Axial Lead and Cartridge Fuses
Designed to IEC Standard
5 x 20 mm Fast-Acting Fuse 217/227 Series
D
®
®
V
E
• Designed to International (IEC) Standards for use globally.
• Meets the IEC 60127-2, Sheet 2 specification for Fast-Acting Fuses.
• Available in Cartridge and Axial Lead Form.
• Available in ratings of 0.032 to 10 amperes.
ELECTRICAL CHARACTERISTICS:
% of Ampere
Rating
150%
210%
275%
400%
1000%
Ampere
Rating
.032 – .100
.125 – 6.3
.032 – .100
.125 – 6.3
.032 – .100
.125 – 6.3
.032 – .100
.125 – 6.3
.032 – .100
.125 – 6.3
Opening
Time
60 minutes, Minimum
60 minutes, Minimum
30 minutes, Maximum
30 minutes, Maximum
0.01 sec., Min.; .5 sec. Max.
0.05 sec., Min.; 2 sec. Max.
.003 sec., Min.; 0.1 sec. Max.
.01 sec., Min.; 0.3 sec. Max.
.02 second, Maximum
.02 second, Maximum
217 000 XE
227 000 Series
217 000 Series
.635
(.025)
AGENCY APPROVALS: Sheet I IEC 60127-2:* SEMKO, VDE
ORDERING INFORMATION:
Axial Lead
Catalog
Number
227.032
227.040
227.050
227.063
227.080
227.100
227.125
227.160
227.200
227.250
227.315
227.400
227.500
227.630
227.800
227 001
227 1.25
227 01.6
227 002
227 02.5
227 3.15
227 004
227 005
227 06.3
227 008
227 010
Ampere
Rating
.032
.040
.050
.063
.080
.100
.125
.160
.200
.250
.315
.400
.500
.630
.800
1
1.25
1.6
2
2.5
3.15
4
5
6.3
8*
10*
Voltage
Rating
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
Nominal
Resistance
Cold Ohms
262.2
183.2
15.20
10.43
7.88
5.10
3.68
2.53
1.65
1.18
0.810
0.277
0.210
0.168
0.134
0.096
0.070
0.046
0.040
0.033
0.022
0.016
0.013
0.0098
0.0068
0.0060
Nominal
Melting I2t
A2 Sec.
0.000048
0.000074
0.00020
0.00057
0.00085
0.0034
0.0049
0.011
0.025
0.043
0.110
0.130
0.225
0.420
0.870
1.07
2.29
4.74
5.88
9.72
18.2
30.0
43.9
64.2
203.5
223.5
5.25
(.207)
22.5 MAX
(.886)
40
(1.58)
100
10
1
0.1
0.01
0.001
0.05 0.1
*IEC Standards for 5 x 20mm fuses do not include ratings above 6.3 amperes, but
are under consideration.
1
294
20
(.787)
Average Time Current Curves
TIME IN SECONDS
Cartridge
Catalog
Number
217.032
217.040
217.050
217.063
217.080
217.100
217.125
217.160
217.200
217.250
217.315
217.400
217.500
217.630
217.800
217 001
217 1.25
217 01.6
217 002
217 02.5
217 3.15
217 004
217 005
217 06.3
217 008
217 010
5
(.197)
.032A
.050A
.063A
.080A
.100A
.125A
.160A
.200A
.250A
.315A
.400A
.500A
.630A
.800A
1A
1.25A
1.6A
2A
2.5A
3.15A
4A
5A
6.3A
8A
approved thru 6.3 amps. BSI approved 0.4-6.3 amps.
Recognized under the Components Program of Underwriters
Laboratories and recognized by CSA.
UL recognized to 6.3A only.
INTERRUPTING RATING: 35 amperes or 10 x rated current;
whichever is greater.
1
1
10
CURRENT IN AMPERES
227 Series is used for North American ordering.
w w w. l i t t e l f u s e . c o m
100
500