For more information, please visit the product page | For information on related products, view Dc Power Jacks date 01/21/2015 page 1 of 8 SERIES: ETSA 40W UD │ DESCRIPTION: AC-DC POWER SUPPLY 40 W power compact size universal input (90~264 Vac) single regulated output from 12~48 V over voltage and short circuit protection UL/cUL, GS safety approvals level V efficiency custom designs available MODEL (Vdc) 12 ETSA190210UD 19 ETSA200200UD 20 ETSA240170UD 24 ETSA480085UD 48 Notes: output power ripple and noise1 max (A) max (W) max (mVp-p) 3.3 40 240 V 2.1 40 240 V 2 40 240 V 1.7 40 240 V 0.85 40 240 V N ETSA120330UD output current TI output voltage N U • • • • • • • • ED FEATURES efficiency level 1. At full load, 100 ~ 240 Vac input, 20 MHz bandwidth oscilloscope, each output terminated with 10 µF aluminum electrolytic and 0.1 µF ceramic capacitors. O PART NUMBER KEY D IS C ETSA120330UD X - XX - SZ - CXX Reserved for Custom Configurations Base Number example of 12 Vdc, 3.3 A Factory Designation AC Input Plug: D = IEC 320 C8 plug DC Plug Type: Input Cable: see output plug options “Blank” = No Cable on page 7 C = North American input cable 2 = European input cable 3 = United Kingdom input cable 4 = Australian input cable 5 = China input cable 6 = South Korea input cable 7 = Brazil input cable 8 = South Africa input cable 9 = Japan input cable cui.com For more information, please visit the product page | For information on related products, view Dc Power Jacks CUI Inc │ SERIES: ETSA 40W UD │ DESCRIPTION: AC-DC POWER SUPPLY date 01/21/2015 │ page 2 of 8 INPUT max units voltage conditions/description min 85 264 Vac frequency 47 63 current leakage current at 120 Vac no load power consumption OUTPUT parameter typ conditions/description min typ 1 RMS 0.25 mA 0.3 W max units ±1 U line regulation load regulation % ±5 parameter conditions/description short circuit protection output shut down and auto restart conditions/description typ min typ TI parameter min N PROTECTION SAFETY & COMPLIANCE % max units max units 3,000 4,242 Vac Vac isolation voltage input to output at 10 mA for 1 minute isolation resistance input to output at 500 Vdc safety approvals UL 60950-1, EN 60950-1/IEC 60950-1, CSA C22.2 No. 60950-1 EMI/EMC FCC CFR 47 Part 15, EN 55022, EN 61000-3, EN 55024 (EN 61204-3), EN 61000-4, CE RoHS 2011/65/EU operating temperature storage temperature operating humidity D IS C storage humidity conditions/description O parameter 100 N ENVIRONMENTAL Hz ED parameter cui.com min MΩ typ max units 0 40 °C -10 70 °C 20 80 % 10 90 % For more information, please visit the product page | For information on related products, view Dc Power Jacks CUI Inc │ SERIES: ETSA 40W UD │ DESCRIPTION: AC-DC POWER SUPPLY date 01/21/2015 │ page 3 of 8 MECHANICAL conditions/description 2.972 x 1.882 x 1.110 (75.5 x 47.8 x 28.2 mm) min input plug IEC320 / C8 typ max units inch ED parameter dimensions MECHANICAL DRAWING D IS C O N TI N U units: mm tolerance: ±1mm cui.com For more information, please visit the product page | For information on related products, view Dc Power Jacks CUI Inc │ SERIES: ETSA 40W UD │ DESCRIPTION: AC-DC POWER SUPPLY date 01/21/2015 │ page 4 of 8 DC CORD ED cord length U S&T CABLE GAUGE CABLE LENGTH 18 AWG 1,530 ±100 ETSA190210UD 20 AWG 1,830 +150/-0 ETSA200200UD 20 AWG 1,830 +150/-0 ETSA240170UD 20 AWG 1,830 +150/-0 ETSA480085UD 22 AWG 1,830 ±100 AC CORD NORTH AMERICAN INPUT CABLE IS C O N units: mm TI N MODEL ETSA120330UD EUROPEAN INPUT CABLE D units: mm cui.com For more information, please visit the product page | For information on related products, view Dc Power Jacks CUI Inc │ SERIES: ETSA 40W UD │ DESCRIPTION: AC-DC POWER SUPPLY date 01/21/2015 │ page 5 of 8 AC CORD (CONTINUED) UNITED KINGDOM INPUT CABLE U ED units: mm AUSTRALIAN INPUT CABLE IS C units: mm O CHINA INPUT CABLE N TI N units: mm SOUTH KOREA INPUT CABLE D units: mm cui.com For more information, please visit the product page | For information on related products, view Dc Power Jacks CUI Inc │ SERIES: ETSA 40W UD │ DESCRIPTION: AC-DC POWER SUPPLY date 01/21/2015 │ page 6 of 8 AC CORD (CONTINUED) BRAZIL INPUT CABLE U ED units: mm SOUTH AFRICA INPUT CABLE D IS C units: mm O JAPAN INPUT CABLE N TI N units: mm cui.com For more information, please visit the product page | For information on related products, view Dc Power Jacks CUI Inc │ SERIES: ETSA 40W UD │ DESCRIPTION: AC-DC POWER SUPPLY date 01/21/2015 │ page 7 of 8 OUTPUT PLUG OPTIONS 14±0.5 ED ø3.5 +0/-0.1 ø3.5 +0/-0.1 3.5 mm Phono Plug 14±0.5 *Tip positive P1 P1R C Right Angle PXR Standard PXX B A O IS C B N B A C C A B C Unit 5.5 2.1 9.5 mm P6/P6R 5.5 2.5 9.5 mm P7/P7R 3.5 1.35 9.5 mm P8/P8R 3.8 1.35 9.5 mm P9/P9R 3.8 1.05 9.5 mm TI Locking DC Plug EIAJ Plugs P5/P5R N Standard PX B A B A C A U Standard DC Plug A B C Unit P10 5.5 2.1 9.5 mm P11 5.5 2.5 9.5 mm EIAJ A B C P12/P12R EIAJ-1 2.35 0.7 P13/P13R EIAJ-2 4.0 1.7 P14/P14R EIAJ-3 4.75 1.7 C Right Angle PXXR D Stripped and Tinned 25±5 9±2 D DC PLUG TYPE PXX X X Plug Type: PXX = See above plug options ST = Stripped and Tinned Plug Angle: “blank” = Straight R = Right Angle *Contact CUI for additional plug options cui.com Plug Polarity: P = Center Positive N = Center Negative D Unit 9.5 NA mm 9.5 5.0 mm 9.5 5.0 mm For more information, please visit the product page | For information on related products, view Dc Power Jacks CUI Inc │ SERIES: ETSA 40W UD │ DESCRIPTION: AC-DC POWER SUPPLY date 01/21/2015 │ page 8 of 8 REVISION HISTORY description 1.0 initial release 1.01 applied new spec template 1.02 updated voltage 1.03 updated P7/P7R B dimension date 05/18/2010 ED rev. 08/02/2011 12/22/2011 03/23/2012 updated safety and EMI/EMC data 1.05 safety and EMI/EMC data updated, V-Infinity branding removed 08/15/2012 1.06 updated series/model numbers 11/20/2012 1.07 corrected dc cord lengths 1.08 removed PSE 1.09 added ac cord options updated datasheet 01/16/2013 06/11/2013 11/18/2014 N 1.10 05/15/2012 U 1.04 01/21/2015 D IS C O N TI The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com [email protected] This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.