ICPTest_441_ 2 6_Amp_Rating_ _Ag _v1 pdf

ICP Test Report Certification Packet
Company name :
Littelfuse, Inc.
Product Series:
Ceramic Chip Fuse 0603
Product #:
441 Series (2-6 Amp - Silver)
Issue Date:
July 13, 2011
It is hereby certified by Littelfuse, Inc. that there is neither RoHS (EU Directive
2002/95/EC)-restricted substance nor such use, for materials to be used for unit parts, for
packing/packaging materials, and for additives and the like in the manufacturing processes.
In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used
for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing
processes, are all composed of the following components.
Issued by:
<Global EHS Engineer>
(1) Parts, sub-materials and unit parts
This document covers the Ceramic Chip Fuse 0603 RoHS-Compliant series products
manufactured by Littelfuse, Inc.
< Raw Materials Used
Please see Table 1
(2) The ICP data on all measurable substances
Please see appropriate pages as identifed in Table 1
Remarks:
Form 585-047 Rev. A
1
2/21/06
Table 1: List of Raw Materials covered by this report
Total Parts
1
2
3
4
5
6
7
Raw Material Part Number
039642
011003
011004
011001
011006
010118
010119
Raw Material Description
Body - Ceramic Substrate
Cover Glass - Overglaze Paste
Underglaze - Dielectric Paste
Termination – Ag End Paste
Element/Leads – Silver Conductor Paste
Plating - Nickel Anode
Plating - Tin Anode
2
Page(s)
3-8
9-14
15-21
22-28
29-35
36-40
41-45
Test Report
Applicant:
Number : TWNC00177046
Littelfuse, Philippines Inc.
LIMA Technology Center, Lipa City,
Malvar, Batangas
Date
: Oct 08, 2010
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: Ceramic Substrate
Part Number
: 039642
Date Sample Received
: Oct 05, 2010
Date Test Started
: Oct 05, 2010
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
This report shall not be reproduced
except in full, without the written
approval of the laboratory.
Page 1 Of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00177046
Test Conducted
(Ⅰ) Test Result Summary :
Testing Item
Result (ppm)
White Material
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content
Polybrominated Biphenyls (PBBs)
Monobrominated Biphenyls (MonoBB)
Dibrominated Biphenyls (DiBB)
Tribrominated Biphenyls (TriBB)
Tetrabrominated Biphenyls (TetraBB)
Pentabrominated Biphenyls (PentaBB)
Hexabrominated Biphenyls (HexaBB)
Heptabrominated Biphenyls (HeptaBB)
Octabrominated Biphenyls (OctaBB)
Nonabrominated Biphenyls (NonaBB)
Decabrominated Biphenyl (DecaBB)
Polybrominated Diphenyl Ethers (PBDEs)
Monobrominated Diphenyl Ethers (MonoBDE)
Dibrominated Diphenyl Ethers (DiBDE)
Tribrominated Diphenyl Ethers (TriBDE)
Tetrabrominated Diphenyl Ethers (TetraBDE)
Pentabrominated Diphenyl Ethers (PentaBDE)
Hexabrominated Diphenyl Ethers (HexaBDE)
Heptabrominated Diphenyl Ethers (HeptaBDE)
Octabrominated Diphenyl Ethers (OctaBDE)
Nonabrominated Diphenyl Ethers (NonaBDE)
Decabrominated Diphenyl Ether (DecaBDE)
Halogen Content
Fluorine (F)
Chlorine (Cl)
Bromine (Br)
Iodine (I)
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
Remarks: ppm = Parts per million based on weight of tested sample = mg/kg
ND = Not detected
Responsibility Of Chemist : Irene Chiou / Kevin Liu / Cathy Chen
Date Sample Received
Testing Period
: Oct 05, 2010
: Oct 05, 2010 To Oct 07, 2010
Page 2 Of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00177046
Test Conducted
(Ⅱ) RoHS Requirement:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Polybrominated Biphenyls (PBBs)
Polybrominated Diphenyl Ehters (PBDEs)
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for
homogeneous material.
(Ⅲ) Test Method:
Testing Item
Cadmium (Cd)
content
Lead (Pb) content
Mercury (Hg)
content
Chromium VI (Cr6+)
content
Polybrominated
Biphenyls (PBBs)
Polybrominated
Diphenyl Ethers
(PBDEs)
Halogen Content
Testing Method
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 7, by microwave
digestion until the tested samples are
totally dissolved and determined by
ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in annex C, by alkaline
digestion and determined by UV-Vis
spectrophotometer.
With reference to IEC 62321 edition
1.0:2008 in annex A, by solvent
extraction and determined by GC-MSD
and further HPLC confirmation when
necessary.
With reference to IEC 62321 edition
1.0:2008 in annex A, by solvent
extraction and determined by GC-MSD
and further HPLC confirmation when
necessary.
With reference to EN 14582:2007 by
calorimetric bomb with oxygen and
determined by ion chromatography
Reporting Limit
2 ppm
2 ppm
2 ppm
1 ppm
5 ppm
5 ppm
50 ppm
Remark: Reporting limit = Quantitation limit of analyte in sample
Page 3 Of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00177046
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents
Reference Standard: IEC 62321 edition 1.0:2008
Sampling/grinding or cutting
Cd/Pb/Hg
Cr
Weigh sample and
add organic solvent
By spot test
Negative
Confirm the tested
samples are
totally dissolved
Make up with
deionized water
PBBs/PBDEs
Polymers /
electronics
Metal
For different
material, digest
the sample with
*1
appropriate acid
6+
Get 50cm2 sample
By boiling water
extraction
*2
Weigh sample
and add
alkaline
solution
By Soxhlet
extraction or
Solvent extraction
Definite temp.
extraction
Cool and filter
the extract
Concentrate the
extract and make up
with organic
solvent
Analyzed by ICP-OES
Analyzed by GC-MSD
Make up with deionized
water and add diphenylcarbazide solution
Remarks:
*1: List Of Appropriate Acid:
Material
Polymers
Metals
Electronics
Analyzed by UV-VIS
Acid Added For Digestion
HNO3,HCl,HF,H2O2,H3BO3
HNO3,HCl,HF
HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected.
Page 4 Of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00177046
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Halogen Content
Reference Standard: EN 14582
Sampling/grinding or
cutting
Add absorbent in a
calorimetric bomb &
place weighed sample in
equipment
Fill the calorimetric
bomb with oxygen
Ignite then leave the
flask at room
temperature
Transfer the absorbent
into a volumetric flask
Make up with deionized
water
Analyzed by ion
chromatography
End Of Report
Page 5 Of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00177046
Test Conducted
Photo
Page 6 Of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Test Report
Applicant:
Number : TWNC00182415
Littelfuse, Philippines Inc.
LIMA Technology Center, Lipa City,
Malvar, Batangas
Date
: Nov 22, 2010
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: Coverglass Paste
Part Number
: 011003
Date Sample Received
: Nov 16, 2010
Date Test Started
: Nov 17, 2010
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
This report shall not be reproduced
except in full, without the written
approval of the laboratory.
Page 1 Of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00182415
Test Conducted
(Ⅰ) Test Result Summary :
Testing Item
Result (ppm)
Light Green Paste
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content
Polybrominated Biphenyls (PBBs)
Monobrominated Biphenyls (MonoBB)
Dibrominated Biphenyls (DiBB)
Tribrominated Biphenyls (TriBB)
Tetrabrominated Biphenyls (TetraBB)
Pentabrominated Biphenyls (PentaBB)
Hexabrominated Biphenyls (HexaBB)
Heptabrominated Biphenyls (HeptaBB)
Octabrominated Biphenyls (OctaBB)
Nonabrominated Biphenyls (NonaBB)
Decabrominated Biphenyl (DecaBB)
Polybrominated Diphenyl Ethers (PBDEs)
Monobrominated Diphenyl Ethers (MonoBDE)
Dibrominated Diphenyl Ethers (DiBDE)
Tribrominated Diphenyl Ethers (TriBDE)
Tetrabrominated Diphenyl Ethers (TetraBDE)
Pentabrominated Diphenyl Ethers (PentaBDE)
Hexabrominated Diphenyl Ethers (HexaBDE)
Heptabrominated Diphenyl Ethers (HeptaBDE)
Octabrominated Diphenyl Ethers (OctaBDE)
Nonabrominated Diphenyl Ethers (NonaBDE)
Decabrominated Diphenyl Ether (DecaBDE)
Halogen Content
Fluorine (F)
Chlorine (Cl)
Bromine (Br)
Iodine (I)
ND
27
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
Remarks: ppm = Parts per million based on wet weight of tested sample =
mg/kg
ND = Not detected
Responsibility Of Chemist : Irene Chiou / Kevin Liu / Cathy Chen
Date Sample Received
Testing Period
: Nov 16, 2010
: Nov 17, 2010 To Nov 22, 2010
Page 2 Of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00182415
Test Conducted
(Ⅱ) RoHS Requirement:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Polybrominated Biphenyls (PBBs)
Polybrominated Diphenyl Ehters (PBDEs)
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for
homogeneous material.
(Ⅲ) Test Method:
Testing Item
Cadmium (Cd)
content
Lead (Pb) content
Mercury (Hg)
content
Chromium VI (Cr6+)
content
Polybrominated
Biphenyls (PBBs)
Polybrominated
Diphenyl Ethers
(PBDEs)
Halogen Content
Testing Method
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 7, by microwave
digestion until the tested samples are
totally dissolved and determined by
ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in annex C, by alkaline
digestion and determined by UV-Vis
spectrophotometer.
With reference to IEC 62321 edition
1.0:2008 in annex A, by solvent
extraction and determined by GC-MSD
and further HPLC confirmation when
necessary.
With reference to IEC 62321 edition
1.0:2008 in annex A, by solvent
extraction and determined by GC-MSD
and further HPLC confirmation when
necessary.
With reference to EN 14582:2007 by
calorimetric bomb with oxygen and
determined by ion chromatography
Reporting Limit
2 ppm
2 ppm
2 ppm
1 ppm
5 ppm
5 ppm
50 ppm
Remark: Reporting limit = Quantitation limit of analyte in sample
Page 3 Of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00182415
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents
Reference Standard: IEC 62321 edition 1.0:2008
Sampling/grinding or cutting
Cd/Pb/Hg
Cr
Confirm the tested
samples are
totally dissolved
Make up with
deionized water
PBBs/PBDEs
Polymers /
electronics
Metal
For different
material, digest
the sample with
*1
appropriate acid
6+
Weigh sample and
add organic solvent
By spot test
Negative
Get 50cm2 sample
By boiling water
extraction
*2
Weigh sample
and add
alkaline
solution
By Soxhlet
extraction or
Solvent extraction
Definite temp.
extraction
Cool and filter
the extract
Analyzed by ICP-OES
Concentrate the
extract and make up
with organic
solvent
Analyzed by GC-MSD
Make up with deionized
water and add diphenylcarbazide solution
Remarks:
*1: List Of Appropriate Acid:
Material
Polymers
Metals
Electronics
Analyzed by UV-VIS
Acid Added For Digestion
HNO3,HCl,HF,H2O2,H3BO3
HNO3,HCl,HF
HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected.
Page 4 Of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00182415
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Halogen Content
Reference Standard: EN 14582
Sampling/grinding or
cutting
Add absorbent in a
calorimetric bomb &
place weighed sample in
equipment
Fill the calorimetric
bomb with oxygen
Ignite then leave the
flask at room
temperature
Transfer the absorbent
into a volumetric flask
Make up with deionized
water
Analyzed by ion
chromatography
End Of Report
Page 5 Of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00182415
Test Conducted
Photo
Page 6 Of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Test Report
Applicant:
Number : TWNC00215224
Littelfuse Philippines Inc.
LIMA Technology Center, Lipa City,
Malvar, Batangas
Date
: Jul 12, 2011
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: Sintered (Underglaze Paste) Dielectric Paste
Part Number
: 011004
Date Sample Received
: Jul 07, 2011
Date Test Started
: Jul 07, 2011
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
This report shall not be reproduced
except in full, without the written
approval of the laboratory.
Page 1 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00215224
Test Conducted
(Ⅰ) Test Result Summary :
Test Item
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content
Polybrominated Biphenyls (PBBs)
Monobrominated Biphenyls (MonoBB)
Dibrominated Biphenyls (DiBB)
Tribrominated Biphenyls (TriBB)
Tetrabrominated Biphenyls (TetraBB)
Pentabrominated Biphenyls (PentaBB)
Hexabrominated Biphenyls (HexaBB)
Heptabrominated Biphenyls (HeptaBB)
Octabrominated Biphenyls (OctaBB)
Nonabrominated Biphenyls (NonaBB)
Decabrominated Biphenyl (DecaBB)
Polybrominated Diphenyl Ethers (PBDEs)
Monobrominated Diphenyl Ethers (MonoBDE)
Dibrominated Diphenyl Ethers (DiBDE)
Tribrominated Diphenyl Ethers (TriBDE)
Tetrabrominated Diphenyl Ethers (TetraBDE)
Pentabrominated Diphenyl Ethers (PentaBDE)
Hexabrominated Diphenyl Ethers (HexaBDE)
Heptabrominated Diphenyl Ethers (HeptaBDE)
Octabrominated Diphenyl Ethers (OctaBDE)
Nonabrominated Diphenyl Ethers (NonaBDE)
Decabrominated Diphenyl Ether (DecaBDE)
Result (ppm)
White/Blue Material
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
Page 2 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00215224
Test Conducted
(Ⅰ) Test Result Summary :
Test Item
Result (ppm)
White/Blue Material
Halogen Content
Fluorine (F)
Chlorine (Cl)
Bromine (Br)
Iodine (I)
ND
ND
ND
ND
Remarks: ppm = Parts per million based on weight of tested sample = mg/kg
ND = Not detected
Responsibility Of Chemist : Irene Chiou / Kevin Liu / Cathy Chen
Date Sample Received
Test Period
: Jul 07, 2011
: Jul 07, 2011 To Jul 11, 2011
(Ⅱ) RoHS Requirement:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Polybrominated Biphenyls (PBBs)
Polybrominated Diphenyl Ehters (PBDEs)
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for
homogeneous material.
Page 3 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00215224
Test Conducted
(Ⅲ) Test Method:
Test Item
Cadmium (Cd)
content
Lead (Pb) content
Mercury (Hg)
content
Chromium VI (Cr6+)
content
Polybrominated
Biphenyls (PBBs)
Polybrominated
Diphenyl Ethers
(PBDEs)
Halogen Content
Test Method
Reporting Limit
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
2 ppm
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
2 ppm
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 7, by microwave
digestion until the tested samples are
2 ppm
totally dissolved and determined by
ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in annex C, by alkaline
1 ppm
digestion and determined by UV-Vis
spectrophotometer.
With reference to IEC 62321 edition
1.0:2008 in annex A, by solvent
extraction and determined by GC-MSD
5 ppm
and further HPLC confirmation when
necessary.
With reference to IEC 62321 edition
1.0:2008 in annex A, by solvent
extraction and determined by GC-MSD
5 ppm
and further HPLC confirmation when
necessary.
With reference to EN 14582:2007 by
calorimetric bomb with oxygen and
50 ppm
determined by ion chromatography
Remark: Reporting limit = Quantitation limit of analyte in sample
Page 4 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00215224
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents
Reference Standard: IEC 62321 edition 1.0:2008
Sample preparation
For non-metal part
For metal part
Take sample and immerse into Aqua Regia, start to strip plating layer
Stop the stripping procedure upon color change completely
Take the Aqua solution as plating component and stripped body as substrate component
Cd/Pb/Hg
Cr
Weigh sample and
add organic solvent
By spot test
Negative
Confirm the tested
samples are
totally dissolved
Make up with
deionized water
PBBs/PBDEs
Polymers /
electronics
Metal
For different
material, digest
the sample with
*1
appropriate acid
6+
Get 50cm2 sample
By boiling water
extraction
*2
Weigh sample
and add
alkaline
solution
By Soxhlet
extraction or
Solvent extraction
Definite temp.
extraction
Cool and filter
the extract
Analyzed by ICP-OES
Concentrate the
extract and make up
with organic
solvent
Analyzed by GC-MSD
Make up with deionized
water and add diphenylcarbazide solution
Analyzed by UV-VIS
Remarks:
*1: List Of Appropriate Acid:
Acid Added For Digestion
Material
Polymers
HNO3,HCl,HF,H2O2,H3BO3
Metals
HNO3,HCl,HF
Electronics
HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected.
Page 5 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00215224
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Halogen Content
Reference Standard:EN 14582
Sampling/grinding or
cutting
Add absorbent in a
combustion flask &
place weighed sample in
equipment
Fill oxygen into
calorimetric bomb
Ignite then leave the
flask at room
temperature
Transfer the absorbent
into a volumetric flask
Make up with deionized
water
Analyzed by ion
chromatography
End Of Report
Page 6 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00215224
Test Conducted
Photo
Page 7 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Test Report
Applicant:
Number : TWNC00182419
Littelfuse, Philippines Inc.
LIMA Technology Center, Lipa City,
Malvar, Batangas
Date
: Nov 22, 2010
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: End Termination Paste
Part Number
: 011001
Date Sample Received
: Nov 16, 2010
Date Test Started
: Nov 17, 2010
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
This report shall not be reproduced
except in full, without the written
approval of the laboratory.
Page 1 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00182419
Test Conducted
(Ⅰ) Test Result Summary :
Testing Item
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content
Polybrominated Biphenyls (PBBs)
Monobrominated Biphenyls (MonoBB)
Dibrominated Biphenyls (DiBB)
Tribrominated Biphenyls (TriBB)
Tetrabrominated Biphenyls (TetraBB)
Pentabrominated Biphenyls (PentaBB)
Hexabrominated Biphenyls (HexaBB)
Heptabrominated Biphenyls (HeptaBB)
Octabrominated Biphenyls (OctaBB)
Nonabrominated Biphenyls (NonaBB)
Decabrominated Biphenyl (DecaBB)
Polybrominated Diphenyl Ethers (PBDEs)
Monobrominated Diphenyl Ethers (MonoBDE)
Dibrominated Diphenyl Ethers (DiBDE)
Tribrominated Diphenyl Ethers (TriBDE)
Tetrabrominated Diphenyl Ethers (TetraBDE)
Pentabrominated Diphenyl Ethers (PentaBDE)
Hexabrominated Diphenyl Ethers (HexaBDE)
Heptabrominated Diphenyl Ethers (HeptaBDE)
Octabrominated Diphenyl Ethers (OctaBDE)
Nonabrominated Diphenyl Ethers (NonaBDE)
Decabrominated Diphenyl Ether (DecaBDE)
Result (ppm)
Grey Paste
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
Page 2 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00182419
Test Conducted
(Ⅰ) Test Result Summary :
Testing Item
Result (ppm)
Grey Paste
Halogen Content
Fluorine (F)
Chlorine (Cl)
Bromine (Br)
Iodine (I)
ND
ND
ND
ND
Remarks: ppm = Parts per million based on wet weight of tested sample =
mg/kg
ND = Not detected
Responsibility Of Chemist : Irene Chiou / Kevin Liu / Cathy Chen
Date Sample Received
Testing Period
: Nov 16, 2010
: Nov 17, 2010 To Nov 19, 2010
(Ⅱ) RoHS Requirement:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Polybrominated Biphenyls (PBBs)
Polybrominated Diphenyl Ehters (PBDEs)
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for
homogeneous material.
Page 3 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00182419
Test Conducted
(Ⅲ) Test Method:
Testing Item
Cadmium (Cd)
content
Lead (Pb) content
Mercury (Hg)
content
Chromium VI (Cr6+)
content
Polybrominated
Biphenyls (PBBs)
Polybrominated
Diphenyl Ethers
(PBDEs)
Halogen Content
Testing Method
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 7, by microwave
digestion until the tested samples are
totally dissolved and determined by
ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in annex C, by alkaline
digestion and determined by UV-Vis
spectrophotometer.
With reference to IEC 62321 edition
1.0:2008 in annex A, by solvent
extraction and determined by GC-MSD
and further HPLC confirmation when
necessary.
With reference to IEC 62321 edition
1.0:2008 in annex A, by solvent
extraction and determined by GC-MSD
and further HPLC confirmation when
necessary.
With reference to EN 14582:2007 by
calorimetric bomb with oxygen and
determined by ion chromatography
Reporting Limit
2 ppm
2 ppm
2 ppm
1 ppm
5 ppm
5 ppm
50 ppm
Remark: Reporting limit = Quantitation limit of analyte in sample
Page 4 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00182419
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents
Reference Standard: IEC 62321 edition 1.0:2008
Sampling/grinding or cutting
Cd/Pb/Hg
Cr
Weigh sample and
add organic solvent
By spot test
Negative
Confirm the tested
samples are
totally dissolved
Make up with
deionized water
PBBs/PBDEs
Polymers /
electronics
Metal
For different
material, digest
the sample with
*1
appropriate acid
6+
Get 50cm2 sample
By boiling water
extraction
*2
Weigh sample
and add
alkaline
solution
By Soxhlet
extraction or
Solvent extraction
Definite temp.
extraction
Cool and filter
the extract
Concentrate the
extract and make up
with organic
solvent
Analyzed by ICP-OES
Analyzed by GC-MSD
Make up with deionized
water and add diphenylcarbazide solution
Analyzed by UV-VIS
Remarks:
*1: List Of Appropriate Acid:
Material
Polymers
Metals
Electronics
Acid Added For Digestion
HNO3,HCl,HF,H2O2,H3BO3
HNO3,HCl,HF
HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected.
Page 5 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00182419
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Halogen Content
Reference Standard: EN 14582
Sampling/grinding or
cutting
Add absorbent in a
calorimetric bomb &
place weighed sample in
equipment
Fill the calorimetric
bomb with oxygen
Ignite then leave the
flask at room
temperature
Transfer the absorbent
into a volumetric flask
Make up with deionized
water
Analyzed by ion
chromatography
End Of Report
Page 6 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00182419
Test Conducted
Photo
Page 7 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Test Report
Applicant:
Number : TWNC00182418
Littelfuse, Philippines Inc.
LIMA Technology Center, Lipa City,
Malvar, Batangas
Date
: Nov 22, 2010
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: Silver (Ag) Conductor Paste
Part Number
: 011006
Date Sample Received
: Nov 16, 2010
Date Test Started
: Nov 17, 2010
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
This report shall not be reproduced
except in full, without the written
approval of the laboratory.
Page 1 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00182418
Test Conducted
(Ⅰ) Test Result Summary :
Testing Item
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content
Polybrominated Biphenyls (PBBs)
Monobrominated Biphenyls (MonoBB)
Dibrominated Biphenyls (DiBB)
Tribrominated Biphenyls (TriBB)
Tetrabrominated Biphenyls (TetraBB)
Pentabrominated Biphenyls (PentaBB)
Hexabrominated Biphenyls (HexaBB)
Heptabrominated Biphenyls (HeptaBB)
Octabrominated Biphenyls (OctaBB)
Nonabrominated Biphenyls (NonaBB)
Decabrominated Biphenyl (DecaBB)
Polybrominated Diphenyl Ethers (PBDEs)
Monobrominated Diphenyl Ethers (MonoBDE)
Dibrominated Diphenyl Ethers (DiBDE)
Tribrominated Diphenyl Ethers (TriBDE)
Tetrabrominated Diphenyl Ethers (TetraBDE)
Pentabrominated Diphenyl Ethers (PentaBDE)
Hexabrominated Diphenyl Ethers (HexaBDE)
Heptabrominated Diphenyl Ethers (HeptaBDE)
Octabrominated Diphenyl Ethers (OctaBDE)
Nonabrominated Diphenyl Ethers (NonaBDE)
Decabrominated Diphenyl Ether (DecaBDE)
Result (ppm)
Grey Paste
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
Page 2 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00182418
Test Conducted
(Ⅰ) Test Result Summary :
Testing Item
Result (ppm)
Grey Paste
Halogen Content
Fluorine (F)
Chlorine (Cl)
Bromine (Br)
Iodine (I)
ND
ND
ND
ND
Remarks: ppm = Parts per million based on wet weight of tested sample =
mg/kg
ND = Not detected
Responsibility Of Chemist : Irene Chiou / Kevin Liu / Cathy Chen
Date Sample Received
Testing Period
: Nov 16, 2010
: Nov 17, 2010 To Nov 19, 2010
(Ⅱ) RoHS Requirement:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Polybrominated Biphenyls (PBBs)
Polybrominated Diphenyl Ehters (PBDEs)
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for
homogeneous material.
Page 3 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00182418
Test Conducted
(Ⅲ) Test Method:
Testing Item
Cadmium (Cd)
content
Lead (Pb) content
Mercury (Hg)
content
Chromium VI (Cr6+)
content
Polybrominated
Biphenyls (PBBs)
Polybrominated
Diphenyl Ethers
(PBDEs)
Halogen Content
Testing Method
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 7, by microwave
digestion until the tested samples are
totally dissolved and determined by
ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in annex C, by alkaline
digestion and determined by UV-Vis
spectrophotometer.
With reference to IEC 62321 edition
1.0:2008 in annex A, by solvent
extraction and determined by GC-MSD
and further HPLC confirmation when
necessary.
With reference to IEC 62321 edition
1.0:2008 in annex A, by solvent
extraction and determined by GC-MSD
and further HPLC confirmation when
necessary.
With reference to EN 14582:2007 by
calorimetric bomb with oxygen and
determined by ion chromatography
Reporting Limit
2 ppm
2 ppm
2 ppm
1 ppm
5 ppm
5 ppm
50 ppm
Remark: Reporting limit = Quantitation limit of analyte in sample
Page 4 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00182418
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents
Reference Standard: IEC 62321 edition 1.0:2008
Sampling/grinding or cutting
Cd/Pb/Hg
Cr
Confirm the tested
samples are
totally dissolved
Make up with
deionized water
PBBs/PBDEs
Polymers /
electronics
Metal
For different
material, digest
the sample with
*1
appropriate acid
6+
Weigh sample and
add organic solvent
By spot test
Negative
Get 50cm2 sample
By boiling water
extraction
*2
Weigh sample
and add
alkaline
solution
By Soxhlet
extraction or
Solvent extraction
Definite temp.
extraction
Cool and filter
the extract
Analyzed by ICP-OES
Concentrate the
extract and make up
with organic
solvent
Analyzed by GC-MSD
Make up with deionized
water and add diphenylcarbazide solution
Analyzed by UV-VIS
Remarks:
*1: List Of Appropriate Acid:
Material
Polymers
Metals
Electronics
Acid Added For Digestion
HNO3,HCl,HF,H2O2,H3BO3
HNO3,HCl,HF
HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected.
Page 5 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00182418
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Halogen Content
Reference Standard: EN 14582
Sampling/grinding or
cutting
Add absorbent in a
calorimetric bomb &
place weighed sample in
equipment
Fill the calorimetric
bomb with oxygen
Ignite then leave the
flask at room
temperature
Transfer the absorbent
into a volumetric flask
Make up with deionized
water
Analyzed by ion
chromatography
End Of Report
Page 6 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00182418
Test Conducted
Photo
Page 7 Of 7
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Test Report
Applicant:
Number : TWNC00182567
Littelfuse, Philippines Inc.
LIMA Technology Center, Lipa
City,
Malvar, Batangas
Date
: Nov 19, 2010
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: Nickel (metal)
Part Number
: 010118
Date Sample Received
: Nov 17, 2010
Date Test Started
: Nov 17, 2010
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
This report shall not be reproduced
except in full, without the written
approval of the laboratory.
Page 1 Of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00182567
Test Conducted
(Ⅰ) Test Result Summary :
Testing Item
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content (mg/kg with 50cm2)
Result (ppm)
Silvery Metal
ND
ND
ND
Negative
(< 0.02)(#)
Remarks: ppm = Parts per million based on weight of tested sample = mg/kg
ND = Not detected
<
= Less than
mg/kg with 50cm2 = milligram per kilogram with 50 square centimetre
Negative = A negative test result indicated positive observation
was not found at the time of testing.
#
= Due to the insufficient sample area, reduced total sample
surface of 20 cm2 was used and the dilution factor was
adjusted accordingly.
Responsibility Of Chemist : Irene Chiou / Kevin Liu / Cathy Chen
Date Sample Received
Testing Period
: Nov 17, 2010
: Nov 17, 2010 to Nov 19, 2010
(Ⅱ) RoHS Requirement:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for
homogeneous material.
Page 2 Of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00182567
Test Conducted
(Ⅲ) Test Method:
Testing Item
Cadmium (Cd)
content
Lead (Pb) content
Mercury (Hg)
content
Chromium VI (Cr6+)
content
Testing Method
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 7, by microwave
digestion until the tested samples are
totally dissolved and determined by
ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in annex B, by boiling water
extraction and determined by UV-Vis
spectrophotometer.
Reporting Limit
2 ppm
2 ppm
2 ppm
0.02
mg/kg with 50cm2
Remark: Reporting limit = Quantitation limit of analyte in sample
Page 3 Of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00182567
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Cd/Pb/Hg/Chromium (VI)
Reference Standard:IEC 62321 edition 1.0:2008
Sampling/grinding or cutting
Cd/Pb/Hg
Cr
Polymers /
Electronics
Metal
For different
material, digest
the sample with
*1
appropriate acid
By spot test
Negative
Confirm the tested
samples are
totally dissolved
Make up with
deionized water
6+
*2
Weigh sample
and add
alkaline
solution
Get 50cm2 sample
Definite temp.
extraction
Boiling water
extraction
Cool and filter
the extract
Analyzed by ICP-OES
Make up with deionized
water and add diphenylcarbazide solution
Analyzed by UV-VIS
Remarks:
*1: List Of Appropriate Acid:
Acid Added For Digestion
Material
Polymers
HNO3,HCl,HF,H2O2,H3BO3
Metals
HNO3,HCl,HF
Electronics
HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected.
End Of Report
Page 4 Of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00182567
Test Conducted
Photo
Page 5 Of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Test Report
Applicant:
Number : TWNC00182568
Littelfuse, Philippines Inc.
LIMA Technology Center, Lipa City,
Malvar, Batangas
Date
: Nov 22, 2010
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: Tin (Sn) Anode (metal)
Part Number
: 010119
Date Sample Received
: Nov 17, 2010
Date Test Started
: Nov 17, 2010
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
This report shall not be reproduced
except in full, without the written
approval of the laboratory.
Page 1 Of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00182568
Test Conducted
Result (ppm)
Silvery Metal
Testing Item
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content (mg/kg with 50cm2)
ND
14
ND
Negative (< 0.02)(#)
Remarks: ppm = Parts per million based on weight of tested sample = mg/kg
ND = Not detected
<
= Less than
mg/kg with 50cm2 = milligram per kilogram with 50 square centimetre
Negative = A negative test result indicated positive observation
was not found at the time of testing.
#
= Due to the insufficient sample area, reduced total sample
surface of 20 cm2 was used and the dilution factor was
adjusted accordingly.
Responsibility Of Chemist : Irene Chiou / Kevin Liu / Cathy Chen
Date Sample Received
Testing Period
: Nov 17, 2010
: Nov 17, 2010 To Nov 22, 2010
(Ⅱ) RoHS Requirement:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for
homogeneous material.
Page 2 Of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00182568
Test Conducted
(Ⅲ) Test Method:
Testing Item
Cadmium (Cd)
content
Lead (Pb) content
Mercury (Hg)
content
Chromium VI (Cr6+)
content
Testing Method
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 7, by microwave
digestion until the tested samples are
totally dissolved and determined by
ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in annex B, by boiling water
extraction and determined by UV-Vis
spectrophotometer.
Reporting Limit
2 ppm
2 ppm
2 ppm
0.02
mg/kg with 50cm2
Remark: Reporting limit = Quantitation limit of analyte in sample
Page 3 Of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00182568
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Cd/Pb/Hg/Chromium (VI)
Reference Standard:IEC 62321 edition 1.0:2008
Sampling/grinding or cutting
Cd/Pb/Hg
Cr
Polymers /
Electronics
Metal
For different
material, digest
the sample with
*1
appropriate acid
By spot test
Negative
Confirm the tested
samples are
totally dissolved
Make up with
deionized water
6+
*2
Weigh sample
and add
alkaline
solution
Get 50cm2 sample
Definite temp.
extraction
Boiling water
extraction
Cool and filter
the extract
Analyzed by ICP-OES
Make up with deionized
water and add diphenylcarbazide solution
Remarks:
*1: List Of Appropriate Acid:
Material
Polymers
Metals
Electronics
Analyzed by UV-VIS
Acid Added For Digestion
HNO3,HCl,HF,H2O2,H3BO3
HNO3,HCl,HF
HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected.
End Of Report
Page 4 Of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00182568
Test Conducted
Photo
Page 5 Of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401