1600 Wall System™2 - Architectural Detail Manual

DECEMBER, 2015
1600 Wall SystemTM2 Curtain Wall
FEATURES
Features
• 1600 Wall SystemTM2 is an outside glazed structurally silicone glazed curtain wall
• 1600 Wall SystemTM2 has a 2-1/2" (63.5) sight line
• Standard 6" (152.4) or 7-1/2" (190.5) depth systems
• Standard infill options 1/4" (6.4) and 1" (25.4), other infills available
• Thermally Broken by means of a continuous 1/4" (6.4) low conductance spacer
• Concealed fastener joinery creates smooth, monolithic appearance
• Open-back horizontals and perimeters are available for cost savings
• Shear block fabrication method
• Corners and splayed mullions available
• Offers integrated entrance framing systems
• Silicon compatible glazing materials for long-lasting seals
• 1600 Wall SystemTM2 has been small and large missile impact and cycle tested
• Two color option
• PermanodicTM anodized finishes in seven choices
• Painted finishes in standard and custom choices
Optional Features
• Steel reinforcing available
• Rain screen and backpans
• Optional deep profile and bull-nose covers available
• Deep and heavy-weight mullions available
• Fiberglass pressure plates available
• Veneer system available
• Integrates with concealed GLASSventTM for curtain wall
• Integrates with VersoleilTM SunShade Outrigger System and Horizontal Single
Blade Systems
• Profit$MakerTM plus die sets available
• Hurricane impact resistant framing option: 7-13/16" (198.4)
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-086
Product Applications
• Ideal for low to mid-rise applications where high performance is desired
• It is also the right choice for high span applications
For specific product applications,
Consult your Kawneer representative.
kawneer.com
ADMD020
1
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1600 Wall SystemTM2 Curtain Wall
BLANK PAGE
ADMD020
kawneer.com
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
2
DECEMBER, 2015
EC 97911-086
DECEMBER, 2015
1600 Wall SystemTM2 Curtain Wall
EC 97911-086
3
INDEX
Architects – Most extrusion and window types illustrated in this catalog are standard products for Kawneer. These concepts have been expanded
and modified to afford you design freedom. Some miscellaneous details are non-standard and are intended to demonstrate how the system can be
modified to expand design flexibility. Please contact your Kawneer representative for further assistance.
LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE,
WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE
SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS,
AND ASSUMES NO RESPONSIBILITY THEREFOR.
Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses
(
) are millimeters unless otherwise noted.
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
PICTORIAL VIEW.................................................................................5
1" INFILL DETAILS...............................................................................6
1/4" INFILL DETAILS............................................................................7
ENTRANCE DETAILS.......................................................................8,9
CORNERS...........................................................................................10
SPLAYED MULLION OPTIONS.........................................................11
GLASSventTM FOR CURTAIN WALL/WINDOWS..............................12
BACKPAN AND MISCELLANEOUS DETAILS .................................13
MISCELLANEOUS FRAMING............................................................14
HURRICANE IMPACT RESISTANT DETAILS..............................15,16
ANCHORING.................................................................................17,18
WIND LOAD CHARTS.................................................................. 19-30
DEADLOAD CHARTS.................................................................. 31-33
THERMAL CHARTS..................................................................... 34-42
The following metric (SI ) units are found in these details:
m –meter
cm – centimeter
mm –millimeter
s –second
Pa –pascal
MPa –megapascal
Kawneer reserves the right to change configurations without prior notice when deemed necessary for product
improvement.
kawneer.com
ADMD020
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1600 Wall SystemTM2 Curtain Wall
BLANK PAGE
ADMD020
kawneer.com
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
4
DECEMBER, 2015
EC 97911-086
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DECEMBER, 2015
kawneer.com
1600 Wall SystemTM2 Curtain Wall
EC 97911-086
PICTORIAL VIEW
ADMD020
5
9A
7
3
4
7
5
1A
8
8A
6
6A
8
9
ADMD020
2
3
8A
4
9B
OPTIONAL STEEL
REINFORCING
AS REQUIRED
5
6A
6
kawneer.com
© Kawneer Company, Inc., 2014
1" INFILL DETAILS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1600 Wall SystemTM2 Curtain Wall
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
ELEVATION IS NUMBER KEYED TO DETAILS
2-1/2"
(63.5)
9
9A
9B
5-1/4" (133.6)
2
3-3/4" (95.3)
6
DECEMBER, 2015
EC 97911-086
SCALE 3" = 1'-0"
1
1A
1
6" (152.4)
7 -1/2" (190.5)
2-1/2"
(63.5)
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
ELEVATION IS NUMBER KEYED TO DETAILS
7A
kawneer.com
6
2-1/2"
(63.5)
OPTIONAL STEEL
REINFORCING
AS REQUIRED
5A
ADMD020
2-1/2"
(63.5)
5-1/4" (133.6)
7
7A
7B
3-3/4" (95.3)
DECEMBER, 2015
1600 Wall SystemTM2 Curtain Wall
EC 97911-086
1/4" INFILL DETAILS
SCALE 3" = 1'-0"
1
1A
1
2
3
6
6A
4
1A
5
5A
2
6 -3/4" (171.5)
5-1/4" (133.4)
7
3
6A
4
7B
5
7
1600 Wall SystemTM2 Curtain Wall
8
DECEMBER, 2015
ENTRANCE DETAILS (1" INFILL)
EC 97911-086
SCALE 3" = 1'-0"
3
2
5
4
1
6
TRANSOM BAR
B/H OR O/P
C/H
BUTT HUNG OR
OFFSET PIVOT WITH
SURFACE CLOSER
OR FLOOR CLOSER
B/H OR O/P
ELEVATION IS NUMBER KEYED TO DETAILS
1A
DOOR JAMB
1-7/8"
(47.6)
TYP.
2
BUTT HUNG OR
OFFSET PIVOT
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1
1A
TRANSOM BAR
3
DOOR JAMB
4
CENTER HUNG
TRANSOM BAR
CENTER HUNG
CONCEALED OVERHEAD
OR FLOOR CLOSER
DOOR JAMB
6
BUTT HUNG OR
OFFSET PIVOT
5
TRANSOM BAR
BUTT HUNG OR OFFSET PIVOT
WITH LCN CONCEALED
OVER HEAD CLOSER
OR SURFACE CLOSER
ADMD020
kawneer.com
© Kawneer Company, Inc., 2014
3/4"
(19.0)
TYP..
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
BUTT HUNG OR
OFFSET PIVOT WITH
SAM II CLOSER
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
1-7/8"
(47.6)
TYP.
TYP
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DECEMBER, 2015
2
B/H OR O/P
2
kawneer.com
1600 Wall SystemTM2 Curtain Wall
EC 97911-086
ENTRANCE DETAILS (1/4" INFILL)
SCALE 3" = 1'-0"
1
1A
3
4
1
C/H
TRANSOM BAR
ELEVATION IS NUMBER KEYED TO DETAILS
BUTT HUNG OR
OFFSET PIVOT WITH
SURFACE CLOSER
OR FLOOR CLOSER
DOOR JAMB
BUTT HUNG OR
OFFSET PIVOT
1A
3/4"
(19.0)
TYP..
TRANSOM BAR
BUTT HUNG OR
OFFSET PIVOT WITH
SAM II CLOSER
DOOR JAMB
CENTER HUNG
4
3
TRANSOM BAR
CENTER HUNG
CONCEALED OVERHEAD
OR FLOOR CLOSER
ADMD020
9
90° OUTSIDE CORNER
90° INSIDE CORNER
135° OUTSIDE CORNER
135° INSIDE CORNER
ADMD020
kawneer.com
© Kawneer Company, Inc., 2014
CORNERS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1600 Wall SystemTM2 Curtain Wall
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
10
DECEMBER, 2015
EC 97911-086
SCALE 3" = 1'-0"
NOTE: 1" SYSTEM SHOWN, 1/4" SYSTEM SIMILAR.
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DECEMBER, 2015
0° TO 5°
0° TO 5°
kawneer.com
1600 Wall SystemTM2 Curtain Wall
EC 97911-086
SPLAYED MULLION OPTIONS
SCALE 3" = 1'-0"
5° TO 15°
5° TO 15°
INSIDE SPLAYED MULLIONS
ADMD020
15° TO 25°
OUTSIDE SPLAYED MULLIONS
15° TO 25°
11
HEAD
SILL
JAMB
8225TL THERMAL WINDOWS
NOTE: Other vent types can be accommodated.
Contact your Kawneer representative for other options.
HEAD
SILL
JAMB
ADMD020
kawneer.com
© Kawneer Company, Inc., 2014
GLASSventTM FOR CURTAIN WALL/WINDOWS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1600 Wall SystemTM2 Curtain Wall
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
12
DECEMBER, 2015
EC 97911-086
SCALE 3" = 1'-0"
GLASSventTM FOR CURTAIN WALL
© Kawneer Company, Inc., 2014
6" (152.4)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
kawneer.com
6
7
3
ELEVATION IS NUMBER KEYED TO DETAILS
NOTE: 6" SYSTEM SHOWN, 7-1/2" SYSTEM SIMILAR
1
JAMB MULLION
AT SPANDREL
(With vapor barrier tie-in)
3
THERMALLY BROKEN
DOOR ADAPTOR
FOR INSULCLAD DOORS
AATM 250 THERMAL
ENTRANCE
D.L.O.
2
MULLION LENGTH
1
3/8" (9.5)
2-1/2" (63.5)
3/8" (9.5)
D.L.O.
MULLION LENGTH
CONSTRUCTION JOINT
1/2" (12.7) MAX (ALLOWS +/-1/4" MOVEMENT)
DECEMBER, 2015
1600 Wall SystemTM2 Curtain Wall
EC 97911-086
BACKPAN AND MISCELLANEOUS DETAILS
SCALE 3" = 1'-0"
4
4
5
HEAD TRANSOM AT PARAPET FLASHING
5
EXPANSION JOINT
2
6
2-1/2"
(63.5)
MULLION AT SPANDREL
TYPICAL DEADLOAD ANCHOR
3
7
TRANSOM – SPANDREL OVER VISION
ADMD020
13
14
1600 Wall SystemTM2 Curtain Wall
DECEMBER, 2015
MISCELLANEOUS FRAMING
EC 97911-086
SCALE 3" = 1'-0"
4-3/4"
(120.7)
Architects – Most extrusion and window types illustrated in this catalog are
standard products for Kawneer. These concepts have been expanded
and modified to afford you design freedom. Some miscellaneous details
are non-standard and are intended to demonstrate how the system can
be modified to expand design flexibility. Please contact your Kawneer
representative for further assistance.
2-1/2"
(63.5)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
3"
(76.2)
2-1/2"
(63.5)
1-1/4"
(31.8)
7-1/2"
(190.5)
10-1/2"
(266.7)
4"
(101.6)
2-1/2"
(63.5)
6"
(152.4)
1-3/16"
(30.1)
2"
(50.8)
2-3/4"
(69.7)
4" SIGHT LINE
OPTIONAL COVERS
2-1/2"
(63.5)
VENEER SYSTEM
DOUBLE MULLION
069263
GYPSUM BOARD TRIM
2-1/2"
(63.5)
OPTIONAL
FIBERGLASS
PRESSURE PLATE
STOOL TRIM OPTIONS:
069264 - 2-3/4" (69.9)
069265 - 4-1/2" (114.3)
069266 - 5" (127.0)
069267 - 6-1/8" (155.6)
069268 - 6-3/4" (171.4)
NOTE:
STOOL TRIMS REQUIRE 069271 TRIM CLIP PACKAGE
INTERIOR STOOL TRIM
ADMD020
kawneer.com
© Kawneer Company, Inc., 2014
VARIES
CAPTURED
MULLION (1")
2-1/2"
(63.5)
2-1/2"
(63.5)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
2-1/2"
(63.5)
1-3/4"
(45)
DEEP MULLION
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
2
5
5A
kawneer.com
7
7
2
5
2-1/2"
(63.5)
EC 97911-086
8
ELEVATION IS NUMBER KEYED TO DETAILS
EXPANSION
HORIZONTAL
5A
OPTIONAL STEEL
REINFORCING
AS REQUIRED
ADMD020
2-3/4"
(69.9)
DECEMBER, 2015
1600 Wall SystemTM2 Curtain Wall
HURRICANE IMPACT RESISTANT DETAILS
SCALE 3" = 1'-0"
NOTE: DETAILS SHOWN WITH 1-5/16" INFILL AND ARE GLAZED FOR LARGE MISSLE IMPACT (LMI).
SEE NEXT PAGE FOR OTHER GLAZING OPTIONS.
1
1
3
7-13/16"
(198.5)
6
10
2
9
4
3
6
4
7
15
16
1600 Wall SystemTM2 Curtain Wall
DECEMBER, 2015
EC 97911-086
HURRICANE RESISTANT DETAILS
SCALE 3" = 1'-0"
NOTE: 350 IR DOORS ARE USED WITH IMPACT FRAMING.
DOORS ARE GLAZED WITH 9/16" INFILL.
8
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DOOR JAMB
AT PERIMETER
DOOR JAMB
AT MULLION
1-5/16" INFILL
(LMI)
9
7/8"
(22.2)
TYP..
10
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
TRANSOM BAR
1-5/16" INFILL (LMI)
GLAZING OPTIONS
1-5/16" INFILL (SMI)
SMALL MISSILE
IMPACT
1-5/16" INFILL
SMALL MISSILE (SMI)
OVER
LARGE MISSILE (LMI)
ADMD020
kawneer.com
© Kawneer Company, Inc., 2014
OPTIONAL
10" DEEP SYSTEM
1-5/16" INFILL (LMI)
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DECEMBER, 2015
kawneer.com
1600 Wall SystemTM2 Curtain Wall
EC 97911-086
ANCHORING
Actual project conditions will determine specific anchor design. Details on this page are for reference only.
1" (25.4) MINIMUM
ANCHORING TO FLOOR SLAB
1" (25.4) MINIMUM
ANCHORING TO SUPPORT STEEL
ADMD020
17
ANCHORING TO HORIZONTAL
STRUCTURAL STEEL
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1600 Wall SystemTM2 Curtain Wall
ANCHORING
ANCHORING TO VERTICAL
STRUCTURAL STEEL
ADMD020
kawneer.com
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
18
DECEMBER, 2015
EC 97911-086
Actual project conditions will determine specific anchor design. Details on this page are for reference only.
DECEMBER, 2015
1600 Wall SystemTM2 Curtain Wall
EC 97911-086
19
WIND LOAD/DEADLOAD CHARTS
Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4"
above 13'-6". These curves are for mullions WITH HORIZONTALS and are based on engineering calculations for stress
and deflection. Allowable wind load stress for ALUMINUM 15,152 psi (104MPa), STEEL 30,000 psi (207MPa.). Charted
curves, in all cases are for the limiting value. Wind load charts contained herein are based upon nominal wind load
utilized in allowable stress design. To convert ultimate wind loads to nominal loads, multiply ultimate wind loads by a
factor of 0.6 per ASCE/SEI 7. A 4/3 increase in allowable stress has not been used to develop these curves. For special
situations not covered by these curves, contact your Kawneer representative for additional information.
DEADLOAD CHARTS
Horizontal or deadload limitations are based upon 1/8" (3.2), maximum allowable deflection at the center of an
intermediate horizontal member. The accompanying charts are calculated for 1" (25.4) thick insulating glass or 1/4" (6.4)
thick glass supported on two setting blocks placed at the loading points shown.
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
WIND LOAD CHARTS
kawneer.com
ADMD020
1600 Wall SystemTM2 Curtain Wall
20
DECEMBER, 2015
WIND LOAD CHARTS (S.S.G.)
SINGLE SPAN
1
1.5
TWIN SPAN
A = 20 PSF (960)
B = 30 PSF (1440)
C = 40 PSF (1920)
D = 50 PSF (2400)
E = 60 PSF (2880)
METERS
.5
2
23
EC 97911-086
7
METERS
.5
1
1.5
2
30
9
22
6.5
20
28
6
19
5.5
4
13
12
3.5
MULLION HEIGHT
EQUAL
EQUAL
4.5
14
3-3/4" (95.3)
15
MULLION HEIGHT
5
16
11
162025
10
B
0
1
2
3
I = 2.860(119.04 x 10 )
S = 1.482(24.28 x 103)
7
C
22
6.5
21
D
20
6
E
19
5.5
18
5
16
2.5
15
4.5
14
D
E
6
23
2
4
13
4
5
6
7
12
8
0
MULLION CENTERS IN FEET
1
2
3
SINGLE SPAN
1
5
6
7
8
TWIN SPAN
METERS
METERS
.5
4
MULLION CENTERS IN FEET
1.5
.5
2
23
1
1.5
2
30
7
9
29
6.5
21
20
28
6
A
8
26
19
5.5
4
13
12
3.5
11
162026
A
10
3
9
C
8
MULLION HEIGHT
EQUAL
EQUAL
4.5
14
3-3/4" (95.3)
15
METERS
5
MULLION HEIGHT
17
16
B
I = 3.660(152.34 x 104)
S = 1.840(30.15 x 103)
2.5
7.5
24
C
23
7
22
D
E
21
6.5
20
6
19
5.5
18
17
5
16
15
E D
7
B
25
MULLION HEIGHT IN FEET
18
MULLION HEIGHT IN FEET
8.5
27
METERS
22
4.5
14
2
6
5
4
13
0
1
2
3
4
5
6
7
12
8
0
1
2
3
4
5
6
7
8
MULLION CENTERS IN FEET
MULLION CENTERS IN FEET
ADMD020
kawneer.com
© Kawneer Company, Inc., 2014
7
7.5
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
C
8
A
B
24
17
4
3
A
9
MULLION HEIGHT IN FEET
25
17
METERS
MULLION HEIGHT IN FEET
8
26
18
5
8.5
27
METERS
21
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
29
1600 Wall SystemTM2 Curtain Wall
DECEMBER, 2015
EC 97911-086
21
WIND LOAD CHARTS (S.S.G.)
SINGLE SPAN
METERS
.5
1
1.5
2
23
TWIN SPAN
A = 20 PSF (960)
B = 30 PSF (1440)
C = 40 PSF (1920)
D = 50 PSF (2400)
E = 60 PSF (2880)
7
METERS
1
.5
1.5
2
30
9
A
28
27
6
19
8
26
5.5
4.5
14
4
13
A
12
3.5
11
C
B
10
162027
7.5
E
23
7
22
6.5
21
20
6
19
5.5
18
5
16
I = 6.424(267.38 x 104)
S = 2.385(39.08 x 103)
2.5
8
D
24
17
3
E D
9
5-1/4" (133.4)
15
METERS
5
16
MULLION HEIGHT
17
MULLION HEIGHT IN FEET
25
MULLION HEIGHT
EQUAL
EQUAL
18
15
7
4.5
14
2
6
4
13
0
1
2
3
4
5
6
7
12
8
0
1
2
4
5
6
7
8
MULLION CENTERS IN FEET
SINGLE SPAN
TWIN SPAN
METERS
1
METERS
1.5
2
.5
23
1
1.5
2
30
7
22
6.5
20
28
6
26
5.5
A
13
4
B
12
C
11
10
3.5
162028
2.5
8
8
E
7.5
24
23
7
22
6.5
21
20
6
19
5.5
18
17
3
E D
9
D C
METERS
4.5
14
5-1/4" (133.4)
15
METERS
5
16
MULLION HEIGHT
17
MULLION HEIGHT IN FEET
25
MULLION HEIGHT
EQUAL
EQUAL
18
8.5
B
27
19
9
A
29
21
MULLION HEIGHT IN FEET
3
MULLION CENTERS IN FEET
.5
© Kawneer Company, Inc., 2014
8.5
B
C
METERS
6.5
20
5
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
29
21
MULLION HEIGHT IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
22
I = 8.088(336.64 x 104)
S = 2.930(48.01 x 103)
7
5
16
15
4.5
14
2
6
5
4
13
0
1
2
3
4
5
6
7
12
8
MULLION CENTERS IN FEET
kawneer.com
0
1
2
3
4
5
6
7
MULLION CENTERS IN FEET
ADMD020
8
WIND LOAD CHARTS (S.S.G.)
0
1
1
15
14
2
3
1.5
18
17
16
4
5
2
8.5
26
8
25
24
7.5
23
7
21
22
6.5
20
19
A
6
6
B
5.5
C
D
5
E
4.5
13
4
MULLION CENTERS IN FEET
7
8
I = 31.174(1297.56 x 104)
S = 7.452(122.12 x 103)
162076
ADMD020
kawneer.com
© Kawneer Company, Inc., 2014
12
1600 Wall SystemTM2 Curtain Wall
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
METERS
8-1/4" (209.6)
.5
MULLION HEIGHT
28
METERS
SINGLE SPAN
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
MULLION HEIGHT IN FEET
22
DECEMBER, 2015
EC 97911-086
A = 20 PSF (960)
B = 30 PSF (1440)
C = 40 PSF (1920)
D = 50 PSF (2400)
E = 60 PSF (2880)
27
1600 Wall SystemTM2 Curtain Wall
DECEMBER, 2015
EC 97911-086
WIND LOAD CHARTS (1" INFILL)
SINGLE SPAN
METERS
.5
1
1.5
SINGLE SPAN
A = 20 PSF (960)
B = 30 PSF (1440)
C = 40 PSF (1920)
D = 50 PSF (2400)
E = 60 PSF (2880)
162028 W/162300
2
30
9
162028 W/162301
METERS
.5
28
2
9
28
8.5
27
8.5
27
8
25
25
MULLION HEIGHT IN FEET
7.5
MULLION HEIGHT
24
23
6.5
21
20
METERS
7
22
6
19
A
5.5
18
17
B
16
5
C
15
4.5
E
14
D
13
0
1
2
3
162028
with 162300
162028
with 162301
Ia = 8.088(336.64 x 104)
Sa = 2.930(48.01 x 103)
Is = 3.805(158.37 x 104)
Ss = 1.669(27.35 x 103)
Ia = 8.088(336.64 x 104)
Sa = 2.930(48.01 x 103)
Is = 5.684(236.59 x 104)
Ss = 2.493(40.85 x 103)
5
6
7
7.5
24
23
7
22
6.5
21
A
20
18
5
16
E
15
4
13
12
8
0
1
2
3
4
5
6
7
8
MULLION CENTERS IN FEET
SINGLE SPAN
162028 W/162301/302/303
METERS
1.5
4.5
D
14
162028 W/162301/302
1
5.5
C
SINGLE SPAN
.5
6
B
19
17
4
4
8
26
METERS
26
MULLION HEIGHT IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1.5
29
MULLION CENTERS IN FEET
METERS
2
.5
30
1
1.5
2
30
9
9
29
29
28
28
8.5
8
25
MULLION HEIGHT IN FEET
7.5
7
22
6.5
21
A
20
6
B
19
5-1/4" (133.4)
23
MULLION HEIGHT
24
METERS
MULLION HEIGHT IN FEET
25
5.5
18
C
17
5
16
E D
15
162028
with 162301/302
162028
with 162301/302/303
Ia = 8.088(336.64 x 10 )
Sa = 2.930(48.01 x 103)
Is = 7.893(328.53 x 104)
Ss = 3.462(56.73 x 103)
Ia = 8,088(336,64 x 10 )
Sa = 2,930(48,01 x 103)
Is = 9,347(389,05 x 104)
Ss = 4,100(67,19 x 103)
4
4.5
14
4
4
13
0
1
2
3
4
5
6
7
7.5
24
23
7
22
6.5
21
A
20
B
19
6
C
18
5.5
17
E D
16
5
15
4.5
14
4
13
12
8
MULLION CENTERS IN FEET
kawneer.com
8
26
METERS
26
12
8.5
27
27
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
1
30
29
12
23
0
1
2
3
4
5
6
7
MULLION CENTERS IN FEET
ADMD020
8
1600 Wall SystemTM2 Curtain Wall
24
DECEMBER, 2015
WIND LOAD CHARTS (1" INFILL)
SINGLE SPAN
1
1.5
TWIN SPAN
A = 20 PSF (960)
B = 30 PSF (1440)
C = 40 PSF (1920)
D = 50 PSF (2400)
E = 60 PSF (2880)
METERS
.5
2
7
23
EC 97911-086
METERS
.5
1
1.5
2
30
9
22
A
26
5.5
25
4
13
A
12
B
11
3.5
MULLION HEIGHT
EQUAL
EQUAL
4.5
14
6" (152.4)
15
METERS
5
16
MULLION HEIGHT
17
MULLION HEIGHT IN FEET
18
C
10
E
8
22
20
13
12
4
5
6
7
6
E
18
5
3
D
19
5.5
5
4.5
14
2
2
6.5
21
6
1
7
C
15
I = 5.035(209.57 x 104)
S = 1.993(32.66 x 103)
0
B
23
16
162001
2.5
7
7.5
24
17
3
D
9
8
8
4
0
1
2
3
4
5
6
7
8
MULLION CENTERS IN FEET
MULLION CENTERS IN FEET
SINGLE SPAN
TWIN SPAN
METERS
.5
1
METERS
1.5
.5
2
7
23
1
1.5
2
30
9
22
29
6.5
20
6
8
26
5.5
4
13
B
12
3.5
11
MULLION HEIGHT
EQUAL
EQUAL
A
6" (152.4)
4.5
14
MULLION HEIGHT
15
METERS
5
16
C
10
C
23
7
22
6.5
21
D
20
6
19
E
18
5.5
5
16
E
8
7.5
24
17
3
D
9
B
25
17
MULLION HEIGHT IN FEET
18
MULLION HEIGHT IN FEET
8.5
27
19
2.5
7
2
162002
15
I = 6.779(282.16 x 104)
S = 2.652(43.46 x 103)
14
4.5
4
13
6
5
A
28
0
1
2
3
4
5
6
7
METERS
21
12
8
MULLION CENTERS IN FEET
0
1
2
3
4
5
6
7
8
MULLION CENTERS IN FEET
ADMD020
kawneer.com
© Kawneer Company, Inc., 2014
6
19
MULLION HEIGHT IN FEET
8.5
27
METERS
20
28
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
6.5
21
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
29
1600 Wall SystemTM2 Curtain Wall
DECEMBER, 2015
EC 97911-086
25
WIND LOAD CHARTS (1" INFILL)
SINGLE SPAN
METERS
.5
1
1.5
2
7
23
TWIN SPAN
A = 20 PSF (960)
B = 30 PSF (1440)
C = 40 PSF (1920)
D = 50 PSF (2400)
E = 60 PSF (2880)
METERS
.5
1
1.5
2
30
9
29
6.5
20
28
6
B
26
5.5
25
4.5
B
13
4
C
12
3.5
D
11
E
10
MULLION HEIGHT
EQUAL
EQUAL
A
14
7-1/2" (190.5)
15
METERS
5
16
MULLION HEIGHT
17
MULLION HEIGHT IN FEET
18
MULLION HEIGHT IN FEET
8.5
27
19
3
7
7.5
C
24
7
23
D
22
6.5
21
E
20
6
19
5.5
18
5
16
162003
2.5
8
8
17
9
15
I = 10.135(421.85 x 104)
S = 3.027(49.60 x 103)
4.5
14
2
4
13
6
5
A
0
1
2
3
4
5
6
7
12
8
0
1
2
3
4
5
6
7
MULLION CENTERS IN FEET
MULLION CENTERS IN FEET
SINGLE SPAN
TWIN SPAN
METERS
1
METERS
21
.5
8
METERS
1.5
.5
2
7
23
1
1.5
2
30
9
29
6.5
21
20
28
6
8
26
5.5
B
13
4
C
12
D
3.5
MULLION HEIGHT
EQUAL
EQUAL
4.5
7-1/2" (190.5)
A
14
MULLION HEIGHT
15
METERS
5
16
11
E
10
2.5
8
7
7.5
E
24
7
23
22
6.5
21
20
6
19
5.5
18
17
3
9
D
25
17
MULLION HEIGHT IN FEET
18
MULLION HEIGHT IN FEET
8.5
C
27
19
162004
I = 12.736(530.11 x 104)
S = 3.791(62.12 x 103)
2
5
16
15
4.5
14
4
13
6
5
B
0
1
2
3
4
5
6
7
12
8
MULLION CENTERS IN FEET
kawneer.com
0
1
2
3
4
5
6
7
MULLION CENTERS IN FEET
ADMD020
8
METERS
22
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
22
WIND LOAD CHARTS (1" INFILL)
0
1
1
2
3
1.5
27
26
8
25
24
7.5
23
22
A
7
21
6.5
20
19
B
18
17
D
16
E
4
5
6
6
C
5.5
5
15
14
4.5
13
4
7
MULLION CENTERS IN FEET
8
I = 42.441(1766.52 x 104)
S = 8.816(144.47 x 103)
162064
ADMD020
kawneer.com
© Kawneer Company, Inc., 2014
12
1600 Wall SystemTM2 Curtain Wall
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
METERS
10-1/2" (266.7)
28
MULLION HEIGHT
.5
METERS
SINGLE SPAN
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
MULLION HEIGHT IN FEET
26
DECEMBER, 2015
EC 97911-086
A = 20 PSF (960)
B = 30 PSF (1440)
C = 40 PSF (1920)
D = 50 PSF (2400)
E = 60 PSF (2880)
2
8.5
1600 Wall SystemTM2 Curtain Wall
DECEMBER, 2015
EC 97911-086
WIND LOAD CHARTS (1" INFILL)
SINGLE SPAN
METERS
.5
1
1.5
SINGLE SPAN
A = 20 PSF (960)
B = 30 PSF (1440)
C = 40 PSF (1920)
D = 50 PSF (2400)
E = 60 PSF (2880)
162004 W/162300
2
30
9
162004 W/162301
METERS
.5
2
9
28
28
8.5
8.5
27
8
25
25
MULLION HEIGHT
7.5
24
22
6.5
21
A
20
6
B
19
18
METERS
7
23
5.5
C
17
5
16
D
15
4.5
E
14
4
13
0
1
2
3
4
5
6
7
8
26
MULLION HEIGHT IN FEET
26
162004
with 162300
162004
with 162301
Ia = 12.736(530.11 x 104)
Sa = 3.791(62.12 x 103)
Is = 3.805(158.37 x 104)
Ss = 1.669(27.35 x 103)
Ia = 12.736(530.11 x 104)
Sa = 3.791(62.12 x 103)
Is = 5.684(236.59 x 104)
Ss = 2.493(40.85 x 103)
7.5
24
7
23
22
A
21
20
6
19
C
17
D
16
15
4.5
14
4
13
12
8
0
1
2
3
4
5
6
7
8
MULLION CENTERS IN FEET
SINGLE SPAN
162004 W/162301/302/303
METERS
1.5
5
E
SINGLE SPAN
1
5.5
18
162004 W/162301/302
.5
6.5
B
METERS
.5
2
1
1.5
2
30
30
9
9
29
29
28
28
8.5
7
A
22
6.5
21
B
20
6
19
C
18
5.5
17
D
16
5
E
15
4.5
14
4
13
0
1
2
3
4
5
6
7
162004
with 162301/302
162004
with 162301/302/303
Ia = 12.736(530.11 x 104)
Sa = 3.791(62.12 x 103)
Is = 7.893(328.53 x 104)
Ss = 3.462(56.73 x 103)
Ia = 12.736(530.11 x 104)
Sa = 3.791(62.12 x 103)
Is = 9.347(389.05 x 104)
Ss = 4.100(67.19 x 103)
8
7.5
24
A
7
23
22
B
21
6.5
20
6
C
19
5.5
18
D
17
5
16
E
15
4.5
14
4
13
12
MULLION CENTERS IN FEET
kawneer.com
7-1/2" (190.5)
MULLION HEIGHT
23
MULLION HEIGHT IN FEET
25
7.5
24
METERS
MULLION HEIGHT IN FEET
25
8
26
0
1
2
3
4
5
6
7
MULLION CENTERS IN FEET
ADMD020
8
METERS
8
26
© Kawneer Company, Inc., 2014
8.5
27
27
12
METERS
27
MULLION HEIGHT IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1.5
29
MULLION CENTERS IN FEET
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
1
30
29
12
27
1600 Wall SystemTM2 Curtain Wall
28
DECEMBER, 2015
WIND LOAD CHARTS (1/4" INFILL)
SINGLE SPAN
METERS
.5
1
1.5
TWIN SPAN
A = 20 PSF (960)
B = 30 PSF (1440)
C = 40 PSF (1920)
D = 50 PSF (2400)
E = 60 PSF (2880)
2
7
23
EC 97911-086
1.5
2
9
8.5
27
A
26
25
4
13
12
3.5
11
MULLION HEIGHT
EQUAL
EQUAL
4.5
14
5-1/4" (133.4)
15
METERS
5
16
MULLION HEIGHT
17
A
10
C
D
8
E
7
7.5
24
7
23
22
B
21
6
19
C
18
5
E
15
I = 3.662(152.42 x 104)
S = 1.662(27.24 x 103)
5.5
D
16
162013
2.5
6.5
20
17
3
B
9
MULLION HEIGHT IN FEET
5.5
18
8
4.5
14
2
4
13
6
0
1
2
3
4
5
6
7
12
8
0
1
2
3
4
5
6
7
MULLION CENTERS IN FEET
MULLION CENTERS IN FEET
SINGLE SPAN
TWIN SPAN
METERS
.5
1
8
METERS
1.5
2
.5
7
23
1
1.5
2
30
9
22
29
6.5
20
28
19
A
26
5.5
4
13
12
A
11
3.5
B
10
D
8
2.5
E
7
162014
I = 4.5071(87.60 x 104)
S = 1.968(32.25 x 103)
2
20
4
5
6
7
6
D
19
E
18
5.5
8
MULLION CENTERS IN FEET
5
16
15
4.5
14
12
3
6.5
21
13
2
C
22
5
1
7
23
6
0
7.5
24
17
3
C
9
MULLION HEIGHT IN FEET
4.5
14
5-1/4" (133.4)
15
METERS
5
16
MULLION HEIGHT
17
8
B
25
MULLION HEIGHT
EQUAL
EQUAL
18
MULLION HEIGHT IN FEET
8.5
27
6
METERS
21
4
0
1
2
3
4
5
6
7
8
MULLION CENTERS IN FEET
ADMD020
kawneer.com
© Kawneer Company, Inc., 2014
6
19
METERS
20
28
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
6.5
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
29
21
MULLION HEIGHT IN FEET
1
30
22
5
METERS
.5
1600 Wall SystemTM2 Curtain Wall
DECEMBER, 2015
EC 97911-086
29
WIND LOAD CHARTS (1/4" INFILL)
SINGLE SPAN
METERS
.5
1
1.5
2
7
23
TWIN SPAN
A = 20 PSF (960)
B = 30 PSF (1440)
C = 40 PSF (1920)
D = 50 PSF (2400)
E = 60 PSF (2880)
METERS
.5
1
1.5
2
30
9
29
6.5
20
6
8
26
5.5
13
4
B
12
C
11
3.5
D
10
MULLION HEIGHT IN FEET
4.5
A
14
6-3/4" (171.5)
15
METERS
5
16
MULLION HEIGHT
EQUAL
EQUAL
25
17
MULLION HEIGHT
18
7
7
22
C
21
6.5
20
6
19
D
18
5.5
E
5
16
162015
2.5
8
7.5
23
17
3
E
9
B
24
I = 7.915(329.45 x 104)
S = 2.635(43.18 x 103)
15
4.5
14
2
6
4
13
0
1
2
3
4
5
6
7
12
8
0
1
2
3
SINGLE SPAN
1
5
6
7
8
TWIN SPAN
METERS
.5
4
MULLION CENTERS IN FEET
MULLION CENTERS IN FEET
METERS
1.5
2
.5
7
23
1
1.5
2
30
9
29
6.5
21
20
8.5
B
27
6
19
8
26
5.5
B
13
4
C
12
3.5
11
D
10
9
2.5
8
7
2
23
4
5
6
7
162016
I = 9.594(399.33 x 104)
S = 3.163(51.83 x 103)
8
MULLION CENTERS IN FEET
kawneer.com
6
19
5.5
18
5
16
15
4.5
14
12
3
E
20
13
2
6.5
21
5
1
7
D
22
6
0
7.5
24
17
3
E
MULLION HEIGHT IN FEET
4.5
A
14
MULLION HEIGHT
EQUAL
EQUAL
15
METERS
5
6-3/4" (171.5)
17
16
C
25
MULLION HEIGHT
18
MULLION HEIGHT IN FEET
A
28
4
0
1
2
3
4
5
6
7
MULLION CENTERS IN FEET
ADMD020
8
METERS
22
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
8.5
27
19
5
A
28
METERS
21
MULLION HEIGHT IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
22
1600 Wall SystemTM2 Curtain Wall
30
DECEMBER, 2015
WIND LOAD CHARTS (1/4" INFILL)
SINGLE SPAN
.5
1
1.5
SINGLE SPAN
A = 20 PSF (960)
B = 30 PSF (1440)
C = 40 PSF (1920)
D = 50 PSF (2400)
E = 60 PSF (2880)
162016 W/162300
METERS
EC 97911-086
2
30
162016 W/162301
METERS
.5
28
8.5
25
25
22
A
6.5
20
6
B
18
17
5.5
C
5
16
15
4.5
D
14
E
13
0
1
2
3
4
4
5
6
7
162016
with 162300
162016
with 162301
Ia = 9.594(399.33 x 104)
Sa = 3.163(51.83 x 103)
Is = 3.805(158.37 x 104)
Ss = 1.669(27.35 x 103)
Ia = 9.594(399.33 x 104)
Sa = 3.163(51.83 x 103)
Is = 5.684(236.59 x 104)
Ss = 2.493(40.85 x 103)
7
23
22
6.5
21
A
20
B
18
17
5
16
D
15
4.5
E
14
4
13
12
8
0
1
2
3
4
5
6
7
8
MULLION CENTERS IN FEET
SINGLE SPAN
SINGLE SPAN
162016 W/162301/302
162016 W/162301/302/303
METERS
METERS
1
5.5
C
MULLION CENTERS IN FEET
.5
6
19
1.5
2
.5
30
1
1.5
2
30
9
9
29
29
28
28
8.5
27
8.5
27
22
6.5
21
20
B
6
MULLION HEIGHT IN FEET
A
METERS
7
23
19
18
5.5
C
17
16
15
14
D
5
E
4.5
4
13
0
1
2
3
4
5
6
7
A
25
MULLION HEIGHT
7.5
24
6-3/4" (171.5)
25
8
26
162016
with 162301/302
162016
with 162301/302/303
Ia = 9.594(399.33 x 104)
Sa = 3.163(51.83 x 103)
Is = 7.893(328.53 x 104)
Ss = 3.462(56.73 x 103)
Ia = 9.594(399.33 x 104)
Sa = 3.163(51.83 x 103)
Is = 9.347(389.05 x 104)
Ss = 4.100(67.19 x 103)
7
23
B
22
6.5
21
C
20
6
19
D
5.5
18
17
E
5
16
15
4.5
14
4
13
12
8
7.5
24
METERS
8
26
0
1
2
3
4
5
6
7
8
MULLION CENTERS IN FEET
MULLION CENTERS IN FEET
ADMD020
kawneer.com
© Kawneer Company, Inc., 2014
19
7.5
24
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
21
METERS
7
MULLION HEIGHT IN FEET
MULLION HEIGHT
7.5
24
23
8
26
METERS
8
26
MULLION HEIGHT IN FEET
8.5
27
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
28
MULLION HEIGHT IN FEET
2
29
27
12
1.5
9
29
12
1
30
9
GLASS HEIGHT IN FEET
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
0
kawneer.com
0
0
1
13
1
2
.5
2
3
3
4
1
4
5
8
7
5
A - 1/4" GLASS (1/4 POINT LOADING)
B - 1" GLASS (1/4 POINT LOADING)
162001
METERS
2
6
5
6
1.5
6
13
12
11
10
3
9
8
2.5
7
A
7
9
7
2
B
1.5
4
3
1
2
0.5
1
8
10
A
5
3
2
0
2
12
11
3
2.5
B
2
6
4
1.5
1
1
0.5
8
0
SPAN IN FEET
ADMD020
.5
0
0
1
13
1
1
SPAN IN FEET
2
METERS
.5
2
3
7-1/2" (190.5)
3
1.5
3.5
10
8
7
6
A
5
4
162003
1
4
5
SPAN IN FEET
5
6
1.5
7
6
7
9
7
2
B
3
2
3.5
10
A
8
B
6
2
5
4
1.5
3
1
2
1
0.5
8
METERS
1.5
GLASS HEIGHT IN FEET
EC 97911-086
METERS
0
1
GLASS HEIGHT IN FEET
13
.5
METERS
6" (152.4)
METERS
GLASS HEIGHT IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DECEMBER, 2015
1600 Wall SystemTM2 Curtain Wall
31
DEADLOAD CHARTS (TUBULAR)
6" (152.4)
162002
METERS
2
12
11
3.5
9
3
2.5
4
1.5
1
1
0.5
SPAN IN FEET
8
7-1/2" (190.5)
162004
METERS
2
12
11
3.5
3
2.5
GLASS HEIGHT IN FEET
0
0
1
13
1
2
.5
2
3
3
4
1
4
5
5
162014
METERS
2
6
1.5
9
8
6
13
12
11
A
3
9
8
2.5
7
6
2
5
1.5
4
3
1
2
0.5
1
7
7
8
10
A
7
5
3
2
0
2
12
11
3
2.5
2
6
1.5
4
1
0.5
1
8
0
SPAN IN FEET
ADMD020
.5
METERS
0
0
1
13
1
1
SPAN IN FEET
2
6-3/4" (171.5)
METERS
.5
2
3
162015
3
1.5
4
1
4
5
5
2
3.5
12
11
3.5
10
A
9
6
1.5
9
6
3
8
2.5
7
6
2
5
1.5
4
3
1
2
0.5
7
162016
METERS
2
3.5
12
11
3.5
10
A
7
3
8
2.5
7
6
2
5
4
1.5
3
1
2
1
0.5
SPAN IN FEET
8
kawneer.com
© Kawneer Company, Inc., 2014
162013
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
5-1/4" (133.4)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
DEADLOAD CHARTS (TUBULAR)
METERS
10
GLASS HEIGHT IN FEET
1600 Wall SystemTM2 Curtain Wall
METERS
0
1.5
GLASS HEIGHT IN FEET
0
1
METERS
13
.5
METERS
GLASS HEIGHT IN FEET
32
DECEMBER, 2015
EC 97911-086
A - 1/4" GLASS (1/4 POINT LOADING)
5-1/4" (133.4)
1
SPAN IN FEET
8
6-3/4" (171.5)
1600 Wall SystemTM2 Curtain Wall
DECEMBER, 2015
EC 97911-086
DEADLOAD CHARTS (OPEN BACK)
A - 1" GLASS (1/8 POINT LOADING)
B - 1" GLASS (1/4 POINT LOADING)
162095
162091
(DOTTED)
METERS
1
.5
2
1.5
10
3
A
8
2.5
7
2
6
B
5
METERS
9
1.5
4
1
3
2
2.5
8
7
B
6
2
5
1.5
4
1
3
2
0.5
1
0
1
2
3
4
5
6
7
1
2
3
4
5
6
7
1
8
162097
5
1.5
4
1
3
2
0.5
1
2.5
B
7
2
6
5
1.5
4
1
3
2
0.5
8
A
10
3
9
8
3.5
11
A
3
9
2.5
8
7
B
6
2
5
1.5
4
1
3
2
0.5
1
0
7
2
12
3.5
1
0
1.5
13
GLASS HEIGHT IN FEET
2
1
.5
METERS
B
GLASS HEIGHT IN FEET
2.5
8
SPAN IN FEET
7
162093
(DOTTED)
2
10
3
9
6
6
METERS
1.5
11
METERS
GLASS HEIGHT IN FEET
10
5
5
6-3/4" (171.5)
12
A
6
4
A - 1/4" GLASS (1/8 POINT LOADING)
B - 1/4" GLASS (1/4 POINT LOADING)
METERS
.5
3.5
7
3
162095
162091
(DOTTED)
2
11
kawneer.com
2
162078 REINF.
12
4
1
SPAN IN FEET
13
3
0.5
7-1/2" (190.5)
13
2
1
0
A - 1" GLASS (1/8 POINT LOADING)
B - 1" GLASS (1/4 POINT LOADING)
METERS
1
1.5
4
8
162094
162090
(DOTTED)
0
5
SPAN IN FEET
1.5
2
B
6
0
0
162077 REINF.
1
7
1
6" (152.4)
.5
2.5
8
2
0.5
0
8
3
A
9
3
1
A - 1" GLASS (1/8 POINT LOADING)
B - 1" GLASS (1/4 POINT LOADING)
© Kawneer Company, Inc., 2014
10
3
A
9
3.5
11
GLASS HEIGHT IN FEET
10
GLASS HEIGHT IN FEET
11
2
12
3.5
11
METERS
3.5
1.5
13
12
12
1
.5
2
13
SPAN IN FEET
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
METERS
METERS
1.5
13
0
162096
162092
(DOTTED)
0
0
1
2
3
4
5
SPAN IN FEET
ADMD020
6
7
8
0
1
2
3
4
5
SPAN IN FEET
6
7
8
METERS
1
5-1/4" (133.4)
7-1/2" (190.5)
162094
162090
(DOTTED)
GLASS HEIGHT IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
6" (152.4)
A - 1/4" GLASS (1/8 POINT LOADING)
B - 1/4" GLASS (1/4 POINT LOADING)
METERS
A - 1" GLASS (1/8 POINT LOADING)
B - 1" GLASS (1/4 POINT LOADING)
.5
33
1600 Wall SystemTM2 Curtain Wall
34
DECEMBER, 2015
THERMAL CHARTS
EC 97911-086
Generic Project Specific U-factor Example Calculation
(Percent of Glass will vary on specific products depending on sitelines)
(Based on single bay of Curtain Wall/Window Wall)
VISION
6'-0"
D.L.O.
SPANDREL
9'-0"
D.L.O.
VISION
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
5'-0"
D.L.O.
Vision Area
Example Glass U-factor
= 0.48 Btu/(ft2 · h · °F)
Vision Area
= 5(9 + 8 + 4) = 105.0 ft2
Total Area (Vision)
= 5' 2-1/2" (9' 3-3/4" + 8' 2-1/2" + 4' 2-1/2") = 113.2 ft2
Percentage of Vision Glass
= (Vision Area ÷ Total Area)100
= (105.0 ÷ 113.2)100 = 93%
Spandrel Area
Example Spandrel R-value
= 15 (ft2 · h · °F)/Btu
Spandrel Area
= 5(6 + 3) = 45.0 ft2
Total Area (Spandrel)
= 5' 2-1/2" (6' 2-1/2" + 3' 3-3/4") = 49.6 ft2
Percent of Spandrel
= (Spandrel Area ÷ Total Area)100
= (49.0 ÷ 49.6)100 = 91%
ADMD020
kawneer.com
© Kawneer Company, Inc., 2014
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
VISION
2-1/2" Typ.
SPANDREL
31'-3"
8'-0"
D.L.O.
4'-0"
3'-0"
D.L.O. D.L.O.
2-1/2" Typ.
1600 Wall SystemTM2 Curtain Wall
DECEMBER, 2015
EC 97911-086
35
THERMAL CHARTS
Vision Area Chart
System U-factor vs Percent of Vision Area
0.80
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
T
COG
U-factor
0.53
0.50
0.40
0.30
)
0.48
0.46
0.44
0.42
0.40
0.38
0.36
0.34
0.32
0.30
0.28
0.26
0.24
0.22
0.20
0.60
Btu
h·ft 2·°F
System U-factor
O
E IGN
PL S
M E
A D
EX FOR
(N
0.70
93%
0.20
95
85
90
75
80
70
Vision Area / Total Area (%)
Based on a single curtain wall bay of 93% vision glass and center
of glass U-factor of 0.48, System U-factor is equal to 0.53 Btu/(h·ft 2·°F)
System U-factor vs Percent of Spandrel Area
Spandrel
R-value
E IGN
PL S
M E
A D
EX FOR
O
0.50
T
3.00
4.00
© Kawneer Company, Inc., 2014
5.00
0.21
0.20
0.10
91%
95
0.30
)
11.00
15.00
19.00
30.00
0.40
Btu
h·ft 2·°F
System U-factor
2.00
0.60
(N
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Spandrel Area Chart
90
85
80
75
70
Spandrel Area / Total Area (%)
Based on a single curtain wall bay of 91% spandrel and center of
spandrel R-value of 15, system U-factor is equal to 0.21 Btu/(h·ft 2·°F)
kawneer.com
ADMD020
1600 Wall SystemTM2 Curtain Wall
DECEMBER, 2015
THERMAL CHARTS
EC 97911-086
Note:
Values in parentheses are metric.
COG=Center of Glass.
Charts are generated per AAMA 507.
System U-Factor for Vision Glass
0.90
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
(5.00)
0.85
0.80
(4.50)
0.75
0.70
(4.00)
0.60
0.50
0.45
(3.00)
2
(2.73)
(2.61)
(2.50)
(2.39)
(2.27)
(2.16)
(2.05)
(1.93)
(1.82)
(1.71)
(1.59)
(1.48)
(1.37)
(1.25)
(1.14)
Btu
h·ft 2·°F
0.55
0.48
0.46
0.44
0.42
0.40
0.38
0.36
0.34
0.32
0.30
0.28
0.26
0.24
0.22
0.20
(3.50)
( m W·°C )
COG
U-factor
(2.50)
0.40
0.35
System U-factor
0.65
(2.00)
0.30
(1.50)
0.25
0.20
95
90
85
80
75
70
System U-Factors for Spandrel Glass
0.70
(4.00)
0.65
0.60
(3.50)
0.55
2.00 (0.35)
0.40
0.35
3.00 (0.53)
0.30
4.00 (0.70)
0.25
5.00 (0.88)
(2.50)
2
0.45
( m W·°C )
Spandrel
R-Value
System U-factor
(3.00)
0.50
(2.00)
(1.50)
0.20
(2.00)
0.15
11.00 (1.94)
15.00 (2.64)
19.00 (3.34)
30.00 (5.28)
0.10
(1.50)
0.05
95
90
85
80
75
70
Spandrel Area / Total Area (%)
ADMD020
kawneer.com
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Vision Area / Total Area (%)
Btu
h·ft 2·°F
36
System VT
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System SHGC
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DECEMBER, 2015
kawneer.com
1600 Wall SystemTM2 Curtain Wall
EC 97911-086
THERMAL CHARTS
COG
SHGC
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
Vision Area / Total Area (%)
Charts are generated per AAMA 507.
COG
VT
System Visible Transmittance (VT) vs Percent of Vision Area
Vision Ares / Total Area (%)
Charts are generated per AAMA 507.
ADMD020
37
1600 Wall SystemTM2 Curtain Wall
DECEMBER, 2015
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
0.48
0.56
0.46
0.54
0.44
0.53
0.42
0.51
0.40
0.49
0.38
0.48
0.36
0.46
0.34
0.44
0.32
0.42
0.30
0.41
0.28
0.39
0.26
0.37
0.24
0.36
0.22
0.34
0.20
0.32
NOTE:For glass values that are not listed, linear
interpolation is permitted.
1.
2.
3.
4.
SHGC Matrix 2
U-Factors are determined in accordance with NFRC 100.
SHGC and VT values are determined in accordance with
NFRC 200.
Glass properties are based on center of glass values and
are obtained from your glass supplier.
Overall U-Factor, SHGC, and VT Matricies are based on
the standard NFRC specimen size of 2000mm wide by
2000mm high (78-3/4" by 78-3/4").
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.75
0.73
0.90
0.81
0.70
0.68
0.85
0.77
0.65
0.64
0.80
0.72
0.60
0.59
0.75
0.68
0.55
0.55
0.70
0.63
0.50
0.50
0.65
0.59
0.45
0.46
0.60
0.54
0.40
0.41
0.55
0.50
0.35
0.37
0.50
0.45
0.30
0.32
0.45
0.41
0.25
0.28
0.40
0.36
0.20
0.23
0.35
0.32
0.15
0.19
0.30
0.27
0.10
0.14
0.25
0.23
0.05
0.10
0.20
0.18
ADMD020
kawneer.com
© Kawneer Company, Inc., 2014
Overall U-Factor 4
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1" GLAZING WITH
ALUMINUM PRESSURE PLATE
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)
Glass U-Factor 3
EC 97911-086
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
38
1600 Wall SystemTM2 Curtain Wall
DECEMBER, 2015
EC 97911-086
39
THERMAL CHARTS
Note:
Values in parentheses are metric.
COG=Center of Glass.
Charts are generated per AAMA 507.
1" GLAZING WITH FIBERGLASS PRESSURE PLATE
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
System U-Factor for Vision Glass
System U-Factor (Btu/h·ft2·°F)
Vision Area / Total Area (%)
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
COG
U-factor
0.48 (2.72)
0.46 (2.61)
0.44 (2.50)
0.42 (2.39)
0.40 (2.27)
0.38 (2.16)
0.36 (2.05)
0.34 (1.93)
0.32 (1.82)
0.30 (1.71)
0.28 (1.59)
0.26 (1.48)
0.24 (1.37)
0.22 (1.25)
0.20 (1.14)
Notes for System U-Factor, SHGC and VT charts:
For glass values that are not listed, linear interpolation is permitted.
Glass properties are based on center of glass values (winter conditions) and are obtained
from your glass supplier.
kawneer.com
ADMD020
0.30
0.25
0.20
0.15
0.10
0.05
Charts are generated per AAMA 507.
THERMAL CHARTS
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
Vision Area / Total Area (%)
COG
SHGC
0.75
0.70
0.65
0.60
0.55
0.50
0.40
0.35
ADMD020
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1600 Wall SystemTM2 Curtain Wall
kawneer.com
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
0.45
System SHGC
40
DECEMBER, 2015
EC 97911-086
1" GLAZING WITH FIBERGLASS PRESSURE PLATE
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
0.45
0.40
0.35
kawneer.com
System VT
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DECEMBER, 2015
1600 Wall SystemTM2 Curtain Wall
EC 97911-086
0.30
0.25
0.20
0.15
0.10
0.05
Charts are generated per AAMA 507.
ADMD020
41
THERMAL CHARTS
1" GLAZING WITH FIBERGLASS PRESSURE PLATE
System Visible Transmittance (VT) vs Percent of Vision Area
Vision Ares / Total Area (%)
COG
VT
0.75
0.70
0.65
0.60
0.55
0.50
1600 Wall SystemTM2 Curtain Wall
DECEMBER, 2015
EC 97911-086
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
Overall U-Factor 4
0.48
0.54
0.46
0.53
0.44
0.51
0.42
0.49
0.40
0.48
0.38
0.46
0.36
0.44
0.34
0.42
0.32
0.41
0.30
0.39
0.28
0.37
0.26
0.36
0.24
0.34
0.22
0.32
0.20
0.31
NOTE:For glass values that are not listed, linear
interpolation is permitted.
1.
2.
3.
4.
SHGC Matrix 2
U-Factors are determined in accordance with NFRC 100.
SHGC and VT values are determined in accordance with
NFRC 200.
Glass properties are based on center of glass values and
are obtained from your glass supplier.
Overall U-Factor, SHGC, and VT Matricies are based on
the standard NFRC specimen size of 2000mm wide by
2000mm high (78-3/4" by 78-3/4").
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.75
0.73
0.75
0.68
0.70
0.69
0.70
0.63
0.65
0.64
0.65
0.59
0.60
0.60
0.60
0.54
0.55
0.55
0.55
0.50
0.50
0.51
0.50
0.45
0.45
0.46
0.45
0.41
0.40
0.42
0.40
0.36
0.35
0.37
0.35
0.32
0.30
0.33
0.30
0.27
0.25
0.28
0.25
0.23
0.20
0.24
0.20
0.18
0.15
0.19
0.15
0.14
0.10
0.15
0.10
0.09
0.05
0.10
0.05
0.05
ADMD020
kawneer.com
© Kawneer Company, Inc., 2014
Glass U-Factor 3
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1" GLAZING WITH
FIBERGLASS PRESSURE PLATE
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
42