Datasheet

Mounting and sub-assemblies
240
of the relay and accessories in the socket
Signalling / protecting module
type M...
Electromagnetic relays
Removing the relay from the socket
with a retrainer / retractor clip
Retainer / retractor clip
Description plate
Screw terminals
plug-in socket
Accessories
retainer / retractor clips and description plates
Type
of plug-in socket
GZT80, GZT92,
GZM80, GZM92
GZS80, GZS92
GZ96
GZT2, GZT3, GZT4,
GZM2, GZM3, GZM4
Type
GZT80-0040
GZS-0040 ❶
MS16
GZT4-0040
Colour
black
black
black
black
Type
GZT80-0035
TR
TR
GZT4-0035
Colour
white
white
white
white
Designed for relays
RM84, RM85,
RM85 inrush,
RM85 105 °C sensitive,
RM87, RM87 sensitive
RM84, RM85,
RM85 inrush,
RM85 105 °C sensitive,
RM87, RM87 sensitive
RM96 1 C/O
R2, R3, R4
Height of relay
15...16,5 mm
15...16,5 mm ❶
15...16,5 mm
35,6 mm
Retainer / retractor
clips
Description plates
❶ Relpol S.A. offers also retainer / retractor clip GZS-0025 designed for relays of the height 25...26 mm.
www.relpol.com.pl
Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900
Signalling / protecting modules
type M...
Modules type M...
241
Layout
Voltage
Type of module ❶
6/230 V DC
M21P
6/230 V DC
M21N
6/24 V DC
24/60 V DC
110/230 V DC
M31R, M31G
M32R, M32G
M33R, M33G
6/24 V DC
24/60 V DC
110/230 V DC
M41R, M41G
M42R, M42G
M43R, M43G
6/24 V AC
24/60 V AC
110/240 V AC
M51
M52
M53
6/24 V AC/DC
24/60 V AC/DC
110/230 V AC/DC
M61R, M61G
M62R, M62G
M63R, M63G
6/24 V AC/DC
24/60 V AC/DC
110/230 V AC/DC
M91R, M91G
M92R, M92G
M93R, M93G
It limits overvoltage on AC and DC coils.
No indication.
24 V AC
130 V AC
230 V AC
M71
M72
M73
Module R
110/230 V AC
M103
Module D (polarization P)
It limits overvoltage on DC coils.
Module D (polarization N)
It limits overvoltage on DC coils.
Module LD (polarization P)
It limits overvoltage on DC coils.
Coil energizing indication.
Module LD (polarization N)
For sockets type:
GZT80, GZT92,
GZM80, GZM92,
GZS80, GZS92,
GZ96,
It limits overvoltage on DC coils.
Coil energizing indication.
Module RC
GZT2, GZT3, GZT4,
GZM2, GZM3, GZM4
It protects against EMC disturbance.
It limits overvoltage.
Module L
Coil energizing indication.
Module LV
It limits overvoltage on AC and DC coils.
Coil energizing indication.
Module V
It limits overvoltage on AC coils.
❶ M...R - LED red colour
M...G - LED green colour
Modules type M... are parallely connected with relay coil. Polarity P: -A1/+A2. Polarity N: +A1/-A2.
Additional features
for industrial relays
Type ❷
Description
For industrial relays
W
mechanical indicator
R15 2 C/O, R15 3 C/O,
R2, R3, R4
T
lockable front test button, orange colour AC coils, green colour - DC coils
R15 2 C/O, R15 3 C/O,
R2, R3, R4
L
light indicator (LED diode),
located inside the relay
R15 2 C/O, R15 3 C/O, R15 4 C/O,
RUC, R2, R3, R4, RY2
D
surge suppresion element (diode)
- only for DC coils
R15 2 C/O, R15 3 C/O, R15 4 C/O,
R2, R3, R4, RY2
V
surge suppresion element (varistor)
- only for AC coils
R15 2 C/O, R15 3 C/O
K
test button without block function
R15 4 C/O, RUC
WT - mechanical indicator + lockable front test button
Standard features for industrial relays: R15 2 C/O, R15 3 C/O, R2, R3, R4.
❷ Available combinations:
WT, WTL, WTD, WTLD, WTV, WTLV - relays for plug-in sockets: R15 2 C/O, R15 3 C/O.
WT, WTL, WTD, WTLD - relays for plug-in sockets: R2, R3, R4
K, L, D, KL, KD, KLD - relays for plug-in sockets R15 4 C/O.
K, L, KL - relays RUC.
Detailed information for individual relays: see Ordering codes - Additional features.
Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900
www.relpol.com.pl
Plug-in sockets and accessories
availability index
242
The relays not specified in the table are designed for other manners of mounting.
Relays mounting options are specified in the table, page 244, 245.
Plug-in sockets
Type of relay
Screw terminals
Solder
terminals
For PCB mounting
On panel mounting
35 mm rail mount
acc. to PN-EN 60715
RM699BV, RSR30 ❶
–
–
–
PI6W-1P
RM84
–
(EC50, PW80 ❷)
(GD50 ❸)
GZT80, GZM80
(GZS80 ❹)
GZT80, GZM80
(GZS80 ❹)
RM85
–
(EC50, PW80 ❷)
(GD50 ❸)
GZT80, GZM80
(GZS80 ❹)
GZT80, GZM80
(GZS80 ❹)
RM85 inrush
–
(EC50, PW80 ❷)
(GD50 ❸)
GZT80, GZM80
(GZS80 ❹)
GZT80, GZM80
(GZS80 ❹)
RM85 105 °C sensitive
–
(EC50, PW80 ❷)
(GD50 ❸)
GZT80, GZM80
(GZS80 ❹)
GZT80, GZM80
(GZS80 ❹)
RM87N, RM87N sensitive
–
(EC35 ❷)
(GD35 ❸)
GZT92, GZM92
(GZS92 ❹)
GZT92, GZM92
(GZS92 ❹)
RM87L, RM87L sensitive
–
(EC50, PW80 ❷)
(GD50 ❸)
GZT80, GZM80
(GZS80 ❹)
GZT80, GZM80
(GZS80 ❹)
RM87P, RM87P sensitive
–
(EC50, PW80 ❷)
(GD50 ❸)
GZT80, GZM80
(GZS80 ❹)
GZT80, GZM80
(GZS80 ❹)
RM96 1 C/O
–
–
GZ96
GZ96
R2
(SU4/2L ❺)
(G4/2 ❻)
SU4/2D ❻
GZT2, GZM2
GZT2, GZM2
R3
–
–
GZT3, GZM3
GZT3, GZM3
R4
(SU4L ❺)
(G4 ❻)
SU4D ❻
GZT4, GZM4
(GZ4 ❼), (GS4 ❼ ❽)
GZT4, GZM4
(GZ4 ❼), (GS4 ❼ ❽)
RY2
–
–
GZY2 ①
GZY2 ①
R2M
G2M ②
S2M ②
GZ2 ③
GZ2 ③
Miniature relays
Miniature industrial relays
Industrial relays of small dimensions
R15 2 C/O
GOP8 ④
–
(PZ8 ⑤)
(GZ8 ⑥)
GZS8, (GZP8 ⑦)
(PZ8 ⑤)
(GZU8 ⑥)
GZS8, (GZP8 ⑦)
R15 3 C/O
GOP11 ④
–
(PS11, PZ11 ⑤)
(GZ11 ⑥)
GZS11, (GZP11 ⑦)
(PS11, PZ11 ⑤)
(GZU11 ⑥)
GZS11, (GZP11 ⑦)
R15 4 C/O
GOP14 ④
–
GZ14, GZ14Z
GZ14U
RUC faston 4,8 x 0,5
–
–
GUC11
GUC11
–
–
GZT4, GZM4
GZT4, GZM4
Time relays
T-R4
❶ Solid state relays RSR30 type - see catalogue ”Solid state relays” and www.relpol.com.pl
❷ For EC50, PW80, EC35, EC32 sockets apply spring wire clips MH16-2
❸ For GD50, GD35 sockets apply spring wire clips GD-0016
❹ For GZS80, GZS92 sockets apply retainer / retractor clips GZS-0040 and description plates TR
❺ For SU4/2L, SU4L sockets apply spring wire clips G4 1053 or G4 1050 and spring clamps G4 1040
❻ For SU4/2D, SU4D, G4/2, G4 sockets apply spring wire clips G4 1053 or G4 1050
❼ For GZ4, GS4 sockets not applicable retainer / retractor clips GZT4-0040, description plates GZT4-0035, modules type M...
and interconnection strip type ZGGZ4
❽ For GS4 sockets apply spring wire clips GS4-0036 and description plates GS4-0035
❾ Information on buttons (no latching) R4P-0001, R15-M404 and plugs R4W-0003, R15-M203 - see page 248.
www.relpol.com.pl
Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900
Plug-in sockets and accessories
availability index
243
Additional features
Accessories
Signalling /
protecting
modules
Spring wire clips
Retainer /
retractor clips
Description
plates
–
–
PI6W-1246
–
interconnection strip type ZG20
(MH16-2 ❷), GZM80-0041
(GD-0016 ❸)
GZT80-0040
(GZS-0040 ❹)
GZT80-0035
(TR ❹)
type M...
interconnection strip type ZGGZ80
(MH16-2 ❷), GZM80-0041
(GD-0016 ❸)
GZT80-0040
(GZS-0040 ❹)
GZT80-0035
(TR ❹)
type M...
interconnection strip type ZGGZ80
(MH16-2 ❷), GZM80-0041
(GD-0016 ❸)
GZT80-0040
(GZS-0040 ❹)
GZT80-0035
(TR ❹)
type M...
interconnection strip type ZGGZ80
(MH16-2 ❷), GZM80-0041
(GD-0016 ❸)
GZT80-0040
(GZS-0040 ❹)
GZT80-0035
(TR ❹)
type M...
interconnection strip type ZGGZ80
(MH16-2 ❷), GZM80-0041
(GD-0016 ❸)
GZT80-0040
(GZS-0040 ❹)
GZT80-0035
(TR ❹)
type M...
interconnection strip type ZGGZ80
(MH16-2 ❷), GZM80-0041
(GD-0016 ❸)
GZT80-0040
(GZS-0040 ❹)
GZT80-0035
(TR ❹)
type M...
interconnection strip type ZGGZ80
(MH16-2 ❷), GZM80-0041
(GD-0016 ❸)
GZT80-0040
(GZS-0040 ❹)
GZT80-0035
(TR ❹)
type M...
interconnection strip type ZGGZ80
GZM80-0041
MS16
TR
type M...
interconnection strip type ZGGZ80
(G4 1053, G4 1050 ❺ ❻)
G4 1052
GZT4-0040
GZT4-0035
type M...
interconnection strip type ZGGZ4
test buttons, plugs ❾
G4 1052
GZT4-0040
GZT4-0035
type M...
interconnection strip type ZGGZ4
test buttons, plugs ❾
(G4 1053, G4 1050 ❺ ❻)
G4 1052, (GS4-0036 ❽)
GZT4-0040 ❼
(GZT4-0035 ❼)
(GS4-0035 ❽)
type M... ❼
(interconnection strip type ZGGZ4 ❼)
test buttons, plugs ❾
GZY 2000 ①
–
–
–
–
(G4 1050 ②), (GZ2 1060 ③)
–
–
–
–
(R159 1051 ④), (PZ11 0031 ⑤)
(GZ 1050, GZU 1052 ⑥)
(GZP-0054 ⑦)
–
GZP-0035 ⑦
–
(test buttons, plugs ❾)
(time module T(COM3) ⑦)
(R159 1051 ④), (PZ11 0031 ⑤)
(GZ 1050, GZU 1052 ⑥)
(GZP-0054 ⑦)
–
GZP-0035 ⑦
–
(test buttons, plugs ❾)
(time module T(COM3) ⑦)
(R15 0736 ④), GZ14 0737
–
–
–
–
MBA
–
–
–
–
TR4-2000
–
GZT4-0035
–
interconnection strip type ZGGZ4
① For GZY2 sockets apply spring wire clips GZY 2000 and spring clamps GZ2 1111
② For G2M sockets apply spring wire clips G4 1050 and spring clamps G2M 1020
For S2M sockets apply spring wire clips G4 1050
③ For GZ2 sockets apply spring wire clips GZ2 1060 and spring clamps GZ2 1111
④ For GOP8, GOP11 sockets apply spring wire clips R159 1051 and spring clamps R15 5922
For GOP14 sockets apply spring wire clips R15 0736 and spring clamps R15 5922
⑤ For PZ8, PS11, PZ11 sockets apply spring wire clips PZ11 0031
⑥ For GZ8, GZ11 sockets apply spring wire clips GZ 1050
For GZU8, GZU11 sockets apply spring wire clips GZU 1052
⑦ For GZP8, GZP11 sockets apply spring wire clips GZP-0054, description plates GZP-0035 and time modules T(COM3)
Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900
www.relpol.com.pl
Relays mounting options
244
Type of relay
Method of mounting
For PCB mounting
On panel
mounting
35 mm rail
mount acc. to
PN-EN 60715
Cover with
mounting
flange
- on panel
mounting
Flat insert
connectors
- faston
Subminiature signal relays
RSM850
direct
–
–
–
–
–
RSM850B
direct
–
–
–
–
–
RSM822
direct
–
–
–
–
–
RSM832
direct
–
–
–
–
–
RSM954
direct
–
–
–
–
–
RSM957
direct
–
–
–
–
–
RM40
direct
–
–
–
–
–
RM50
direct
–
–
–
–
–
RM699BV, RSR30 ❶
direct
–
–
with socket
–
–
RM699H
direct
–
–
–
–
–
RM84
direct
with socket
with socket
with socket
–
–
RM84 SMT
direct
–
–
–
–
–
RM85
direct
with socket
with socket
with socket
–
–
RM85 ✪
direct
–
–
–
–
–
RM85 inrush
direct
with socket
with socket
with socket
–
–
RM85 105 °C sensitive
direct
with socket
with socket
with socket
–
–
RM85 SMT
direct
–
–
–
–
–
RM85 faston
direct
–
–
–
–
6,3 x 0,8 mm
RM87N
direct
with socket
with socket
with socket
–
–
RM87N sensitive
direct
with socket
with socket
with socket
–
–
RM87L
direct
with socket
with socket
with socket
–
–
RM87L sensitive
direct
with socket
with socket
with socket
–
–
RM87P
direct
with socket
with socket
with socket
–
–
RM87P sensitive
direct
with socket
with socket
with socket
–
–
RM87N SMT
direct
–
–
–
–
–
RM96 1 C/O
direct
–
with socket
with socket
–
–
RM96 1 NO, 1 NC
direct
–
–
–
–
–
RM83
direct
–
–
–
–
–
RM92
direct
–
–
–
–
–
RM94
direct
–
–
–
–
–
direct
–
–
–
–
–
Miniature relays
Automotive relays
RA2
Miniature industrial relays
R2
direct
with socket
with socket
with socket
–
–
R3
–
–
with socket
with socket
–
–
R4
direct
with socket
with socket
with socket
–
–
RY2
–
–
with socket
with socket
on request
4,8 x 0,5 mm
R2M
direct
with socket
with socket
with socket
–
–
www.relpol.com.pl
Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900
Relays mounting options
245
Type of relay
Method of mounting
For PCB mounting
On panel
mounting
35 mm rail
mount acc. to
PN-EN 60715
Cover with
mounting
flange
- on panel
mounting
Flat insert
connectors
- faston
Industrial relays of small dimensions
R15 2 C/O
direct
–
with socket
with socket
–
–
R15 3 C/O
direct
–
with socket
with socket
–
–
R15 4 C/O
–
–
with socket ❷
with socket
–
–
RUC faston 4,8 x 0,5
direct
–
with socket ❸
with socket ❸
on request
4,8 x 0,5 mm
direct ❹
RUC faston 6,3 x 0,8
–
–
–
direct ❹
on request
6,3 x 0,8 mm
RG25
–
–
–
direct
–
–
R20
–
–
direct
–
standard
6,3 x 0,8 mm
PI84 with socket GZT80
–
–
direct
direct
–
–
PI85 with socket GZT80
–
–
direct
direct
–
–
PI84 with socket GZM80
–
–
direct
direct
–
–
PI85 with socket GZM80
–
–
direct
direct
–
–
PIR2 with socket GZM2
–
–
direct
direct
–
–
PIR3 with socket GZM3
–
–
direct
direct
–
–
PIR4 with socket GZM4
–
–
direct
direct
–
–
PI6-1P
–
–
–
direct
–
–
PI6-1T
–
–
–
direct
–
–
PI6-OC
–
–
–
direct
–
–
PIR6W-1P-...
–
–
–
direct
–
–
PIR6W-1PS-...- ❺
–
–
–
direct
–
–
PIR6WB-1PS-...- ❺
–
–
–
direct
–
–
–
–
–
direct
–
–
MT-TUA-...
–
–
–
direct
–
–
MT-TUB-...
–
–
–
direct
–
–
MT-T..-..
–
–
–
direct
–
–
MT-TSD-...
–
–
–
direct
–
–
TR4N 4 C/O
–
–
–
direct
–
–
TR4N 1 C/O, 2 C/O
–
–
–
direct
–
–
T-R4
–
–
with socket
with socket
–
–
PIR15...T ❻
–
–
direct
direct
–
–
Interface relays
Installation relays
MT-PI-...
Time relays
✪ RM85 with increased contact gap
❶ Solid state relays RSR30 type - see catalogue ”Solid state relays” and www.relpol.com.pl
❷ Available socket to be mounted behind the assembly panel - GZ14Z.
❸ For RUC faston 4,8 x 0,5 with GUC11 socket max. switching voltages and coil voltages of relays are limited to 250 V AC/DC.
❹ Version with adaptor: (V) or (H).
❺ R - operational electromagnetic relay RM699BV type for PIR6W.-1PS-...-R.
T/C/O - operational solid state relay RSR30 type for PIR6W.-1PS-...-T (C or O) - see catalogue ”Solid stete relays” and www.relpol.com.pl
❻ With time module T(COM3).
Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900
www.relpol.com.pl
Plug-in sockets technical data
246
Plug-in socket
Terminals type
Insulation
Insulation
rated voltage
Rated
current
(PN-EN 60664-1)
Dielectric strength 50/60 Hz, 1 min.
between
coil and contacts
pole - pole
GZT80
for screw terminals
300 V AC
12 A
5000 V AC
3000 V AC
GZM80
for screw terminals
300 V AC
12 A
5000 V AC
3000 V AC
GZS80
for screw terminals
300 V AC
10 A
4000 V AC
2500 V AC
EC50
for PCB
300 V AC
8A
6 kV (1,2 / 50 µs)
2000 V AC
PW80
for PCB
250 V AC
8A
2000 V AC
2000 V AC
GD50
for PCB
300 V AC
8A
2000 V AC
2000 V AC
GZT92
for screw terminals
300 V AC
12 A
5000 V AC
–
GZM92
for screw terminals
300 V AC
12 A
5000 V AC
–
GZS92
for screw terminals
300 V AC
12 A
4000 V AC
–
EC35
for PCB
300 V AC
12 A
6 kV (1,2 / 50 µs)
–
GD35
for PCB
300 V AC
12 A
2000 V AC
–
GZ96
for screw terminals
300 V AC
12 A
4000 V AC
–
EC32
for PCB
300 V AC
12 A
6 kV (1,2 / 50 µs)
–
GZT2
for screw terminals
300 V AC
12 A
3000 V AC
3000 V AC
GZM2
for screw terminals
300 V AC
12 A
4000 V AC
3000 V AC
SU4/2D
for PCB
250 V AC
12 A
2500 V AC
2500 V AC
SU4/2L
for solder terminals
250 V AC
12 A
2500 V AC
2500 V AC
G4/2
for solder terminals
250 V AC
12 A
2500 V AC
2500 V AC
GZT3
for screw terminals
300 V AC
10 A
3000 V AC
3000 V AC
GZM3
for screw terminals
300 V AC
10 A
4000 V AC
3000 V AC
GZT4
for screw terminals
300 V AC
6A
3000 V AC
3000 V AC
GZM4
for screw terminals
300 V AC
6A
4000 V AC
3000 V AC
GZ4
for screw terminals
300 V AC
7A
2500 V AC
2000 V AC
GS4
for screw terminals
300 V AC
6A
2500 V AC
2000 V AC
SU4D
for PCB
250 V AC
6A
2500 V AC
2000 V AC
SU4L
for solder terminals
250 V AC
6A
2500 V AC
2000 V AC
G4
for solder terminals
250 V AC
6A
2500 V AC
2000 V AC
GZY2
for screw terminals
250 V AC
12 A
2000 V AC
2000 V AC
GZ2
for screw terminals
250 V AC
7A
2000 V AC
2000 V AC
S2M
for PCB
250 V AC
5A
2000 V AC
2000 V AC
G2M
for solder terminals
250 V AC
5A
2000 V AC
2000 V AC
PZ8
for screw terminals
250 V AC
10 A
2500 V AC
2500 V AC
GZU8
for screw terminals
300 V AC
10 A
2500 V AC
2500 V AC
GZ8
for screw terminals
300 V AC
10 A
2500V AC
2500 V AC
GZS8
for screw terminals
300 V AC
10 A
2000 V AC
2000 V AC
GZP8
for screw terminals
300 V AC
12 A
4000 V AC
2500 V AC
GOP8
for solder terminals
250 V AC
10 A
2000 V AC
2000 V AC
PS11
for screw terminals
250 V AC
10 A
2000 V AC
2000 V AC
PZ11
for screw terminals
250 V AC
10 A
2000 V AC
2000 V AC
GZU11
for screw terminals
250 V AC
10 A
2000 V AC
2000 V AC
GZ11
for screw terminals
250 V AC
10 A
2000 V AC
2000 V AC
GZS11
for screw terminals
300 V AC
10 A
2000 V AC
2000 V AC
GZP11
for screw terminals
300 V AC
12 A
2500V AC
2000 V AC
GOP11
for solder terminals
250 V AC
10 A
2000 V AC
2000 V AC
GZ14U
for screw terminals
250 V AC
10 A
2000 V AC
2000 V AC
GZ14
for screw terminals
250 V AC
10 A
2000 V AC
2000 V AC
GOP14
for solder terminals
250 V AC
10 A
2000 V AC
2000 V AC
GZ14Z
for screw terminals
250 V AC
10 A
2000 V AC
2000 V AC
GUC11
for screw terminals
250 V AC
16 A
2000 V AC
2000 V AC
PI6W-1P
for screw terminals
250 V AC
6A
4000 V AC
–
❶ Also relays RM85 inrush, RM85 105 °C sensitive
www.relpol.com.pl
❷ Also versions RM87L sensitive, RM87P sensitive
❸ Also versions RM87N sensitive
Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900
Plug-in sockets technical data
247
General data
Terminal capacity
For relays
Ambient
temperature
(operating)
Protection
category
(PN-EN 60529)
Maximum
screw torgue
2
-40...+70 oC
IP 20
0,7 Nm
2 x 2,5 mm2
RM84, (RM85 ❶), (RM87L, RM87P ❷)
2
-40...+70 oC
IP 20
0,7 Nm
2 x 2,5 mm2
RM84, (RM85 ❶), (RM87L, RM87P ❷)
2
-40...+85
oC
IP 20
0,5 Nm
2 x 2,5 mm
RM84, (RM85 ❶), (RM87L, RM87P ❷)
2
-40...+85 oC
–
–
–
RM84, (RM85 ❶), (RM87L, RM87P ❷)
2
-40...+85 oC
–
–
–
RM84, (RM85 ❶), (RM87L, RM87P ❷)
2
-40...+85
oC
–
–
–
RM84, (RM85 ❶), (RM87L, RM87P ❷)
1
-40...+70 oC
IP 20
0,7 Nm
2 x 2,5 mm2
RM87N ❸
1
-40...+70 oC
IP 20
0,7 Nm
2 x 2,5 mm2
RM87N ❸
1
-40...+85 oC
IP 20
0,5 Nm
2 x 2,5 mm2
RM87N ❸
1
-40...+85
oC
–
–
–
RM87N ❸
1
-40...+85 oC
–
–
–
RM87N ❸
1
-40...+85 oC
IP 20
0,5 Nm
–
RM96 1 C/O
1
-40...+85
oC
–
–
–
–
2
-40...+70 oC
IP 20
0,7 Nm
2 x 2,5 mm2
R2
2
-40...+70 oC
IP 20
0,7 Nm
2 x 2,5 mm2
R2
2
-40...+70 oC
–
–
–
2
-40...+70
oC
–
2
-40...+70 oC
–
3
-40...+70 oC
3
Number
of poles
Maximum
size of wires
(multi-cable)
2
R2
–
2 x 0,75 mm
2
R2
–
2 x 0,75 mm2
R2
IP 20
0,7 Nm
2 x 2,5 mm2
R3
-40...+70 oC
IP 20
0,7 Nm
2 x 2,5 mm2
R3
4
-40...+70
oC
IP 20
0,7 Nm
2
2 x 2,5 mm
R4, T-R4
4
-40...+70 oC
IP 20
0,7 Nm
2 x 2,5 mm2
R4, T-R4
4
-40...+70 oC
IP 20
0,7 Nm
2 x 1,5 mm2
R4
4
-40...+70
oC
IP 20
0,7 Nm
2 x 1,5 mm
R4
4
-40...+70 oC
–
–
–
R4
4
-40...+70 oC
–
–
–
R4
4
-40...+70 oC
–
–
2 x 0,75 mm2
R4
2
-40...+70
oC
IP 00
0,7 Nm
2 x 2,5 mm
RY2
2
-40...+70 oC
IP 20
0,7 Nm
2 x 2,5 mm2
R2M
2
-40...+70 oC
–
–
–
R2M
2
-40...+70 oC
–
–
–
2
-40...+70
oC
IP 20
2
-40...+70 oC
IP 00
2
-40...+70 oC
2
2
R2M
0,7 Nm
2
2 x 2,5 mm
R15 2 C/O
0,7 Nm
2 x 2,5 mm2
R15 2 C/O
IP 00
0,7 Nm
2 x 2,5 mm2
R15 2 C/O
2
-40...+70
oC
IP 00
1,0 Nm
2
2 x 2,5 mm
R15 2 C/O
2
-40...+70 oC
IP 20
0,5 Nm
2 x 2,5 mm2
R15 2 C/O
2
-40...+70 oC
–
–
–
R15 2 C/O
3
-40...+70 oC
IP 20
0,7 Nm
2 x 2,5 mm2
R15 3 C/O
3
-40...+70
oC
IP 20
0,7 Nm
2
2 x 2,5 mm
R15 3 C/O
3
-40...+70 oC
IP 00
0,7 Nm
2 x 2,5 mm2
R15 3 C/O
3
-40...+70 oC
IP 00
0,7 Nm
2 x 2,5 mm2
R15 3 C/O
3
-40...+70 oC
IP 00
1,0 Nm
2 x 2,5 mm2
R15 3 C/O
3
-40...+70 oC
IP 20
0,5 Nm
2 x 2,5 mm2
R15 3 C/O
3
-40...+70 oC
–
–
–
R15 3 C/O
4
-40...+70 oC
IP 00
0,7 Nm
2 x 2,5 mm2
R15 4 C/O
oC
4
-40...+55
IP 00
0,7 Nm
2 x 2,5 mm
R15 4 C/O
4
-40...+70 oC
–
–
–
R15 4 C/O
4
-40...+55 oC
IP 00
0,7 Nm
2 x 2,5 mm2
R15 4 C/O
3
-40...+70 oC
IP 00
0,7 Nm
2 x 2,5 mm2
1
oC
IP 20
0,3 Nm
1 x 2,5 / 2 x 1,5 mm
-40...+55
2
RUC
2
RM699BV, RSR30 ❹
❹ Solid state relays RSR30 type - see catalogue ”Solid state relays” and www.relpol.com.pl
Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900
www.relpol.com.pl
Test buttons (no latching) and plugs
248
Test buttons are recommended for R2...WT, R3...WT, R4...WT, R15...WT 2 C/O, R15...WT 3 C/O relays - for
applications that do not allow permanent contact latching. By manual operation (pressing the button) relay
contacts can get switched for as long time as long the button is pressed. Contacts return to initial position as soon
as pressure is released from the button. Those operations can be done while the coil is deenergized.
Button R4P-0001 or R15-M404 can be easily inserted
by the Customer after removal of button type T (see
Fig. 2). Button type T can be removed with screwdriver
as shown on Fig. 1.
Fig. 1
Dimensions - test button R15-M404
for relays R15...WT 2 C/O, R15...WT 3 C/O
13,7 - 0,2
11,7 - 0,2
Dimensions - test button R4P-0001
for relays R2...WT, R3...WT, R4...WT
Fig. 2
Ø 3,35 - 0,05
5,75
5,5
Ø 3,5 - 0,1
11,6
13,4
Types of buttons:
R4P-0001-A - orange colour (AC coils)
R4P-0001-D - green colour (DC coils)
Types of buttons:
R15-M404-A - orange colour (AC coils)
R15-M404-D - green colour (DC coils)
Plugs R4W-0003 or R15-M203 can substitute button type T if manual operation (latching and testing) is not
allowed. Changing button type T for plug can be done by Customer themselves in the same way as changing button
type T for button (no latching).
Dimensions - plug R15-M203
for relays R15...WT 2 C/O, R15...WT 3 C/O
9,3
10,36 - 0,05
Dimensions - plug R4W-0003
for relays R2...WT, R3...WT, R4...WT
Ø 3,40 - 0,12
Ø 3,50 - 0,03
R
R
6,43-0,03
5,95-0,1
8
2,
7
2,
R
17,23 ± 0,03
Types of plugs:
R4W-0003-A - orange colour (AC coils)
R4W-0003-D - green colour (DC coils)
www.relpol.com.pl
5
2,
10,28 - 0,03
Types of plugs:
R15-M203-A - orange colour (AC coils)
R15-M203-D - green colour (DC coils)
Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900