1630 SS IR JULY, 2014 EC 97911-063 FEATURES Features • 1630 SS IR is an outside glazed captured curtain wall system • 1630 SS IR has a 3" (76.2 mm) sight line • Standard 7-13/16" (198.4 mm) or 8-13/16" (223.8 mm) depth systems • Infill 1-5/16" (33.3 mm) • Thermally Broken by means of a continuous 1/4" (6.4 mm) low conductance spacer • Perimeter seal can be installed at the pressure plate or mullion shoulder • Frame options available to accommodate design pressures from 70 psf to 130 psf • 1630 SS IR can be supplied fabricated and KD or in stock lengths • Dry Glazing and Wet Glazing option • Interlocking mullion design eliminates need for anti-buckling clips • Concealed fastener joinery creates smooth, monolithic appearance • EPDM gaskets and thermal break • Screw spline joinery method allows shop assembly of ladder sections, reducing field labor • Corners available with shear block fabrication method • Offers entrance framing systems • Silicone compatible glazing materials for long-lasting seals • Two color option • PermanodicTM anodized finishes in seven choices Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. • Painted finishes in standard and custom choices Additional Features* • Large Missile and Small Missile Hurricane Impact tested • Blast Mitigation tested Product Applications • Ideal for low-rise applications where high performance is desired • Most of the product assembly can be done in the shop rather than the field. This allows for better quality control and reduces expensive field labor. © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1 *See NOA product approval for specific features tested and approved for hurricane impact. For specific product applications, Consult your Kawneer representative. kawneer.com ADMD180 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1630 SS IR BLANK PAGE ADMD180 kawneer.com © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 JULY, 2014 EC 97911-063 1630 SS IR JULY, 2014 EC 97911-063 3 INDEX PICTORIAL VIEW................................................................................ 5 TYPICAL FRAMING DETAILS.........................................................6, 7 HURRICANE IMPACT RESISTANT ENTRANCE FRAMING DETAILS....................................................................8, 9 CORNER DETAILS....................................................................... 10-12 WINDOW INTEGRATION.................................................................. 13 ANCHORING................................................................................14, 15 WIND LOAD / DEADLOAD CHARTS........................................... 16-19 THERMAL CHARTS .................................................................... 20-24 LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR. © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Architects - Most extrusion and window types illustrated in this catalog are standard products for Kawneer. These concepts have been expanded and modified to afford you design freedom. Some miscellaneous details are non-standard and are intended to demonstrate how the system can be modified to expand design flexibility. Please contact your Kawneer representative for further assistance. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. The following metric (SI ) units are found in these details: m –meter cm – centimeter mm –millimeter s –second Pa –pascal MPa –megapascal Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement. kawneer.com ADMD180 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1630 SS IR BLANK PAGE ADMD180 kawneer.com © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 JULY, 2014 EC 97911-063 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JULY, 2014 1630 SS IR EC 97911-063 PICTORIAL VIEW kawneer.com ADMD180 5 OPTIONAL WET GLAZING 6 8 7 9 ENTRANCE DETAILS 4 7-13/16" (198.4) LARGE MISSILE (LMI) 8-13/16" (223.8) 1 HEAD 1 1A 3 2 HORIZONTAL CORNER DETAILS 5 5A ELEVATION IS NUMBER KEYED TO DETAILS TYPICAL ELEVATION 5 SILL ADMD180 kawneer.com © Kawneer Company, Inc., 2014 TYPICAL FRAMING DETAILS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1/2" (12.7) 1630 SS IR Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 3" (76.2) 6 JULY, 2014 EC 97911-063 SCALE 3" = 1'-0" 2 ANCHOR DETAILS © Kawneer Company, Inc., 2014 7-13/16" (198.4) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1/2" (12.7) 1/2" (12.7) 6 LEFT JAMB 8-13/16" DEEP kawneer.com 8-13/16" (223.8) 7-13/16" (198.4) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. JULY, 2014 1630 SS IR EC 97911-063 TYPICAL FRAMING DETAILS SCALE 3" = 1'-0" 3" (76.2) 6 LEFT JAMB 7-13/16" DEEP 3" (76.2) 8 VERTICAL 7-13/16" DEEP 6 RIGHT JAMB 7-13/16" DEEP 8 VERTICAL 8-13/16" DEEP 6 RIGHT JAMB 8-13/16" DEEP ADMD180 7 1630 SS IR 8 JULY, 2014 HURRICANE IMPACT RESISTANT ENTRANCE FRAMING DETAILS EC 97911-063 SCALE 3" = 1'-0" 7-13/16" (198.4) 1 2 3 1/8" (3.1) 1/8" (3.1) 2" (50.8) 2 3 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 3" (76.2) 1 ENTRANCE ELEVATION 5" (127) ELEVATION IS NUMBER KEYED TO DETAILS NOTE: DOORS SHOWN GLAZED WITH 9/16" INFILL OPTIONAL 1" DOOR INFILL LARGE MISSILE (LMI) 1" (25.4) 3" (76.2) 1" (25.4) 3" (76.2) 3 DOOR JAMB 2 DOOR JAMB CONTINUOUS HINGE LARGE MISSILE (LMI) BUTT HUNG OR OFFSET PIVOT LARGE MISSILE (LMI) ADMD180 kawneer.com © Kawneer Company, Inc., 2014 BUTT HUNG OR OFFSET PIVOT WITH SINGLE ACTING OFFSET ARM CONCEALED OVERHEAD CLOSER LARGE MISSILE (LMI) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1 TRANSOM BAR 1630 SS IR JULY, 2014 EC 97911-063 HURRICANE IMPACT RESISTANT ENTRANCE FRAMING DETAILS SCALE 3" = 1'-0" 8-13/16" (223.8) 7-13/16" (198.4) 3" (76.2) 1/8" (3.1) 2" (50.8) 2 3 ENTRANCE ELEVATION 5" (127) ELEVATION IS NUMBER KEYED TO DETAILS NOTE: DOORS SHOWN GLAZED WITH 9/16" INFILL 1 TRANSOM BAR BUTT HUNG OR OFFSET PIVOT WITH SINGLE ACTING OFFSET ARM CONCEALED OVERHEAD CLOSER LARGE MISSILE (LMI) © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1 2 3 1/8" (3.1) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1 3" (76.2) OPTIONAL 1" DOOR INFILL LARGE MISSILE (LMI) 1" (25.4) 3" (76.2) 3 DOOR JAMB 2 DOOR JAMB CONTINUOUS HINGE LARGE MISSILE (LMI) BUTT HUNG OR OFFSET PIVOT LARGE MISSILE (LMI) kawneer.com 1" (25.4) ADMD180 9 90° OUTSIDE CORNER 7-13/16" DEEP 90° OUTSIDE CORNER 8-13/16" DEEP 90° INSIDE CORNER 7-13/16" DEEP 90° INSIDE CORNER 8-13/16" DEEP Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1630 SS IR JULY, 2014 CORNER DETAILS EC 97911-063 ADMD180 kawneer.com © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 10 SCALE 3" = 1'-0" © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JULY, 2014 1630 SS IR EC 97911-063 CORNER DETAILS SCALE 3" = 1'-0" 135° OUTSIDE CORNER 7-13/16" DEEP kawneer.com 135° OUTSIDE CORNER 8-13/16" DEEP 135° INSIDE CORNER 7-13/16" DEEP ADMD180 11 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1630 SS IR JULY, 2014 CORNER DETAILS EC 97911-063 135° OUTSIDE CORNER 7-13/16" DEEP 135° OUTSIDE CORNER 8-13/16" DEEP ADMD180 kawneer.com © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 12 SCALE 3" = 1'-0" 135° INSIDE CORNER 8-13/16" DEEP © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JULY, 2014 kawneer.com 1630 SS IR EC 97911-063 WINDOW INTEGRATION SCALE 3" = 1'-0" Shown with AATM 900 IsoWebTM Window NOTE: Other vent types can be accommodated. Contact your Kawneer representative for other options. HEAD JAMB SILL ADMD180 13 1" (25.4) MINIMUM ANCHORING TO FLOOR SLAB 1" (25.4) MINIMUM ANCHORING TO SUPPORT STEEL ADMD180 kawneer.com © Kawneer Company, Inc., 2014 ANCHORING Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1630 SS IR Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 14 JULY, 2014 EC 97911-063 Actual project conditions will determine specific anchor design. Details on this page are for reference only. © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JULY, 2014 kawneer.com 1630 SS IR EC 97911-063 ANCHORING Actual project conditions will determine specific anchor design. Details on this page are for reference only. 1" (25.4) MINIMUM ANCHORING TO HORIZONTAL STRUCTURAL STEEL 1" (25.4) MINIMUM ANCHORING TO VERTICAL STRUCTURAL STEEL ADMD180 15 16 1630 SS IR JULY, 2014 WIND LOAD / DEADLOAD CHARTS EC 97911-063 DEAD LOAD CHARTS Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Horizontal or deadload limitations are based upon 1/8" (3.2), maximum allowable deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1" (25) thick insulating glass or 1/4" (6) thick glass supported on two setting blocks placed at the loading points shown. ADMD180 kawneer.com © Kawneer Company, Inc., 2014 Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4" above 13'-6". These curves are for mullions WITH HORIZONTALS and are based on engineering calculations for stress and deflection. Allowable wind load stress for ALUMINUM 15,152 psi (104MPa), STEEL 30,000 psi (207MPa.). Charted curves, in all cases are for the limiting value. If the design wind load is determined through the analytical procedures of ASCE/SEI 7-10 or earlier editions, the load shall be based on the nominal loads used in allowable stress design. A 4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your Kawneer representative for additional information. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. WIND LOAD CHARTS 1630 SS IR JULY, 2014 WIND LOAD CHARTS (1-5/16" INFILL) A = 60 PSF (2880) B = 75 PSF (3600) C = 90 PSF (4320) D = 110 PSF (5280) E = 130 PSF (6240) MULLION CENTERS IN METERS 2.0 17 29 11 10 3.0 7 A B C D 6 E 9 8 2.0 5 4 EQUAL 25 7.0 23 22 21 20 6.0 A 19 18 B 17 5.0 C 15 D E4.0 14 13 0 1 2 3 4 5 6 7 176001 8 176002 12 I = 15.354 (639.08 x 104) S = 4.413 (72.32 x 103) 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET SINGLE SPAN TWIN SPAN MULLION CENTERS IN METERS MULLION CENTERS IN METERS 1.0 2.0 18 30 17 29 10 C D E 9 8 7 2.0 6 5 4 1.0 3 EQUAL 27 24 21 4 5 6 7 8 MULLION CENTERS IN FEET kawneer.com 176003 176004 I = 24.511 (1020.22 x 104) S = 5.766 (94.49 x 103) ADMD180 B6.0 20 19 C 18 17 5.0 16 D 15 E 13 3 A 22 1 2 7.0 23 14 1 8.0 26 2 0 9.0 28 MULLION HEIGHT IN FEET A B3.0 11 2.0 25 EQUAL 12 MULLION HEIGHT IN METERS 4.0 13 MULLION HEIGHT 15 14 MULLION HEIGHT 5.0 16 MULLION HEIGHT IN FEET 24 16 1 0 8.0 26 2 0 9.0 27 1.0 3 2.0 28 MULLION HEIGHT IN FEET 12 MULLION HEIGHT IN METERS 4.0 13 EQUAL 14 MULLION HEIGHT 15 MULLION HEIGHT 5.0 1.0 © Kawneer Company, Inc., 2014 1.0 30 MULLION CENTERS IN FEET Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. MULLION CENTERS IN METERS 18 16 MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1.0 TWIN SPAN MULLION HEIGHT IN METERS SINGLE SPAN 12 4.0 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET MULLION HEIGHT IN METERS EC 97911-063 17 1630 SS IR JULY, 2014 WIND LOAD CHARTS (1-5/16" INFILL) A = 60 PSF (2880) B = 75 PSF (3600) C = 90 PSF (4320) D = 110 PSF (5280) E = 130 PSF (6240) 2.0 26 1.0 19 18 17 5.0 16 15 A 14 B 4.0 13 C 12 D E 11 10 9.0 A 29 28 27 26 B 24 C 23 7.0 22 D 20 6.0 E 19 3.0 8.0 25 21 9 18 0 1 2 3 4 5 6 7 8 176003 176004 With 176229 (1/2" x 5") Steel Bars 17 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET MULLION CENTERS IN FEET I = 24.511 (1020.22 x 104) S = 6.180 (101.27 x 103) Steel I = 5.208 (216.77x 104) S = 2.083 (34.13 x 103) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 8 31 MULLION HEIGHT IN FEET 6.0 10.0 32 30 EQUAL 20 MULLION HEIGHT IN METERS 21 MULLION HEIGHT 22 EQUAL 33 MULLION HEIGHT 34 24 7.0 2.0 35 25 23 MULLION HEIGHT IN FEET MULLION CENTERS IN METERS ADMD180 kawneer.com © Kawneer Company, Inc., 2014 MULLION CENTERS IN METERS TWIN SPAN Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SINGLE SPAN 1.0 EC 97911-063 MULLION HEIGHT IN METERS 18 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. GLASS HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1.0 13 11 12 10 kawneer.com 9 0 3.0 8 7 A 6 2.0 5 4 3 1.0 1 2 3 4 5 6 7 GLASS HEIGHT IN METERS JULY, 2014 1630 SS IR EC 97911-063 DEADLOAD CHARTS (1-5/16" INFILL) SPAN IN METERS 16 2.0 15 A = 1/4 POINT LOADING B = 1/8 POINT LOADING 14 B 4.0 I = 3.334 (138.77 x 104) S = 2.222 (36.41 x 103) 176007 2 1 SPAN IN FEET 8 ADMD180 19 1630 SS IR 20 JULY, 2014 THERMAL CHARTS EC 97911-063 Generic Project Specific U-factor Example Calculation (Percent of Glass will vary on specific products depending on sitelines) (Based on single bay of Curtain Wall/Window Wall) 6'-0" D.L.O. SPANDREL 9'-0" D.L.O. VISION Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 5'-0" D.L.O. Vision Area Example Glass U-factor = 0.48 Btu/(ft2 · h · °F) Vision Area = 5(9 + 8 + 4) = 105.0 ft2 Total Area (Vision) = 5' 2-1/2" (9' 3-3/4" + 8' 2-1/2" + 4' 2-1/2") = 113.2 ft2 Percentage of Vision Glass = (Vision Area ÷ Total Area)100 = (105.0 ÷ 113.2)100 = 93% Spandrel Area Example Spandrel R-value = 15 (ft2 · h · °F)/Btu Spandrel Area = 5(6 + 3) = 45.0 ft2 Total Area (Spandrel) = 5' 2-1/2" (6' 2-1/2" + 3' 3-3/4") = 49.6 ft2 Percent of Spandrel = (Spandrel Area ÷ Total Area)100 = (49.0 ÷ 49.6)100 = 91% ADMD180 kawneer.com © Kawneer Company, Inc., 2014 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. VISION 2-1/2" Typ. 3'-0" D.L.O. 4'-0" D.L.O. VISION 31'-3" SPANDREL 8'-0" D.L.O. 2-1/2" Typ. 1630 SS IR JULY, 2014 EC 97911-063 21 THERMAL CHARTS Vision Area Chart System U-factor vs Percent of Vision Area (N 0.70 E IGN PL S M E A D EX OR F T O COG U-factor 0.53 0.50 0.40 0.30 ) 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 0.60 Btu h·ft 2·°F System U-factor Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 0.80 93% 0.20 95 85 90 75 80 70 Vision Area / Total Area (%) Based on a single curtain wall bay of 93% vision glass and center of glass U-factor of 0.48, System U-factor is equal to 0.53 Btu/(h·ft 2·°F) System U-factor vs Percent of Spandrel Area Spandrel R-value E IGN PL S M E A D EX OR F T O 3.00 4.00 © Kawneer Company, Inc., 2014 5.00 0.30 0.21 0.20 0.10 91% 95 0.40 ) 11.00 15.00 19.00 30.00 0.50 Btu h·ft 2·°F System U-factor 2.00 0.60 (N Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Spandrel Area Chart 90 85 80 75 70 Spandrel Area / Total Area (%) Based on a single curtain wall bay of 91% spandrel and center of spandrel R-value of 15, system U-factor is equal to 0.21 Btu/(h·ft 2·°F) kawneer.com ADMD180 22 1630 SS IR JULY, 2014 THERMAL CHARTS EC 97911-063 Note: Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. 0.48 (2.73) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) Vision Area / Total Area (%) Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. ADMD180 kawneer.com © Kawneer Company, Inc., 2014 COG U-factor Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System U-Factor (Btu/h·ft2·°F) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System U-Factor for Vision Glass System VT © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JULY, 2014 COG SHGC COG VT kawneer.com 1630 SS IR EC 97911-063 Vision Ares / Total Area (%) Charts are generated per AAMA 507. ADMD180 23 THERMAL CHARTS System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area Vision Area / Total Area (%) Charts are generated per AAMA 507. System Visible Transmittance (VT) vs Percent of Vision Area 1630 SS IR JULY, 2014 THERMAL PERFORMANCE MATRIX (NFRC SIZE) EC 97911-063 Overall U-Factor 4 0.48 0.57 0.46 0.55 0.44 0.53 0.42 0.52 0.40 0.50 0.38 0.48 0.36 0.47 0.34 0.45 0.32 0.43 0.30 0.42 0.28 0.40 0.26 0.38 0.24 0.37 0.22 0.35 0.20 0.33 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.67 0.75 0.66 0.70 0.63 0.70 0.62 0.65 0.58 0.65 0.57 0.60 0.54 0.60 0.53 0.55 0.50 0.55 0.48 0.50 0.45 0.50 0.44 0.45 0.41 0.45 0.40 0.40 0.36 0.40 0.35 0.35 0.32 0.35 0.31 0.30 0.28 0.30 0.26 0.25 0.23 0.25 0.22 0.20 0.19 0.20 0.18 0.15 0.14 0.15 0.13 0.10 0.10 0.10 0.09 0.05 0.06 0.05 0.04 ADMD180 kawneer.com © Kawneer Company, Inc., 2014 Glass U-Factor 3 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 24