FEATURES
•
•
•
•
•
•
Designed from the ground up specifically for Rolling Stock.
High temp operation without additional heatsinking. No
additional cold plate necessary.
Protection functions (excluding output overvoltage) auto reset,
unit restarts once fault is removed.
No vent holes, conformal coating of PCB. High degree of
protection against dust / moisture / pollution ingress.
Ruggedised mechanically for shock and vibration. Input
protection against, spikes, bursts and high ripple.
Meets EN50155 operating conditions, EN50121 for EMC / EMI.
SPECIFICATIONS
INPUT
Input voltage
45-154Vdc
Input current
15A
Inrush Current
25A at 110Vdc input
DC ripple factor
15%
24Vdc
Current
20.8A
Continuous power
500W
Ripple voltage
100mV p-p
Line regulation
0.5% at full load
Load regulation
1.5% from 0 to full load
Efficiency
90% at full load
Power dissipated
55W at full load
Isolation
Input to Chassis - 2121Vdc
Input to Output - 4242Vdc
Output to Chassis - 707Vdc
Up to 50C ambient at full load. Derate linearly
from 50C full load to 80C zero load
5 to 90% Non Condensing
Natural convection. No additional cold plate or
heatsinking required.
Relative humidity
Cooling
IP40 as per AS1939
Input 2.5kV, Output 0.8kV as per
IEC60077-1
Enclosure
Chassis Mount Aluminium
Dimensions
322L x 150W x 102H including heatsink
Weight
4.0 kg
Terminations
Screw Terminals as standard. Other
terminals such as Cage Clamp, Fastons
available on request
STANDARDS
OPERATING SPECIFICATIONS
Temperature
PD3 as per IEC60077-1
Ingress protection
Rated inpulse
Withstand volts
MECHANICAL
OUTPUT
Voltage
Pollution protection
RAILWAY CONVERTERS
5 0 0 W AT T S R O L L I N G S T O C K D C / D C C O N V E R T E R
Safety
Meets IEC60077-1, AS/NZS 60950-2000
EMC / EMI
Electrical service
conditions
Meets EN50121-3-2:2000 and EN50155
Meets EN50155
PROTECTION
Input reverse polarity
Indefinate. Series diode on input.
High input ripple
Indefinate. Series diode on input.
Input overvoltage
Approx 160Vdc, Auto recovery.
Output overcurrent
120% of nominal. Auto recovery.
Output short circuit
Indefinite. Auto recovery
Output overvoltage
130% nominal. Input cycled off and on to reset.
Over temperature
110C internal temperature. Auto restart.
Doc. No. PBC9 Rev.C 28-4-11