RM96
86
miniature relays
• Height 16,2 mm • IP 40 and IP 67
• For PCB (1 C/O, 1 NO, 1 NC) and plug-in sockets (1 C/O)
• Accessories: sockets and modules for 1 C/O
• DC coils
• Recyclable packing
• Terminals: 3,2 mm for version 1 C/O,
5,0 mm for version 1 NO and 1 NC
• Recognitions, certifications, directives: RoHS,
Contact data
Number and type of contacts
Contact material
Rated / max. switching voltage
Min. switching voltage
Rated load (capacity)
AC
AC1
AC15
AC3
DC1
DC13
Min. switching current
Max. inrush current
Rated current
Max. breaking capacity
Min. breaking capacity
Contact resistance
Max. operating frequency
• at rated load
• no load
AC1
AC1
1 C/O, 1 NO, 1 NC
AgSnO2, AgSnO2/Au 3 µm, AgCdO
250 V / 440 V
10 V AgSnO2, 5 V AgSnO2/Au 3 µm, 10 V AgCdO
8 A / 250 V AC
3 A / 120 V
1,5 A / 240 V (B300)
370 W (single-phase motor, 1/2 HP / 250 V AC UL 508)
8 A / 24 V DC (see Fig. 1)
0,22 A / 120 V 0,1 A / 250 V (R300)
10 mA AgSnO2, 2 mA AgSnO2/Au 3 µm, 5 mA AgCdO
15 A
8A
2 000 VA
1 W AgSnO2, 0,05 W AgSnO2/Au 3 µm, 0,5 W AgCdO
≤ 100 mΩ
600 cycles/hour
72 000 cycles/hour
Coil data
Rated voltage
Must release voltage
Operating range of supply voltage
Rated power consumption
DC
DC
5 ... 48 V
DC: ≥ 0,1 Un
see Table 1
0,22...0,3 W
Insulation according to PN-EN 60664-1
Insulation rated voltage
Rated surge voltage
Overvoltage category
Insulation pollution degree
Dielectric strength
• between coil and contacts
• contact clearance
Contact - coil distance
• clearance
• creepage
400 V AC
4 000 V
1,2 / 50 µs
III
3
4 000 V AC type of insulation: reinforced
1 000 V AC type of clearance: micro-disconnection
≥ 8 mm
≥ 8 mm
General data
Operating / release time (typical values)
Electrical life
• resistive AC1
• cos φ
Mechanical life (cycles)
Motor load according to UL 508
Dimensions (L x W x H)
Weight
Ambient temperature
Cover protection category
Environmental protection
Shock resistance
Vibration resistance
Solder bath temperature
Soldering time
• storage
• operating
10 ms / 5 ms
8 A, 250 V AC
> 105
see Fig. 3
> 2 x 107
1/4 HP
120 V AC, single-phase motor
30 x 10 x 16,2 mm
1 C/O:
1 NO, 1 NC: 28 x 10 x 16,2 mm
11 g
-40...+85 oC
-40...+80 oC
IP 40 or IP 67
PN-EN 60529
RTII
PN-EN 116000-3
20 g
10 g 10...150 Hz
max. 270 oC
max. 5 s
The data in bold type pertain to the standard versions of the relays.
www.relpol.com.pl
Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900
RM96
miniature relays
87
Table 1
Coil data - DC voltage version
Rated voltage
V DC
Coil code
1005
1006
1009
1012
1018
1024
1048
Coil operating range at 20 °C
V DC
Coil resistance
±10% at 20 °C
W
5
6
9
12
18
24
48
max.
min.
110
160
360
660
1 500
2 200
8 000
3,5
4,2
6,3
8,4
12,6
16,8
33,6
12,0
14,5
22,0
29,5
44,0
54,0
102,0
The data in bold type pertain to the standard versions of the relays.
Dimensions
Connection diagrams (pin side view)
1 C/O
14 (5)
14 (5)
11 (4)
11 (4)
12 (3)
11 (4)
12 (3)
1 NO, 1 NC
A1 (1) A2 (2)
A1 (1) A2 (2)
A1 (1) A2 (2)
1 C/O
1 NO
1 NC
Terminal (pin)
[mm]
12(3); 11(4); 14(5)
0,6 x 0,9
0,6 x 1
Ø 1,3 + 0,1 mm
Ø 1,5 + 0,1 mm
4
Drilling hole:
• for relays
A1(1); A2(2)
Pinout (solder side view)
1 C/O
3,2 3,2
5 × Ø 1,3
19
2,5 × 2,5
1 NO
5
4 × Ø 1,3
1 NC
19
2,5 × 2,5
5
4 × Ø 1,3
Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900
19
2,5 × 2,5
www.relpol.com.pl
RM96
miniature relays
88
Max. breaking capacity
A - resistive load DC1
B - resistive load AC1
Fig. 1
Electrical life at AC1 resistive load
for version 1 NO
Fig. 2
Current [A]
AC1
A
B
Voltage [V]
Electrical life reduction factor
at AC inductive load
Fig. 4
Coil operating range - DC
In 8 A
Reduction factor
n
Fig. 3
Power factor
Ambient temperature
Description of Fig. 4
A - relations between make voltage and ambient temperature at
no load on contacts. Coil temperature and ambient temperature
are equal before coil energizing. Make voltage is not higher than
the value read on Y axis (multiplication of rated voltage).
B - relations between make voltage and ambient temperature
after initial coil heating up with 1,1 Un, at continues load of In on
contacts. Make voltage is not higher than the value read on Y
axis (multiplication of rated voltage).
1, 2 - values on Y axis represent allowed overvoltage on coil at
certain ambient temperature and contact load:
1 - no load
2 - rated load
www.relpol.com.pl
Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900
RM96
miniature relays
89
Mounting
Relays RM96 1 C/O (one changeover contact) are designed for: • direct PCB mounting • screw terminals plug-in
sockets ES 32 ❶ with clip MS16 or GZM80-0041, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting with
one M3 screw. Signalling / protecting modules type M... are available with sockets (see page 250).
Relays RM96 1 NO (one normally open contact) and RM96 1 NC (one normally closed contact) are designed for direct
PCB mounting.
❶ Plug-in sockets ES 32 may be linked with interconnection strip type ZGGZ80 (see page 261).
Ordering codes
Cover protection
category
Type
Contact
material
Number and type
of contacts
Connection
mode
Coil code
Contact material
10 - AgCdO
30 - AgSnO2
32 - AgSnO2/Au 3 µm
see Table 1 page 87
Number and type of contacts
11 - 1 C/O
21 - 1 NO
31 - 1 NC
Cover protection category
2 - in cover, IP 40 version
3 - in cover, IP 67 waterproof version
Connection mode
5 - for PCB (1 C/O, 1 NO, 1 NC) and sockets (1 C/O)
Examples of ordering codes:
RM96-3011-35-1012
relay RM96, contact material AgSnO 2, with one changeover contact, in cover IP 67,
for PCB and sockets, voltage version 12 V DC
relay RM96, contact material AgSnO2, with one normally closed contact, in cover IP 40,
for PCB, voltage version 24 V DC
RM96-3031-25-1024
Print on relay cover
Type marking on relays cover RM96 do not match the ordering codes.
Example of marking:
RM96P-24-W
RM96P - relay RM96, with one changeover contact
24
- voltage version 24 V DC
W
- in cover, IP 67 waterproof version
Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900
www.relpol.com.pl
Plug-in sockets and accessories
for relays RM96
Connection diagram
For RM96 1 C/O
NC
12
Screw terminals
Maximum screw torgue: 0,5 Nm
35 mm rail mount acc. to PN-EN 60715
or on panel mounting
75 x 15,5 x 42,5(59) mm ❷
One pole, 3,2 mm pinout
12 A, 300 V AC
NO
14
11
Dimensions
COM
59
42,5
15,5
A1
MS16
35
75
A2
19
COIL
Ø 3,2
3,2
ZGGZ80
3,2
ES 32
GZM80-0041
7,5
15
24
Accessories ❶
TR
Module type M...
❶ ”Mounting and sub-assemblies of accessories in the socket” and ”Signalling / protecting modules type M...” - see www.relpol.com.pl - Product Guide - Type of relay
- Additional information.
❷ In the bracket the height of socket with retainer / retractor clip is shown.
Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900
www.relpol.com.pl