7500 Wall

7500 Wall
®
A Marriage of Energy Savings
and Design Freedom
PCL Centennial Learning Centre, Edmonton, Alberta, Canada
Architects: Cohos Evamy integratedesign™, Edmonton, Alberta, Canada
Glazing Contractor: Beacon Glass Products Ltd., St. Albert, Alberta, Canada
Kawneer’s 7500 Wall® offers uncompromising design with
uncompromising energy efficiency. It is the complete performer in
all conditions, whether the application is a curtain wall, ground floor
framing or strip windows. With the flexibility of a three-piece
system, it provides design freedom and dual finish options. Thermal
breaks and double or triple glazing options provide a real reduction
in energy usage and significant savings in HVAC capital costs.
Performance
A high-performance system like this sets the pace in curtain wall
technology and leads the way as an energy efficient product. It has
been designed and developed for applications where the primary
concerns are energy efficiency and reduced payback time periods.
A 24 mm and 49 mm ISOWEB® glass-reinforced nylon thermal break
provides rigid profiles with composite structural performance. The
7525 framing accommodates 1" (25.4) high performance double
sealed units and 7550 framing accommodates 2" (50.8) high
performance triple sealed units. 7500 Wall®, with a fully pressure
equalized, rain screen design, also has an EPDM sponge interior and
EPDM rubber exterior gaskets (dry/dry glazing).
7500 Wall® system has been tested and certified to meet the
following standards:
• Air infiltration per ASTM E283 < 0.06 cfm/ft2, pressure differential
of 6.24 psf (300 Pa)
• Water penetration per ASTM E547 no water infiltration with a
pressure differential of 15 psf (720 Pa)
• Thermal transmittance per AAMA 1503 up to 0.17 BTU/hr x ft2 x °F
(0.98 W/m2 x °C)
• 7550 Wall with triple glazing offers a CRFf = 85 and CRFg = 80
• Improved condensation temperature index I value
• Meets or exceeds the highest levels of CSA standard CAN/
CSA-A440 Windows
Aesthetics
The 7500 Wall® system combines slim sightlines with an overall
aesthetically pleasing appearance. The system is ideal for storefronts,
strip windows, window/wall or curtain wall applications.
A 4" (101.6) standard mullion depth and a narrow 2-1/2" (63.5)
sightline are characteristic of the 7500 Wall®. It offers greater design
flexibility with the options to select a grid pattern type, different
product finishes, various glass types and choice of spandrel infills. All
infill materials are glazed from the exterior and held in place with
mechanically fastened continuous pressure plates. The system is also
compatible for use with Insulclad® doors.
Tubular mullions and
transoms with shear
block construction.
Pressure equalized rain
screen design. Highperformance ISOWEB®
glass reinforced nylon
thermal break.
7550 Wall shown,
7525 Wall similar.
Note: Numbers in parentheses ( ) are millimeters unless otherwise noted.
Kawneer Company, Inc.
Technology Park / Atlanta
555 Guthridge Court
Norcross, GA 30092
© Kawneer Company, Inc. 2011
kawneer.com
kawneergreen.com
770 . 449 . 5555
LITHO IN U.S.A.
Form No. 11-2136
University of Alaska Museum of the North, Fairbanks, AK
Architects: GDM Inc., Anchorage, AK; Hammel, Green and Abrahamson, Inc.
(HGA), Minneapolis, MN
Glazing Contractor: Commercial Contractors, Inc., Anchorage, AK
For the Finishing Touch
Permanodic® Anodized finishes are available in Class I and Class II in
seven different color choices.
Painted finishes, including fluoropolymer, that meet AAMA 2605 are
offered in many standard choices and an unlimited number of
specially-designed colors.
Solvent-free powder coatings add the green element with high
performance, durability and scratch resistance that meet the
standards of AAMA 2604.
7500 WALLTM
DECEMBER, 2013
FEATURES
Features
• High performance curtain wall, ground-floor framing and entrance system, or
horizontal strip window
• 24mm and 49mm IsoWebTM glass-reinforced nylon thermal break provides:
•
•
•
•
•
•
•
•
•
•
- Excellent condensation resistance
- Ultra low thermal transmittance U-values
- Rigid profiles with composite structural performance
7525 framing accommodates 25mm high performance double sealed units
7550 framing accommodates 50mm high performance triple sealed units
EPDM sponge interior and EPDM rubber exterior gaskets (dry/dry glazing)
Meets or exceeds the highest levels of CSA standard CAN/CSA-A440) Windows
and AAMA 507
Fully pressure equalized, rain screen design
Simple stick, shear block, pressure plate construction
Door adaptors for thermal entrances
Two color option
PermanodicTM anodized finishes in seven choices
Painted finishes in standard and custom choices
© Kawneer Company, Inc., 2013
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-053
For specific product applications,
Consult your Kawneer representative.
kawneer.com
ADMD110
1
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
7500 WALLTM
BLANK PAGE
ADMD110
kawneer.com
© Kawneer Company, Inc., 2013
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
2
DECEMBER, 2013
EC 97911-053
7500 WALLTM
DECEMBER, 2013
EC 97911-053
3
INDEX
PICTORIAL VIEW................................................................................. 5
CURTAIN WALL - GRID WALL.......................................................... 6-7
ALUMINUM SHEER PANELS........................................................... 8-9
ALUMINUM FLUSH PANELS........................................................ 10-11
ENTRANCE DETAILS........................................................................ 12
CORNER DETAILS............................................................................. 13
WIND LOAD CHARTS................................................................... 14-17
THERMAL CHARTS...................................................................... 18-24
LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED
ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT
CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR
GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR.
Metric (SI) conversion figures are included throughout these details for reference.
Numbers in parentheses ( ) are millimeters unless otherwise noted.
The following metric (SI) units are found in these details:
m –meter
cm – centimeter
mm –millimeter
s –second
Pa –pascal
MPa –megapascal
© Kawneer Company, Inc., 2013
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Architects – Most extrusion and window types illustrated in this catalog are standard products for Kawneer. These concepts have been expanded
and modified to afford you design freedom. Some miscellaneous details are non-standard and are intended to demonstrate how the system can be
modified to expand design flexibility. Please contact your Kawneer representative for further assistance.
Kawneer reserves the right to change configurations without prior notice when deemed necessary
for product improvement.
kawneer.com
ADMD110
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
7500 WALLTM
BLANK PAGE
ADMD110
kawneer.com
© Kawneer Company, Inc., 2013
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
4
DECEMBER, 2013
EC 97911-053
© Kawneer Company, Inc., 2013
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DECEMBER, 2013
kawneer.com
7500 WALLTM
EC 97911-053
PICTORIAL VIEW
7500 WALLTM
Tubular mullions and transoms
with shear block construction.
Pressure equalized rain screen design.
High performance IsoWebTM glass
reinforced nylon thermal break.
7550 Wall shown, 7525 Wall similar.
ADMD110
5
1
JAMB
2
MULLION
824024
2-1/2"
(63.5)
824011
ADMD110
Floor Slab
ELEVATION IS NUMBER KEYED TO DETAILS
7550 - 50mm TRIPLE GLAZED
824201
1
JAMB
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Floor to Floor
CURTAIN WALL - GRID WALL
824313
824024
824313
2-1/2"
(63.5)
2
MULLION
824011
2-1/2"
(63.5)
2-1/2"
(63.5)
kawneer.com
© Kawneer Company, Inc., 2013
7525 - 25mm DOUBLE GLAZED
Mullion Length
Spandrel
Panel
7500 WALLTM
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
2
7-5/16"
(185.7)
5
Vision Panel
2
(Typ.)
Spandrel
Panel
4
4"
(101.6)
824211
(Typ.)
1
6-5/16"
(160.3)
4"
(101.6)
6
DECEMBER, 2013
EC 97911-053
SCALE 3" = 1'-0"
3
Floor Slab
kawneer.com
1/2"
Construction joint
(Allows ± 1/4" movement) (12.7)
824302
3
SILL - VISION PANEL
1/2"
Construction joint
(Allows ± 1/4" movement) 12.7
824211
5
HEAD - VISION PANEL
ADMD110
824311
824004
824311
824004
Mullion Length
7525 - 25mm DOUBLE GLAZED
824313
Mullion Length
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-053
824024
2-1/2"
(63.5)
824313
824024
2-1/2"
(63.5)
© Kawneer Company, Inc., 2013
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
DECEMBER, 2013
7500 WALLTM
CURTAIN WALL - GRID WALL
SCALE 3" = 1'-0"
7550 - 50mm TRIPLE GLAZED
6-5/16"
(160.3)
7-5/16"
(185.7)
Sleeve
Sleeve
824212
824202
824301
3
SILL - VISION PANEL
Floor Slab
4
ANCHOR
824201
5
HEAD - VISION PANEL
7
2-1/2"
(63.5)
824024
824305
1
MULLION
ADMD110
ELEVATION IS NUMBER KEYED TO DETAILS
7550 - 50mm TRIPLE GLAZED
824211
824304
2-1/2"
(63.5)
824024
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Floor Slab
824313
824305
824313
1
MULLION
kawneer.com
© Kawneer Company, Inc., 2013
7525 - 25mm DOUBLE GLAZED
Floor to Floor
4
Spandrel
Panel
3
Mullion Length
Vision Panel
ALUMINUM SHEER PANELS
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
7-5/16"
(185.7)
4"
(101.6)
Spandrel
Panel
7500 WALLTM
1/8"
(3.2)
824304
6-5/16"
(160.3)
1
1/8"
(3.2)
4"
(101.6)
8
DECEMBER, 2013
EC 97911-053
SCALE 3" = 1'-0"
2
Floor Slab
824201
kawneer.com
2-1/2"
(63.5)
2-1/2"
(63.5)
© Kawneer Company, Inc., 2013
Mullion Length
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
1/2"
Construction joint
(Allows ± 1/4" movement) (12.7)
1/8"
(3.2)
824012
2
SILL - VISION PANEL
1/2"
Construction joint
(Allows ± 1/4" movement) (12.7)
Mullion Length
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DECEMBER, 2013
7500 WALLTM
EC 97911-053
ALUMINUM SHEER PANELS
SCALE 3" = 1'-0"
7525 - 25mm DOUBLE GLAZED
7550 - 50mm TRIPLE GLAZED
6-5/16"
(164.3)
1/8"
(3.2)
824212
824009
824302
216646
824007
824211
4
HEAD - VISION PANEL
ADMD110
7-5/16"
(185.7)
Sleeve
Sleeve
824012
824202
824009
824302
2
SILL - VISION PANEL
216027
216027
3
PANEL STIFFENER
3
PANEL STIFFENER
216646
824007
824201
4
HEAD - VISION PANEL
9
824313
4
7525 - 25mm DOUBLE GLAZED
824211
824024
2-1/2"
(63.5)
1
MULLION
ADMD110
Floor Slab
ELEVATION IS NUMBER KEYED TO DETAILS
7550 - 50mm TRIPLE GLAZED
824008
824313
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Floor to Floor
1
Spandrel
Panel
3
Mullion Length
Vision Panel
ALUMINUM FLUSH PANELS
824011
824011
824008
824024
2-1/2"
(63.5)
1
MULLION
kawneer.com
© Kawneer Company, Inc., 2013
Spandrel
Panel
7500 WALLTM
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
7-5/16"
(185.7)
4"
(101.6)
6-5/16"
(160.3)
4"
(101.6)
10
DECEMBER, 2013
EC 97911-053
SCALE 3" = 1'-0"
2
Floor Slab
824201
kawneer.com
1/2"
Construction joint
(Allows ± 1/4" movement) (12.7)
824302
824008
2
SILL - VISION PANEL
1/2"
Construction joint
(Allows ± 1/4" movement) (12.7)
824008
824008
824211
4
HEAD - VISION PANEL
ADMD110
824311
824004
824311
824004
Mullion Length
7525 - 25mm DOUBLE GLAZED
824313
Mullion Length
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-053
824024
2-1/2"
(63.5)
824313
824024
2-1/2"
(63.5)
© Kawneer Company, Inc., 2013
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
DECEMBER, 2013
7500 WALLTM
ALUMINUM FLUSH PANELS
SCALE 3" = 1'-0"
7550 - 50mm TRIPLE GLAZED
6-5/16"
(160.3)
7-5/16"
(185.7)
Sleeve
Sleeve
824212
824202
824008
824301
2
SILL - VISION PANEL
824008
3
PANEL STIFFENER
3
PANEL STIFFENER
824008
824011
824011
824201
4
HEAD - VISION PANEL
11
Overall frame height
1
Overall frame width
3
11/16"
(17.5)
069177
1/8"
(3.2)
824220
069177
824313
824024
3/32"
(2.4)
824028
824333
Door opening
width
3/32"
(2.4)
1
DOOR JAMB
OFFSET PIVOT OR BUTT HUNG
2-1/2"
(63.5)
6-5/16"
(160.3)
824211
824220
2
DOOR TRANSOM
2
Door opening
width
ADMD110
1"
(25.4)
Door opening
width
1
DOOR JAMB
OFFSET PIVOT OR BUTT HUNG
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
7500 WALLTM
DECEMBER, 2013
ENTRANCE DETAILS
EC 97911-053
824201
069177
824220
2
DOOR TRANSOM
3
THRESHOLD (7525 and 7550)
kawneer.com
© Kawneer Company, Inc., 2013
824220
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
7-5/16"
(185.7)
824211
824333
6-5/16"
(160.3)
7525 - 25mm DOUBLE GLAZED
824028
2-1/2"
(63.5)
1"
(25.4)
1"
(25.4)
824313
824024
2-1/2"
(63.5)
2-1/2"
(63.5)
Door opening height
1"
(25.4)
069177
Door opening height
1/8"
(3.2)
Door opening
height
12
SCALE 3" = 1'-0"
7550 - 50mm TRIPLE GLAZED
824201
7-5/16"
(185.7)
kawneer.com
824011
162258
827825
2-1/2"
(63.5)
824024
VISION
ADMD110
824011
EC 97911-053
90° OUTSIDE CORNERS
6-5/16"
(160.3)
824213
824203
824024
VISION
7-19/32"
(192.9)
7-5/16"
(185.7)
824011
7500 WALLTM
2-1/2"
(63.5)
90°
CL
162258
824225
824313
824024
824313
2-1/2"
(63.5)
VISION
8-19/32"
(218.3)
824024
824313
SPANDREL
824010
824024
2-1/2"
(63.5)
824011
7525 - 25mm DOUBLE GLAZED
824313
162255
SPANDREL
6-5/16"
(160.3)
824313
824024
2-1/2"
(63.5)
SPANDREL
CL
2-1/2"
(63.5)
SPANDREL
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
2-1/2"
(63.5)
7-19/32"
(192.9)
824313
824024
2-1/2"
(63.5)
© Kawneer Company, Inc., 2013
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
DECEMBER, 2013
13
CORNER DETAILS
SCALE 3" = 1'-0"
7550 - 50mm TRIPLE GLAZED
90° OUTSIDE CORNERS
7-5/16"
(185.7)
CL
824010
824313
824313
824024
VISION
8-19/32"
(218.3)
90°
CL
162255
DECEMBER, 2013
WIND LOAD CHARTS
EC 97911-053
Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4"
above 13'-6". These curves are for mullions WITH HORIZONTALS and are based on engineering calculations for stress
and deflection. Allowable wind load stress for ALUMINUM 15,152 psi (104MPa), STEEL 30,000 psi (207MPa.). Charted
curves, in all cases are for the limiting value. If the design wind load is determined through the analytical procedures
of ASCE/SEI 7-10 or earlier editions, the load shall be based on the nominal loads used in allowable stress design. A
4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these
curves, contact your Kawneer representative for additional information.
A = 20 PSF (960)
B = 30 PSF (1440)
C = 40 PSF (1920)
D = 50 PSF (2400)
E = 60 PSF (2880)
15
15
11
10
3.0
A
9
8
METERS
12
B
824211
7
2.0
6
1
2
3
4
5
6
7
8
A
12
11
B
10
3.0
9
C
8
7
D
6
E
2.0
C
D
E
824214
5
0
SINGLE SPAN
1
2
2.0
20
14
19
12
11
B
10
3.0
9
8
D
E
7
2.0
6
824205
4
8
5
6
7
824205
W/162300
8
2.0
6.0
17
C
3
7
18
MULLION HEIGHT IN FEET
A
7-5/16" (185.7)
4.0
13
7-5/16" (185.7)
15
2
6
1.0
21
METERS
MULLION HEIGHT IN FEET
1.0
1
5
METERS
16
0
4
SINGLE SPAN
METERS
5
3
MULLION CENTERS IN FEET
MULLION HEIGHT
MULLION CENTERS IN FEET
4.0
13
5.0
16
15
A
14
4.0
13
12
11
B
10
3.0
9
MULLION CENTERS IN FEET
C
8
WINDLOAD CHARTS ARE BASED ON
COMPOSITE PROPERTIES WHICH
ARE CALCULATED IN ACCORDANCE
WITH AAMA TIR-8 AND AAMA 505
ADMD110
METERS
0
MULLION HEIGHT IN FEET
13
14
7-9/16" (192.1)
4.0
6-5/16" (160.3)
16
5
2.0
1.0
16
14
MULLION HEIGHT IN FEET
METERS
2.0
1.0
D
E2.0
7
6
0
1
2
3
4
5
6
7
8
MULLION CENTERS IN FEET
kawneer.com
© Kawneer Company, Inc., 2013
METERS
SINGLE SPAN
METERS
SINGLE SPAN
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
7500 WALLTM
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
14
7500 WALLTM
EC 97911-053
WIND LOAD CHARTS
A = 20 PSF (960)
B = 30 PSF (1440)
C = 40 PSF (1920)
D = 50 PSF (2400)
E = 60 PSF (2880)
SINGLE SPAN
METERS
1.0
1.0
20
6.0
15
A
14
4.0
13
17
METERS
5.0
16
12
11
824205
W/162301/302
824205
W/162301
B
10
3.0
MULLION HEIGHT
D
E2.0
7
1
0
2
3
4
5
6
7
15
A
14
4.0
13
12
11
B
10
3.0
9
C
8
5.0
16
8
MULLION CENTERS IN FEET
C
8
D
E2.0
7
6
0
1
2
3
METERS
2.0
21
20
6.0
7-5/16" (185.7)
19
17
5.0
16
15
A
14
4.0
13
WINDLOAD CHARTS ARE BASED ON
COMPOSITE PROPERTIES WHICH
ARE CALCULATED IN ACCORDANCE
WITH AAMA TIR-8 AND AAMA 505
METERS
MULLION HEIGHT IN FEET
© Kawneer Company, Inc., 2013
18
12
11
B
10
3.0
9
824205
W/162301/302/303
C
8
D
E2.0
7
1
0
2
3
4
5
6
7
8
MULLION CENTERS IN FEET
kawneer.com
ADMD110
5
6
7
MULLION CENTERS IN FEET
SINGLE SPAN
1.0
4
8
METERS
17
18
MULLION HEIGHT IN FEET
18
6.0
19
7-5/16" (185.7)
7-5/16" (185.7)
19
6
2.0
21
9
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
METERS
2.0
20
6
15
SINGLE SPAN
21
MULLION HEIGHT IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DECEMBER, 2013
DECEMBER, 2013
WIND LOAD CHARTS
EC 97911-053
A = 20 PSF (960)
B = 30 PSF (1440)
C = 40 PSF (1920)
D = 50 PSF (2400)
E = 60 PSF (2880)
2.0
16
15
15
A
10
3.0
MULLION HEIGHT IN FEET
11
METERS
12
14
8-9/16" (217.5)
4.0
13
7-5/16" (185.7)
14
9
B
8
C
2.0
D
E
7
6
5
0
1
2
3
4
5
6
7
4.0
13
A
12
B
11
10
3.0
C
9
D
E
8
7
2.0
6
824201
5
8
824215
0
SINGLE SPAN
1
2
2.0
15
20
14
19
B
10
3.0
C
9
MULLION HEIGHT IN FEET
12
11
D
E
8
7
2.0
6
4
7
8
5
6
7
8
824204
824204
W/162300
MULLION CENTERS IN FEET
2.0
6.0
18
8-5/16" (211.1)
A
8-5/16" (211.1)
4.0
13
3
6
1.0
21
METERS
MULLION HEIGHT IN FEET
1.0
2
5
METERS
16
1
4
SINGLE SPAN
METERS
0
3
MULLION CENTERS IN FEET
MULLION HEIGHT
MULLION CENTERS IN FEET
5
2.0
1.0
16
17
5.0
16
A
15
14
4.0
13
12
B
11
10
3.0
C
9
D
E
8
7
2.0
WINDLOAD CHARTS ARE BASED ON
COMPOSITE PROPERTIES WHICH
ARE CALCULATED IN ACCORDANCE
WITH AAMA TIR-8 AND AAMA 505
ADMD110
6
0
1
2
3
4
5
6
7
8
MULLION CENTERS IN FEET
kawneer.com
© Kawneer Company, Inc., 2013
1.0
MULLION HEIGHT IN FEET
METERS
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
METERS
SINGLE SPAN
METERS
SINGLE SPAN
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
7500 WALLTM
METERS
16
7500 WALLTM
EC 97911-053
WIND LOAD CHARTS
A = 20 PSF (960)
B = 30 PSF (1440)
C = 40 PSF (1920)
D = 50 PSF (2400)
E = 60 PSF (2880)
SINGLE SPAN
METERS
1.0
1.0
2.0
21
20
6.0
18
18
14
4.0
13
17
12
B
11
10
3.0
824204
W/162301
C
D
E
2.0
1
2
3
4
5
6
7
5.0
16
A
15
14
4.0
13
12
B
11
10
3.0
C
9
D
E
8
7
0
824204
W/162301/302
MULLION HEIGHT
8
6.0
8
MULLION CENTERS IN FEET
SINGLE SPAN
7
2.0
6
0
1
2
3
4
5
2.0
21
20
6.0
5.0
A
15
14
4.0
13
METERS
MULLION HEIGHT IN FEET
© Kawneer Company, Inc., 2013
17
16
8-5/16" (211.1)
19
18
WINDLOAD CHARTS ARE BASED ON
COMPOSITE PROPERTIES WHICH
ARE CALCULATED IN ACCORDANCE
WITH AAMA TIR-8 AND AAMA 505
12
B
11
10
3.0
C
9
D
E
8
824204
W/162301/302/303
7
2.0
6
0
1
2
3
4
5
6
7
8
MULLION CENTERS IN FEET
kawneer.com
ADMD110
7
MULLION CENTERS IN FEET
METERS
1.0
6
8
METERS
A
15
METERS
5.0
MULLION HEIGHT IN FEET
17
16
8-5/16" (211.1)
19
8-5/16" (211.1)
19
9
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
METERS
2.0
20
6
17
SINGLE SPAN
21
MULLION HEIGHT IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DECEMBER, 2013
7500 WALLTM
18
DECEMBER, 2013
THERMAL CHARTS
EC 97911-053
Project Specific U-Factor
Example Calculation
15'-8" Frame Width
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
2'-0"
D.L.O.
9'-6" Frame Height
7'-0" D.L.O.
5'-0" D.L.O.
= 0.42 Btu/(ft2·h·°F)
Example Glass U-Factor
Total Daylight (Vision) Area = 3(5' x 7') + 3(5' x 2') = 135 ft2
Projected Total Area = 15'-8" x 9'-6" = 148.83 ft2
Percent of Vision Glass
= (Total Daylight Area ÷ Projected Total Area)100
= (135 ÷ 148.83)100 = 91%
System U-factor vs Percent of Glass Area
E IGN
PL S
M E
A D
EX OR
F
T
O
N
0.48
0.46
0.44
0.42
0.40
0.38
0.36
0.34
0.32
0.30
0.28
0.26
0.24
0.22
0.20
0.50
0.49
Btu
hr • ft2 • °F
System U-factor
COG
U-factor
0.60
0.40
70
75
80
85
0.20
90
91%
95
0.30
Percent of Glass Area
Based on 66% glass and center of glass (COG) U-factor of 0.42
System U-factor is equal to 0.53 Btu/hr • ft2 • °F
ADMD110
kawneer.com
© Kawneer Company, Inc., 2013
0.70
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
0.80
7500 WALLTM
DECEMBER, 2013
EC 97911-053
THERMAL CHARTS
7525 Wall (Double Glazed)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Note:
Values in parentheses are metric.
COG = Center of Glass.
Charts are generated per AMMA 507
Btu
hr • ft2 • °F
System U-factor
System U-factor vs Percent of Glass Area
© Kawneer Company, Inc., 2013
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
COG
U-factor
Percent of Glass Area = Vision Area/Total Area
Daylight Opening / Projected Area
Notes for System U-factor, SHGC and VT charts:
For glass values that are not listed, linear interpolation is permitted.
Glass properties are based on center of glass values and are obtained from your glass supplier.
kawneer.com
ADMD110
19
COG
SHGC
Vision Area / Total Area (%)
System Visible Transmittance (VT) vs Percent of Vision Area
COG
VT
Vision Area / Total Area (%)
ADMD110
kawneer.com
© Kawneer Company, Inc., 2013
THERMAL CHARTS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
System SHGC
7500 WALLTM
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System VT
20
DECEMBER, 2013
EC 97911-053
7525 Wall (Double Glazed)
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
7500 WALLTM
DECEMBER, 2013
EC 97911-053
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
7525 Wall (Double Glazed)
Thermal Transmittance1 (BTU/hr • ft 2 • °F)
Overall U-Factor 4
0.48
0.54
0.46
0.52
0.44
0.51
0.42
0.49
0.40
0.47
0.38
0.46
0.36
0.44
0.34
0.42
0.32
0.41
0.30
0.39
0.28
0.37
0.26
0.36
0.24
0.34
0.22
0.33
0.20
0.31
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Glass U-Factor 3
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.75
0.68
0.75
0.67
0.70
0.64
0.70
0.63
0.65
0.59
0.65
0.58
0.60
0.55
0.60
0.54
0.55
0.50
0.55
0.49
0.50
0.46
0.50
0.45
0.45
0.41
0.45
0.40
0.40
0.37
0.40
0.36
0.35
0.32
0.35
0.31
0.30
0.28
0.30
0.27
0.25
0.23
0.25
0.22
0.20
0.19
0.20
0.18
0.15
0.14
0.15
0.13
0.10
0.10
0.10
0.09
0.05
0.05
0.05
0.04
© Kawneer Company, Inc., 2013
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
SHGC Matrix 2
NOTE: For glass values that are not listed, linear interpolation is permitted.
1. U-Factors are determined in accordance with NFRC 100.
2. SHGC and VT values are determined in accordance with NFRC 200.
3. Glass properties are based on center of glass values and are obtained from your glass supplier.
4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of
2000mm wide by 2000mm high (78-3/4" by 78-3/4").
kawneer.com
ADMD110
21
7500 WALLTM
DECEMBER, 2013
EC 97911-053
THERMAL CHARTS
7550 Wall (Triple Glazed)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Note:
Values in parentheses are metric.
COG = Center of Glass.
Charts are generated per AMMA 507
System U-factor vs Percent of Glass Area
Percent of Glass Area = Vision Area/Total Area
Daylight Opening / Projected Area
Notes for System U-factor, SHGC and VT charts:
For glass values that are not listed, linear interpolation is permitted.
Glass properties are based on center of glass values and are obtained from your glass supplier.
ADMD110
kawneer.com
© Kawneer Company, Inc., 2013
COG
U-factor
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Btu
hr • ft2 • °F
System U-factor
22
System VT
© Kawneer Company, Inc., 2013
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System SHGC
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DECEMBER, 2013
kawneer.com
7500 WALLTM
EC 97911-053
Vision Area / Total Area (%)
ADMD110
23
THERMAL CHARTS
7550 Wall (Triple Glazed)
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
COG
SHGC
Vision Area / Total Area (%)
System Visible Transmittance (VT) vs Percent of Vision Area
COG
VT
7500 WALLTM
DECEMBER, 2013
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
EC 97911-053
Glass U-Factor 3
Overall U-Factor 4
0.36
0.43
0.34
0.41
0.32
0.39
0.30
0.37
0.28
0.36
0.26
0.34
0.24
0.32
0.22
0.31
0.20
0.29
0.18
0.27
0.16
0.26
0.14
0.24
0.12
0.22
0.10
0.21
0.08
0.19
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.75
0.68
0.75
0.67
0.70
0.64
0.70
0.63
0.65
0.59
0.65
0.58
0.60
0.55
0.60
0.54
0.55
0.50
0.55
0.49
0.50
0.46
0.50
0.45
0.45
0.41
0.45
0.40
0.40
0.37
0.40
0.36
0.35
0.32
0.35
0.31
0.30
0.28
0.30
0.27
0.25
0.23
0.25
0.22
0.20
0.19
0.20
0.18
0.15
0.14
0.15
0.13
0.10
0.10
0.10
0.09
0.05
0.05
0.05
0.04
NOTE: For glass values that are not listed, linear interpolation is permitted.
1. U-Factors are determined in accordance with NFRC 100.
2. SHGC and VT values are determined in accordance with NFRC 200.
3. Glass properties are based on center of glass values and are obtained from your glass supplier.
4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of
2000mm wide by 2000mm high (78-3/4" by 78-3/4").
ADMD110
kawneer.com
© Kawneer Company, Inc., 2013
SHGC Matrix 2
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
7550 Wall (Triple Glazed)
Thermal Transmittance1 (BTU/hr • ft 2 • °F)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
24