SERIES: ETSA 18W U │ DESCRIPTION: AC-DC POWER SUPPLY
18 W power
compact size
universal input (90~264 Vac)
single regulated output from 5~15 V
over voltage and short circuit protection
UL/cUL, GS, PSE safety approvals
level V efficiency
custom designs available
output
voltage
output
current
output
power
ripple
and noise1
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
3.6
18
100
V
ETSA050360U
5
ETSA060300U
6
ETSA120150U
12
ETSA150120U
15
efficiency
level
3
18
100
V
1.5
18
100
V
1.2
18
100
V
1. At full load, 100 ~ 240 Vac input, 20 MHz bandwidth oscilloscope, each output terminated with 10 µF aluminum electrolytic and 0.1 µF ceramic capacitors.
O
PART NUMBER KEY
N
Notes:
TI
MODEL
N
U
•
•
•
•
•
•
•
•
ED
FEATURES
D
IS
C
ETSA050360U X - XX - SZ - CXX
Base Number
example of 5 Vdc, 3.6 A
DC Plug Type:
Reserved for Custom
see output plug options
Configurations
Input Cable:
on page 7
Factory
“Blank” = No Cable
Designation
C = North American input cable
2 = European input cable
3 = United Kingdom input cable
4 = Australian input cable
5 = China input cable
6 = South Korea input cable
7 = Brazil input cable
8 = South Africa input cable
9 = Japan input cable
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 18W U │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/14/2014 │ page 2 of 8
INPUT
parameter
conditions/description
min
90
frequency
47
current
inrush current
at 115 Vac, cool start
at 230 Vac, cool start
leakage current
5 V output
all other outputs
no load power consumption
line regulation
5 V output
all other outputs
load regulation
PROTECTIONS
min
N
conditions/description
U
OUTPUT
parameter
typ
conditions/description
over voltage protection
output voltage clamped by internal protection zener
short circuit protection
output shut down, auto restart
TI
parameter
SAFETY & COMPLIANCE
max
units
264
Vac
63
Hz
ED
voltage
conditions/description
min
isolation voltage
input to output at 10 mA for 1 minute
N
parameter
typ
0.5
A
40
80
A
A
3.5
0.25
mA
mA
0.3
W
max
units
±5
±1
%
%
±5
%
typ
max
units
1,500
2,121
Vac
Vdc
input to output at 500 Vdc
UL 60950-1, EN 60950-1, PSE
EMI/EMC
FCC Class B, CE, CISPR 22 Class B, EN 61204-3, EN 55022 Class B, EN 55024, EN 61000-3-(2, 3)
Class A, EN 55024, IEC 61000-4-(2, 3, 4, 5, 6, 8, 11)
RoHS
O
isolation resistance
safety approvals
100
MΩ
2011/65/EU
ENVIRONMENTAL
conditions/description
min
IS
C
parameter
max
units
0
40
°C
storage temperature
-10
70
°C
operating humidity
20
80
%
storage humidity
10
90
%
D
operating temperature
typ
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 18W U │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/14/2014 │ page 3 of 8
MECHANICAL
conditions/description
80.6 x 50 x 31 (3.173 x 1.969 x 1.220 inches)
min
input plug
IEC320 / C14
typ
max
units
mm
ED
parameter
dimensions
115
weight1
1. weight does not include AC Cord
MECHANICAL DRAWING
N
U
units: mm
tolerance: ±1mm
TI
31±1
O
N
50±1
D
IS
C
80.6±1
cui.com
g
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 18W U │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/14/2014 │ page 4 of 8
DC CORD
ED
cord length
U
S&T
CABLE GAUGE
WIRE OD
CORD LENGTH
18 AWG
Ø2.7 x 5.4
1,000 mm ±100
ETSA060300U
18 AWG
Ø2.7 x 5.4
1,000 mm ±100
ETSA120150U
20 AWG
Ø1.9 x 3.8
1,530 mm ±100
ETSA150120U
20 AWG
Ø1.9 x 3.8
1,530 mm ±100
N
MODEL NO.
ETSA050360U
NORTH AMERICAN INPUT CABLE
Ĭijıı
IJĹĴıĮĴı
IS
C
O
N
units: mm
TI
AC CORD
EUROPEAN INPUT CABLE
ń
ŏ
ō
ĵ
D
IJķ
ijĶıŗ ſ
ŚńĮIJij
ŏİIJĵĹĸĸ
ŚőĮijĴ
units: mm
Ĭijıı
ĮĴı
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 18W U │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/14/2014 │ page 5 of 8
AC CORD (CONTINUED)
UNITED KINGDOM INPUT CABLE
units: mm
ŏ
ED
ń
ŏİIJĵĹĸĸ
ŚńĮIJij
ō
ĵ
U
+200
1830 -30
AUSTRALIAN INPUT CABLE
N
TI
ŏ
ŚőĮĴĶ
ō
ņ
N
O
IS
C
D
units: mm
BLACK INSULATION
1830 ±30
cui.com
ĵ
SOUTH KOREA INPUT CABLE
ō
+200
1830-30
ŏ
units: mm
ń
CHINA INPUT CABLE
ŚńĮIJij
+200
1830-30
ŏİIJĵĹĸĸ
ŏİIJĵĹĸķġIJıłġijĶıŗſ
units: mm
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 18W U │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/14/2014 │ page 6 of 8
AC CORD (CONTINUED)
BRAZIL INPUT CABLE
ED
units: mm
U
1830±30
SOUTH AFRICA INPUT CABLE
TI
N
units: mm
1830±30
D
IS
C
units: mm
O
JAPAN INPUT CABLE
N
1830±30
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 18W U │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/14/2014 │ page 7 of 8
OUTPUT PLUG OPTIONS
14±0.5
ED
ø3.5 +0/-0.1
ø3.5 +0/-0.1
3.5 mm Phono Plug
14±0.5
*Tip positive
P1
P1R
C
Right Angle PXR
Standard PXX
B
A
O
IS
C
B
N
B
A
C
C
A
B
C
Unit
5.5
2.1
9.5
mm
P6/P6R
5.5
2.5
9.5
mm
P7/P7R
3.5
1.35
9.5
mm
P8/P8R
3.8
1.35
9.5
mm
P9/P9R
3.8
1.05
9.5
mm
TI
Locking DC Plug
EIAJ Plugs
P5/P5R
N
Standard PX
B
A
B
A
C
A
U
Standard DC Plug
A
B
C
Unit
P10
5.5
2.1
9.5
mm
P11
5.5
2.5
9.5
mm
EIAJ
A
B
C
P12/P12R
EIAJ-1
2.35
0.7
P13/P13R
EIAJ-2
4.0
1.7
P14/P14R
EIAJ-3
4.75
1.7
C
Right Angle PXXR
D
Stripped and Tinned
25±5
9±2
D
DC PLUG TYPE
PXX X X
Plug Type:
PXX = See above plug options
ST = Stripped and Tinned
Plug Angle:
“blank” = Straight
R = Right Angle
*Contact CUI for additional plug options
cui.com
Plug Polarity:
P = Center Positive
N = Center Negative
D
Unit
9.5
NA
mm
9.5
5.0
mm
9.5
5.0
mm
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 18W U │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/14/2014 │ page 8 of 8
REVISION HISTORY
rev.
description
date
12/05/2011
initial release
updated P7/P7R B dimension
1.02
V-Infinity branding removed, safety and EMI/EMC data updated
08/21/2012
1.03
updated series number
11/20/2012
1.04
ED
1.0
1.01
03/23/2012
added ac cord options
11/14/2014
D
IS
C
O
N
TI
N
U
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.