Specification Sheet

RAILWAY CONVERTERS
PB315 Series
6 2 6 W AT T S R O L L I N G S T O C K H E A D L I G H T C O N T R O L L E R
FEATURES
•
•
•
•
•
Designed to control two locomotive sealed beam
headlights, Type GE350PAR56/SP-75.
Meets EN50155 for operating conditions and EN50121 for
EMC / EMI.
High temp operation without additional heatsinking.
Ruggedised mechanically for shock and vibration. Input
protection against spikes, bursts & high ripple.
No vent holes, PCB conformal coated. Protection against
dust / moisture.
SPECIFICATIONS
INPUT
Input voltage
72Vin (45-101Vdc) or 110Vin (66-154Vdc)
Input current
16A at 72Vin, 12A at 110Vin
Inrush Current
16A at 72Vin, 25A at 110Vin
DC ripple factor
15%
Pollution protection
PD3 as per IEC60077-1
Ingress protection
Rated inpulse
withstand volts
IP40 as per AS1939
Input 2.5kV, Output 0.8kV as per
IEC60077-1
CONTROLS AND ALARMS
High/low beam
OUTPUT
Voltage
Continuous power
High beam = 68Vdc, Low beam 72Vin = 32Vdc,
Low beam 110Vin = 25Vdc
High beam = 9.2A, Low beam 72Vin = 6.6A, Low
Low beam 110Vin = 6.0A
626W max
Ripple voltage
200mV p-p
Line regulation
0.5% at full load
Load regulation
1.5% from 0 to full load
Current
On/Off
(for 110Vin only)
Headlight Fail
MECHANICAL
Enclosure
Chassis Mount Aluminium
Dimensions
322L x 150W x 102H including heatsink
Weight
4.0 kg
Terminations
Screw Terminals as standard. Other
terminals such as Cage Clamp, Fastons
available on request
OPERATING SPECIFICATIONS
Efficiency
93% at full load typical
Power dissipated
50W at full load typical
Isolation
Input to Chassis - 2400Vdc
Input to Output – 3800Vdc
Output to Chassis – 750Vdc
Up to 50C ambient at full load.
Derate linearly from 50C full load
to 80C zero load
Natural convection. No additional
cold plate or heatsinking required
Temperature
Cooling
High beam for control signal < 20Vdc
Low beam for 20Vdc < control signal < 154Vdc
Unit disabled for control signal < 20Vdc
Unit enabled for 20V < control signal < 154Vdc
Volt free contact closes under failure conditions
STANDARDS
Safety
Meets IEC60077-1, AS/NZS 60950-2000
EMC / EMI
Electrical service
conditions
Meets EN50121-3-2:2000 and EN50155
Meets EN50155
PROTECTION
472
Input reverse polarity
Indefinite. Series diode on input
High input ripple
Input overvoltage
Output overcurrent
Indefinate. Series diode on input
Approx 108Vdc for 72Vin, 168Vdc for 110Vin,
Auto Recovery
115% of nominal. Auto recovery
Output short circuit
Indefinite. Auto recovery
Output overvoltage
125% nominal, Input cycled off & on to reset
Over temperature
105C internal temperature. Auto restart
Doc. No. PBC9 Rev.C 28-4-11