データシート

For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
date
01/21/2015
page
1 of 8
SERIES: ETSA 40W UD │ DESCRIPTION: AC-DC POWER SUPPLY
40 W power
compact size
universal input (90~264 Vac)
single regulated output from 12~48 V
over voltage and short circuit protection
UL/cUL, GS safety approvals
level V efficiency
custom designs available
MODEL
(Vdc)
12
ETSA190210UD
19
ETSA200200UD
20
ETSA240170UD
24
ETSA480085UD
48
Notes:
output
power
ripple
and noise1
max
(A)
max
(W)
max
(mVp-p)
3.3
40
240
V
2.1
40
240
V
2
40
240
V
1.7
40
240
V
0.85
40
240
V
N
ETSA120330UD
output current
TI
output
voltage
N
U
•
•
•
•
•
•
•
•
ED
FEATURES
efficiency
level
1. At full load, 100 ~ 240 Vac input, 20 MHz bandwidth oscilloscope, each output terminated with 10 µF aluminum electrolytic and 0.1 µF ceramic capacitors.
O
PART NUMBER KEY
D
IS
C
ETSA120330UD X - XX - SZ - CXX
Reserved for Custom
Configurations
Base Number
example of 12 Vdc, 3.3 A
Factory
Designation
AC Input Plug:
D = IEC 320 C8 plug
DC Plug Type:
Input Cable:
see output plug options
“Blank” = No Cable
on page 7
C = North American input cable
2 = European input cable
3 = United Kingdom input cable
4 = Australian input cable
5 = China input cable
6 = South Korea input cable
7 = Brazil input cable
8 = South Africa input cable
9 = Japan input cable
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 40W UD │ DESCRIPTION: AC-DC POWER SUPPLY
date 01/21/2015 │ page 2 of 8
INPUT
max
units
voltage
conditions/description
min
85
264
Vac
frequency
47
63
current
leakage current
at 120 Vac
no load power consumption
OUTPUT
parameter
typ
conditions/description
min
typ
1
RMS
0.25
mA
0.3
W
max
units
±1
U
line regulation
load regulation
%
±5
parameter
conditions/description
short circuit protection
output shut down and auto restart
conditions/description
typ
min
typ
TI
parameter
min
N
PROTECTION
SAFETY & COMPLIANCE
%
max
units
max
units
3,000
4,242
Vac
Vac
isolation voltage
input to output at 10 mA for 1 minute
isolation resistance
input to output at 500 Vdc
safety approvals
UL 60950-1, EN 60950-1/IEC 60950-1, CSA C22.2 No. 60950-1
EMI/EMC
FCC CFR 47 Part 15, EN 55022, EN 61000-3, EN 55024 (EN 61204-3), EN 61000-4, CE
RoHS
2011/65/EU
operating temperature
storage temperature
operating humidity
D
IS
C
storage humidity
conditions/description
O
parameter
100
N
ENVIRONMENTAL
Hz
ED
parameter
cui.com
min
MΩ
typ
max
units
0
40
°C
-10
70
°C
20
80
%
10
90
%
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 40W UD │ DESCRIPTION: AC-DC POWER SUPPLY
date 01/21/2015 │ page 3 of 8
MECHANICAL
conditions/description
2.972 x 1.882 x 1.110 (75.5 x 47.8 x 28.2 mm)
min
input plug
IEC320 / C8
typ
max
units
inch
ED
parameter
dimensions
MECHANICAL DRAWING
D
IS
C
O
N
TI
N
U
units: mm
tolerance: ±1mm
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 40W UD │ DESCRIPTION: AC-DC POWER SUPPLY
date 01/21/2015 │ page 4 of 8
DC CORD
ED
cord length
U
S&T
CABLE GAUGE
CABLE LENGTH
18 AWG
1,530 ±100
ETSA190210UD
20 AWG
1,830 +150/-0
ETSA200200UD
20 AWG
1,830 +150/-0
ETSA240170UD
20 AWG
1,830 +150/-0
ETSA480085UD
22 AWG
1,830 ±100
AC CORD
NORTH AMERICAN INPUT CABLE
IS
C
O
N
units: mm
TI
N
MODEL
ETSA120330UD
EUROPEAN INPUT CABLE
D
units: mm
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 40W UD │ DESCRIPTION: AC-DC POWER SUPPLY
date 01/21/2015 │ page 5 of 8
AC CORD (CONTINUED)
UNITED KINGDOM INPUT CABLE
U
ED
units: mm
AUSTRALIAN INPUT CABLE
IS
C
units: mm
O
CHINA INPUT CABLE
N
TI
N
units: mm
SOUTH KOREA INPUT CABLE
D
units: mm
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 40W UD │ DESCRIPTION: AC-DC POWER SUPPLY
date 01/21/2015 │ page 6 of 8
AC CORD (CONTINUED)
BRAZIL INPUT CABLE
U
ED
units: mm
SOUTH AFRICA INPUT CABLE
D
IS
C
units: mm
O
JAPAN INPUT CABLE
N
TI
N
units: mm
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 40W UD │ DESCRIPTION: AC-DC POWER SUPPLY
date 01/21/2015 │ page 7 of 8
OUTPUT PLUG OPTIONS
14±0.5
ED
ø3.5 +0/-0.1
ø3.5 +0/-0.1
3.5 mm Phono Plug
14±0.5
*Tip positive
P1
P1R
C
Right Angle PXR
Standard PXX
B
A
O
IS
C
B
N
B
A
C
C
A
B
C
Unit
5.5
2.1
9.5
mm
P6/P6R
5.5
2.5
9.5
mm
P7/P7R
3.5
1.35
9.5
mm
P8/P8R
3.8
1.35
9.5
mm
P9/P9R
3.8
1.05
9.5
mm
TI
Locking DC Plug
EIAJ Plugs
P5/P5R
N
Standard PX
B
A
B
A
C
A
U
Standard DC Plug
A
B
C
Unit
P10
5.5
2.1
9.5
mm
P11
5.5
2.5
9.5
mm
EIAJ
A
B
C
P12/P12R
EIAJ-1
2.35
0.7
P13/P13R
EIAJ-2
4.0
1.7
P14/P14R
EIAJ-3
4.75
1.7
C
Right Angle PXXR
D
Stripped and Tinned
25±5
9±2
D
DC PLUG TYPE
PXX X X
Plug Type:
PXX = See above plug options
ST = Stripped and Tinned
Plug Angle:
“blank” = Straight
R = Right Angle
*Contact CUI for additional plug options
cui.com
Plug Polarity:
P = Center Positive
N = Center Negative
D
Unit
9.5
NA
mm
9.5
5.0
mm
9.5
5.0
mm
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 40W UD │ DESCRIPTION: AC-DC POWER SUPPLY
date 01/21/2015 │ page 8 of 8
REVISION HISTORY
description
1.0
initial release
1.01
applied new spec template
1.02
updated voltage
1.03
updated P7/P7R B dimension
date
05/18/2010
ED
rev.
08/02/2011
12/22/2011
03/23/2012
updated safety and EMI/EMC data
1.05
safety and EMI/EMC data updated, V-Infinity branding removed
08/15/2012
1.06
updated series/model numbers
11/20/2012
1.07
corrected dc cord lengths
1.08
removed PSE
1.09
added ac cord options
updated datasheet
01/16/2013
06/11/2013
11/18/2014
N
1.10
05/15/2012
U
1.04
01/21/2015
D
IS
C
O
N
TI
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.