TRU QDS Interface

®
Q D S I N T E R FA C E
.532 MIN
.337
.333
.007
MAX
SLOTS REQUIRED,
DESIGN OF SLOTS OPTIONAL
Ø.194 MIN
1.00
REF
Ø.276 MIN
Ø .627
.625
.623
Ø .619
SEE NOTE 1
.251
.191
.337
.307
.309
MIN
.007 MIN
.040
.003
.415
Ø .411
Ø.485 MIN
Ø.272 MAX
Ø.190 MAX
Ø.374 MAX
.124
Ø.119
.093 MIN
.050 MAX
.124
Ø .119
.092
Ø .090
.303
.273
.309
MAX
REF PLANE
.300
MIN
REF PLANE
Note 1. The ID of contact fingers when inserted into Ø.411 ID max test ring shall be Ø.377 min.
ELECTRICAL
Nominal Impedance
Frequency Range
Voltage Rating
Dielectric Withstanding Voltage
Insulation Resistance
VSWR
MECHANICAL
Mating Characteristics
Connector Durability
Cable Attachement
ENVIRONMENTAL
50 ohms
DC to 6 GHz
1,000 volts rms
3,000 volts rms
5,000 megohms
1.35 max DC - 6 GHz
Temperature Rang:
Vibration
Shock
Moisture Resistance
Corrosion (salt spray)
-67°Fto +390°F (-55°C to +199°C)
MIL-STD-202 Method 204
(Test Cond. B)
MIL-STD-202 Method 213
(Test Cond. I)
MIL-STD-202 Method 106
MIL-STD-202 Method 101
Test Cond. B)
per TRU standards (ref MIL-C-18867A)
500 cycles min.
Clamp
MATERIALS / FINISHES
Body
Contacts (Inner)
Contacts (Outer)
Contacts (Slotted)
Insulators
Gaskets & Seals
Brass, Silver or Nickel Plated
Female: Beryllium Copper, Silver or Gold Plated
Male: Brass, Silver or Gold Plated
Brass, Silver or Nickel Plated
Beryllium, Silver or Nickel Plated
Teflon
Silicone Rubber
TRU Corporation
245 Lynnfield Street, Peabody, MA 01960 1-800-COAX-TRU (1-800-262-9878)