RM85 with increased contact gap miniature relays 1 • Increased contact gap • Cadmium - free contacts • Height 15,7 mm • 5000 V / 10 mm reinforced insulation • For PCB • DC coils • Recyclable packing • Certifications, directives: RoHS, Contact data Number and type of contacts Contact material Max. switching voltage Min. switching voltage Rated load Min. switching current Max. inrush current Rated current Max. breaking capacity Min. breaking capacity Contact resistance Max. operating frequency • at rated load • no load AC AC1 AC1 AC1 1 NO AgSnO2 480 V 10 V 5 A / 480 V AC 10 mA 15 A 5A 2 400 VA 1W ≤ 100 mΩ at 100 mA, 24 V 360 cycles/hour 3 600 cycles/hour Coil data Rated voltage Must release voltage Operating range of supply voltage Rated power consumption DC DC 3...110 V ≥ 0,1 Un see Table 1 0,4...0,48 W Insulation Insulation category Rated surge voltage Overvoltage category Insulation pollution degree Dielectric strength • between coil and contacts • contact clearance Contact - coil distance • clearance • creepage B400 4 000 V AC III PN-EN 60664-1 2 5 000 V AC 1 500 V AC ≥ 10 mm ≥ 10 mm General data Operating time (typical value) Release time (typical value) Electrical life • at resistive load Mechanical life Loads - UL508 Dimensions (L x W x H) Weight Ambient temperature • storage • operating Cover protection category Environmental protection Shock resistance Vibration resistance Solder bath temperature Soldering time 7 ms 3 ms 3 600 cycles/hour > 4 x 104 5 A, 480 V AC > 3 x 107 Heavy Pilot Duty 480 V AC, 15 A make / 1,5 A break 29 x 12,7 x 15,7 mm 14 g -40...+85 oC -40...+85 oC IP 40 RTII PN-EN 116000-3 30 g 10 g 10...150 Hz max. 270 oC max. 5 s The data in bold type pertain to the standard versions of the relays. Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900 www.relpol.com.pl RM85 with increased contact gap miniature relays 2 Table 1 Coil data - DC voltage version 1003 1005 1006 1009 1012 1018 1024 1036 1048 1060 1110 Coil operating range at 20 °C V DC Coil resistance ±10% at 20 °C W Rated voltage V DC Coil code 3 5 6 9 12 18 24 36 48 60 110 22 60 90 200 360 710 1 440 3 140 5 700 7 500 25 200 min. max. 2,1 3,5 4,2 6,3 8,4 12,6 16,8 25,2 33,6 42,0 77,0 7,6 12,7 15,3 22,9 30,6 45,9 61,2 91,8 122,4 153,0 280,0 The data in bold type pertain to the standard versions of the relays. Connections diagram (pin side view) Dimensions 14 (8) 24 (5) 29 12,7 7,5 11 (7) 21 (4) 5 5 15 A1 (1) A2 (2) 2,5 1 NO 3,9 15,7 Terminal (pin) PCB layout / terminal assignment (solder side view) 6 × Ø 1,3 www.relpol.com.pl 22(3); 21(4); 24(5); 12(6); 11(7); 14(8) [mm] Ø 0,6 0,5 x 0,9 Drilling hole: • for relays Ø 1,3 + 0,1 mm RM85 with increased contact gap terminals are doubled for each contact. Both terminals are to be used while connecting to load. Mounting Relays RM85 with increased contact gap are designed for direct PCB mounting. 1 NO 5 A1(1); A2(2) 20 2,5 × 2,5 Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900 RM85 with increased contact gap miniature relays 3 Ordering codes Cover protection category Type Contact material Number and type of contacts Connection mode Contact material Coil code see Table 1 page 2 30 - AgSnO2 Number and type of contacts 51 - 1 NO, increased contact gap Cover protection category 2 - in cover, IP 40 version Connection mode 5 - for PCB Example of ordering code: RM85-3051-25-1012 relay RM85, contact material AgSnO2, with one normally open contact, with increased contact gap, in cover IP 40, for PCB, voltage version 12 V DC Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900 www.relpol.com.pl