X

Operating Notes
Power Supply
FCC Compliance Statement
This dome camera can operate on 24 VAC or 12 VDC.
Operating Conditions Avoid:
• Viewing bright objects (for example, light fixtures) for extended
periods
• Operating or storing the unit in the following locations.
• Extremely humid, dusty, hot/cold environments (where the
operating temperature is outside the recommended range of
14°F to 122°F [-10°C to +50°C])
• Close to sources of powerful electromagnetic radiation, such
as radio or TV transmitters
• Close to fluorescent lamps or objects reflecting light
• Under unstable light sources (may cause flickering)
Warnings (where applicable to your locale)
Quick Install Guide
Information to the User: This equipment has been tested and found to comply with the limits for a
Class B digital device. Pursuant to Part 15 of the FCC Rules, these limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance
with the instruction manual, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one of the following
measures:
•
•
•
•
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment to an outlet on a circuit different from that to which the receiver is
connected
Consult the dealer or a radio/TV technician for help.
Installation and servicing should be performed only by qualified and experienced technicians
to conform to all local codes and to maintain your warranty.
Caution
WARNING!
This Class B digital apparatus complies with Canadian ICES-003.
The use of CSA Certified/UL Listed Class 2 power adapters is required to
ensure compliance with electrical safety standards.
3 Inch Dome Camera
1 Preparation
2 Camera Mounting
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
WEEE (Waste Electrical and Electronic Equipment). Correct disposal of this product
(applicable in the European Union and other European countries with separate collection
systems). This product should be disposed of, at the end of its useful life, as per applicable local
laws, regulations, and procedures.
Manufacturer’s Declaration of Conformance
Product Dimensions
Contact Information
3 Camera Adjustment
4 Installation Completion
The manufacturer declares that the equipment supplied with this guide is compliant with the essential
protection requirements of the EMC directive 89/336/EEC and the Low Voltage Directive LVD 73/23
EEC, conforming to the requirements of standards EN 55022 for emissions.
Contents
0.9”
(23.0 mm)
1.8”
(46.0 mm)
4.17” (106.1 mm)
2.03”
(51.75 mm)
3.37” (85.5 mm)
1.68”
(42.8 mm)
Fully assembled camera
www.honeywellvideo.com
+1.800.796.CCTV (North America only)
[email protected]
4.9” (124.6 mm)
Mounting template
1
2
Preparation
1. Remove the dome cover
∅ 3.97”
(101 mm)
3.0” (76.2 mm)
Camera Mounting
Gently turn the dome cover counterclockwise to unlock, then pull free of
the housing.
b.
Gently pull the inner liner free of the
two notches in the housing.
c.
Set the dome and liner aside.
Camera Adjustment
a.
Electrical box (not
supplied)
Adapter plate
(optional)
a.
b.
c.
a.
Adapter plate (optional). Secure to
electrical box using appropriate screws
(not supplied).
b.
Secure camera base to ceiling or wall.
b.
Axis
ring
Base
After mounting and adjusting
the camera, attach the dome
cover:
Document 800-00789 – Rev C – 07/08
3
4S Electrical Junction Box
a.
Zoom
lever
Focus
lever
Turn the Axis ring in the desired
direction, then retighten.
Turn the Zoom lever slightly
counter-clockwise to loosen.
Then rotate around the lens for
the desired image view.
c.
Turn the Focus lever counterclockwise to loosen. Rotate to
adjust for the best picture
quality.
d.
Retighten the Zoom and Focus
levers to lock them after
making adjustments.
Do not turn the lens more than 360°.
Do not use excessive force to loosen
the levers and axis ring.
Attach the inner liner to the base until
the liner clicks into place.
Align the dome cover with the three
dome tabs on the unit.
Optional Camera Settings
Turn the dome gently clockwise until it
locks into place.
Monitor out
2. Connect the wiring
4.9” (124.6 mm)
Surface Mount
Flush Mount
Mode setting
DIP switches
Adapter plate
(optional)
24 VAC/12 VDC power connector
Video output connector
1 2 3 4 5 6 7 8
a.
Connect the video output
connector.
b.
Connect the 24 VAC/12 VDC power
connector.
Skirt
Note Please use the supplied DC Iris and Line Lock adjustment tool to adjust picture
brightness and phase adjustment.
Picture Brightness
Phase Adjustment
3. Prepare the mounting surface (surface or flush mount)
© 2008 Honeywell International Inc. All rights reserved. No part of this publication may be reproduced by any means without
written permission from Honeywell Video Systems. The information in this publication is believed to be accurate in all
respects. However, Honeywell Video Systems cannot assume responsibility for any consequences resulting from the use
thereof. The information contained herein is subject to change without notice. Revisions or new editions to this publication
may be issued to incorporate such changes.
DIP Switches
Hardware kit
Document 800-00789 – Rev C – 07/08
a.
Adapter plate (optional for ceiling tile).
Secure using appropriate screws (not
supplied).
b.
Secure camera base with ______________
screws, supplied.
Surface mount: Secure skirt to ceiling or wall
using _______ screws supplied.
a.
Mark the holes.
b.
Insert screw anchors into
holes.
Use the LEVEL screw to compensate for the iris level. L (low) darkens t
picture. H (high) brightens the picture.
This guide
Use the V Phase Adjustment Pot to adjust the phase difference betwe e
cameras. Make sure Switch 4 is ON to activate the Line lock function ( A
operation only).
Switch Function
1
2
BLC (Backlight Compensation). ON = camera automatically
adjusts the exposure. OFF = factory default.
AGC (Automatic Gain Control). ON = camera adjusts for low
light conditions. ON = factory default.
3
DC/AES Mode. Leave in ON position only.
4
LL (Line Lock). Set the camera synchronization to internal or
Line lock (only available with 24 VAC). ON= factory default.
1
2
Preparation
1. Remove the Dome Cover
Camera Adjustment
4S Electrical Junction Box
a.
b.
Security
screw
3
Camera Mounting
c.
Gently turn the dome cover counterclockwise to unlock, then pull free of
the housing. If required, loosen the
security screw first.
Gently pull the inner liner free of the
two notches in the housing.
a.
a.
Attach the inner liner to the base until
the liner clicks into place.
b.
Align the dome cover with the three
dome tabs on the unit.
c.
Turn the dome gently clockwise until it
locks into place.
Secure the adapter plate to the
electrical box using appropriate
screws (not supplied).
Adapter plate
b.
If necessary, tuck Video/Power and
BNC cabling into notch.
Screws
(not supplied)
c.
Secure camera base to ceiling or wall
with 3 screws, supplied.
Set the dome and liner aside.
After ➋ mounting and ➌
adjusting the camera, attach the
dome cover:
d.
Electrical box
(not supplied)
Legend
A = Tilt rotation
B = Horizontal rotation*
C = Pan rotation
B
C
Base
Notch
* If necessary, loosen the screw
that locks the gimbal assembly in
place, before adjusting the
camera.
A
Screws
(supplied)
Optional Camera Settings
V-Phase
Level
H
If desired, secure the dome to the base
with the security screw (see picture).
L
+
–
Focus lever
(top)
2. Prepare the Mounting Surface (Surface or Flush Mount)
Surface Mount
Monitor out
Flush Mount
Adapter plate
Mode setting
DIP switches
Use camera base or mounting
template to:
a.
b.
1 2 3 4 5 6 7 8
Mark the holes as
required.
Notch
Skirt
Base
Insert screw anchors into
holes.
= ON
= OFF
Zoom lever
(bottom)
3. Connect the Wiring
Setscrew
.
Screws
(not supplied)
24 VAC/12 VDC power connector
M3 screws
(not supplied)
The LEVEL screw compensates for the iris level. L (low) darkens the
picture. H (high) brightens the picture.
Phase Adjustment
The V Phase Adjustment Pot adjusts the phase difference between
cameras. Switch 7 must be ON to activate Line lock (AC only).
DIP Switches
Base
Video output connector
Picture Brightness
Notch
a.
Connect the video output
connector.
a.
Surface mount: Secure skirt to ceiling or wall
using appropriate screws, not supplied.
b.
Connect the 24 VAC/12 VDC power
connector.
b.
If necessary, tuck Video/Power and BNC
cabling into notch.
c.
M3 screws
(supplied)
Surface mount: Secure camera base with M3
screws, supplied.
Flush mount: Secure camera base with
appropriate M3 screws, not supplied.
(Refer to your
camera model)
Default settings are
shown in bold.
SW
High Res + TDN
High Res
Std Res
1
DC/AES
DC/AES
DC/AES
2
AWB/ATW
AWB/ATW
AWB/ATW
3
BLC ON/OFF
BLC ON/OFF
BLC ON/OFF
4
AGC ON/OFF
AGC ON/OFF
AGC ON/OFF
5
TDN
Not used
FLK
6
FLK ON/OFF
FLK ON/OFF
LL ON/OFF
7
LL ON/OFF
LL ON/OFF
Not available
8
Not used
Not used
Not available