Technical Specification IQ64xxxQTXxxx 18-135V 1.8-48V 100W Continuous Input Outputs Max Power 3000Vdc REINFORCED Insulation The InQor quarter-brick converter series is composed of next-generation, board-mountable, isolated (REINFORCED), fixed switching frequency dc-dc converters that use synchronous rectification to achieve extremely high power conversion efficiency. Each module is supplied completely encased to provide protection from the harsh environments seen in many industrial and transportation applications. 18 640 S-G High efficiency, 89% at full rated load current Delivers full power with minimal derating - no heatsink required Operating input voltage range: 18-135V Fixed frequency switching provides predictable EMI No minimum load requirement Protection Features Mechanical Features • • • • DC-DC Converter 36A RT IQ C CONVE .8V OUT @ D 1 DCN V I 5 3 18-1 Operational Features • • • • • R 36N Q T C ER Quarter-brick Industry standard Quarter-brick pin-out configuration Size: 2.386" x 1.536" x 0.500" (60.60 x 39.01 x 12.70 mm) Total weight: 3.0 oz (85 g) Flanged baseplate version available • • • • • Input under-voltage lockout Output current limit and short circuit protection Active back bias limit Output over-voltage protection Thermal shutdown Control Features • On/Off control referenced to input side • Remote sense for the output voltage • Output voltage trim range of -20%, +10% Safety Features Reinforced Insulation • UL 60950-1/R:2011-12 • CAN/CSA-C22.2 No. 60950-1/A1:2011 • EN 60950-1/A12:2011 • CE Marked • RoHS compliant (see last page) Product # IQ64xxxQTXxxx Phone 1-888-567-9596 CONTENTS Page No. Family Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1.8Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . . 4 3.3Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . . 6 5.0Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . . 8 7.0Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . 10 12Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . 12 15Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . 14 24Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . 16 30Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . 18 48Vout Electrical Characteristics & Figures . . . . . . . . . . . . . . . . . . . . . 20 Application Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Standards & Qualification Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Standard Mechanical Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Flanged Mechanical Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 www.synqor.com Doc.# 005-0005096 Rev. E 11/27/13 Page 1 Technical Specification IQ64xxxQTXxxx IQ64-QT Family Electrical Characteristics (all output voltages) Ta = 25 °C, airflow rate = 300 LFM, Vin = 64V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. ABSOLUTE MAXIMUM RATINGS Input Voltage Non-Operating -1 150 Operating 135 Operating Transient Protection Insulation Voltage Input to Output 3000 Input to Base-Plate 3000 Output to Base-Plate 3000 Operating Temperature -40 100 Storage Temperature -45 125 Voltage at ON/OFF input pin -2 18 INPUT CHARACTERISTICS Operating Input Voltage Range 18 64 135 Input Under-Voltage Lockout Turn-On Voltage Threshold 17.1 17.5 17.9 Turn-Off Voltage Threshold 16.1 16.5 16.9 Lockout Voltage Hysteresis 1.0 Input Over-Voltage Shutdown Recommended External Input Capacitance 220uF Input Filter Component Values (L\C) 2\1.2 DYNAMIC CHARACTERISTICS Turn-On Transient Turn-On Time 10 Start-Up Inhibit Time 200 230 250 Output Voltage Overshoot 0 ISOLATION CHARACTERISTICS Isolation Voltage (dielectric strength) Isolation Resistance 100 Isolation Capacitance (input to output) 1000 TEMPERATURE LIMITS FOR POWER DERATING CURVES Semiconductor Junction Temperature 125 Board Temperature 125 Transformer Temperature 125 Maximum Baseplate Temperature, Tb 100 FEATURE CHARACTERISTICS Switching Frequency 230 250 270 ON/OFF Control Off-State Voltage 2.4 18 On-State Voltage -2 0.8 ON/OFF Control Pull-Up Voltage 5 Pull-Up Resistance 50 Over-Temperature Shutdown OTP Trip Point 125 Over-Temperature Shutdown Restart Hysteresis 10 RELIABILITY CHARACTERISTICS Calculated MTBF (Telcordia) TR-NWT-000332 1.49 Calculated MTBF (MIL-217) MIL-HDBK-217F 1.31 Field Demonstrated MTBF Note 1: Output voltage regulation can not be achieved on certain output voltages at or Note 2: Higher values of isolation capacitance can be added external to the module. Product # IQ64xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Units Notes & Conditions V V V Continuous Continuous Reinforced insulation V dc V dc V dc °C °C V V Baseplate temperature See Note 1 V V V V µF µH\µF Not Available Typical ESR 0.1-0.2 Ω Internal values; see Figure D ms ms % Full load, Vout=90% nom. -40 °C to +125 °C; Figure E Maximum Output Capacitance See Absolute Maximum Ratings MΩ pF See Note 2 °C °C °C °C Package rated to 150 °C UL rated max operating temp 130 °C kHz Insulation stage switching freq. is half this V Application notes Figures A & B V kΩ °C °C Average PCB Temperature 106 Hrs. Tb = 70°C 106 Hrs. Tb = 70°C 106 Hrs. See our website for details near 18 V input. Doc.# 005-0005096 Rev. E 11/27/13 Page 2 Technical Specification IQ64xxxQTXxxx Family Figures (all output voltages) 120 Typical Current Limit Inception Point Nominal Vout Output Voltage (%) 100 80 Typical Output Voltage at Shutdown 60 40 Vin min Vin nom 20 Vin max 0 0 Common Figure 1: Typical startup waveform. Input voltage pre-applied, ON/ OFF Pin on Ch 2. 20 30 40 50 60 70 80 90 100 110 120 130 140 150 Load Current (%) Common Figure 2: Output voltage vs. load current showing typical current limit curves and converter shutdown points. 100,000.0 100,000.0 1.8 V 10,000.0 3.3 V 5V 7V 12 V 15 V Trim Resistance (kOhms) Trim Resistance (kOhms) 10 1,000.0 100.0 10.0 24 V 30 V 48 V 10,000.0 1,000.0 100.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0 Increase in Vout (%) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Increase in Vout (%) Common Figure 3: Trim graph for trim-up 1.8 to 12 V outputs. Common Figure 4: Trim graph for trim-up 15 to 48 V outputs. 10,000.0 Trim Resistance (kOhms) All voltages 1,000.0 100.0 10.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Decrease in Vout (%) Common Figure 5: Trim graph for trim down. Product # IQ64xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005096 Rev. E 11/27/13 Page 3 Input:18-135V Output:1.8V Current:36A Part No.:IQ64018QTx36 Technical Specification IQ64018QTx36 Electrical Characteristics(1.8 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 64V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. Units Notes & Conditions INPUT CHARACTERISTICS Maximum Input Current 5.9 A Vin min; trim up; in current limit No-Load Input Current 110 140 mA Disabled Input Current 2 4 mA Response to Input Transient 0.06 V See Figure 6 Input Terminal Ripple Current 500 mA RMS Recommended Input Fuse 20 A Fast acting external fuse recommended OUTPUT CHARACTERISTICS Output Voltage Set Point 1.782 1.800 1.818 V Output Voltage Regulation Over Line ±0.1 ±0.3 % Over Load ±0.1 ±0.3 % Over Temperature -27 27 mV Total Output Voltage Range 1.755 1.845 V Over sample, line, load, temperature & life Output Voltage Ripple and Noise 20 MHz bandwidth; see Note 1 Peak-to-Peak 0 70 140 mV Full load RMS 20 40 mV Full load A Operating Output Current Range 0 36 Subject to thermal derating Output DC Current-Limit Inception 39.6 43.2 46.8 A Output voltage 10% Low Output DC Current-Limit Shutdown Voltage 0.9 V Back-Drive Current Limit while Enabled 1.7 A Negative current drawn from output Back-Drive Current Limit while Disabled 1 mA Negative current drawn from output Maximum Output Capacitance 15,000 µF Vout nominal at full load (resistive load) Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) 120 mV 50% to 75% to 50% Iout max Settling Time 400 µs To within 1% Vout nom Output Voltage Trim Range -20 10 % Across Pins 8&4; Common Figures 3-5; see Note 2 Output Voltage Remote Sense Range 10 % Across Pins 8&4 Output Over-Voltage Protection 2.1 2.2 2.3 V Over full temp range EFFICIENCY 100% Load 80 % See Figure 1 for efficiency curve 50% Load 81 % See Figure 1 for efficiency curve Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Note 2: Trim-up range is limited below 10% at low line and full load. Product # IQ64xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005096 Rev. E 11/27/13 Page 4 Input:18-135V Output:1.8V Current:36A Part No.:IQ64018QTx36 Technical Specification 20 100 95 16 Power Dissipation (W) Efficiency (%) 90 85 80 75 70 18Vin 65 135Vin 12 8 64Vin 0 0 6 12 18 Load Current (A) 24 30 0 36 Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 42 42 36 36 30 30 24 24 18 12 18 Load Current (A) 24 30 36 18 12 400 LFM (2.0 m/s) 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 6 200 LFM (1.0 m/s) 6 6 Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. Iout (A) Iout (A) 64Vin 135Vin 60 12 18Vin 4 100 LFM (0.5 m/s) 100 LFM (0.5 m/s) 0 0 25 40 55 Ambient Air Temperature (°C) 70 25 85 40 55 Ambient Air Temperature (°C) 70 85 Figure 3: Encased Converter (no heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 4: Encased converter (with 1/4" heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.2 A/μs). Load cap: 1 μF ceramic and 15 μF tantalum capacitors. Ch 1: Vout, Ch 2: Iout. Figure 6: Output voltage response to step-change in input voltage (1000 V/ms). Load cap: 1 μF ceramic and 15 μF tantalum capacitors. Ch 1: Vout, Ch 2: Vin. Product # IQ64xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005096 Rev. E 11/27/13 Page 5 Input:18-135V Output:3.3V Current:27A Part No.:IQ64033QTx27 Technical Specification IQ64033QTx27 Electrical Characteristics(3.3 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 64V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. Units Notes & Conditions 7.8 A 100 130 mA 2 4 mA INPUT CHARACTERISTICS Maximum Input Current No-Load Input Current Disabled Input Current Response to Input Transient 0.12 V Input Terminal Ripple Current 500 mA Recommended Input Fuse 20 A 3.300 3.333 V ±0.1 ±0.3 % ±0.1 Vin min; trim up; in current limit See Figure 6 RMS Fast acting external fuse recommended OUTPUT CHARACTERISTICS Output Voltage Set Point 3.267 Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range ±0.3 % -50 50 mV 3.217 3.383 V 100 200 mV Full load 20 40 mV Full load 27 A Subject to thermal derating 35.1 A Output voltage 10% Low Output Voltage Ripple and Noise Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1 Peak-to-Peak 0 RMS Operating Output Current Range 0 Output DC Current-Limit Inception 29.7 Output DC Current-Limit Shutdown Voltage 32.4 1.7 V Back-Drive Current Limit while Enabled 2 A Negative current drawn from output Back-Drive Current Limit while Disabled 1 mA Negative current drawn from output µF Vout nominal at full load (resistive load) Maximum Output Capacitance 10,000 Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) 220 mV 50% to 75% to 50% Iout max Settling Time 400 µs To within 1% Vout nom 10 % Across Pins 8&4; Common Figures 3-5; see Note 2 10 % Across Pins 8&4 4.2 V Over full temp range % See Figure 1 for efficiency curve Output Voltage Trim Range -20 Output Voltage Remote Sense Range Output Over-Voltage Protection 3.9 4.0 EFFICIENCY 100% Load 84 50% Load 83 % See Figure 1 for efficiency curve Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Note 2: Trim-up range is limited below 10% at low line and full load. Product # IQ64xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005096 Rev. E 11/27/13 Page 6 Input:18-135V Output:3.3V Current:27A Part No.:IQ64033QTx27 Technical Specification 100 21 95 18 Power Dissipation (W) Efficiency (%) 90 85 80 75 70 18Vin 9 6 3 135Vin 64Vin 135Vin 0 60 0 3 6 9 12 15 Load Current (A) 18 21 24 0 27 Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 30 30 27 27 24 24 21 21 18 18 15 12 9 400 LFM (2.0 m/s) 6 300 LFM (1.5 m/s) 3 100 LFM (0.5 m/s) 3 6 9 12 15 Load Current (A) 18 21 24 27 Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. Iout (A) Iout (A) 12 18Vin 64Vin 65 15 200 LFM (1.0 m/s) 15 12 9 400 LFM (2.0 m/s) 6 300 LFM (1.5 m/s) 3 100 LFM (0.5 m/s) 200 LFM (1.0 m/s) 0 0 25 40 55 Ambient Air Temperature (°C) 70 25 85 40 55 Ambient Air Temperature (°C) 70 85 Figure 3: Encased Converter (no heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 4: Encased converter (with 1/4" heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.2 A/μs). Load cap: 1 μF ceramic and 15 μF tantalum capacitors. Ch 1: Vout, Ch 2: Iout. Figure 6: Output voltage response to step-change in input voltage (1000 V/ms). Load cap: 1 μF ceramic and 15 μF tantalum capacitors. Ch 1: Vout, Ch 2: Vin. Product # IQ64xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005096 Rev. E 11/27/13 Page 7 Input:18-135V Output:5V Current:20A Part No.:IQ64050QTx20 Technical Specification IQ64050QTx20 Electrical Characteristics(5.0 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 64V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. Units Notes & Conditions 8.6 A 100 130 mA 2 4 mA INPUT CHARACTERISTICS Maximum Input Current No-Load Input Current Disabled Input Current Response to Input Transient 0.2 V Input Terminal Ripple Current 600 mA Recommended Input Fuse 20 A 5.000 5.050 V ±0.1 ±0.3 % ±0.1 Vin min; trim up; in current limit See Figure 6 RMS Fast acting external fuse recommended OUTPUT CHARACTERISTICS Output Voltage Set Point 4.950 Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range ±0.3 % -75 75 mV 4.875 5.125 V 100 200 mV Full load 20 40 mV Full load 20 A Subject to thermal derating 26.0 A Output voltage 10% Low Output Voltage Ripple and Noise Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1 Peak-to-Peak 0 RMS Operating Output Current Range 0 Output DC Current-Limit Inception 22.0 Output DC Current-Limit Shutdown Voltage 24.0 1.8 V Back-Drive Current Limit while Enabled 2 A Negative current drawn from output Back-Drive Current Limit while Disabled 1 mA Negative current drawn from output µF Vout nominal at full load (resistive load) Maximum Output Capacitance 8,000 Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) 260 mV 50% to 75% to 50% Iout max Settling Time 400 µs To within 1% Vout nom 10 % Across Pins 8&4; Common Figures 3-5 10 % Across Pins 8&4 6.4 V Over full temp range % See Figure 1 for efficiency curve Output Voltage Trim Range -20 Output Voltage Remote Sense Range Output Over-Voltage Protection 5.9 6.1 EFFICIENCY 100% Load 85 50% Load 87 % See Figure 1 for efficiency curve Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Product # IQ64xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005096 Rev. E 11/27/13 Page 8 Input:18-135V Output:5V Current:20A Part No.:IQ64050QTx20 Technical Specification 25 100 95 20 Power Dissipation (W) Efficiency (%) 90 85 80 75 70 18Vin 18Vin 64Vin 135Vin 135Vin 0 60 0 5 10 Load Current (A) 15 0 20 Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 25 25 20 20 15 15 10 10 Load Current (A) 15 20 10 400 LFM (2.0 m/s) 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 5 5 Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. Iout (A) Iout (A) 10 5 64Vin 65 15 300 LFM (1.5 m/s) 5 200 LFM (1.0 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) 100 LFM (0.5 m/s) 0 0 25 40 55 Ambient Air Temperature (°C) 70 25 85 40 55 Ambient Air Temperature (°C) 70 85 Figure 3: Encased Converter (no heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 4: Encased converter (with 1/4" heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.2 A/μs). Load cap: 1 μF ceramic and 15 μF tantalum capacitors. Ch 1: Vout, Ch 2: Iout. Figure 6: Output voltage response to step-change in input voltage (1000 V/ms). Load cap: 1 μF ceramic and 15 μF tantalum capacitors. Ch 1: Vout, Ch 2: Vin. Product # IQ64xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005096 Rev. E 11/27/13 Page 9 Input:18-135V Output:7V Current:14A Part No.:IQ64070QTx14 Technical Specification IQ64070QTx14 Electrical Characteristics(7.0 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 64V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. Units Notes & Conditions 8.2 A 100 130 mA 2 4 mA INPUT CHARACTERISTICS Maximum Input Current No-Load Input Current Disabled Input Current Response to Input Transient 0.23 V Input Terminal Ripple Current 800 mA Recommended Input Fuse 20 A 7.000 7.070 V ±0.1 ±0.3 % ±0.1 Vin min; trim up; in current limit See Figure 6 RMS Fast acting external fuse recommended OUTPUT CHARACTERISTICS Output Voltage Set Point 6.930 Output Voltage Regulation Over Line Over Load ±0.3 % Over Temperature -105 105 mV Total Output Voltage Range 6.825 7.175 V 100 200 mV Full load 20 40 mV Full load 14 A Subject to thermal derating 18.2 A Output voltage 10% Low Output Voltage Ripple and Noise Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1 Peak-to-Peak 0 RMS Operating Output Current Range 0 Output DC Current-Limit Inception 15.4 16.8 Output DC Current-Limit Shutdown Voltage 0.9 V Back-Drive Current Limit while Enabled 0.55 A Negative current drawn from output Back-Drive Current Limit while Disabled 1 mA Negative current drawn from output µF Vout nominal at full load (resistive load) Maximum Output Capacitance 8,000 Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) 260 mV 50% to 75% to 50% Iout max Settling Time 400 µs To within 1% Vout nom 10 % Across Pins 8&4; Common Figures 3-5; see Note 2 10 % Across Pins 8&4 8.9 V Over full temp range % See Figure 1 for efficiency curve Output Voltage Trim Range -20 Output Voltage Remote Sense Range Output Over-Voltage Protection 8.2 8.5 EFFICIENCY 100% Load 88 50% Load 87 % See Figure 1 for efficiency curve Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Note 2: Trim-up range is limited below 10% at low line and full load. Product # IQ64xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005096 Rev. E 11/27/13 Page 10 Input:18-135V Output:7V Current:14A Part No.:IQ64070QTx14 Technical Specification 100 18 95 15 Power Dissipation (W) Efficiency (%) 90 85 80 75 70 18Vin 6 18Vin 64Vin 135Vin 135Vin 0 60 0 2 4 6 8 Load Current (A) 10 12 0 14 Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 2 4 6 8 Load Current (A) 10 12 14 Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 16 16 14 14 12 12 10 10 Iout (A) Iout (A) 9 3 64Vin 65 12 8 8 6 6 400 LFM (2.0 m/s) 4 200 LFM (1.0 m/s) 2 400 LFM (2.0 m/s) 4 300 LFM (1.5 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 2 100 LFM (0.5 m/s) 100 LFM (0.5 m/s) 0 0 25 40 55 Ambient Air Temperature (°C) 70 25 85 40 55 Ambient Air Temperature (°C) 70 85 Figure 3: Encased Converter (no heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 4: Encased converter (with 1/4" heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.2 A/μs). Load cap: 1 μF ceramic and 15 μF tantalum capacitors. Ch 1: Vout, Ch 2: Iout. Figure 6: Output voltage response to step-change in input voltage (1000 V/ms). Load cap: 1 μF ceramic and 15 μF tantalum capacitors. Ch 1: Vout, Ch 2: Vin. Product # IQ64xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005096 Rev. E 11/27/13 Page 11 Input:18-135V Output:12V Current:8A Part No.:IQ64120QTx08 Technical Specification IQ64120QTx08 Electrical Characteristics(12.0 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 64V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. Units Notes & Conditions 7.2 A 100 130 mA 2 4 mA INPUT CHARACTERISTICS Maximum Input Current No-Load Input Current Disabled Input Current Response to Input Transient 0.37 V Input Terminal Ripple Current 800 mA Recommended Input Fuse 20 A 12.00 12.12 V ±0.1 ±0.3 % ±0.1 Vin min; Vout nom; in current limit RMS Fast acting external fuse recommended OUTPUT CHARACTERISTICS Output Voltage Set Point 11.88 Output Voltage Regulation see Note 3 Over Line Over Load see Note 3 ±0.3 % Over Temperature -180 180 mV Total Output Voltage Range 11.70 12.30 V 110 220 mV Full load 20 40 mV Full load 8 A Subject to thermal derating 10.4 A Output voltage 10% Low Output Voltage Ripple and Noise Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1 Peak-to-Peak 0 RMS Operating Output Current Range 0 Output DC Current-Limit Inception 8.8 Output DC Current-Limit Shutdown Voltage 9.6 6 V Back-Drive Current Limit while Enabled 0.5 A Negative current drawn from output Back-Drive Current Limit while Disabled 1 mA Negative current drawn from output µF Vout nominal at full load (resistive load) Maximum Output Capacitance 1,500 Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) 360 mV 50% to 75% to 50% Iout max Settling Time 400 µs To within 1% Vout nom 10 % Across Pins 8&4; Common Figures 3-5; see Note 2 10 % Across Pins 8&4 15.2 V Over full temp range % See Figure 1 for efficiency curve Output Voltage Trim Range -20 Output Voltage Remote Sense Range Output Over-Voltage Protection 14.0 14.6 EFFICIENCY 100% Load 89 50% Load 87 % See Figure 1 for efficiency curve Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Note 2: Trim-up range is limited below 10% at an input voltage less than 21 V. Note 3: Output voltage regulation cannot be achieved for an input voltage less than 19V. Product # IQ64xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005096 Rev. E 11/27/13 Page 12 Input:18-135V Output:12V Current:8A Part No.:IQ64120QTx08 Technical Specification 100 18 95 15 Power Dissipation (W) Efficiency (%) 90 85 80 75 70 18Vin 6 18Vin 64Vin 135Vin 135Vin 0 60 0 1 2 3 4 5 Load Current (A) 6 7 0 8 Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 10 10 8 8 6 6 4 2 3 4 5 6 Load Current (A) 7 8 4 400 LFM (2.0 m/s) 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 2 1 Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. Iout (A) Iout (A) 9 3 64Vin 65 12 300 LFM (1.5 m/s) 2 200 LFM (1.0 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) 100 LFM (0.5 m/s) 0 0 25 40 55 Ambient Air Temperature (°C) 70 25 85 40 55 Ambient Air Temperature (°C) 70 85 Figure 3: Encased Converter (no heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 4: Encased converter (with 1/4" heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.2 A/μs). Load cap: 1 μF ceramic and 15 μF tantalum capacitors. Ch 1: Vout, Ch 2: Iout. Figure 6: Output voltage response to step-change in input voltage (1000 V/ms). Load cap: 1 μF ceramic and 15 μF tantalum capacitors. Ch 1: Vout, Ch 2: Vin. Product # IQ64xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005096 Rev. E 11/27/13 Page 13 Input:18-135V Output:15V Current:6.5A Part No.:IQ64150QTx07 Technical Specification IQ64150QTx07 Electrical Characteristics(15.0 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 64V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. Units Notes & Conditions 7.4 A 100 130 mA 2 4 mA INPUT CHARACTERISTICS Maximum Input Current No-Load Input Current Disabled Input Current Response to Input Transient 0.47 V Input Terminal Ripple Current 800 mA Recommended Input Fuse 20 A 15.00 15.15 V ±0.1 ±0.3 % ±0.1 Vin min; Vout nom; in current limit See Figure 6 RMS Fast acting external fuse recommended OUTPUT CHARACTERISTICS Output Voltage Set Point 14.85 Output Voltage Regulation Over Line Over Load ±0.3 % Over Temperature -225 225 mV Total Output Voltage Range 14.62 15.38 V 220 mV Full load Full load Output Voltage Ripple and Noise Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1 Peak-to-Peak 110 RMS 30 Operating Output Current Range 0 Output DC Current-Limit Inception 7.2 Output DC Current-Limit Shutdown Voltage 7.8 60 mV 6.5 A Subject to thermal derating 8.5 A Output voltage 10% Low 7.5 V Back-Drive Current Limit while Enabled 0.35 A Negative current drawn from output Back-Drive Current Limit while Disabled 1 mA Negative current drawn from output µF Vout nominal at full load (resistive load) Maximum Output Capacitance 1,000 Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) 520 mV 50% to 75% to 50% Iout max Settling Time 400 µs To within 1% Vout nom 10 % Across Pins 8&4; Common Figures 3-5; see Note 2 10 % Across Pins 8&4 19.1 V Over full temp range % See Figure 1 for efficiency curve Output Voltage Trim Range -20 Output Voltage Remote Sense Range Output Over-Voltage Protection 17.6 18.3 EFFICIENCY 100% Load 88 50% Load 87 % See Figure 1 for efficiency curve Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Note 2: Trim-up range is limited below 10% at an input voltage less than 20 V. Product # IQ64xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005096 Rev. E 11/27/13 Page 14 Input:18-135V Output:15V Current:6.5A Part No.:IQ64150QTx07 Technical Specification 100 21 95 18 Efficiency (%) 85 80 75 70 18Vin 65 135Vin 15 Power Dissipation (W) 90 64Vin 12 9 6 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 Load Current (A) 4.5 5.0 5.5 6.0 0.0 7 7 6 6 5 5 4 4 3 1.0 1.5 2.0 2.5 3.0 3.5 4.0 Load Current (A) 4.5 5.0 5.5 6.0 6.5 3 2 400 LFM (2.0 m/s) 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 1 0.5 Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. Iout (A) Iout (A) 135Vin 0 6.5 Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 2 64Vin 3 60 0.0 18Vin 200 LFM (1.0 m/s) 1 100 LFM (0.5 m/s) 100 LFM (0.5 m/s) 0 0 25 40 55 Ambient Air Temperature (°C) 70 25 85 40 55 Ambient Air Temperature (°C) 70 85 Figure 3: Encased Converter (no heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 4: Encased converter (with 1/4" heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.2 A/μs). Load cap: 1 μF ceramic and 15 μF tantalum capacitors. Ch 1: Vout, Ch 2: Iout. Figure 6: Output voltage response to step-change in input voltage (1000 V/ms). Load cap: 1 μF ceramic and 15 μF tantalum capacitors. Ch 1: Vout, Ch 2: Vin. Product # IQ64xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005096 Rev. E 11/27/13 Page 15 Input:18-135V Output:24V Current:4A Part No.:IQ64240QTx04 Technical Specification IQ64240QTx04 Electrical Characteristics(24.0 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 64V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. Units Notes & Conditions 8.0 A 100 130 mA 2 4 mA INPUT CHARACTERISTICS Maximum Input Current No-Load Input Current Disabled Input Current Response to Input Transient 0.88 V Input Terminal Ripple Current 800 mA Recommended Input Fuse 20 A 24.00 24.24 V ±0.1 ±0.3 % ±0.1 Vin min; trim up; in current limit See Figure 6 RMS Fast acting external fuse recommended OUTPUT CHARACTERISTICS Output Voltage Set Point 23.76 Output Voltage Regulation Over Line Over Load ±0.3 % Over Temperature -360 360 mV Total Output Voltage Range 23.40 24.60 V 110 220 mV Full load 20 40 mV Full load 4 A Subject to thermal derating 5.2 A Output voltage 10% Low Output Voltage Ripple and Noise Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1 Peak-to-Peak 0 RMS Operating Output Current Range 0 Output DC Current-Limit Inception 4.4 Output DC Current-Limit Shutdown Voltage 4.8 12 V Back-Drive Current Limit while Enabled 0.15 A Negative current drawn from output Back-Drive Current Limit while Disabled 1 mA Negative current drawn from output µF Vout nominal at full load (resistive load) Maximum Output Capacitance 400 Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) 800 mV 50% to 75% to 50% Iout max Settling Time 400 µs To within 1% Vout nom 10 % Across Pins 8&4; Common Figures 3-5 10 % Across Pins 8&4 30.5 V Over full temp range % See Figure 1 for efficiency curve Output Voltage Trim Range -20 Output Voltage Remote Sense Range Output Over-Voltage Protection 28.1 29.3 EFFICIENCY 100% Load 88 50% Load 88 % See Figure 1 for efficiency curve Note 1: Output is terminated with 1 µF ceramic capacitor. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Product # IQ64xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005096 Rev. E 11/27/13 Page 16 Input:18-135V Output:24V Current:4A Part No.:IQ64240QTx04 Technical Specification 100 18 95 15 Power Dissipation (W) Efficiency (%) 90 85 80 75 70 18Vin 6 18Vin 64Vin 135Vin 135Vin 0 60 0 1 2 Load Current (A) 3 0 4 Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 5.0 5.0 4.5 4.5 4.0 4.0 3.5 3.5 3.0 3.0 2.5 2.0 1.5 400 LFM (2.0 m/s) 1.0 300 LFM (1.5 m/s) 0.5 100 LFM (0.5 m/s) 1 2 3 Load Current (A) 4 Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. Iout (A) Iout (A) 9 3 64Vin 65 12 200 LFM (1.0 m/s) 2.5 2.0 1.5 400 LFM (2.0 m/s) 1.0 300 LFM (1.5 m/s) 0.5 100 LFM (0.5 m/s) 200 LFM (1.0 m/s) 0.0 0.0 25 40 55 Ambient Air Temperature (°C) 70 25 85 40 55 Ambient Air Temperature (°C) 70 85 Figure 3: Encased Converter (no heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 4: Encased converter (with 1/4" heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.2 A/μs). Load cap: 1 μF ceramic capacitor. Ch 1: Vout, Ch 2: Iout. Figure 6: Output voltage response to step-change in input voltage (1000 V/ms). Load cap: 1 μF ceramic capacitor. Ch 1: Vout, Ch 2: Vin. Product # IQ64xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005096 Rev. E 11/27/13 Page 17 Input:18-135V Output:30V Current:3.2A Part No.:IQ64300QTx03 Technical Specification IQ64300QTx03 Electrical Characteristics(30.0 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 64V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. Units Notes & Conditions 8.0 A 100 130 mA 2 4 mA INPUT CHARACTERISTICS Maximum Input Current No-Load Input Current Disabled Input Current Response to Input Transient 1.15 V Input Terminal Ripple Current 900 mA Recommended Input Fuse 20 A 30.00 30.30 V ±0.1 ±0.3 % ±0.1 Vin min; trim up; in current limit See Figure 6 RMS Fast acting external fuse recommended OUTPUT CHARACTERISTICS Output Voltage Set Point 29.70 Output Voltage Regulation Over Line Over Load ±0.3 % Over Temperature -450 450 mV Total Output Voltage Range 29.25 30.75 V 220 mV Full load Full load Output Voltage Ripple and Noise Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1 Peak-to-Peak 0 RMS 110 20 Operating Output Current Range 0 Output DC Current-Limit Inception 3.5 Output DC Current-Limit Shutdown Voltage 3.8 40 mV 3.2 A Subject to thermal derating 4.2 A Output voltage 10% Low 19 V Back-Drive Current Limit while Enabled 0.13 A Negative current drawn from output Back-Drive Current Limit while Disabled 1 mA Negative current drawn from output µF Vout nominal at full load (resistive load) Maximum Output Capacitance 250 Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) 1100 mV 50% to 75% to 50% Iout max Settling Time 400 µs To within 1% Vout nom 10 % Across Pins 8&4; Common Figures 3-5 10 % Across Pins 8&4 38.1 V Over full temp range % See Figure 1 for efficiency curve Output Voltage Trim Range -20 Output Voltage Remote Sense Range Output Over-Voltage Protection 35.1 36.6 EFFICIENCY 100% Load 88 50% Load 88 % See Figure 1 for efficiency curve Note 1: Output is terminated with 1 µF ceramic capacitor. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Product # IQ64xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005096 Rev. E 11/27/13 Page 18 Input:18-135V Output:30V Current:3.2A Part No.:IQ64300QTx03 Technical Specification 100 18 95 15 Power Dissipation (W) Efficiency (%) 90 85 80 75 70 18Vin 6 18Vin 64Vin 135Vin 135Vin 0 60 0.0 0.4 0.8 1.2 1.6 2.0 Load Current (A) 2.4 2.8 0.0 3.2 Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 3.6 3.6 3.2 3.2 2.8 2.8 2.4 2.4 2.0 2.0 1.6 400 LFM (2.0 m/s) 0.8 1.2 1.6 2.0 Load Current (A) 2.4 2.8 3.2 400 LFM (2.0 m/s) 0.8 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 0.4 0.8 1.6 1.2 1.2 0.4 Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. Iout (A) Iout (A) 9 3 64Vin 65 12 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 0.4 100 LFM (0.5 m/s) 100 LFM (0.5 m/s) 0.0 0.0 25 40 55 Ambient Air Temperature (°C) 70 25 85 40 55 Ambient Air Temperature (°C) 70 85 Figure 3: Encased Converter (no heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 4: Encased converter (with 1/4" heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.2 A/μs). Load cap: 1 μF ceramic capacitor. Ch 1: Vout, Ch 2: Iout. Figure 6: Output voltage response to step-change in input voltage (1000 V/ms). Load cap: 1 μF ceramic capacitor. Ch 1: Vout, Ch 2: Vin. Product # IQ64xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005096 Rev. E 11/27/13 Page 19 Input:18-135V Output:48V Current:2A Part No.:IQ64480QTx02 Technical Specification IQ64480QTx02 Electrical Characteristics(48.0 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 64V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. Units Notes & Conditions 8.2 A 100 130 mA 2 4 mA INPUT CHARACTERISTICS Maximum Input Current No-Load Input Current Disabled Input Current Response to Input Transient 2.2 V Input Terminal Ripple Current 900 mA Recommended Input Fuse 20 A 48.00 48.48 V ±0.1 ±0.3 % ±0.1 Vin min; trim up; in current limit See Figure 6 RMS Fast acting external fuse recommended OUTPUT CHARACTERISTICS Output Voltage Set Point 47.52 Output Voltage Regulation Over Line Over Load ±0.3 % Over Temperature -720 720 mV Total Output Voltage Range 46.80 49.20 V 110 220 mV Full load 20 40 mV Full load 2 A Subject to thermal derating 2.60 A Output voltage 10% Low Output Voltage Ripple and Noise Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1 Peak-to-Peak 0 RMS Operating Output Current Range 0 Output DC Current-Limit Inception 2.20 2.40 Output DC Current-Limit Shutdown Voltage 22 V Back-Drive Current Limit while Enabled 0.1 A Negative current drawn from output Back-Drive Current Limit while Disabled 2 mA Negative current drawn from output µF Vout nominal at full load (resistive load) Maximum Output Capacitance 100 Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) 1700 mV 50% to 75% to 50% Iout max Settling Time 400 µs To within 1% Vout nom 10 % Across Pins 8&4; Common Figures 3-5 10 % Across Pins 8&4 61.0 V Over full temp range % See Figure 1 for efficiency curve Output Voltage Trim Range -20 Output Voltage Remote Sense Range Output Over-Voltage Protection 56.2 58.6 EFFICIENCY 100% Load 86 50% Load 87 % See Figure 1 for efficiency curve Note 1: Output is terminated with 1 µF ceramic capacitor. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Product # IQ64xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005096 Rev. E 11/27/13 Page 20 Input:18-135V Output:48V Current:2A Part No.:IQ64480QTx02 Technical Specification 100 21 95 18 Power Dissipation (W) Efficiency (%) 90 85 80 75 70 18Vin 9 6 3 135Vin 64Vin 135Vin 0 60 0.0 0.5 1.0 Load Current (A) 1.5 0.0 2.0 Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 2.5 2.5 2.0 2.0 1.5 1.5 1.0 1.0 Load Current (A) 1.5 2.0 1.0 400 LFM (2.0 m/s) 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 0.5 0.5 Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. Iout (A) Iout (A) 12 18Vin 64Vin 65 15 300 LFM (1.5 m/s) 0.5 200 LFM (1.0 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) 100 LFM (0.5 m/s) 0.0 0.0 25 40 55 Ambient Air Temperature (°C) 70 25 85 40 55 Ambient Air Temperature (°C) 70 85 Figure 3: Encased Converter (no heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 4: Encased converter (with 1/4" heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.2 A/μs). Load cap: 1 μF ceramic capacitor. Ch 1: Vout, Ch 2: Iout. Figure 6: Output voltage response to step-change in input voltage (1000 V/ms). Load cap: 1 μF ceramic capacitor. Ch 1: Vout, Ch 2: Vin. Product # IQ64xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005096 Rev. E 11/27/13 Page 21 Technical Specification IQ64xxxQTXxxx Application Section BASIC OPERATION AND FEATURES CONTROL FEATURES This converter series uses a two-stage power topology. The first stage is a buck-converter that output voltage constant over variations in line, temperature. The second stage uses a transformer the functions of input/output isolation and voltage step-down to achieve the output voltage required. REMOTE ON/OFF (Pin 2): The ON/OFF input, Pin 2, permits the user to control when the converter is on or off. This input is referenced to the return terminal of the input bus, Vin(-). The ON/OFF signal is active low (meaning that a low turns the converter on). Figure A details four possible circuits for driving the ON/OFF pin. Figure B is a detailed look of the internal ON/ OFF circuitry. conversion keeps the load, and to provide step-up or Both the first stage and the second stage switch at a fixed frequency for predictable EMI performance. Rectification of the transformer’s output is accomplished with synchronous rectifiers. These devices, which are MOSFETs with a very low on-state resistance, dissipate far less energy than Schottky diodes. This is the primary reason that the converter has such high efficiency, even at very low output voltages and very high output currents. These converters are offered totally encased to withstand harsh environments and thermally demanding applications. Dissipation throughout the converter is so low that it does not require a heatsink for operation in many applications; however, adding a heatsink provides improved thermal derating performance in extreme situations. This series of converters use the industry standard footprint and pin-out configuration. ON/OFF ON/OFF Vin(_) Vin(_) Remote Enable Circuit REMOTE SENSE(+) (Pins 7 and 5): The SENSE(+) inputs correct for voltage drops along the conductors that connect the converter’s output pins to the load. Pin 7 should be connected to Vout(+) and Pin 5 should be connected to Vout(-) at the point on the board where regulation is desired. A remote connection at the load can adjust for a voltage drop only as large as that specified in this datasheet, that is [Vout(+) - Vout(-)] – [Vsense(+) - Vsense(-)] < Sense Range % x Vout Pins 7 and 5 must be connected for proper regulation of the output voltage. If these connections are not made, the converter will deliver an output voltage that is slightly higher than its specified value. Note: the output over-voltage protection circuit senses the voltage across the output (pins 8 and 4) to determine when it should trigger, not the voltage across the converter’s sense leads (pins 7 and 5). Therefore, the resistive drop on the board should be small enough so that output OVP does not trigger, even during load transients. 5V Negative Logic (Permanently Enabled) 5V ON/OFF TTL/ CMOS 50k ON/OFF ON/OFF 50k TTL Vin(_) Vin(_ ) Open Collector Enable Circuit Figure A: Various circuits for driving the ON/OFF pin. Product # IQ64xxxQTXxxx 100pF Vin(-) Direct Logic Drive Phone 1-888-567-9596 Figure B: Internal ON/OFF pin circuitry www.synqor.com Doc.# 005-0005096 Rev. E 11/27/13 Page 22 Technical Specification IQ64xxxQTXxxx Application Section OUTPUT VOLTAGE TRIM (Pin 6): The TRIM input permits the user to adjust the output voltage across the sense leads up or down according to the trim range specifications. To decrease the output voltage, the user should connect a resistor between Pin 6 and Pin 5 (SENSE(-) input). For a desired decrease of the nominal output voltage, the value of the resistor should be Rtrim-down = - 10.22 (511 D% ) (kW) where D% = Vnominal – Vdesired Vnominal x 100% To increase the output voltage, the user should connect a resistor between Pin 6 and Pin 7 (SENSE(+) input). For a desired increase of the nominal output voltage, the value of the resistor should be Rtrim-up = where ( 5.11VOUT x (100+D%) 1.225D% _ 511 _ 10.22 D% ) (kW) Vout = Nominal Output Voltage Trim graphs show the relationship between the trim resistor value and Rtrim-up and Rtrim-down, showing the total range the output voltage can be trimmed up or down. Note: the TRIM feature does not affect the voltage at which the output over-voltage protection circuit is triggered. Trimming the output voltage too high may cause the over-voltage protection circuit to engage, particularly during transients. It is not necessary for the user to add capacitance at the Trim pin. The node is internally bypassed to eliminate noise. Total DC Variation of VOUT: For the converter to meet its full specifications, the maximum variation of the dc value of VOUT, due to both trimming and remote load voltage drops, should not be greater than that specified for the output voltage trim range. Product # IQ64xxxQTXxxx Phone 1-888-567-9596 PROTECTION FEATURES Input Under-Voltage Lockout: The converter is designed to turn off when the input voltage is too low, helping avoid an input system instability problem, described in more detail in the application note titled “Input System Instability” on our website. The lockout circuitry is a comparator with dc hysteresis. When the input voltage is rising, it must exceed the typical TurnOn Voltage Threshold value (listed on the specifications page) before the converter will turn on. Once the converter is on, the input voltage must fall below the typical Turn-Off Voltage Threshold value before the converter will turn off. Output Current Limit: The maximum current limit remains constant as the output voltage drops. However, once the impedance of the load across the output is small enough to make the output voltage drop below the specified Output DC CurrentLimit Shutdown Voltage, the converter turns off. The converter then enters a “hiccup mode” where it repeatedly turns on and off at a 5 Hz (nominal) frequency with a 5% duty cycle until the short circuit condition is removed. This prevents excessive heating of the converter or the load board. Output Over-Voltage Limit: If the voltage across the output pins exceeds the Output Over-Voltage Protection threshold, the converter will immediately stop switching. This prevents damage to the load circuit due to 1) excessive series resistance in output current path from converter output pins to sense point, 2) a release of a short-circuit condition, or 3) a release of a current limit condition. Load capacitance determines exactly how high the output voltage will rise in response to these conditions. After 200 ms the converter will automatically restart. Over-Temperature Shutdown: A temperature sensor on the converter senses the average temperature of the module. The thermal shutdown circuit is designed to turn the converter off when the temperature at the sensed location reaches the Over-Temperature Shutdown value. It will allow the converter to turn on again when the temperature of the sensed location falls by the amount of the Over-Temperature Shutdown Restart Hysteresis value. www.synqor.com Doc.# 005-0005096 Rev. E 11/27/13 Page 23 Technical Specification IQ64xxxQTXxxx Application Section APPLICATION CONSIDERATIONS Input System Instability: This condition can occur because any dc-dc converter appears incrementally as a negative resistance load. A detailed application note titled “Input System Instability” is available on the SynQor website which provides an understanding of why this instability arises, and shows the preferred solution for correcting it. Application Circuits: Figure C provides a typical circuit diagram which details the input filtering and voltage trimming. Vin(+) Vin External Input Filter Electrolytic Capacitor Vout(+) Vsense(+) ON/OFF Trim Vsense(_) Vin(_) Rtrim-up or Rtrim-down Cload Iload Vout(_) Figure C: Typical application circuit (negative logic unit, permanently enabled). Input Filtering and External Capacitance: Figure D provides a diagram showing the internal input filter components. This filter dramatically reduces input terminal ripple current, which otherwise could exceed the rating of an external electrolytic input capacitor. The recommended external input capacitance is specified in the Input Characteristics section on the Electrical Characteristics page. More detailed information is available in the application note titled “EMI Characteristics” on the SynQor website. L Vin(+) C Vin(_) Figure D: Internal Input Filter Diagram (component values listed on the specifications page). Product # IQ64xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005096 Rev. E 11/27/13 Page 24 Technical Specification IQ64xxxQTXxxx Application Section Startup Inhibit Period: The Startup Inhibit Period ensures that the converter will remain off for approximately 200 ms when it is shut down for any reason. When an output short is present, this generates a 5 Hz “hiccup mode,” which prevents the converter from overheating. In all, there are seven ways that the converter can be shut down, initiating a Startup Inhibit Period: • InputUnder-VoltageLockout When the ON/OFF pin goes high after t2, the Startup Inhibit Period has elapsed, and the output turns on within the typical Turn-On Time. Thermal Considerations: The maximum operating base-plate temperature, TB, is 100 ºC. As long as the user’s thermal system keeps TB < 100 ºC, the converter can deliver its full rated power. A power derating curve can be calculated for any heatsink that is attached to the base-plate of the converter. It is only necessary to determine the thermal resistance, RTHBA, of the chosen heatsink between the base-plate and the ambient air for a given airflow rate. This information is usually available from the heatsink vendor. The following formula can the be used to determine the maximum power the converter can dissipate for a given thermal condition if its base-plate is to be no higher than 100 ºC. • InputOver-VoltageLockout • OutputOver-VoltageProtection • OverTemperatureShutdown • CurrentLimit • ShortCircuitProtection • TurnedoffbytheON/OFFinput Figure E shows three turn-on scenarios, where a Startup Inhibit Period is initiated at t0, t1, and t2: Before time t0, when the input voltage is below the UVL threshold, the unit is disabled by the Input Under-Voltage Lockout feature. When the input voltage rises above the UVL threshold, the Input Under-Voltage Lockout is released, and a Startup Inhibit Period is initiated. At the end of this delay, the ON/OFF pin is evaluated, and since it is active, the unit turns on. At time t1, the unit is disabled by the ON/OFF pin, and it cannot be enabled again until the Startup Inhibit Period has elapsed. max Pdiss = 100 ºC - TA RTHBA This value of power dissipation can then be used in conjunction with the data shown in Figure 2 to determine the maximum load current (and power) that the converter can deliver in the given thermal condition. For convenience, power derating curves for an encased converter without a heatsink and with a typical heatsink are provided for each output voltage. Vin Under-Voltage Lockout TurnOn Threshold ON/OFF (neg logic) ON OFF ON OFF ON 10ms Vout (typical turn on time) 230ms (typical start-up inhibit period) t1 t0 200ms 200ms t2 t Figure E: Startup Inhibit Period (turn-on time not to scale) Product # IQ64xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005096 Rev. E 11/27/13 Page 25 Technical Specification IQ64xxxQTXxxx Standards & Qualification Testing Parameter Notes & Conditions STANDARDS COMPLIANCE UL 60950-1/R:2011-12 Reinforced Insulation CAN/CSA-C22.2 No. 60950-1/A1:2011 EN 60950-1/A12:2011 CE Marked 2006/95/EC Low Voltage Directive Note: An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new releases or download from the SynQor website. Parameter # Units Test Conditions QUALIFICATION TESTING Life Test 32 95% rated Vin and load, units at derating point, 1000 hours Vibration 5 10-55 Hz sweep, 0.060" total excursion, 1 min./sweep, 120 sweeps for 3 axis Mechanical Shock 5 100g minimum, 2 drops in x, y, and z axis Temperature Cycling 10 -40 °C to 100 °C, unit temp. ramp 15 °C/min., 500 cycles Power/Thermal Cycling 5 Toperating = min to max, Vin = min to max, full load, 100 cycles Design Marginality 5 Tmin-10 °C to Tmax+10 °C, 5 °C steps, Vin = min to max, 0-105% load Humidity 5 85 °C, 95% RH, 1000 hours, continuous Vin applied except 5 min/day Solderability 15 pins Altitude 2 MIL-STD-883, method 2003 70,000 feet (21 km), see Note Note: A conductive cooling design is generally needed for high altitude applications because of naturally poor convective cooling at rare atmospheres. Product # IQ64xxxQTXxxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005096 Rev. E 11/27/13 Page 26 Technical Specification IQ64xxxQTXxxx Standard Mechanical Diagram 1.536 ±0.020 (39.01 ±0.5) 1. 030 (26.16) 0.600 (15.24) Top View Side View 0.450 (11.43) 0.300 (7.62) 0.150 (3.81) 0.253±0.020 (6.4±0.5) 0.18±0.010 (4.57±0.25) 0.263±0.020 (6.68±0.5) 8 7 6 5 4 2.386 ± 0.020 (60.6± 0.5) 2.00 (50.8) 1.86 (47.2) M3 Threaded Inserts 4 Places See Notes 1 2 3 0.183±.020 (4.65)±0.5 0.500±0.025 (12.7±0.63) Overall Height 0.468±0.020 (11.89±0.5) 0.300 (7.62) 0.600 (15.24) NOTES 1)M3 screws used to bolt unit’s baseplate to other surfaces (such as a heatsink) must not exceed 0.100" (2.54 mm) depth below the surface of the baseplate. PIN DESIGNATIONS Pin Name Function 1 Vin(+) Positive input voltage 2 ON/OFF 3 Vin(–) 2)Applied torque per screw should not exceed 6in-lb. (0.7 Nm). 3)Baseplate flatness tolerance is 0.004" (.10mm) TIR for surface. 4)Pins 1-3, 5-7 are 0.040” (1.02mm) diameter, with 0.080” (2.03mm) diameter standoff shoulders. 5)Pins 4 and 8 are 0.062” (1.57 mm) diameter with 0.100" (2.54 mm) diameter standoff shoulders. 6)All Pins: Material - Copper Alloy- Finish (RoHS 6/6) - Matte Tin over Nickel plate 7)Weight: 3.02 oz. (85.7 g) typical 8)All dimensions in inches (mm) Tolerances: x.xx +/-0.02 in. (x.x +/-0.5mm) x.xxx +/-0.010 in. (x.xx +/-0.25mm) 9)Workmanship: Meets or exceeds IPC-A-610 Class II 10)Recommended pin length is 0.03” (0.76mm) greater than the PCB thickness. Product # IQ64xxxQTXxxx Phone 1-888-567-9596 4 Vout(–) TTL input to turn converter on and off, referenced to Vin(–), with internal pull up. Negative input voltage Negative output voltage 6 SENSE(–) Negative remote sense1 TRIM Output voltage trim2 7 SENSE(+) Positive remote sense3 5 8 Vout(+) Positive output voltage Notes: 1) SENSE(–) should be connected to Vout(–) either remotely or at the converter. 2) Leave TRIM pin open for nominal output voltage. 3) SENSE(+) should be connected to Vout(+) either remotely or at the converter. www.synqor.com Doc.# 005-0005096 Rev. E 11/27/13 Page 27 Technical Specification IQ64xxxQTXxxx Flanged Mechanical Diagram .01 [0.2] OVERALL HEIGHT .500 ±.025 [12.7 ±0.63] 2.200 ±.020 [ 55.88 ±0.5 ] 1.536 ±.020 [ 39.01 ±0.5 ] .18 [ 4.6 ] SEE NOTE 5 R .065 4 [ 1.65 ] TOP VIEW 2.00 [ 50.8 ] 2.07 [ 52.5 ] 1.66 [ 42.2 ] 2.386 [ 60.6 5 6 7 .60 [ 15.2 ] .45 [ 11.4 ] .30 [ 7.6 ] .15 [ 3.8 ] 8 BOTTOM VIEW ±.020 ±0.5 ] 1.01 [25.7] .36 [9.1] 3 1 .70 [ 17.8 ] .183 ±.020 [ 4.65 ±0.5 ] .02 [ 0.6 ] 1.30 [ 33 ] .13 [ 3.2 ] .800 ±.020 [ 20.32 ±0.5 ] 1 BOTTOMSIDE CLEARANCE .010 ±.020 [0.51 0.25] NOTES .30 [ 7.6 ] .60 [ 15.2 ] PIN DESIGNATIONS 1) Applied torque per screw should not exceed 5in-lb. (3in-lb recommended). 2) Baseplate flatness tolerance is 0.01” (.2mm) TIR for surface. 3) Pins 1-3, 5-7 are 0.040” (1.02mm) diameter, with 0.080” (2.03mm) diameter standoff shoulders. 4) Pins 4 and 8 are 0.062” (1.57 mm) diameter with 0.100" (2.54 mm) diameter standoff shoulders. 5) All Pins: Material - Copper Alloy, Finish (RoHS 6/6) - Matte Tin over Nickel plate 6) Total Weight: 3.12 oz (88.5 g) 7) All dimensions in inches (mm) Tolerances: x.xx +/-0.02 in. (x.x +/-0.5mm) x.xxx +/-0.010 in. (x.xx +/-0.25mm) 8) Workmanship: Meets or exceeds IPC-A-610 Class II 9) Recommended pin length is 0.03” (0.76mm) greater than the PCB thickness. 10) A thermal interface material is required to assure proper heat transfer from the flanged baseplate to the cooling surface. Thermal grease may be used, or materials such as Thermalloy’s Grafoil or Bergquist HiFlow and Softflow. Other similar products are available from many heatsink manufacturers. Product # IQ64xxxQTXxxx 2 Phone 1-888-567-9596 www.synqor.com Pin Name Function 1 Vin(+) Positive input voltage 2 ON/OFF 3 Vin(–) 4 Vout(–) TTL input to turn converter on and off, referenced to Vin(–), with internal pull up. Negative input voltage Negative output voltage 6 SENSE(–) Negative remote sense1 TRIM Output voltage trim2 7 SENSE(+) Positive remote sense3 5 8 Vout(+) Positive output voltage Notes: 1) SENSE(–) should be connected to Vout(–) either remotely or at the converter. 2) Leave TRIM pin open for nominal output voltage. 3) SENSE(+) should be connected to Vout(+) either remotely or at the converter. Doc.# 005-0005096 Rev. E 11/27/13 Page 28 Technical Specification IQ64xxxQTXxxx PART NUMBERING SYSTEM ORDERING INFORMATION The part numbering system for SynQor’s dc-dc converters follows the format shown in the example below. The tables below show the valid model numbers and ordering options for converters in this product family. When ordering SynQor converters, please ensure that you use the complete 15 character part number consisting of the 12 character base part number and the additional characters for options. InQor units are only available with 6/6 RoHS compliance indicated by "-G". IQ 6 4 0 1 8 Q T C 3 6 N R S - G IQ64018QTw36xyz IQ64033QTw27xyz IQ64050QTw20xyz IQ64070QTw14xyz IQ64120QTw08xyz IQ64150QTw07xyz IQ64240QTw04xyz IQ64300QTw03xyz IQ64480QTw02xyz Options (see Ordering Information) Output Current Thermal Design Performance Level Package Size Output Voltage Input Voltage Product Family The first 12 characters comprise the base part number and the last 3 characters indicate available options. The “-G” suffix indicates 6/6 RoHS compliance. Input Voltage 64V 64V 64V 64V 64V 64V 64V 64V 64V Model Number 6/6 RoHS Max Output Current 36.0A 27.0A 20.0A 14.0A 8.0A 6.5A 4.0A 3.2A 2.0A The following options must be included in place of the w x y z spaces in the model numbers listed above. Thermal Design w Options Description Enable Logic Pin Style x y C - Encased V - Encased with Flanged Baseplate Application Notes Output Voltage 1.8V 3.3V 5.0V 7.0V 12.0V 15.0V 24.0V 30.0V 48.0V N - Negative Feature Set z R - 0.180" S - Standard A variety of application notes and technical white papers can be downloaded in pdf format from our website. RoHS Compliance: The EU led RoHS (Restriction of Hazardous Substances) Directive bans the use of Lead, Cadmium, Hexavalent Chromium, Mercury, Polybrominated Biphenyls (PBB), and Polybrominated Diphenyl Ether (PBDE) in Electrical and Electronic Equipment. This SynQor product is 6/6 RoHS compliant. For more information please refer to SynQor’s RoHS addendum available at our RoHS Compliance / Lead Free Initiative web page or e-mail us at [email protected]. Not all combinations make valid part numbers, please contact SynQor for availability. PATENTS SynQor holds the following U.S. patents, one or more of which apply to each product listed in this document. Additional patent applications may be pending or filed in the future. Contact SynQor for further information and to order: Phone: Toll Free: Fax: E-mail: Web: Address: Product # IQ64xxxQTXxxx 978-849-0600 888-567-9596 978-849-0602 [email protected] www.synqor.com 155 Swanson Road Boxborough, MA 01719 USA Phone 1-888-567-9596 5,999,417 6,222,742 6,545,890 6,577,109 6,594,159 6,731,520 6,894,468 6,896,526 6,927,987 7,050,309 7,072,190 7,085,146 7,119,524 7,269,034 7,272,021 7,272,023 7,558,083 7,564,702 7,765,687 7,787,261 8,023,290 8,149,597 8,493,751 Warranty SynQor offers a two (2) year limited warranty. Complete warranty information is listed on our website or is available upon request from SynQor. Information furnished by SynQor is believed to be accurate and reliable. However, no responsibility is assumed by SynQor for its use, nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of SynQor. www.synqor.com Doc.# 005-0005096 Rev. E 11/27/13 Page 29