Current Limit while Disabled 15 mA Negative current drawn from output µF Vout nominal at full load (resistive load) 50% to 75% to 50% Iout max Maximum Output Capacitance 1,500 Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) 430 mV Settling Time 200 µs Output Voltage Trim Range -20 Output Voltage Remote Sense Range Output Over-Voltage Protection 14.0 14.6 To within 1% Vout nom 10 % Across Pins 8&4; Common Figures 3-5; see Note 2 10 % Across Pins 8&4 15.2 V Over full temp range % See Figure 1 for efficiency curve EFFICIENCY 100% Load 87 50% Load 85 % See Figure 1 for efficiency curve Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Note 2: Trim-up range is limited below 10% at lower line and full load. Contact SynQor applications support for more detail (email: [email protected]) Product # IQ32xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005527 Rev. B 11/12/13 Page 12 Input:9-75V Output:12V Current:7A Part No.:IQ32120QTx07 Technical Specification 20 100 95 16 Power Dissipation (W) 90 Efficiency (%) 85 80 75 9Vin 70 32 Vin 9Vin 32 Vin 75 Vin 60 0 1 2 3 4 Load Current (A) 5 6 0 7 Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 0 1 2 3 4 Load Current (A) 5 6 7 Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 8 8 7 7 6 6 5 5 Iout (A) Iout (A) 8 4 75 Vin 65 12 4 4 3 3 400 LFM (2.0 m/s) 2 200 LFM (1.0 m/s) 1 400 LFM (2.0 m/s) 2 300 LFM (1.5 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 1 100 LFM (0.5 m/s) 100 LFM (0.5 m/s) 0 0 25 40 55 Ambient Air Temperature (°C) 70 25 85 40 55 Ambient Air Temperature (°C) 70 85 Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.6A/µs). Load cap: 15µF tantalum cap and 1µF ceramic cap. Ch 1: Vout, Ch 2: Iout (2A/div). Figure 6: Output voltage response to step-change in input voltage (nominal to maximum), at full load current. Load cap: 15µF tantalum capacitor and 1uF ceramic cap. Ch 1: Vout, Ch 2: Vin. Product # IQ32xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005527 Rev. B 11/12/13 Page 13 Input:9-75V Output:15V Current:5.5A Part No.:IQ32150QTx06 Technical Specification IQ32150QTx06 ELECTRICAL CHARACTERISTICS (15.0 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 32V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. Units Notes & Conditions INPUT CHARACTERISTICS Maximum Input Current No-Load Input Current Disabled Input Current 14.2 A 200 250 mA 4 6 mA Response to Input Transient 0.72 V Input Terminal Ripple Current 100 mA Recommended Input Fuse 20 A 15.00 15.15 V ±0.1 ±0.3 % ±0.1 Vin min; trim up; in current limit See Figure 6 RMS Fast acting external fuse recommended OUTPUT CHARACTERISTICS Output Voltage Set Point 14.85 Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range ±0.3 % -225 225 mV 14.62 15.38 V 200 mV Full load Full load Output Voltage Ripple and Noise Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1 Peak-to-Peak 100 RMS 10 Operating Output Current Range 0 Output DC Current-Limit Inception 6.1 Output DC Current-Limit Shutdown Voltage 6.6 20 mV 5.5 A Subject to thermal derating 7.2 A Output voltage 10% Low 9 V Back-Drive Current Limit while Enabled 0.4 A Negative current drawn from output Back-Drive Current Limit while Disabled 15 mA Negative current drawn from output µF Vout nominal at full load (resistive load) 50% to 75% to 50% Iout max Maximum Output Capacitance 1,000 Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) 950 mV Settling Time 200 µs Output Voltage Trim Range -20 Output Voltage Remote Sense Range Output Over-Voltage Protection 17.6 18.3 To within 1% Vout nom 10 % Across Pins 8&4; Common Figures 3-5; see Note 2 10 % Across Pins 8&4 19.1 V Over full temp range % See Figure 1 for efficiency curve EFFICIENCY 100% Load 85 50% Load 86 % See Figure 1 for efficiency curve Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Note 2: Trim-up range is limited below 10% at lower line and full load. Contact SynQor applications support for more detail (email: [email protected]) Product # IQ32xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005527 Rev. B 11/12/13 Page 14 Input:9-75V Output:15V Current:5.5A Part No.:IQ32150QTx06 Technical Specification 20 100 95 16 Power Dissipation (W) Efficiency (%) 90 85 80 75 70 9Vin 12 8 32 Vin 75 Vin 75 Vin 0 60 0.0 1.1 2.2 3.3 4.4 Load Current (A) 0.0 5.5 Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 6 6 5 5 4 4 3 2 2.2 3.3 4.4 Load Current (A) 5.5 3 2 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 1 1.1 Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. Iout (A) Iout (A) 9Vin 4 32 Vin 65 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 1 200 LFM (1.0 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) 100 LFM (0.5 m/s) 0 0 25 40 55 Ambient Air Temperature (°C) 70 25 85 40 55 Ambient Air Temperature (°C) 70 85 Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.6A/µs). Load cap: 15µF tantalum cap and 1µF ceramic cap. Ch 1: Vout, Ch 2: Iout (2A/div). Figure 6: Output voltage response to step-change in input voltage (nominal to maximum), at full load current. Load cap: 15µF tantalum capacitor and 1uF ceramic cap. Ch 1: Vout, Ch 2: Vin. Product # IQ32xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005527 Rev. B 11/12/13 Page 15 Input:9-75V Output:24V Current:3.5A Part No.:IQ32240QTx04 Technical Specification IQ32240QTx04 ELECTRICAL CHARACTERISTICS (24.0 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 32V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. Units Notes & Conditions INPUT CHARACTERISTICS Maximum Input Current No-Load Input Current Disabled Input Current 14.7 A 200 250 mA 4 6 mA Response to Input Transient 1.1 V Input Terminal Ripple Current 100 mA Recommended Input Fuse 20 A 24.00 24.24 V ±0.1 ±0.3 % ±0.1 Vin min; trim up; in current limit See Figure 6 RMS Fast acting external fuse recommended OUTPUT CHARACTERISTICS Output Voltage Set Point 23.76 Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range ±0.3 % -360 360 mV 23.40 24.60 V 200 mV Full load Full load Output Voltage Ripple and Noise Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1 Peak-to-Peak 100 RMS 10 Operating Output Current Range 0 Output DC Current-Limit Inception 3.9 4.2 20 mV 3.5 A Subject to thermal derating 4.6 A Output voltage 10% Low Output DC Current-Limit Shutdown Voltage 16 V Back-Drive Current Limit while Enabled 0.2 A Negative current drawn from output Back-Drive Current Limit while Disabled 15 mA Negative current drawn from output µF Vout nominal at full load (resistive load) 50% to 75% to 50% Iout max Maximum Output Capacitance 400 Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) 1200 mV Settling Time 200 µs Output Voltage Trim Range -20 Output Voltage Remote Sense Range Output Over-Voltage Protection 28.1 29.3 To within 1% Vout nom 10 % Across Pins 8&4; Common Figures 3-5 10 % Across Pins 8&4 30.5 V Over full temp range % See Figure 1 for efficiency curve EFFICIENCY 100% Load 84 50% Load 85 % See Figure 1 for efficiency curve Note 1: Output is terminated with 1 µF ceramic capacitor. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Product # IQ32xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005527 Rev. B 11/12/13 Page 16 Input:9-75V Output:24V Current:3.5A Part No.:IQ32240QTx04 Technical Specification 20 100 95 16 Power Dissipation (W) Efficiency (%) 90 85 80 75 70 9Vin 9Vin 32 Vin 75 Vin 75 Vin 0 60 0.0 0.5 1.0 1.5 2.0 Load Current (A) 2.5 3.0 0.0 3.5 Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 0.5 1.0 1.5 2.0 Load Current (A) 2.5 3.0 3.5 Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 4.0 4.0 3.5 3.5 3.0 3.0 2.5 2.5 Iout (A) Iout (A) 8 4 32 Vin 65 12 2.0 2.0 1.5 1.5 400 LFM (2.0 m/s) 1.0 200 LFM (1.0 m/s) 0.5 400 LFM (2.0 m/s) 1.0 300 LFM (1.5 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 0.5 100 LFM (0.5 m/s) 100 LFM (0.5 m/s) 0.0 0.0 25 40 55 Ambient Air Temperature (°C) 70 25 85 40 55 Ambient Air Temperature (°C) 70 85 Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.6A/µs). Load cap: 1µF ceramic cap. Ch 1: Vout, Ch 2: Iout (1A/div). Figure 6: Output voltage response to step-change in input voltage (nominal to maximum), at full load current. Load cap: 1uF ceramic cap. Ch 1: Vout, Ch 2: Vin. Product # IQ32xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005527 Rev. B 11/12/13 Page 17 Input:9-75V Output:30V Current:2.8A Part No.:IQ32300QTx03 Technical Specification IQ32300QTx03 ELECTRICAL CHARACTERISTICS (30.0 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 32V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. Units Notes & Conditions INPUT CHARACTERISTICS Maximum Input Current No-Load Input Current Disabled Input Current 14.7 A 200 250 mA 4 6 mA Response to Input Transient 1.3 V Input Terminal Ripple Current 100 mA Recommended Input Fuse 20 A 30.00 30.30 V ±0.1 ±0.3 % ±0.1 Vin min; trim up; in current limit See Figure 6 RMS Fast acting external fuse recommended OUTPUT CHARACTERISTICS Output Voltage Set Point 29.70 Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range ±0.3 % -450 450 mV 29.25 30.75 V 200 mV Full load Full load Output Voltage Ripple and Noise Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1 Peak-to-Peak 100 RMS 10 Operating Output Current Range 0 Output DC Current-Limit Inception 3.1 Output DC Current-Limit Shutdown Voltage 3.4 20 mV 2.8 A Subject to thermal derating 3.6 A Output voltage 10% Low 22 V Back-Drive Current Limit while Enabled 0.12 A Negative current drawn from output Back-Drive Current Limit while Disabled 15 mA Negative current drawn from output µF Vout nominal at full load (resistive load) 50% to 75% to 50% Iout max Maximum Output Capacitance 250 Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) 1500 mV Settling Time 200 µs Output Voltage Trim Range -20 Output Voltage Remote Sense Range Output Over-Voltage Protection 35.1 36.6 To within 1% Vout nom 10 % Across Pins 8&4; Common Figures 3-5 10 % Across Pins 8&4 38.1 V Over full temp range % See Figure 1 for efficiency curve EFFICIENCY 100% Load 84 50% Load 85 % See Figure 1 for efficiency curve Note 1: Output is terminated with 1 µF ceramic capacitor. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Product # IQ32xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005527 Rev. B 11/12/13 Page 18 Input:9-75V Output:30V Current:2.8A Part No.:IQ32300QTx03 Technical Specification 100 20 95 16 Power Dissipation (W) Efficiency (%) 90 85 80 75 70 9Vin 9Vin 32 Vin 75 Vin 75 Vin 60 0 0.0 0.4 0.8 1.2 1.6 Load Current (A) 2.0 2.4 2.8 Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 0.0 0.4 0.8 1.2 1.6 Load Current (A) 2.0 2.4 2.8 Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 3.2 3.2 2.8 2.8 2.4 2.4 2.0 2.0 Iout (A) Iout (A) 8 4 32 Vin 65 12 1.6 1.6 1.2 1.2 400 LFM (2.0 m/s) 0.8 200 LFM (1.0 m/s) 0.4 400 LFM (2.0 m/s) 0.8 300 LFM (1.5 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 0.4 100 LFM (0.5 m/s) 100 LFM (0.5 m/s) 0.0 0.0 25 40 55 Ambient Air Temperature (°C) 70 25 85 40 55 Ambient Air Temperature (°C) 70 85 Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.6A/µs). Load cap: 1µF ceramic cap. Ch 1: Vout, Ch 2: Iout (1A/div). Figure 6: Output voltage response to step-change in input voltage (nominal to maximum), at full load current. Load cap: 1uF ceramic cap. Ch 1: Vout, Ch 2: Vin. Product # IQ32xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005527 Rev. B 11/12/13 Page 19 Input:9-75V Output:48V Current:1.8A Part No.:IQ32480QTx02 Technical Specification IQ32480QTx02 ELECTRICAL CHARACTERISTICS (48.0 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 32V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. Units Notes & Conditions INPUT CHARACTERISTICS Maximum Input Current No-Load Input Current Disabled Input Current 15.5 A 200 250 mA 4 6 mA Response to Input Transient 1.2 V Input Terminal Ripple Current 100 mA Recommended Input Fuse 20 A 48.00 48.48 V ±0.1 ±0.3 % ±0.1 Vin min; trim up; in current limit See Figure 6 RMS Fast acting external fuse recommended OUTPUT CHARACTERISTICS Output Voltage Set Point 47.52 Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range ±0.3 % -720 720 mV 46.80 49.20 V 300 mV Full load Full load Output Voltage Ripple and Noise Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1 Peak-to-Peak 150 RMS 20 Operating Output Current Range 0 Output DC Current-Limit Inception 2.0 Output DC Current-Limit Shutdown Voltage 2.2 40 mV 1.8 A Subject to thermal derating 2.3 A Output voltage 10% Low 35 V Back-Drive Current Limit while Enabled 0.08 A Negative current drawn from output Back-Drive Current Limit while Disabled 15 mA Negative current drawn from output µF Vout nominal at full load (resistive load) 50% to 75% to 50% Iout max Maximum Output Capacitance 100 Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) 2000 mV Settling Time 200 µs Output Voltage Trim Range -20 Output Voltage Remote Sense Range Output Over-Voltage Protection 56.2 58.6 To within 1% Vout nom 10 % Across Pins 8&4; Common Figures 3-5 10 % Across Pins 8&4 61.0 V Over full temp range % See Figure 1 for efficiency curve EFFICIENCY 100% Load 82 50% Load 84 % See Figure 1 for efficiency curve Note 1: Output is terminated with 1 µF ceramic capacitor. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Product # IQ32xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005527 Rev. B 11/12/13 Page 20 Input:9-75V Output:48V Current:1.8A Part No.:IQ32480QTx02 Technical Specification 20 100 95 16 Power Dissipation (W) Efficiency (%) 90 85 80 75 70 9Vin 9Vin 32 Vin 75 Vin 75 Vin 0 60 0.0 0.3 0.6 0.9 Load Current (A) 1.2 1.5 0.0 1.8 Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 1.8 1.8 1.5 1.5 1.2 1.2 0.9 0.6 0.6 0.9 Load Current (A) 1.2 1.5 1.8 0.9 0.6 400 LFM (2.0 m/s) 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 300 LFM (1.5 m/s) 0.3 0.3 Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. Iout (A) Iout (A) 8 4 32 Vin 65 12 0.3 200 LFM (1.0 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) 100 LFM (0.5 m/s) 0.0 0.0 25 40 55 Ambient Air Temperature (°C) 70 25 85 40 55 Ambient Air Temperature (°C) 70 85 Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.6A/µs). Load cap: 1µF ceramic cap. Ch 1: Vout, Ch 2: Iout (1A/div). Figure 6: Output voltage response to step-change in input voltage (nominal to maximum), at full load current. Load cap: 1uF ceramic cap. Ch 1: Vout, Ch 2: Vin. Product # IQ32xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005527 Rev. B 11/12/13 Page 21 Technical Specification IQ32xxxQTXxxx Application Section BASIC OPERATION AND FEATURES CONTROL FEATURES This converter series uses a two-stage power topology. The first stage is a buck-converter that output voltage constant over variations in line, temperature. The second stage uses a transformer the functions of input/output isolation and voltage step-down to achieve the output voltage required. REMOTE ON/OFF (Pin 2): The ON/OFF input, Pin 2, permits the user to control when the converter is on or off. This input is referenced to the return terminal of the input bus, Vin(-). The ON/OFF signal is active low (meaning that a low turns the converter on). Figure A details four possible circuits for driving the ON/OFF pin. Figure B is a detailed look of the internal ON/ OFF circuitry. conversion keeps the load, and to provide step-up or Both the first stage and the second stage switch at a fixed frequency for predictable EMI performance. Rectification of the transformer’s output is accomplished with synchronous rectifiers. These devices, which are MOSFETs with a very low on-state resistance, dissipate far less energy than Schottky diodes. This is the primary reason that the converter has such high efficiency, even at very low output voltages and very high output currents. These converters are offered totally encased to withstand harsh environments and thermally demanding applications. Dissipation throughout the converter is so low that it does not require a heatsink for operation in many applications; however, adding a heatsink provides improved thermal derating performance in extreme situations. This series of converters use the industry standard footprint and pin-out configuration. ON/OFF ON/OFF Vin(_) Vin(_) Remote Enable Circuit REMOTE SENSE(+) (Pins 7 and 5): The SENSE(+) inputs correct for voltage drops along the conductors that connect the converter’s output pins to the load. Pin 7 should be connected to Vout(+) and Pin 5 should be connected to Vout(-) at the point on the board where regulation is desired. A remote connection at the load can adjust for a voltage drop only as large as that specified in this datasheet, that is [Vout(+) - Vout(-)] – [Vsense(+) - Vsense(-)] < Sense Range % x Vout Pins 7 and 5 must be connected for proper regulation of the output voltage. If these connections are not made, the converter will deliver an output voltage that is slightly higher than its specified value. Note: the output over-voltage protection circuit senses the voltage across the output (pins 8 and 4) to determine when it should trigger, not the voltage across the converter’s sense leads (pins 7 and 5). Therefore, the resistive drop on the board should be small enough so that output OVP does not trigger, even during load transients. 5V Negative Logic (Permanently Enabled) 5V ON/OFF TTL/ CMOS 50k ON/OFF ON/OFF 50k TTL Vin(_) Vin(_ ) Open Collector Enable Circuit Figure A: Various circuits for driving the ON/OFF pin. Product # IQ32xxxQTXxxx 100pF Vin(-) Direct Logic Drive Phone 1-888-567-9596 Figure B: Internal ON/OFF pin circuitry www.synqor.com Doc.# 005-0005527 Rev. B 11/12/13 Page 22 Technical Specification IQ32xxxQTXxxx Application Section OUTPUT VOLTAGE TRIM (Pin 6): The TRIM input permits the user to adjust the output voltage across the sense leads up or down according to the trim range specifications. To decrease the output voltage, the user should connect a resistor between Pin 6 and Pin 5 (SENSE(-) input). For a desired decrease of the nominal output voltage, the value of the resistor should be Rtrim-down = - 10.22 (511 D% ) (kW) where D% = Vnominal – Vdesired Vnominal x 100% To increase the output voltage, the user should connect a resistor between Pin 6 and Pin 7 (SENSE(+) input). For a desired increase of the nominal output voltage, the value of the resistor should be Rtrim-up = where ( 5.11VOUT x (100+D%) 1.225D% _ 511 _ 10.22 D% ) (kW) Vout = Nominal Output Voltage Trim graphs show the relationship between the trim resistor value and Rtrim-up and Rtrim-down, showing the total range the output voltage can be trimmed up or down. Note: the TRIM feature does not affect the voltage at which the output over-voltage protection circuit is triggered. Trimming the output voltage too high may cause the over-voltage protection circuit to engage, particularly during transients. It is not necessary for the user to add capacitance at the Trim pin. The node is internally bypassed to eliminate noise. Total DC Variation of VOUT: For the converter to meet its full specifications, the maximum variation of the dc value of VOUT, due to both trimming and remote load voltage drops, should not be greater than that specified for the output voltage trim range. Product # IQ32xxxQTXxxx Phone 1-888-567-9596 PROTECTION FEATURES Input Under-Voltage Lockout: The converter is designed to turn off when the input voltage is too low, helping avoid an input system instability problem, described in more detail in the application note titled “Input System Instability” on our website. The lockout circuitry is a comparator with dc hysteresis. When the input voltage is rising, it must exceed the typical TurnOn Voltage Threshold value (listed on the specifications page) before the converter will turn on. Once the converter is on, the input voltage must fall below the typical Turn-Off Voltage Threshold value before the converter will turn off. Output Current Limit: The maximum current limit remains constant as the output voltage drops. However, once the impedance of the load across the output is small enough to make the output voltage drop below the specified Output DC CurrentLimit Shutdown Voltage, the converter turns off. The converter then enters a “hiccup mode” where it repeatedly turns on and off at a 5 Hz (nominal) frequency with a 5% duty cycle until the short circuit condition is removed. This prevents excessive heating of the converter or the load board. Output Over-Voltage Limit: If the voltage across the output pins exceeds the Output Over-Voltage Protection threshold, the converter will immediately stop switching. This prevents damage to the load circuit due to 1) excessive series resistance in output current path from converter output pins to sense point, 2) a release of a short-circuit condition, or 3) a release of a current limit condition. Load capacitance determines exactly how high the output voltage will rise in response to these conditions. After 200 ms the converter will automatically restart. Over-Temperature Shutdown: A temperature sensor on the converter senses the average temperature of the module. The thermal shutdown circuit is designed to turn the converter off when the temperature at the sensed location reaches the Over-Temperature Shutdown value. It will allow the converter to turn on again when the temperature of the sensed location falls by the amount of the Over-Temperature Shutdown Restart Hysteresis value. www.synqor.com Doc.# 005-0005527 Rev. B 11/12/13 Page 23 Technical Specification IQ32xxxQTXxxx Application Section APPLICATION CONSIDERATIONS Input System Instability: This condition can occur because any dc-dc converter appears incrementally as a negative resistance load. A detailed application note titled “Input System Instability” is available on the SynQor website which provides an understanding of why this instability arises, and shows the preferred solution for correcting it. Application Circuits: Figure C provides a typical circuit diagram which details the input filtering and voltage trimming. Vin(+) Vin External Input Filter Electrolytic Capacitor Vout(+) Vsense(+) ON/OFF Trim Vsense(_) Vin(_) Rtrim-up or Rtrim-down Cload Iload Vout(_) Figure C: Typical application circuit (negative logic unit, permanently enabled). Input Filtering and External Capacitance: Figure D provides a diagram showing the internal input filter components. This filter dramatically reduces input terminal ripple current, which otherwise could exceed the rating of an external electrolytic input capacitor. The recommended external input capacitance is specified in the Input Characteristics section on the Electrical Characteristics page. More detailed information is available in the application note titled “EMI Characteristics” on the SynQor website. L Vin(+) C Vin(_) Figure D: Internal Input Filter Diagram (component values listed on the specifications page). Product # IQ32xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005527 Rev. B 11/12/13 Page 24 Technical Specification IQ32xxxQTXxxx Application Section Startup Inhibit Period: The Startup Inhibit Period ensures that the converter will remain off for approximately 200 ms when it is shut down for any reason. When an output short is present, this generates a 5 Hz “hiccup mode,” which prevents the converter from overheating. In all, there are seven ways that the converter can be shut down, initiating a Startup Inhibit Period: • InputUnder-VoltageLockout When the ON/OFF pin goes high after t2, the Startup Inhibit Period has elapsed, and the output turns on within the typical Turn-On Time. Thermal Considerations: The maximum operating base-plate temperature, TB, is 100 ºC. As long as the user’s thermal system keeps TB < 100 ºC, the converter can deliver its full rated power. A power derating curve can be calculated for any heatsink that is attached to the base-plate of the converter. It is only necessary to determine the thermal resistance, RTHBA, of the chosen heatsink between the base-plate and the ambient air for a given airflow rate. This information is usually available from the heatsink vendor. The following formula can the be used to determine the maximum power the converter can dissipate for a given thermal condition if its base-plate is to be no higher than 100 ºC. • InputOver-VoltageLockout • OutputOver-VoltageProtection • OverTemperatureShutdown • CurrentLimit • ShortCircuitProtection • TurnedoffbytheON/OFFinput Figure E shows three turn-on scenarios, where a Startup Inhibit Period is initiated at t0, t1, and t2: Before time t0, when the input voltage is below the UVL threshold, the unit is disabled by the Input Under-Voltage Lockout feature. When the input voltage rises above the UVL threshold, the Input Under-Voltage Lockout is released, and a Startup Inhibit Period is initiated. At the end of this delay, the ON/OFF pin is evaluated, and since it is active, the unit turns on. At time t1, the unit is disabled by the ON/OFF pin, and it cannot be enabled again until the Startup Inhibit Period has elapsed. max Pdiss = 100 ºC - TA RTHBA This value of power dissipation can then be used in conjunction with the data shown in Figure 2 to determine the maximum load current (and power) that the converter can deliver in the given thermal condition. For convenience, power derating curves for an encased converter without a heatsink and with a typical heatsink are provided for each output voltage. Vin Under-Voltage Lockout TurnOn Threshold ON/OFF (neg logic) ON OFF ON OFF ON 9ms Vout (typical turn on time) 230ms (typical start-up inhibit period) t1 t0 200ms 200ms t2 t Figure E: Startup Inhibit Period (turn-on time not to scale) Product # IQ32xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005527 Rev. B 11/12/13 Page 25 Technical Specification IQ32xxxQTXxxx Standards & Qualification Testing Parameter Notes & Conditions STANDARDS COMPLIANCE UL 60950-1/R:2011-12 Basic Insulation CAN/CSA-C22.2 No. 60950-1/A1:2011 EN 60950-1/A12:2011 Certified by TUV Note: An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new releases or download from the SynQor website. Parameter # Units Test Conditions QUALIFICATION TESTING Life Test 32 95% rated Vin and load, units at derating point, 1000 hours Vibration 5 10-55 Hz sweep, 0.060" total excursion, 1 min./sweep, 120 sweeps for 3 axis Mechanical Shock 5 100g minimum, 2 drops in x, y, and z axis Temperature Cycling 10 -40 °C to 100 °C, unit temp. ramp 15 °C/min., 500 cycles Power/Thermal Cycling 5 Toperating = min to max, Vin = min to max, full load, 100 cycles Design Marginality 5 Tmin-10 °C to Tmax+10 °C, 5 °C steps, Vin = min to max, 0-105% load Humidity 5 85 °C, 95% RH, 1000 hours, continuous Vin applied except 5 min/day Solderability 15 pins Altitude 2 MIL-STD-883, method 2003 70,000 feet (21 km), see Note Note: A conductive cooling design is generally needed for high altitude applications because of naturally poor convective cooling at rare atmospheres. Product # IQ32xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005527 Rev. B 11/12/13 Page 26 Technical Specification IQ32xxxQTXxxx Standard Mechanical Diagram 1.536 ±0.020 (39.01 ±0.5) 1. 030 (26.16) 0.600 (15.24) Top View Side View 0.450 (11.43) 0.300 (7.62) 0.150 (3.81) 0.253±0.020 (6.4±0.5) 0.18±0.010 (4.57±0.25) 0.263±0.020 (6.68±0.5) 8 7 6 5 4 2.386 ± 0.020 (60.6± 0.5) 2.00 (50.8) 1.86 (47.2) M3 Threaded Inserts 4 Places See Notes 1 2 3 0.183±.020 (4.65)±0.5 0.500±0.025 (12.7±0.63) Overall Height 0.468±0.020 (11.89±0.5) 0.300 (7.62) 0.600 (15.24) NOTES 1)M3 screws used to bolt unit’s baseplate to other surfaces (such as a heatsink) must not exceed 0.100" (2.54 mm) depth below the surface of the baseplate. PIN DESIGNATIONS Pin Name Function 1 Vin(+) Positive input voltage 2 ON/OFF 3 Vin(–) 2)Applied torque per screw should not exceed 6in-lb. (0.7 Nm). 3)Baseplate flatness tolerance is 0.004" (.10mm) TIR for surface. 4)Pins 1-3, 5-7 are 0.040” (1.02mm) diameter, with 0.080” (2.03mm) diameter standoff shoulders. 5)Pins 4 and 8 are 0.062” (1.57 mm) diameter with 0.100" (2.54 mm) diameter standoff shoulders. 6)All Pins: Material - Copper Alloy- Finish (RoHS 6/6) - Matte Tin over Nickel plate 7)Weight: 3.02 oz. (85.7 g) typical 8)All dimensions in inches (mm) Tolerances: x.xx +/-0.02 in. (x.x +/-0.5mm) x.xxx +/-0.010 in. (x.xx +/-0.25mm) 9)Workmanship: Meets or exceeds IPC-A-610 Class II 10)Recommended pin length is 0.03” (0.76mm) greater than the PCB thickness. Product # IQ32xxxQTXxxx Phone 1-888-567-9596 4 Vout(–) TTL input to turn converter on and off, referenced to Vin(–), with internal pull up. Negative input voltage Negative output voltage 6 SENSE(–) Negative remote sense1 TRIM Output voltage trim2 7 SENSE(+) Positive remote sense3 5 8 Vout(+) Positive output voltage Notes: 1) SENSE(–) should be connected to Vout(–) either remotely or at the converter. 2) Leave TRIM pin open for nominal output voltage. 3) SENSE(+) should be connected to Vout(+) either remotely or at the converter. www.synqor.com Doc.# 005-0005527 Rev. B 11/12/13 Page 27 Technical Specification IQ32xxxQTXxxx Flanged Mechanical Diagram .01 [0.2] OVERALL HEIGHT .500 ±.025 [12.7 ±0.63] 2.200 ±.020 [ 55.88 ±0.5 ] 1.536 ±.020 [ 39.01 ±0.5 ] .18 [ 4.6 ] SEE NOTE 5 R .065 4 [ 1.65 ] TOP VIEW 2.00 [ 50.8 ] 2.07 [ 52.5 ] 1.66 [ 42.2 ] 2.386 [ 60.6 5 6 7 .60 [ 15.2 ] .45 [ 11.4 ] .30 [ 7.6 ] .15 [ 3.8 ] 8 BOTTOM VIEW ±.020 ±0.5 ] 1.01 [25.7] .36 [9.1] 3 1 .70 [ 17.8 ] .183 ±.020 [ 4.65 ±0.5 ] .02 [ 0.6 ] 1.30 [ 33 ] .13 [ 3.2 ] .800 ±.020 [ 20.32 ±0.5 ] 1 BOTTOMSIDE CLEARANCE .010 ±.020 [0.51 0.25] NOTES .30 [ 7.6 ] .60 [ 15.2 ] PIN DESIGNATIONS 1) Applied torque per screw should not exceed 5in-lb. (3in-lb recommended). 2) Baseplate flatness tolerance is 0.01” (.2mm) TIR for surface. 3) Pins 1-3, 5-7 are 0.040” (1.02mm) diameter, with 0.080” (2.03mm) diameter standoff shoulders. 4) Pins 4 and 8 are 0.062” (1.57 mm) diameter with 0.100" (2.54 mm) diameter standoff shoulders. 5) All Pins: Material - Copper Alloy, Finish (RoHS 6/6) - Matte Tin over Nickel plate 6) Total Weight: 3.12 oz (88.5 g) 7) All dimensions in inches (mm) Tolerances: x.xx +/-0.02 in. (x.x +/-0.5mm) x.xxx +/-0.010 in. (x.xx +/-0.25mm) 8) Workmanship: Meets or exceeds IPC-A-610 Class II 9) Recommended pin length is 0.03” (0.76mm) greater than the PCB thickness. 10) A thermal interface material is required to assure proper heat transfer from the flanged baseplate to the cooling surface. Thermal grease may be used, or materials such as Thermalloy’s Grafoil or Bergquist HiFlow and Softflow. Other similar products are available from many heatsink manufacturers. Product # IQ32xxxQTXxxx 2 Phone 1-888-567-9596 www.synqor.com Pin Name Function 1 Vin(+) Positive input voltage 2 ON/OFF 3 Vin(–) 4 Vout(–) TTL input to turn converter on and off, referenced to Vin(–), with internal pull up. Negative input voltage Negative output voltage 6 SENSE(–) Negative remote sense1 TRIM Output voltage trim2 7 SENSE(+) Positive remote sense3 5 8 Vout(+) Positive output voltage Notes: 1) SENSE(–) should be connected to Vout(–) either remotely or at the converter. 2) Leave TRIM pin open for nominal output voltage. 3) SENSE(+) should be connected to Vout(+) either remotely or at the converter. Doc.# 005-0005527 Rev. B 11/12/13 Page 28 Technical Specification IQ32xxxQTXxxx PART NUMBERING SYSTEM ORDERING INFORMATION The part numbering system for SynQor’s dc-dc converters follows the format shown in the example below. The tables below show the valid model numbers and ordering options for converters in this product family. When ordering SynQor converters, please ensure that you use the complete 15 character part number consisting of the 12 character base part number and the additional characters for options. Add “-G” to the model number for 6/6 RoHS compliance. IQ 3 2 0 5 0 Q T C 1 7 N R S - G Options (see Ordering Information) Output Current Thermal Design Performance Level Package Size Output Voltage Input Voltage Product Family The first 12 characters comprise the base part number and the last 3 characters indicate available options. The “-G” suffix indicates 6/6 RoHS compliance. Input Voltage 9-75V 9-75V 9-75V 9-75V 9-75V 9-75V 9-75V 9-75V 9-75V Model Number 6/6 RoHS IQ32018QTw35xyz IQ32033QTw25xyz IQ32050QTw17xyz IQ32070QTw12xyz IQ32120QTw07xyz IQ32150QTw06xyz IQ32240QTw04xyz IQ32300QTw03xyz IQ32480QTw02xyz Max Output Current 35 25 17 12 7.0 5.5 3.5 2.8 1.8 The following options must be included in place of the w x y z spaces in the model numbers listed above. Thermal Design w Options Description Enable Logic Pin Style x y C - Encased V - Encased with Flanged Baseplate Application Notes Output Voltage 1.8 3.3 5.0 7.0 12.0 15.0 24.0 30.0 48.0 N - Negative Feature Set z R - 0.180" S - Standard A variety of application notes and technical white papers can be downloaded in pdf format from our website. RoHS Compliance: The EU led RoHS (Restriction of Hazardous Substances) Directive bans the use of Lead, Cadmium, Hexavalent Chromium, Mercury, Polybrominated Biphenyls (PBB), and Polybrominated Diphenyl Ether (PBDE) in Electrical and Electronic Equipment. This SynQor product is 6/6 RoHS compliant. For more information please refer to SynQor’s RoHS addendum available at our RoHS Compliance / Lead Free Initiative web page or e-mail us at [email protected]. Not all combinations make valid part numbers, please contact SynQor for availability. PATENTS SynQor holds the following U.S. patents, one or more of which apply to each product listed in this document. Additional patent applications may be pending or filed in the future. Contact SynQor for further information and to order: Phone: Toll Free: Fax: E-mail: Web: Address: Product # IQ32xxxQTXxxx 978-849-0600 888-567-9596 978-849-0602 [email protected] www.synqor.com 155 Swanson Road Boxborough, MA 01719 USA Phone 1-888-567-9596 5,999,417 6,222,742 6,545,890 6,577,109 6,594,159 6,731,520 6,894,468 6,896,526 6,927,987 7,050,309 7,072,190 7,085,146 7,119,524 7,269,034 7,272,021 7,272,023 7,558,083 7,564,702 7,765,687 7,787,261 8,023,290 8,149,597 8,493,751 Warranty SynQor offers a two (2) year limited warranty. Complete warranty information is listed on our website or is available upon request from SynQor. Information furnished by SynQor is believed to be accurate and reliable. However, no responsibility is assumed by SynQor for its use, nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of SynQor. www.synqor.com Doc.# 005-0005527 Rev. B 11/12/13 Page 29