Operating Notes Power Supply FCC Compliance Statement This dome camera can operate on 24 VAC or 12 VDC. Operating Conditions Avoid: • Viewing bright objects (for example, light fixtures) for extended periods • Operating or storing the unit in the following locations. • Extremely humid, dusty, hot/cold environments (where the operating temperature is outside the recommended range of 14°F to 122°F [-10°C to +50°C]) • Close to sources of powerful electromagnetic radiation, such as radio or TV transmitters • Close to fluorescent lamps or objects reflecting light • Under unstable light sources (may cause flickering) Warnings (where applicable to your locale) Quick Install Guide Information to the User: This equipment has been tested and found to comply with the limits for a Class B digital device. Pursuant to Part 15 of the FCC Rules, these limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: • • • • Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment to an outlet on a circuit different from that to which the receiver is connected Consult the dealer or a radio/TV technician for help. Installation and servicing should be performed only by qualified and experienced technicians to conform to all local codes and to maintain your warranty. Caution WARNING! This Class B digital apparatus complies with Canadian ICES-003. The use of CSA Certified/UL Listed Class 2 power adapters is required to ensure compliance with electrical safety standards. 3 Inch Dome Camera 1 Preparation 2 Camera Mounting Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. WEEE (Waste Electrical and Electronic Equipment). Correct disposal of this product (applicable in the European Union and other European countries with separate collection systems). This product should be disposed of, at the end of its useful life, as per applicable local laws, regulations, and procedures. Manufacturer’s Declaration of Conformance Product Dimensions Contact Information 3 Camera Adjustment 4 Installation Completion The manufacturer declares that the equipment supplied with this guide is compliant with the essential protection requirements of the EMC directive 89/336/EEC and the Low Voltage Directive LVD 73/23 EEC, conforming to the requirements of standards EN 55022 for emissions. Contents 0.9” (23.0 mm) 1.8” (46.0 mm) 4.17” (106.1 mm) 2.03” (51.75 mm) 3.37” (85.5 mm) 1.68” (42.8 mm) Fully assembled camera www.honeywellvideo.com +1.800.796.CCTV (North America only) [email protected] 4.9” (124.6 mm) Mounting template 1 2 Preparation 1. Remove the dome cover ∅ 3.97” (101 mm) 3.0” (76.2 mm) Camera Mounting Gently turn the dome cover counterclockwise to unlock, then pull free of the housing. b. Gently pull the inner liner free of the two notches in the housing. c. Set the dome and liner aside. Camera Adjustment a. Electrical box (not supplied) Adapter plate (optional) a. b. c. a. Adapter plate (optional). Secure to electrical box using appropriate screws (not supplied). b. Secure camera base to ceiling or wall. b. Axis ring Base After mounting and adjusting the camera, attach the dome cover: Document 800-00789 – Rev C – 07/08 3 4S Electrical Junction Box a. Zoom lever Focus lever Turn the Axis ring in the desired direction, then retighten. Turn the Zoom lever slightly counter-clockwise to loosen. Then rotate around the lens for the desired image view. c. Turn the Focus lever counterclockwise to loosen. Rotate to adjust for the best picture quality. d. Retighten the Zoom and Focus levers to lock them after making adjustments. Do not turn the lens more than 360°. Do not use excessive force to loosen the levers and axis ring. Attach the inner liner to the base until the liner clicks into place. Align the dome cover with the three dome tabs on the unit. Optional Camera Settings Turn the dome gently clockwise until it locks into place. Monitor out 2. Connect the wiring 4.9” (124.6 mm) Surface Mount Flush Mount Mode setting DIP switches Adapter plate (optional) 24 VAC/12 VDC power connector Video output connector 1 2 3 4 5 6 7 8 a. Connect the video output connector. b. Connect the 24 VAC/12 VDC power connector. Skirt Note Please use the supplied DC Iris and Line Lock adjustment tool to adjust picture brightness and phase adjustment. Picture Brightness Phase Adjustment 3. Prepare the mounting surface (surface or flush mount) © 2008 Honeywell International Inc. All rights reserved. No part of this publication may be reproduced by any means without written permission from Honeywell Video Systems. The information in this publication is believed to be accurate in all respects. However, Honeywell Video Systems cannot assume responsibility for any consequences resulting from the use thereof. The information contained herein is subject to change without notice. Revisions or new editions to this publication may be issued to incorporate such changes. DIP Switches Hardware kit Document 800-00789 – Rev C – 07/08 a. Adapter plate (optional for ceiling tile). Secure using appropriate screws (not supplied). b. Secure camera base with ______________ screws, supplied. Surface mount: Secure skirt to ceiling or wall using _______ screws supplied. a. Mark the holes. b. Insert screw anchors into holes. Use the LEVEL screw to compensate for the iris level. L (low) darkens t picture. H (high) brightens the picture. This guide Use the V Phase Adjustment Pot to adjust the phase difference betwe e cameras. Make sure Switch 4 is ON to activate the Line lock function ( A operation only). Switch Function 1 2 BLC (Backlight Compensation). ON = camera automatically adjusts the exposure. OFF = factory default. AGC (Automatic Gain Control). ON = camera adjusts for low light conditions. ON = factory default. 3 DC/AES Mode. Leave in ON position only. 4 LL (Line Lock). Set the camera synchronization to internal or Line lock (only available with 24 VAC). ON= factory default. 1 2 Preparation 1. Remove the Dome Cover Camera Adjustment 4S Electrical Junction Box a. b. Security screw 3 Camera Mounting c. Gently turn the dome cover counterclockwise to unlock, then pull free of the housing. If required, loosen the security screw first. Gently pull the inner liner free of the two notches in the housing. a. a. Attach the inner liner to the base until the liner clicks into place. b. Align the dome cover with the three dome tabs on the unit. c. Turn the dome gently clockwise until it locks into place. Secure the adapter plate to the electrical box using appropriate screws (not supplied). Adapter plate b. If necessary, tuck Video/Power and BNC cabling into notch. Screws (not supplied) c. Secure camera base to ceiling or wall with 3 screws, supplied. Set the dome and liner aside. After ➋ mounting and ➌ adjusting the camera, attach the dome cover: d. Electrical box (not supplied) Legend A = Tilt rotation B = Horizontal rotation* C = Pan rotation B C Base Notch * If necessary, loosen the screw that locks the gimbal assembly in place, before adjusting the camera. A Screws (supplied) Optional Camera Settings V-Phase Level H If desired, secure the dome to the base with the security screw (see picture). L + – Focus lever (top) 2. Prepare the Mounting Surface (Surface or Flush Mount) Surface Mount Monitor out Flush Mount Adapter plate Mode setting DIP switches Use camera base or mounting template to: a. b. 1 2 3 4 5 6 7 8 Mark the holes as required. Notch Skirt Base Insert screw anchors into holes. = ON = OFF Zoom lever (bottom) 3. Connect the Wiring Setscrew . Screws (not supplied) 24 VAC/12 VDC power connector M3 screws (not supplied) The LEVEL screw compensates for the iris level. L (low) darkens the picture. H (high) brightens the picture. Phase Adjustment The V Phase Adjustment Pot adjusts the phase difference between cameras. Switch 7 must be ON to activate Line lock (AC only). DIP Switches Base Video output connector Picture Brightness Notch a. Connect the video output connector. a. Surface mount: Secure skirt to ceiling or wall using appropriate screws, not supplied. b. Connect the 24 VAC/12 VDC power connector. b. If necessary, tuck Video/Power and BNC cabling into notch. c. M3 screws (supplied) Surface mount: Secure camera base with M3 screws, supplied. Flush mount: Secure camera base with appropriate M3 screws, not supplied. (Refer to your camera model) Default settings are shown in bold. SW High Res + TDN High Res Std Res 1 DC/AES DC/AES DC/AES 2 AWB/ATW AWB/ATW AWB/ATW 3 BLC ON/OFF BLC ON/OFF BLC ON/OFF 4 AGC ON/OFF AGC ON/OFF AGC ON/OFF 5 TDN Not used FLK 6 FLK ON/OFF FLK ON/OFF LL ON/OFF 7 LL ON/OFF LL ON/OFF Not available 8 Not used Not used Not available