RM96 86 miniature relays • Height 16,2 mm • IP 40 and IP 67 • For PCB (1 C/O, 1 NO, 1 NC) and plug-in sockets (1 C/O) • Accessories: sockets and modules for 1 C/O • DC coils • Recyclable packing • Terminals: 3,2 mm for version 1 C/O, 5,0 mm for version 1 NO and 1 NC • Recognitions, certifications, directives: RoHS, Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load (capacity) AC AC1 AC15 AC3 DC1 DC13 Min. switching current Max. inrush current Rated current Max. breaking capacity Min. breaking capacity Contact resistance Max. operating frequency • at rated load • no load AC1 AC1 1 C/O, 1 NO, 1 NC AgSnO2, AgSnO2/Au 3 µm, AgCdO 250 V / 440 V 10 V AgSnO2, 5 V AgSnO2/Au 3 µm, 10 V AgCdO 8 A / 250 V AC 3 A / 120 V 1,5 A / 240 V (B300) 370 W (single-phase motor, 1/2 HP / 250 V AC UL 508) 8 A / 24 V DC (see Fig. 1) 0,22 A / 120 V 0,1 A / 250 V (R300) 10 mA AgSnO2, 2 mA AgSnO2/Au 3 µm, 5 mA AgCdO 15 A 8A 2 000 VA 1 W AgSnO2, 0,05 W AgSnO2/Au 3 µm, 0,5 W AgCdO ≤ 100 mΩ 600 cycles/hour 72 000 cycles/hour Coil data Rated voltage Must release voltage Operating range of supply voltage Rated power consumption DC DC 5 ... 48 V DC: ≥ 0,1 Un see Table 1 0,22...0,3 W Insulation according to PN-EN 60664-1 Insulation rated voltage Rated surge voltage Overvoltage category Insulation pollution degree Dielectric strength • between coil and contacts • contact clearance Contact - coil distance • clearance • creepage 400 V AC 4 000 V 1,2 / 50 µs III 3 4 000 V AC type of insulation: reinforced 1 000 V AC type of clearance: micro-disconnection ≥ 8 mm ≥ 8 mm General data Operating / release time (typical values) Electrical life • resistive AC1 • cos φ Mechanical life (cycles) Motor load according to UL 508 Dimensions (L x W x H) Weight Ambient temperature Cover protection category Environmental protection Shock resistance Vibration resistance Solder bath temperature Soldering time • storage • operating 10 ms / 5 ms 8 A, 250 V AC > 105 see Fig. 3 > 2 x 107 1/4 HP 120 V AC, single-phase motor 30 x 10 x 16,2 mm 1 C/O: 1 NO, 1 NC: 28 x 10 x 16,2 mm 11 g -40...+85 oC -40...+80 oC IP 40 or IP 67 PN-EN 60529 RTII PN-EN 116000-3 20 g 10 g 10...150 Hz max. 270 oC max. 5 s The data in bold type pertain to the standard versions of the relays. www.relpol.com.pl Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900 RM96 miniature relays 87 Table 1 Coil data - DC voltage version Rated voltage V DC Coil code 1005 1006 1009 1012 1018 1024 1048 Coil operating range at 20 °C V DC Coil resistance ±10% at 20 °C W 5 6 9 12 18 24 48 max. min. 110 160 360 660 1 500 2 200 8 000 3,5 4,2 6,3 8,4 12,6 16,8 33,6 12,0 14,5 22,0 29,5 44,0 54,0 102,0 The data in bold type pertain to the standard versions of the relays. Dimensions Connection diagrams (pin side view) 1 C/O 14 (5) 14 (5) 11 (4) 11 (4) 12 (3) 11 (4) 12 (3) 1 NO, 1 NC A1 (1) A2 (2) A1 (1) A2 (2) A1 (1) A2 (2) 1 C/O 1 NO 1 NC Terminal (pin) [mm] 12(3); 11(4); 14(5) 0,6 x 0,9 0,6 x 1 Ø 1,3 + 0,1 mm Ø 1,5 + 0,1 mm 4 Drilling hole: • for relays A1(1); A2(2) Pinout (solder side view) 1 C/O 3,2 3,2 5 × Ø 1,3 19 2,5 × 2,5 1 NO 5 4 × Ø 1,3 1 NC 19 2,5 × 2,5 5 4 × Ø 1,3 Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900 19 2,5 × 2,5 www.relpol.com.pl RM96 miniature relays 88 Max. breaking capacity A - resistive load DC1 B - resistive load AC1 Fig. 1 Electrical life at AC1 resistive load for version 1 NO Fig. 2 Current [A] AC1 A B Voltage [V] Electrical life reduction factor at AC inductive load Fig. 4 Coil operating range - DC In 8 A Reduction factor n Fig. 3 Power factor Ambient temperature Description of Fig. 4 A - relations between make voltage and ambient temperature at no load on contacts. Coil temperature and ambient temperature are equal before coil energizing. Make voltage is not higher than the value read on Y axis (multiplication of rated voltage). B - relations between make voltage and ambient temperature after initial coil heating up with 1,1 Un, at continues load of In on contacts. Make voltage is not higher than the value read on Y axis (multiplication of rated voltage). 1, 2 - values on Y axis represent allowed overvoltage on coil at certain ambient temperature and contact load: 1 - no load 2 - rated load www.relpol.com.pl Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900 RM96 miniature relays 89 Mounting Relays RM96 1 C/O (one changeover contact) are designed for: • direct PCB mounting • screw terminals plug-in sockets ES 32 ❶ with clip MS16 or GZM80-0041, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting with one M3 screw. Signalling / protecting modules type M... are available with sockets (see page 250). Relays RM96 1 NO (one normally open contact) and RM96 1 NC (one normally closed contact) are designed for direct PCB mounting. ❶ Plug-in sockets ES 32 may be linked with interconnection strip type ZGGZ80 (see page 261). Ordering codes Cover protection category Type Contact material Number and type of contacts Connection mode Coil code Contact material 10 - AgCdO 30 - AgSnO2 32 - AgSnO2/Au 3 µm see Table 1 page 87 Number and type of contacts 11 - 1 C/O 21 - 1 NO 31 - 1 NC Cover protection category 2 - in cover, IP 40 version 3 - in cover, IP 67 waterproof version Connection mode 5 - for PCB (1 C/O, 1 NO, 1 NC) and sockets (1 C/O) Examples of ordering codes: RM96-3011-35-1012 relay RM96, contact material AgSnO 2, with one changeover contact, in cover IP 67, for PCB and sockets, voltage version 12 V DC relay RM96, contact material AgSnO2, with one normally closed contact, in cover IP 40, for PCB, voltage version 24 V DC RM96-3031-25-1024 Print on relay cover Type marking on relays cover RM96 do not match the ordering codes. Example of marking: RM96P-24-W RM96P - relay RM96, with one changeover contact 24 - voltage version 24 V DC W - in cover, IP 67 waterproof version Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900 www.relpol.com.pl Plug-in sockets and accessories for relays RM96 Connection diagram For RM96 1 C/O NC 12 Screw terminals Maximum screw torgue: 0,5 Nm 35 mm rail mount acc. to PN-EN 60715 or on panel mounting 75 x 15,5 x 42,5(59) mm ❷ One pole, 3,2 mm pinout 12 A, 300 V AC NO 14 11 Dimensions COM 59 42,5 15,5 A1 MS16 35 75 A2 19 COIL Ø 3,2 3,2 ZGGZ80 3,2 ES 32 GZM80-0041 7,5 15 24 Accessories ❶ TR Module type M... ❶ ”Mounting and sub-assemblies of accessories in the socket” and ”Signalling / protecting modules type M...” - see www.relpol.com.pl - Product Guide - Type of relay - Additional information. ❷ In the bracket the height of socket with retainer / retractor clip is shown. Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900 www.relpol.com.pl