データシート

For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
date
11/18/2014
page
1 of 8
SERIES: ETSA 60W UD │ DESCRIPTION: AC-DC POWER SUPPLY
60 W power
universal input (90~264 Vac)
single regulated output from 12~48V
over voltage and short circuit protections
UL/cUL and TUV safety approvals
level V efficiency
custom designs available
output
voltage
output
current
(Vdc)
max
(A)
ETSA120500UD
12
ETSA190342UD
19
ETSA240270UD
24
ETSA480125UD
48
ripple
and noise1
max
(W)
max
(mVp-p)
5.0
60
150
V
3.42
60
190
V
2.70
60
240
V
efficiency
level
1.25
60
190
V
1. At full load, 100 ~ 240 Vac input, 20 MHz bandwidth oscilloscope, each output terminated with 10 µF aluminum electrolytic and 0.1 µF ceramic capacitors.
N
Notes:
output
power
TI
MODEL
N
U
•
•
•
•
•
•
•
ED
FEATURES
O
PART NUMBER KEY
D
IS
C
ETSA120500UD X - XX - SZ - CXX
Base Number
Factory Reserved for Custom
Configurations
Designation
example of 12 Vdc, 5 A
AC Input Plug:
D = IEC 320 C8 plug
DC Plug type:
see output plug options
on page 7
Input Cable:
“Blank” = No Cable
C = North American input cable
2 = European input cable
3 = United Kingdom input cable
4 = Australian input cable
5 = China input cable
6 = South Korea input cable
7 = Brazil input cable
8 = South Africa input cable
9 = Japan input cable
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 60W UD │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/18/2014 │ page 2 of 8
INPUT
parameter
conditions/description
min
voltage
typ
90
47
12 V model
all other models
inrush current
leakage current
no load power consumption
12 V model
all other models
OUTPUT
conditions/description
min
line regulation
PROTECTIONS
conditions/description
over voltage protection
24 V model
19, 48 V models
short circuit protection
output shut down and auto restart
parameter
min
TI
parameter
N
load regulation
SAFETY & COMPLIANCE
typ
U
parameter
conditions/description
min
units
264
Vac
63
Hz
ED
frequency
max
1.4
1.5
A
A
0.25
mA
0.5
0.3
W
W
max
units
±1
%
±5
%
typ
typ
max
units
36
32
Vdc
Vdc
max
units
3,000
4,242
Vac
Vdc
input to output at 10 mA for 1 minute
isolation resistance
input to output at 500 V dc
safety approvals
UL/cUL (UL 60950-1), CE, EN 60950-1/IEC 60950-1
EMI/EMC
FCC part 15, subpart b, class B; CE; CISPR 22, class B; ICES-003; VCCI; EN 61204-3; EN 55022; EN
55024; EN 61000-(2, 3); IEC 61000-4-(2, 3, 4, 5, 6, 8, 11)
RoHS
2011/65/EU
O
N
isolation voltage
100
MΩ
ENVIRONMENTAL
parameter
min
typ
max
units
0
40
°C
storage temperature
-10
70
°C
operating humidity
20
80
%
storage humidity
10
90
%
D
IS
C
operating temperature
conditions/description
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 60W UD │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/18/2014 │ page 3 of 8
MECHANICAL
conditions/description
4.567 x 1.969 x 1.220 (116 x 50 x 31 mm)
min
input plug
IEC320 / C8
typ
max
units
inch
ED
parameter
dimensions
MECHANICAL DRAWING
N
U
units: mm
tolerance: ±1mm
31±1
O
N
TI
50±1
D
IS
C
116±1
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 60W UD │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/18/2014 │ page 4 of 8
DC CORD
cord length
U
ED
50±10
MODEL NO.
CABLE GAUGE
CORD LENGTH
ETSA120500UD
16 AWG
1,000 ±100
18 AWG
1,830 +150/-0
18 AWG
1,530 ±100
ETSA480125UD
18 AWG
1,830 +150/-0
N
ETSA190342UD
ETSA240270UD
NORTH AMERICAN INPUT CABLE
IS
C
O
N
units: mm
TI
AC CORD
EUROPEAN INPUT CABLE
D
units: mm
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 60W UD │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/18/2014 │ page 5 of 8
AC CORD (CONTINUED)
UNITED KINGDOM INPUT CABLE
U
ED
units: mm
AUSTRALIAN INPUT CABLE
IS
C
units: mm
O
CHINA INPUT CABLE
N
TI
N
units: mm
SOUTH KOREA INPUT CABLE
D
units: mm
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 60W UD │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/18/2014 │ page 6 of 8
AC CORD (CONTINUED)
BRAZIL INPUT CABLE
U
ED
units: mm
SOUTH AFRICA INPUT CABLE
D
IS
C
units: mm
O
JAPAN INPUT CABLE
N
TI
N
units: mm
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 60W UD │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/18/2014 │ page 7 of 8
OUTPUT PLUG OPTIONS
14±0.5
ED
ø3.5 +0/-0.1
ø3.5 +0/-0.1
3.5 mm Phono Plug
14±0.5
*Tip positive
P1
P1R
C
Right Angle PXR
Standard PXX
B
A
O
IS
C
B
N
B
A
C
C
A
B
C
Unit
5.5
2.1
9.5
mm
P6/P6R
5.5
2.5
9.5
mm
P7/P7R
3.5
1.35
9.5
mm
P8/P8R
3.8
1.35
9.5
mm
P9/P9R
3.8
1.05
9.5
mm
TI
Locking DC Plug
EIAJ Plugs
P5/P5R
N
Standard PX
B
A
B
A
C
A
U
Standard DC Plug
A
B
C
Unit
P10
5.5
2.1
9.5
mm
P11
5.5
2.5
9.5
mm
EIAJ
A
B
C
P12/P12R
EIAJ-1
2.35
0.7
P13/P13R
EIAJ-2
4.0
1.7
P14/P14R
EIAJ-3
4.75
1.7
C
Right Angle PXXR
D
Stripped and Tinned
25±5
9±2
D
DC PLUG TYPE
PXX X X
Plug Type:
PXX = See above plug options
ST = Stripped and Tinned
Plug Angle:
“blank” = Straight
R = Right Angle
*Contact CUI for additional plug options
cui.com
Plug Polarity:
P = Center Positive
N = Center Negative
D
Unit
9.5
NA
mm
9.5
5.0
mm
9.5
5.0
mm
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 60W UD │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/18/2014 │ page 8 of 8
REVISION HISTORY
rev.
description
date
01/24/2010
initial release
new template applied
1.02
P7/P7R B dimension updated, V-Infinity branding removed, safety and
EMI/EMC data updated
08/21/2012
1.03
updated series/model numbers
11/20/2012
1.04
corrected dc cord lengths
1.05
added ac cord options
ED
1.0
1.01
12/22/2011
01/16/2013
11/18/2014
D
IS
C
O
N
TI
N
U
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.