1630 SS IR Curtain Wall - Architectural Detail Manual

1630 SS IR
JULY, 2014
EC 97911-063
FEATURES
Features
• 1630 SS IR is an outside glazed captured curtain wall system
• 1630 SS IR has a 3" (76.2 mm) sight line
• Standard 7-13/16" (198.4 mm) or 8-13/16" (223.8 mm) depth systems
• Infill 1-5/16" (33.3 mm)
• Thermally Broken by means of a continuous 1/4" (6.4 mm) low conductance spacer
• Perimeter seal can be installed at the pressure plate or mullion shoulder
• Frame options available to accommodate design pressures from 70 psf to 130 psf
• 1630 SS IR can be supplied fabricated and KD or in stock lengths
• Dry Glazing and Wet Glazing option
• Interlocking mullion design eliminates need for anti-buckling clips
• Concealed fastener joinery creates smooth, monolithic appearance
• EPDM gaskets and thermal break
• Screw spline joinery method allows shop assembly of ladder sections, reducing field labor
• Corners available with shear block fabrication method
• Offers entrance framing systems
• Silicone compatible glazing materials for long-lasting seals
• Two color option
• PermanodicTM anodized finishes in seven choices
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
• Painted finishes in standard and custom choices
Additional Features*
• Large Missile and Small Missile Hurricane Impact tested
• Blast Mitigation tested
Product Applications
• Ideal for low-rise applications where high performance is desired
• Most of the product assembly can be done in the shop rather than the field.
This allows for better quality control and reduces expensive field labor.
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
1
*See NOA product approval for specific features tested and approved for hurricane impact.
For specific product applications,
Consult your Kawneer representative.
kawneer.com
ADMD180
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1630 SS IR
BLANK PAGE
ADMD180
kawneer.com
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
2
JULY, 2014
EC 97911-063
1630 SS IR
JULY, 2014
EC 97911-063
3
INDEX
PICTORIAL VIEW................................................................................ 5
TYPICAL FRAMING DETAILS.........................................................6, 7
HURRICANE IMPACT RESISTANT ENTRANCE
FRAMING DETAILS....................................................................8, 9
CORNER DETAILS....................................................................... 10-12
WINDOW INTEGRATION.................................................................. 13
ANCHORING................................................................................14, 15
WIND LOAD / DEADLOAD CHARTS........................................... 16-19
THERMAL CHARTS .................................................................... 20-24
LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED
ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT
CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR
GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR.
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Architects - Most extrusion and window types illustrated in this catalog are standard products for Kawneer. These concepts have been expanded
and modified to afford you design freedom. Some miscellaneous details are non-standard and are intended to demonstrate how the system can be
modified to expand design flexibility. Please contact your Kawneer representative for further assistance.
Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses
(
) are millimeters unless otherwise noted.
The following metric (SI ) units are found in these details:
m –meter
cm – centimeter
mm –millimeter
s –second
Pa –pascal
MPa –megapascal
Kawneer reserves the right to change configurations without prior notice when deemed necessary for product
improvement.
kawneer.com
ADMD180
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1630 SS IR
BLANK PAGE
ADMD180
kawneer.com
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
4
JULY, 2014
EC 97911-063
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
JULY, 2014
1630 SS IR
EC 97911-063
PICTORIAL VIEW
kawneer.com
ADMD180
5
OPTIONAL WET GLAZING
6
8
7
9
ENTRANCE
DETAILS
4
7-13/16"
(198.4)
LARGE MISSILE (LMI)
8-13/16"
(223.8)
1
HEAD
1
1A
3
2
HORIZONTAL
CORNER
DETAILS
5
5A
ELEVATION IS NUMBER KEYED TO DETAILS
TYPICAL ELEVATION
5
SILL
ADMD180
kawneer.com
© Kawneer Company, Inc., 2014
TYPICAL FRAMING DETAILS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1/2"
(12.7)
1630 SS IR
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
3"
(76.2)
6
JULY, 2014
EC 97911-063
SCALE 3" = 1'-0"
2
ANCHOR
DETAILS
© Kawneer Company, Inc., 2014
7-13/16"
(198.4)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1/2"
(12.7)
1/2"
(12.7)
6
LEFT JAMB
8-13/16" DEEP
kawneer.com
8-13/16"
(223.8)
7-13/16"
(198.4)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
JULY, 2014
1630 SS IR
EC 97911-063
TYPICAL FRAMING DETAILS
SCALE 3" = 1'-0"
3"
(76.2)
6
LEFT JAMB
7-13/16" DEEP
3"
(76.2)
8
VERTICAL
7-13/16" DEEP
6
RIGHT JAMB
7-13/16" DEEP
8
VERTICAL
8-13/16" DEEP
6
RIGHT JAMB
8-13/16" DEEP
ADMD180
7
1630 SS IR
8
JULY, 2014
HURRICANE IMPACT RESISTANT ENTRANCE FRAMING DETAILS
EC 97911-063
SCALE 3" = 1'-0"
7-13/16"
(198.4)
1
2
3
1/8"
(3.1)
1/8"
(3.1)
2"
(50.8)
2
3
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
3"
(76.2)
1
ENTRANCE ELEVATION
5"
(127)
ELEVATION IS NUMBER KEYED TO DETAILS
NOTE: DOORS SHOWN GLAZED
WITH 9/16" INFILL
OPTIONAL
1" DOOR INFILL
LARGE MISSILE (LMI)
1"
(25.4)
3"
(76.2)
1"
(25.4)
3"
(76.2)
3
DOOR JAMB
2
DOOR JAMB
CONTINUOUS HINGE
LARGE MISSILE (LMI)
BUTT HUNG
OR
OFFSET PIVOT
LARGE MISSILE (LMI)
ADMD180
kawneer.com
© Kawneer Company, Inc., 2014
BUTT HUNG OR OFFSET PIVOT
WITH SINGLE ACTING OFFSET ARM
CONCEALED OVERHEAD CLOSER
LARGE MISSILE (LMI)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
1
TRANSOM BAR
1630 SS IR
JULY, 2014
EC 97911-063
HURRICANE IMPACT RESISTANT ENTRANCE FRAMING DETAILS
SCALE 3" = 1'-0"
8-13/16"
(223.8)
7-13/16"
(198.4)
3"
(76.2)
1/8"
(3.1)
2"
(50.8)
2
3
ENTRANCE ELEVATION
5"
(127)
ELEVATION IS NUMBER KEYED TO DETAILS
NOTE: DOORS SHOWN GLAZED
WITH 9/16" INFILL
1
TRANSOM BAR
BUTT HUNG OR OFFSET PIVOT
WITH SINGLE ACTING OFFSET ARM
CONCEALED OVERHEAD CLOSER
LARGE MISSILE (LMI)
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
1
2
3
1/8"
(3.1)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1
3"
(76.2)
OPTIONAL
1" DOOR INFILL
LARGE MISSILE (LMI)
1"
(25.4)
3"
(76.2)
3
DOOR JAMB
2
DOOR JAMB
CONTINUOUS HINGE
LARGE MISSILE (LMI)
BUTT HUNG
OR
OFFSET PIVOT
LARGE MISSILE (LMI)
kawneer.com
1"
(25.4)
ADMD180
9
90° OUTSIDE CORNER
7-13/16" DEEP
90° OUTSIDE CORNER
8-13/16" DEEP
90° INSIDE CORNER
7-13/16" DEEP
90° INSIDE CORNER
8-13/16" DEEP
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1630 SS IR
JULY, 2014
CORNER DETAILS
EC 97911-063
ADMD180
kawneer.com
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
10
SCALE 3" = 1'-0"
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
JULY, 2014
1630 SS IR
EC 97911-063
CORNER DETAILS
SCALE 3" = 1'-0"
135° OUTSIDE CORNER
7-13/16" DEEP
kawneer.com
135° OUTSIDE CORNER
8-13/16" DEEP
135° INSIDE CORNER
7-13/16" DEEP
ADMD180
11
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1630 SS IR
JULY, 2014
CORNER DETAILS
EC 97911-063
135° OUTSIDE CORNER
7-13/16" DEEP
135° OUTSIDE CORNER
8-13/16" DEEP
ADMD180
kawneer.com
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
12
SCALE 3" = 1'-0"
135° INSIDE CORNER
8-13/16" DEEP
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
JULY, 2014
kawneer.com
1630 SS IR
EC 97911-063
WINDOW INTEGRATION
SCALE 3" = 1'-0"
Shown with AATM 900 IsoWebTM Window
NOTE: Other vent types can be accommodated. Contact your
Kawneer representative for other options.
HEAD
JAMB
SILL
ADMD180
13
1" (25.4) MINIMUM
ANCHORING TO FLOOR SLAB
1" (25.4) MINIMUM
ANCHORING TO SUPPORT STEEL
ADMD180
kawneer.com
© Kawneer Company, Inc., 2014
ANCHORING
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1630 SS IR
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
14
JULY, 2014
EC 97911-063
Actual project conditions will determine specific anchor design. Details on this page are for reference only.
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
JULY, 2014
kawneer.com
1630 SS IR
EC 97911-063
ANCHORING
Actual project conditions will determine specific anchor design. Details on this page are for reference only.
1" (25.4) MINIMUM
ANCHORING TO HORIZONTAL
STRUCTURAL STEEL
1" (25.4) MINIMUM
ANCHORING TO VERTICAL
STRUCTURAL STEEL
ADMD180
15
16
1630 SS IR
JULY, 2014
WIND LOAD / DEADLOAD CHARTS
EC 97911-063
DEAD LOAD CHARTS
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Horizontal or deadload limitations are based upon 1/8" (3.2), maximum allowable deflection at the center of an intermediate
horizontal member. The accompanying charts are calculated for 1" (25) thick insulating glass or 1/4" (6) thick glass supported
on two setting blocks placed at the loading points shown.
ADMD180
kawneer.com
© Kawneer Company, Inc., 2014
Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4"
above 13'-6". These curves are for mullions WITH HORIZONTALS and are based on engineering calculations for stress
and deflection. Allowable wind load stress for ALUMINUM 15,152 psi (104MPa), STEEL 30,000 psi (207MPa.). Charted
curves, in all cases are for the limiting value. If the design wind load is determined through the analytical procedures
of ASCE/SEI 7-10 or earlier editions, the load shall be based on the nominal loads used in allowable stress design. A
4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these
curves, contact your Kawneer representative for additional information.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
WIND LOAD CHARTS
1630 SS IR
JULY, 2014
WIND LOAD CHARTS (1-5/16" INFILL)
A = 60 PSF (2880)
B = 75 PSF (3600)
C = 90 PSF (4320)
D = 110 PSF (5280)
E = 130 PSF (6240)
MULLION CENTERS IN METERS
2.0
17
29
11
10
3.0
7
A
B
C
D
6
E
9
8
2.0
5
4
EQUAL
25
7.0
23
22
21
20
6.0
A
19
18
B
17
5.0
C
15
D
E4.0
14
13
0
1
2
3
4
5
6
7
176001
8
176002
12
I = 15.354 (639.08 x 104)
S = 4.413 (72.32 x 103)
0
1
2
3
4
5
6
7
8
MULLION CENTERS IN FEET
SINGLE SPAN
TWIN SPAN
MULLION CENTERS IN METERS
MULLION CENTERS IN METERS
1.0
2.0
18
30
17
29
10
C
D
E
9
8
7
2.0
6
5
4
1.0
3
EQUAL
27
24
21
4
5
6
7
8
MULLION CENTERS IN FEET
kawneer.com
176003
176004
I = 24.511 (1020.22 x 104)
S = 5.766 (94.49 x 103)
ADMD180
B6.0
20
19
C
18
17
5.0
16
D
15
E
13
3
A
22
1
2
7.0
23
14
1
8.0
26
2
0
9.0
28
MULLION HEIGHT IN FEET
A
B3.0
11
2.0
25
EQUAL
12
MULLION HEIGHT IN METERS
4.0
13
MULLION HEIGHT
15
14
MULLION HEIGHT
5.0
16
MULLION HEIGHT IN FEET
24
16
1
0
8.0
26
2
0
9.0
27
1.0
3
2.0
28
MULLION HEIGHT IN FEET
12
MULLION HEIGHT IN METERS
4.0
13
EQUAL
14
MULLION HEIGHT
15
MULLION HEIGHT
5.0
1.0
© Kawneer Company, Inc., 2014
1.0
30
MULLION CENTERS IN FEET
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
MULLION CENTERS IN METERS
18
16
MULLION HEIGHT IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1.0
TWIN SPAN
MULLION HEIGHT IN METERS
SINGLE SPAN
12
4.0
0
1
2
3
4
5
6
7
8
MULLION CENTERS IN FEET
MULLION HEIGHT IN METERS
EC 97911-063
17
1630 SS IR
JULY, 2014
WIND LOAD CHARTS (1-5/16" INFILL)
A = 60 PSF (2880)
B = 75 PSF (3600)
C = 90 PSF (4320)
D = 110 PSF (5280)
E = 130 PSF (6240)
2.0
26
1.0
19
18
17
5.0
16
15
A
14
B
4.0
13
C
12
D
E
11
10
9.0
A
29
28
27
26
B
24
C
23
7.0
22
D
20
6.0
E
19
3.0
8.0
25
21
9
18
0
1
2
3
4
5
6
7
8
176003
176004
With 176229 (1/2" x 5") Steel Bars
17
0
1
2
3
4
5
6
7
8
MULLION CENTERS IN FEET
MULLION CENTERS IN FEET
I = 24.511 (1020.22 x 104)
S = 6.180 (101.27 x 103)
Steel
I = 5.208 (216.77x 104)
S = 2.083 (34.13 x 103)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
8
31
MULLION HEIGHT IN FEET
6.0
10.0
32
30
EQUAL
20
MULLION HEIGHT IN METERS
21
MULLION HEIGHT
22
EQUAL
33
MULLION HEIGHT
34
24
7.0
2.0
35
25
23
MULLION HEIGHT IN FEET
MULLION CENTERS IN METERS
ADMD180
kawneer.com
© Kawneer Company, Inc., 2014
MULLION CENTERS IN METERS
TWIN SPAN
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
SINGLE SPAN
1.0
EC 97911-063
MULLION HEIGHT IN METERS
18
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
GLASS HEIGHT IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1.0
13
11
12
10
kawneer.com
9
0
3.0
8
7
A
6
2.0
5
4
3
1.0
1
2
3
4
5
6
7
GLASS HEIGHT IN METERS
JULY, 2014
1630 SS IR
EC 97911-063
DEADLOAD CHARTS
(1-5/16" INFILL)
SPAN IN METERS
16
2.0
15
A = 1/4 POINT LOADING
B = 1/8 POINT LOADING
14
B
4.0
I = 3.334 (138.77 x 104)
S = 2.222 (36.41 x 103)
176007
2
1
SPAN IN FEET
8
ADMD180
19
1630 SS IR
20
JULY, 2014
THERMAL CHARTS
EC 97911-063
Generic Project Specific U-factor Example Calculation
(Percent of Glass will vary on specific products depending on sitelines)
(Based on single bay of Curtain Wall/Window Wall)
6'-0"
D.L.O.
SPANDREL
9'-0"
D.L.O.
VISION
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
5'-0"
D.L.O.
Vision Area
Example Glass U-factor
= 0.48 Btu/(ft2 · h · °F)
Vision Area
= 5(9 + 8 + 4) = 105.0 ft2
Total Area (Vision)
= 5' 2-1/2" (9' 3-3/4" + 8' 2-1/2" + 4' 2-1/2") = 113.2 ft2
Percentage of Vision Glass
= (Vision Area ÷ Total Area)100
= (105.0 ÷ 113.2)100 = 93%
Spandrel Area
Example Spandrel R-value
= 15 (ft2 · h · °F)/Btu
Spandrel Area
= 5(6 + 3) = 45.0 ft2
Total Area (Spandrel)
= 5' 2-1/2" (6' 2-1/2" + 3' 3-3/4") = 49.6 ft2
Percent of Spandrel
= (Spandrel Area ÷ Total Area)100
= (49.0 ÷ 49.6)100 = 91%
ADMD180
kawneer.com
© Kawneer Company, Inc., 2014
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
VISION
2-1/2" Typ.
3'-0"
D.L.O.
4'-0"
D.L.O.
VISION
31'-3"
SPANDREL
8'-0"
D.L.O.
2-1/2" Typ.
1630 SS IR
JULY, 2014
EC 97911-063
21
THERMAL CHARTS
Vision Area Chart
System U-factor vs Percent of Vision Area
(N
0.70
E IGN
PL S
M E
A D
EX OR
F
T
O
COG
U-factor
0.53
0.50
0.40
0.30
)
0.48
0.46
0.44
0.42
0.40
0.38
0.36
0.34
0.32
0.30
0.28
0.26
0.24
0.22
0.20
0.60
Btu
h·ft 2·°F
System U-factor
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
0.80
93%
0.20
95
85
90
75
80
70
Vision Area / Total Area (%)
Based on a single curtain wall bay of 93% vision glass and center
of glass U-factor of 0.48, System U-factor is equal to 0.53 Btu/(h·ft 2·°F)
System U-factor vs Percent of Spandrel Area
Spandrel
R-value
E IGN
PL S
M E
A D
EX OR
F
T
O
3.00
4.00
© Kawneer Company, Inc., 2014
5.00
0.30
0.21
0.20
0.10
91%
95
0.40
)
11.00
15.00
19.00
30.00
0.50
Btu
h·ft 2·°F
System U-factor
2.00
0.60
(N
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Spandrel Area Chart
90
85
80
75
70
Spandrel Area / Total Area (%)
Based on a single curtain wall bay of 91% spandrel and center of
spandrel R-value of 15, system U-factor is equal to 0.21 Btu/(h·ft 2·°F)
kawneer.com
ADMD180
22
1630 SS IR
JULY, 2014
THERMAL CHARTS
EC 97911-063
Note:
Values in parentheses are metric.
COG=Center of Glass.
Charts are generated per AAMA 507.
0.48 (2.73)
0.46 (2.61)
0.44 (2.50)
0.42 (2.39)
0.40 (2.27)
0.38 (2.16)
0.36 (2.05)
0.34 (1.93)
0.32 (1.82)
0.30 (1.71)
0.28 (1.59)
0.26 (1.48)
0.24 (1.37)
0.22 (1.25)
0.20 (1.14)
Vision Area / Total Area (%)
Notes for System U-Factor, SHGC and VT charts:
For glass values that are not listed, linear interpolation is permitted.
Glass properties are based on center of glass values (winter conditions) and are obtained
from your glass supplier.
ADMD180
kawneer.com
© Kawneer Company, Inc., 2014
COG
U-factor
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System U-Factor (Btu/h·ft2·°F)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
System U-Factor for Vision Glass
System VT
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System SHGC
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
JULY, 2014
COG
SHGC
COG
VT
kawneer.com
1630 SS IR
EC 97911-063
Vision Ares / Total Area (%)
Charts are generated per AAMA 507.
ADMD180
23
THERMAL CHARTS
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
Vision Area / Total Area (%)
Charts are generated per AAMA 507.
System Visible Transmittance (VT) vs Percent of Vision Area
1630 SS IR
JULY, 2014
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
EC 97911-063
Overall U-Factor 4
0.48
0.57
0.46
0.55
0.44
0.53
0.42
0.52
0.40
0.50
0.38
0.48
0.36
0.47
0.34
0.45
0.32
0.43
0.30
0.42
0.28
0.40
0.26
0.38
0.24
0.37
0.22
0.35
0.20
0.33
NOTE:For glass values that are not listed, linear
interpolation is permitted.
1.
2.
3.
4.
SHGC Matrix 2
U-Factors are determined in accordance with NFRC 100.
SHGC and VT values are determined in accordance with
NFRC 200.
Glass properties are based on center of glass values and
are obtained from your glass supplier.
Overall U-Factor, SHGC, and VT Matricies are based on
the standard NFRC specimen size of 2000mm wide by
2000mm high (78-3/4" by 78-3/4").
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.75
0.67
0.75
0.66
0.70
0.63
0.70
0.62
0.65
0.58
0.65
0.57
0.60
0.54
0.60
0.53
0.55
0.50
0.55
0.48
0.50
0.45
0.50
0.44
0.45
0.41
0.45
0.40
0.40
0.36
0.40
0.35
0.35
0.32
0.35
0.31
0.30
0.28
0.30
0.26
0.25
0.23
0.25
0.22
0.20
0.19
0.20
0.18
0.15
0.14
0.15
0.13
0.10
0.10
0.10
0.09
0.05
0.06
0.05
0.04
ADMD180
kawneer.com
© Kawneer Company, Inc., 2014
Glass U-Factor 3
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
24