データシート

For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
date
11/18/2014
page
1 of 8
SERIES: ETSA 90W UD │ DESCRIPTION: AC-DC POWER SUPPLY
90 W power
universal input (90~264 Vac)
single regulated outputs
over voltage and short circuit protections
UL/cUL safety approvals
level V efficiency
power factor correction
custom designs available
output
voltage
output
current
output
power
ripple
and noise1
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
7.5
90
300
V
4.74
90
300
V
3.75
90
300
V
1.875
90
300
V
ETSA120750UD
12
ETSA190474UD
19
ETSA240375UD
24
ETSA4801875UD
48
efficiency
level
1. Ripple and noise measured with 20 MHz bandwidth oscilloscope, each output terminated with 10 µF aluminum electrolytic and 0.1 µF ceramic capacitors.
N
Notes:
TI
MODEL
N
U
•
•
•
•
•
•
•
•
ED
FEATURES
O
PART NUMBER KEY
D
IS
C
ETSA120750UDX - XX - SZ - CXX
Base Number
example of 12 Vdc, 7.50 A
DC Plug Type:
see output plug
options on page 7
Input Cable:
“Blank” = No Cable
C = North American input cable
2 = European input cable
3 = United Kingdom input cable
4 = Australian input cable
5 = China input cable
6 = South Korea input cable
7 = Brazil input cable
8 = South Africa input cable
9 = Japan input cable
cui.com
Factory
Designation
Reserved for Custom
Configurations
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 90W UD │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/18/2014 │ page 2 of 8
INPUT
parameter
conditions/description
min
voltage
47
current
RMS
inrush current
at 115 Vac, cold start
at 230 Vac, cold start
power factor correction
0.9
leakage current
no load power consumption
parameter
U
OUTPUT
conditions/description
min
load regulation
max
units
264
Vac
63
Hz
ED
frequency
typ
1.5
A
80
120
A
A
0.25
mA
0.5
W
max
units
±5
N
PROTECTIONS
conditions/description
over voltage protection
output shutdown
12Vdc output models
19Vdc output models
24Vdc output models
48Vdc output models
min
short circuit protection
output shutdown and auto restart
TI
parameter
SAFETY & COMPLIANCE
conditions/description
input to output for 1 minute at 10mA max
min
N
parameter
isolation voltage
typ
max
units
18
30
35
60
Vdc
Vdc
Vdc
Vdc
max
units
Vac
100
MΩ
isolation resistance
input to output at 500 Vdc
UL 60950-1, EN 60950-1, IEC 60950-1; UL/cUL, GS, PSE
EMI/EMC
FCC Part 15 Subpart B, Class B, EN55022 Class B, CE
O
typ
%
3,000
safety approvals
RoHS
typ
90
2011/65/EU
ENVIRONMENTAL
parameter
min
IS
C
operating temperature
conditions/description
max
units
0
40
°C
-20
70
°C
operating humidity
non-condensing
20
80
%
storage humidity
non-condensing
10
90
%
D
storage temperature
typ
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 90W UD │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/18/2014 │ page 3 of 8
MECHANICAL
conditions/description
149.4 x 62.4 x 33.5
input plug
IEC320 / C8
min
typ
max
units
mm
ED
parameter
dimensions
MECHANICAL DRAWING
N
U
units: mm
tolerance: ±1 mm
ķijįĵƲIJ
O
N
TI
ĴĴįĶƲIJ
D
IS
C
IJĵĺįĵƲIJ
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 90W UD │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/18/2014 │ page 4 of 8
DC CORD
units: mm
ńŰųťġōŦůŨŵũ
ŇŦųųŪŵŦġŤŰųŦ
IJijı
MODEL NO.
ED
ĶıƲIJı
ĵĺŃ
CABLE GAUGE
WIRE OD
16 AWG
Ø3.7 x 7.4
1,000 ±100
16 AWG
Ø3.7 x 7.4
1,530 ±100
U
ETSA120750UD
ETSA190474UD
16 AWG
Ø3.7 x 7.4
1,530 ±100
18 AWG
Ø2.7 x 5.4
1,530 ±100
N
ETSA240375UD
ETSA4801875UD
NORTH AMERICAN INPUT CABLE
IS
C
O
N
units: mm
TI
AC CORD
CORD LENGTH
EUROPEAN INPUT CABLE
D
units: mm
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 90W UD │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/18/2014 │ page 5 of 8
AC CORD (CONTINUED)
UNITED KINGDOM INPUT CABLE
U
ED
units: mm
AUSTRALIAN INPUT CABLE
IS
C
units: mm
O
CHINA INPUT CABLE
N
TI
N
units: mm
SOUTH KOREA INPUT CABLE
D
units: mm
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 90W UD │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/18/2014 │ page 6 of 8
AC CORD (CONTINUED)
BRAZIL INPUT CABLE
U
ED
units: mm
SOUTH AFRICA INPUT CABLE
D
IS
C
units: mm
O
JAPAN INPUT CABLE
N
TI
N
units: mm
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 90W UD │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/18/2014 │ page 7 of 8
OUTPUT PLUG OPTIONS
Standard PX
Ń
ł
Ń
ł
A
ń
ń
ED
Standard DC Plug
B
P5/P5R
5.5
2.1
9.5
mm
5.5
2.5
9.5
mm
U
Locking DC Plug
A
B
C
Unit
P10
5.5
2.1
9.5
mm
P11
5.5
2.5
9.5
mm
TI
N
ł
Ń
Stripped and Tinned
IS
C
O
N
ijĶƲĶ
DC PLUG TYPE
Plug Type:
PXX = See above plug options
ST = Stripped and Tinned
PXX X X
Plug Angle:
“blank” = Straight
R = Right Angle
D
*Contact CUI for additional plug options
cui.com
Unit
P6/P6R
Right Angle PXR
ń
C
Plug Polarity:
P = Center Positive
N = Center Negative
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: ETSA 90W UD │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/18/2014 │ page 8 of 8
REVISION HISTORY
description
date
1.0
initial release
05/29/2014
1.01
added ac cord options
ED
rev.
11/18/2014
D
IS
C
O
N
TI
N
U
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.