ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: Pico Product #: 471xxxHF Series Issue Date: March 9, 2010 It is hereby certified by Littelfuse, Inc. that there is neither RoHS (EU Directive 2002/95/EC)-restricted substance nor such use, for materials to be used for unit parts, for packing/packaging materials, and for additives and the like in the manufacturing processes. In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing processes, are all composed of the following components. Issued by: <Global EHS Engineer> (1) Parts, sub-materials and unit parts This document covers the Pico RoHS-Compliant series products manufactured by Littelfuse, Inc. < Raw Materials Used Please see Table 1 (2) The ICP data on all measurable substances Please see appropriate pages as identifed in Table 1 Remarks: Pb (lead) contained in the high temperature melting solder > 85% and is categorized as exempt under section 7a of the RoHS Annex. Form 585-047 Rev. A 1 2/21/06 Table 1: List of Raw Materials covered by this report Total Parts 1 2 3 4 5 6 7 Raw Material Part Number 909-144 497xxx 687xxx-001 082xxx 692320 910-263 087340 Raw Material Description Body Cu Clad Fe58 42Ni5Ag by weight Wire Brass Sn Plated Wire Element - 99% Cu Solder Cap and Lead Assembly Epoxy Powder (HF Gold) 2 Page(s) 3-8 9-13 14-22 23-27 28-32 33-37 38-43 Test Report Applicant: Number : TWNC00141509 Littelfuse, Inc. 800 E. NORTHWEST HWY DESPLAINES IL 60016 Date : Dec 09, 2009 Sample Description: One (1) group of submitted samples said to be : Part Description : Body Part Number : 909-144 Date Sample Received : Dec 04, 2009 Date Test Started : Dec 04, 2009 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory. Page 1 Of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00141509 Test Conducted (Ⅰ) Test Result Summary : Testing Item Result (ppm) Grey Material Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Halogen Content Fluorine (F) Chlorine (Cl) Bromine (Br) Iodine (I) ND 52 ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND Remarks: ppm = Parts per million based on weight of tested sample = mg/kg ND = Not detected Responsibility Of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received Testing Period : Dec 04, 2009 : Dec 04, 2009 To Dec 08, 2009 Page 2 Of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00141509 Test Conducted (Ⅱ) RoHS Requirement: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr6+) Content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ehters (PBDEs) Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. (Ⅲ) Test Method: Testing Item Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) Halogen Content Testing Method With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in annex C, by alkaline digestion and determined by UV-Vis spectrophotometer. With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary. With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary. With reference to EN 14582:2007 by combustion flask with oxygen and determined by ion chromatography Reporting Limit 2 ppm 2 ppm 2 ppm 1 ppm 5 ppm 5 ppm 50 ppm Remark: Reporting limit = Quantitation limit of analyte in sample Page 3 Of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00141509 Test Conducted (Ⅳ) Measurement Flowchart: Test For Cd/Pb/Hg/Chromium (VI)/PBBs/PBDEs Contents Reference Standard: IEC 62321 edition 1.0:2008 Page 4 Of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00141509 Test Conducted (Ⅳ) Measurement Flowchart: Test For Halogen Content Reference Standard: EN 14582 sampling/grinding or cutting add absorbent in a combustion flask & place weighed sample in equipment fill the combustion flask with oxygen ignite then leave the flask at room temperature transfer the absorbent into a volumetric flask make up with deionized water analyzed by ion chromatography End Of Report Page 5 Of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00141509 Test Conducted Photo Page 6 Of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Test Report Applicant: Number : TWNC00139518 Littelfuse, Inc. 800 E. Northwest Hwy Desplaines IL 60016 Date : Nov 20, 2009 Sample Description: One (1) group of submitted samples said to be : Sample Description : Element-Ag plated dumet Style / Item No. : 497238 Date Sample Received : Nov 17, 2009 Date Test Started : Nov 18, 2009 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory. Page 1 Of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00139518 Test Conducted (Ⅰ) Test Result Summary : Testing Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content (mg/kg with 50cm2) Result (ppm) Silvery Metal Wire ND ND ND Negative (< 0.02) Remarks: ppm = parts per million based on weight of tested sample = mg/kg ND = Not Detected < = Less Than mg/kg with 50cm2 = milligram per kilogram with 50 square centimeter Negative = A negative test result indicated positive observation was not found at the time of testing. When the spot test showed a negative result, the boiling water extraction procedure shall be used to verify the result. Responsibility Of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received Testing Period : Nov 17, 2009 : Nov 18, 2009 to Nov 20, 2009 (Ⅱ) RoHS Requirement: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr6+) Content Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. Page 2 Of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00139518 Test Conducted (Ⅲ) Test Method: Testing Item Testing Method With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion Cadmium (Cd) content until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion Lead (Pb) content until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the Mercury (Hg) content tested samples are totally dissolved and determined by ICPOES. With reference to IEC 62321 edition 1.0:2008 in annex B, by Chromium VI (Cr6+) content boiling water extraction and determined by UV-Vis spectrophotometer. Reporting Limit 2 ppm 2 ppm 2 ppm 0.02 mg/kg with 50cm2 Remark: Reporting Limit = Quantitation limit of analyte in sample Page 3 Of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00139518 Test Conducted (Ⅳ) Measurement Flowchart: Test For Cd/Pb/Hg/Chromium (VI) Reference Standard:IEC 62321 edition 1.0:2008 End Of Report Page 4 Of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00139518 Test Conducted Photo Page 5 Of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 sGs rnfff,+E+ For Ques-ti PleaseCo www.tw.s ffi46(No.) : cE/2009/c6831 E*I(Date) : 2070/01/07 F.*(P'g") Test Report nown Validit ith SGS : I of 9 GMBH EHCHUKOMELEKTROSCHUTZKOMPONENTENBAU 87, D-98669 VEIISDORF, GERMANY GEWERBESTRASSE g&*P+#fr&.*P4t8*eT t(Ttilfi,&$tfrhflPng&, identified of bylon behalf the client t*.3" A t&$^^p I e Descr i pt i on) tfltr'4fi,(style/I : : t e m N o .) ( T h e f o l l o w i n g s a m p l e sw a s / w e r es u b n i t t e d a n d as) ! WIRES TINNTED (1) 101- - 271. 0 - - WIRE - Cu, Sn - - 2o E\{N 02.02 - TINNEDCOPPER ( 2 ) 1 0 1 - - 2 8 3 . 0 - - CLADWIRE - ELCON30, Sn - - % EWN02.02 - TINNEDCOPPER (3) 101- - 272. 0 - - CLAD WIRE - ELCONF, Sn - - % EWN02.02 - TINNEDCOPPER ( 4 ) 1 0 1 - - 2 8 r . 0 - - CLADWIRE - ErcON D, Sn - - % EWN02.02 - TINNEDCOPPER ( 5 ) 1 0 1 - - 2 4 - . 0 - - WIRE - Cu, Ag--%, EWN02.02 - TINNEDSILVERPLATEDCOPPER S n - - % ( 6 ) 1 0 1 - - 2 5 7 . 0 - - EWN12.02 - TINNEDBMSS WIRE - Cu80Zn20, Sn - - % ( 7 ) r 0 1 - - 2 3 2 . 0 - - ALLOYWIRE - AgCu50, Sn - - % EWN04.02 - TINNEDSILVERCOPPER ( 8 ) 1 0 1 - - 2 3 4 . 0 - - ALLoY WIRE - AgCu90, Sn - - % EWN03.06 - TINNEDSILVER COPPER (Etcugo,sn--%) (e) lo1 - - - 58. 0 - - AILOY I{IRE - ZnMn0.03%, EWN08.06 - TINNEDZINC MANGANESE S n - - % o o ) l 0 r - - 2 5 5 . TINNEDCOPPER ZINC ALLOYWIRE - Cu70Zn30, Sn - - % ( 1 1 ) 1 0 r - - 2 2 9 TINNEDCOPPER NICKELALLOYWIRE - CuNil2, Sn - - oh . F E E I ( C o u n t r yo f O r i g i n ) 4t{t EiX(sa'ple ReceivingDate) ,nl-;J[*nFl (Tes t i ns Per i od) , lF*El (cnRrueNY) z 2009/12/30 : 2 0 0 9 / 1 2 / 3 0T O 2 0 1 0 / 0 1 / 0 7 lilff,SJR(f.st Results) . 'ahfl,n' { (Please ref er to next pages). l{anager Signedfor and on of SGSTAIWAT{ LID. Chemicallaborabry - Taipei w )FI H -#aA' ftffi €tt R{4$iiFrl n{2E FaF_F " +# S *f$#aE Affi# "I' 4 E]"lrn€S{ " offende.s may be pro54uted to the fullest extent ofthe law. 6n&&{+&[s6}E.FR,.\F]chemica|{aipe|''1:.|.Tl"::ol**:'"o:...l"]'*:' Memberofthe SGSGroup (SGSSA) SGS rfla#+ Test Report r *n(o't") :2010/0r/0T F'*(page) :2 of e f f i a € ( N o . :) c E / 2 0 0 e l c 6 8 3 E EISCHUKOMELEKTROSCHUTZKOMPONENTENBAU GMBH GEWERBESTRASSE 87, D-98669 VEIISMRF, GERMANY il4g,I**.(Tes t Resul t s ) ,n'JA+{A(PART NAME)NO.1 'Ec)n'li'ft6ffiO#&!* G&.8) (ltttti) (MIXED ALLcoloRMErALwIRE (INCLUDINGTHE PLATINGLAYER) (1I KINDS)) ,r{fi,{[E (Test Itens) $ 6 / C a d m i u m( C d ) F.fn ,rtg,t* (Uni t ) (Method) ng/kg s* ,*.ft,rl ETF{fi (Result) (ilDL) NO.1 2 n .d . 2 51 2 n .d . 0.02ng/kg N e g at i v e **rcr 6x2r: 2oo8)fr*,vxdrG.# +E&/'A+*4t;b-#&&tl'l' / with reference to IEC 62321: 2008 and performed bv ICP-AES. 45 / Leaa (Pb) ng/kg **trc 6232r:2oo8ti*, yx&r€.+ts +EfrR+&4t{;*&,*Ar,l. / witt' reference to IEC 62321:2008 and performed by ICP-AES. *. / Mercury (Hg) mg/kg 4-4rcc 6232r:zoos)fr*, vxAzG.{* 6E xR+ *# )ti*&.**ia{' / witt' reference to IEC 62321: 2008 and performed by ICP-AES. ^ i f r e * / H e x a v a l e n t C h r o m i u nC r ( V I ) b y S p o t t e s t / b o iI i n g w a t e r extract i on ^-*tsc test 6232r: 2oo8)fi|, r,xSpot / boiling i*hXl wi th water extractionf au cm. . / With ref erence to IEC 62327: 2008 and performed by Spot surface test / boi I ing water extract ion Method. (See Note 5) / Perf luorooctane sulfonates (PFOS) PFOS Acid Afi"+H,&#. PFOS PFOS - ng/kg *tus EpA3540c:Lsegr-&, v\i:R_td / E *frg i8H.h,n{Afi.+H,&&-+8. 1 9 9 6 m e t h o d f o r P F O SC o n t e n t . Amide Analysis was performed by LCIMS. / PFoA(cls No.: ooo335- 10 n .d . l0 n .d . With reference to US EPA 3540C: Metal Salt Af(+#($*) 67-r) ar ea mg/kg *tus EPA3540c:rse6t)*, y\iAM a#r+Ef.(dr) dE . / E *t H'"Ve.e,!{ With reference to US EPA 3540C: 1996 method for P F O AC o n t e n t . Analysis was performed by LCIMS. W)Fts H'ifrEA'fi ffi#$* RI4SJiFJF{,Zifi f i F.F " + tr € X f,g4 /!\A = 6;f Ej' T "I*FAlF 9{ " offendeJs may be p.os(uted to the fullest extent ofthe law. AiEfff+'n&i'HFR/^6.]chemiCal-Taipei33wuchyuanRoad.wuku|ndustria|zone,Taipeicounty,Taiwan/6J|]ffI*EfEEa Member ofthe sGSGroup (SGSSA) SGS tF{"d,+E+ ffin6(No.) : cEl2009/c6831 E*n(oate) : 2010/0r/0T F*.(page) : 3 of e Test Report EISCHUKOMELEK?ROSCHUTZKOMPONENTENBAU GMBH GEWERBESTRASSE 87, D-98669 VEIBMRF. GERMANY ,ilS,4l E *tt (Test Itens) t il#*Stt' illitt* (Unit ) (Method) t*4Hnt EfEIE (MDL) / Sun of PBBs -;ft#F / Monobromobiphenvl :r*#A{ / Dibromobiphenyl g* ( R e s u lt NO.1 n .d . n .d . n .d . = )4#f / Tribromobiphenvl 5 n .d . !9tA#X / Tetrabromobiohenvl ( n .d . 4?*#X / Pentabromobiphenyl *t*#X( -kr4#ts / Hexabromobiphenvl / H e p t a b r o m o bpi h e n v l n .d . N4#F )U*WF / Octabromobiphenyl n .d . / N o n a b r o m o bpih e n y l +t*#X / D e c a b r o m o bp h e n y I n .d . n .d . mg/kg t AIFXEtfi3ft / su' or PBDEs *4tuc 6232r:2oo8t)*, vxfi"taE ttL&,tHlg'&*jP,.l.z with reference to IEC 6232t: n .d . n .d . 2008 and performed n ,d . -?*#Edt / Monobromodiphenvl ether :t4#4i6d. / D i b r o m o d i p h e n v le t h e r n .d . :rF#4Sd / T r i b r o m o d i p h e n y le t h e r n .d . E7*#X6t / T e t r a b r o m o d i p h e n v le t h e r .f.)4#X6e,/ by cClMS. q n .d . P e n t a b r o m o d i p h e n yelt h e r q n .d . n .d . *t*#XEt -ktA#fEt / H e x a b r o m o d i p h e n vel t h e r E p ih e n v l e t h e r / Heptabromod R ,\?4#X6e / O c t a b r o m o d i p h e n v le t h e r itt*#Fe / N o n a b r o m o d i p h e n vel t h e r / D e c a b r o m o d i p h e n yel t h e r +t*#Fnt 6*' n .d . n .d . n.d. q n .d . 50 n .d . 50 n .d . 50 n .d . 50 n .d . z Halogen ( f r . ) / H a l o g e n - F l u o r i n e( F ) ( C A S At ) , 1 o: . 0 1 4 7 6 2 - 9 4 - 8 ) (ft) / Halogen-chlorine(Cl) 6t ( C A SN o . : 0 2 2 5 3 7 - t ' - I ) 6 . n .d . (r*) / Halogen-Bromine (Br) **ss (CAS ) , 1 o . :0 1 0 0 9 7 - 3 2 - 2 ) 6 f r ( 4 R ) / H a l o g e n - I o d i n e( I ) No.: 014362-44-8) ng/kg EN14b82:2ool , v'/,ilEtElt& h\fr. / With reference to BS EN 14582:2007A . nalysis was performed by IC. (cAS UnlessotheNise stated the results shown in t w)FBH'#EA'ft W# fr* RtC$JiF{diZ tfiff F.H . 4 # g *#i+,.i 6t= m*+aj,z.4*Ft Ery " offenders may be pros(uted to the fullest extent ofthe law. aiFiffi+f&#)EIE Member ofthe SGSGroup (sGSSA) trf-d,#+ f f i , 4 5 ( u.o) : c E /2 o o 9 l c 6 8 3 1 E * I ( o a t e ) : 2 o r o / o t / 0 7 Test Report F#.(Page):4of9 EISCHUKOMELEKTROSCHUTZKOMPONENTENBAU GMBH GEWERBESTRASSE 87, D-98669 VEIISMRF. GERMANY ffi?i(Note) : 1. mglkg = ppr i 0.lwt% = 1000ppm 2. n.d. = Not Detect.d (*,h*) 3 . I ! ! D L= M e t h o d D e t e c t i o n L i m i t ( a r * { A ; n , J * e F R , f 6 . ) 4. "-" = Not Regutatea (.ft*i.f6,f,6.) 5 . S p o t- t e s t : N e g a t i v e = A b s e n c e o f c r ( v I ) c o a t i n g / s u r f a c e t a y " t ( f f i - E f , f A , F , J6 5 ' l * , t F d t ) , Positive = Presence of Cr(VI) coating / surface tay"t(&-Ef,fA,erl5tl x.fF48); T h e t e s t e d s a m p l es h o u l d b e f u r t h e r v e r i f i e d b y b o i l i n g - w a t e r - e x t r a c t i o nm e t h o di f the s p o t t e s t r e s u l t c a n n o tb e c o n f i r m e d . ( 6 ?t tF{tF * }*tE;g F+,,F{ -Jt*itr" 4 ** fr I o i I i ng -wat e r - ex t r a c t i oninrl?{? i}i€ - + 4i& ) B o i I i n g - w a t e r - e x t r a cito n : N e g a t i v e = A b s e n c eo f C r ( V I ) c o a t i n g / s u r f a c e t a y e r ( f i E f , f A , F ' . 1 6 t ' J * . t F t S ) , P o s i t i v e = P r e s e n c eo f C r ( V I ) c o a t i n g , / s u r f a c e l a y e r ( $ t , E f , f A X ' l t ' .;1r , f F 1 S ) ; the detected concentration in boiling-water-extraction greater than 0.02 ng/kg with f^',Ei,k-;HA>0.02 6. **= Qualitative analysis 50 crz .arpl. solution is equal or surface area. ng/kg wi th 50 cm2 (sample surf ace area) (No unit) .€,l4.rr\tf.(*+.fa) 7. ii.e6-trFfa&x.r+F?Fr-*,frBa;F,la' +E+ftrl,,ca'F{.6{,*+RT,{t,t+f,fElt{s--+ttsfie€. ( T h e s a m p l e sw a s / w e r e a n a l y z e do n b e h a l f o f t h e a p p l i c a n t a s m i x i n g s a m p l e i n o n e t e s t i n g . T h e a b o v e r e s u l t s w a s / w e r eo n l y g i v e n a s t h e i n f o r m a l i t y v a l u e . ) PFOS**titl(Reference Infornation) : JBA 2006/122lEc (Directive 2006,/122lEc) ( 1) i^ *trH 6'LA,;| fi 4 -t 4..Rn r!++4.*hH fi"e & te"r.€ €,H.4 +,Ard.^r,t 0. 00b% . (May not be placed on the market or used as a substance or constituent of preparations in a concentration equal to or higher than 0.005 % by mass. (2) i bttw4qEtafij#I60+/rLf"4.6 /t!i#Et+LEfl&l&,4apFosfr_+p^**I\LA&.*qisi€-tit4 """fr"Xifhr+t PFos€ E IRAS'*d" n;*ro. r%, dab &,3"a + 4&, fr H,*hF, + *pFosEfr H,*hH f e€ + rad.d;it rug/,2 . (May not be placed on the market in semi-finished products or articles, concentration of PFOS is equal to or higher mass of structurally or microstructurally coated materials, the amount of if or parts thereof, than 0.1 % by mass calculated distinct with p a r t s t h a t c o n t a i n P F O So r , PFOSis equal to or higher than lpg/m2 of if the reference to the for textiles or other the coated material.) w)FfrH'frl[, rt#frf*Rl$$Jiq{ifrzt*Faae." +ffi€*ffi+/^a=6;+FI , Tit*[n&* " offendeE may be prosecuted to the fullest extent ofthe law. aEf!h{+f&1'€-FRAachemica|-Taipei33wUchyuanRoad.wuku|ndustria|zone.TaipeicoUnty.Taiwan/6i|:I&I+EIE86 Member ofthe SGSGrcup (SGSSA) SGS ,Ff-d,+t+ Test Report f f i 4 € i ( N o . ): c E / 2 0 0 9 / c 6 8 3 1E * n ( o , t e ) : 2 0 1 0 / 0 1 / 0 7 { g ( p a g e ) :5 of e EISCHUKOMELEKTROSCHUTZKOMPONENTENBAU GMBH GEWERBESTRASSE 87, D-98669 VEILSMRF. GERMANY 1 ) fpifrxT6t;tr,42ffi<'{'Fl+, +t3"L?-^,SA+ " ( x,fFltxrlatz.*htl. ) /Thesesampteswere dissolved totallyby preconditioning methodaccording to belowflowchart.( Cf* testmethodexcluded) yang 2) f{'ai/. F : *k lftf / Nameof the personwho mademeasurement: Climbgreat : 3) ,F{-;{,F A. person / Name of the in iFBR chargeof measurement: f TroyChang g *, . flffi+t$ / Cutting. Preparation r{;{+t S€€ / Sample Measurement i,fFrt $.&T n #:" {.ttt F at u. 6€ 6t1 #.&4i i'H 4U(tpTFna,) /Aciddigestionby suitable aciddepended on different sample material(asbelowtable) EH#.t fi*.t ELfl.#.6t& tAtH.lb Microwave digestion with HN03/HCUHF C16* ,6aottg;P1,'r* , ooo appropriate amountof digestionreagent n"*4d.€BA€li'ti{ 4?,4-WI Heatto appropriate temperature to extract aafti.ie,aiis / Cool,filterdigestrate through filter eA#+€ *zF+ *+l )L*&. / lcP-AEs fr.!"ttK / SampleMaterial / Digestion )'H4Y.&.I&+9M Acid ffi, ffi, E, EbA t L/R, tH#.,S#., ftfi.#., €ft'K / Steel. coooer aluminum solrler Aoua reoia. HNO" HCI HF HoC)" l{e4 / Glass rA#, ft ftd E, 4e,N., W:f, t -t+ /Aquaregia / HNO3/HF Gold. olatinum. oalladium enramie v>t#rl/o-;l fljt ;Yi,* iR / SiMer 48 / Plastic rH# /HNO" 4'f8 / Others ns)\1+Fl&AZ+iE# | Anyacidto totaldigestion 4.#.,qfr.^, rrt[t, sEt / HrSOa ),o^*e*l#.e lAdd diphenylcarbazide for colordevelopment HrOr F{NOq F{Cl fi, ' €iFl+is,tsri{rr. 540nmtr*.\\-E I measurethe absorlcance at 540 nm by UV-VIS w)FBH-etEA' H,#*te R{g$Jifl ilfr2.+tffiF F " *ffi g *,is+ /^Ft= 6 ;f nI, 4 EI*[ntFfl " offendeJs may be pros<uted to the fullest extent ofthe law. 6iBfHf+f&1'€-pEAd.chemka|.Taipei33wuchyuanRoad,wUkU|ndustrialzone,Taipeicounty,Taiwan/6lL'ff[I*E6rf6 Member ofthe SGSGroup (SGS5A) scs tn{-d,#+ Test Report f f i { P $ ( N o . :) c E /2 o o s l c 6 8 3 1 q $ p( D a t e ) : 2 0 1 0 / 0 1 / 0 7 f i * . ( P a g e ) : 6 o f 9 ilMffitil[[rIllllunllnl GMBH EISCHUKOMELEKTROSCHUTZKOMPONENTENBAU 87, D-98669 VEILSMRF, GERMANY GEWERBESTRASSE f, / f d,+8(Lc/Ms)+ff')fi,4 Analytical flow chart of Soxhlet extraction (LC/MS)procedure LydiaFu : 144fiXE / Nameof the personwho mademeasurement: 1 ) ,n,l-6{,AF ShinjyhChen 2) ,F,l';{ tl / Nameof the personin chargeof measurement: A fi' , : I'R*4 r trf?{,'E +fr\+h&#./Afi.+e(6f)' X-fi:4.fr'l?+*h t EOestltems): . Benzotriazole PFOS/PFOA *iA / Data l.t* FaF,H " + ffi# X f;g+/!\E € ffifl+"I' T E-I*[r]?€5A" W1FBH #EA' H # € $*Ri4$JiqU#i offenders may be prosecuted to the fullest extent ofthe law 6nfff++{&i,}E.FR^-dcheTi:l-Ta|ee'::*::n*:i.:::.*:111:.l',i*:.':|Ti.*lo,]:':*1a Member ofthe SGSG.ogp (SGSSA) tF{'d,+t+ Test Report f f i , { F ( N o) . : c E / 2 0 0 9 / c 6 8 3 r E S X ( D " t " ): 2 o r o / o l / 0 7 f i ' f r ( P a g e ) : 7 o f 9 rmffi[|iltLtullltHilllnl GMBI{ EISCHUKOMELEKTROSCHUTZKOMPONENTENBAU 87, D.98669 VEILSMRF, GERMANY GEWERBESTRASSE t'&#*/, FLOWCHART analytical / PBB/PBDE l*#fatlnrfr'en RomanWong whomademeasurement 1),ilA,l.F z'itMW / Nameoftheperson person ShinjyhChen : measurement: in charge of / Name of the 2) ;nrl?i,F ,r. rjF*f'tl fi. 4n)Na'li*+?ft i Firsttestingprocess + ,g#,l4ffiiAtEF I Optionatscreenprocess process €ifl"frEE / Confirmation l a t t t t t t t r l r l t l a l : l l l l l a a l l l l l a t l l l t _ l I I I iaffitttt analysis Screen I a a I I I t a t I t a l a a l a a r I t r r 1 r I I I I I l a l a t I a a a I I t V solution iluteExtracted Concentrate/D #qr,,t,RfiA/ffi# Y Filter/ #R,rtn9;l€ V lssueReport#+f*E+ W)F$E#aA' ft#6f6*{4$Jiq{#iLffiF,F.H " +ffi €*fg*AA=6-afEI' T4*finffiry " offendeE may be pros4uted to the fullest extent ofthe law. ARftf+ffi#iHFRAF]chemical-Taipei33wuchyuanRoad,wuku|ndustria|zone,Taipeicounty,Taiwan/6J|jfI]:*EItEE Member ofthe sGS Group (sGSsA) SGS tn{-d,#+ f f i r 6 ( N o .) : c E / 2 0 0 9 / c 6 8 3 1E * I l ( o a t e ) : 2 0 1 0 / 0 1 / 0 7 F * ( P a s e ) Test Report : 8 of 9 ililn]tililI]|||ilil][Inil]llll ELSCHUKOM ELEKTROSCHUTZKOMPONENTENBAU GMBH 87, D.98669 VEIISDORF, GERMANY GEWERBESTRASSE **+,if fi,&n I Analyticalflow chart of halogencontent 1) ,nl'a\,1-F: f*s{6 / Nameof the personwho mademeasurementAlanChen TroyChang 2) ,F{at A i, - : tFBq / Nameof the personin chargeof measurement: w+E*t4&"h'ttt by lC Analysiswasperformed ztfrF"F.H." + ffi€ * f,g+e\A= Ei;+"]' 4'-J*lrr]tFfl " w)FBH'frEA'rtr# g fidR14Hiq[#i offenders may be prostruted to thefullest extent ofthe law 6Efhf++{fn€.pF. Memberofthe SGsGroup(SGssA) sGs rn{a#+ Test Report f f i n 6 ( N o . ): C E / 2 0 0 e l C 6 8 3E1f i l ( D a t e ) : 2 0 1 0 / 0 1 / 0 7E * ( P a g e ) : 9 of 9 iln]ililllllllilillilillililllillilllll GMBH ELSCHUKOM ELEKTROSCHUTZKOMPONENTENBAU 87, D-98669 VEIISDORF, GERMANY GEWERBESTRASSE , * * + k + ! + E ( E n d o f R e p o r t )* + Z& FaF.A' + ffig t{g + /!\.:l= 6 A+!I''I "I*[r] tFS{" W)FtsH'#FA,ft ffig fteRE SiiEt];"\ offenders may be prosecuted to thefullest efrent ofthe law. 6i8fff+ffsi'EpRAF]chemica|-TaiPei33wuchyuanRoad,Wuku|ndu5tria|zone.Taipeicounty,Taiwan/f.lfiHI*@6€[B Member of the 5GSGroup (SGS5A) Intertek Testing Services Ltd., Shanghai TFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 E-mail: [email protected] www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338 TEST REPORT APPLICANT: LITTELFUSE,INC. 800 E. NORTHWEST HWY ATTN: A.DIVIETRO/D.UNTIEDT NUMBER: SHAH00176754 DATE: FEB 10, 2010 SAMPLE DESCRIPTION: One (1) group of submitted samples said to be Coppery Wire. Part Description : Element. Part Number : 99% Cu 082xxx. Date Sample Received : Feb.3, 2010. Date Test Started : Feb.3, 2010. *********************************************************************** TESTS CONDUCTED: AS REQUESTED BY THE APPLICANT, FOR DETAILS REFER TO ATTACHED PAGE(S) *********************************************************************** TO BE CONTINUED PREPARED AND CHECKED BY: FOR INTERTEK TESTING SERVICES LTD., SHANGHAI AUTHORIZED BY: FOR INTERTEK TESTING SERVICES LTD., SHANGHAI MYRA LV CHEMICAL DIVISION MANAGER STEPHEN TSANG GENERAL MANAGER PAGE 1 OF 5 Intertek Testing Services Ltd., Shanghai TFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 E-mail: [email protected] www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338 TEST REPORT NUMBER: SHAH00176754 TESTS CONDUCTED (I) Test Result Summary : Testing Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content (mg/kg with 50cm2) Result (ppm) ND ND ND ND Remarks: ppm = Parts per million = mg/kg ND = Not detected mg/kg with 50cm2 = milligram per kilogram with 50 square centimetre Responsibility Of Chemist : Dent Fang (II) RoHS Requirement: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr6+) Content Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. ********************************************************************** TO BE CONTINUED PAGE 2 OF 5 Intertek Testing Services Ltd., Shanghai TFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 E-mail: [email protected] www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338 TEST REPORT NUMBER: SHAH00176754 TESTS CONDUCTED (III) Test Method: Testing Item Testing Method Reporting Limit With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by Cadmium (Cd) microwave digestion until the 2 ppm content tested samples are totally dissolved and determined by ICPOES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the Lead (Pb) content 2 ppm tested samples are totally dissolved and determined by ICPOES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave Mercury (Hg) digestion until the tested samples 2 ppm content are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 0.02 Chromium VI (Cr6+) 1.0:2008 in annex B, by boiling mg/kg with content water extraction and determined by 50cm2 UV-Vis spectrophotometer. Remark: Reporting limit = Quantitation limit of analyte in sample Date Sample Received : Feb.3, 2010 Testing Period : Feb.3, 2010 TO Feb.8, 2010 ********************************************************************** TO BE CONTINUED PAGE 3 OF 5 Intertek Testing Services Ltd., Shanghai TFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 E-mail: [email protected] www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338 TEST REPORT NUMBER: SHAH00176754 TESTS CONDUCTED (IV) Measurement Flowchart: Test For Cd/Pb/Hg/Chromium (VI) Reference Standard:IEC 62321 edition 1.0:2008 ********************************************************************** TO BE CONTINUED PAGE 4 OF 5 Intertek Testing Services Ltd., Shanghai TFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 E-mail: [email protected] www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338 TEST REPORT NUMBER: SHAH00176754 TESTS CONDUCTED ******************************************************************* END OF REPORT PAGE 5 OF 5 Test Report Applicant: Number : TWNC00141510 Littelfuse, Inc. 800 E. Northwest Hwy Desplaines IL 60016 Date : Dec 09, 2009 Sample Description: One (1) group of submitted samples said to be : Part Description : Solder Part Number : 692320 Date Sample Received : Dec 04, 2009 Date Test Started : Dec 04, 2009 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory. Page 1 Of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00141510 Test Conducted (Ⅰ) Test Result Summary : Testing Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content (mg/kg with 50cm2) Result (ppm) Silvery Metal ND 850739 ND Negative (< 0.02) Remarks: ppm = Parts per million based on weight of tested sample = mg/kg ND = Not detected < = Less than mg/kg with 50cm2 = milligram per kilogram with 50 square centimetre Negative = A negative test result indicated positive observation was not found at the time of testing. Responsibility Of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received Testing Period : Dec 04, 2009 : Dec 04, 2009 to Dec 09, 2009 (Ⅱ) RoHS Requirement: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr6+) Content Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. Page 2 Of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00141510 Test Conducted (Ⅲ) Test Method: Testing Item Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Testing Method With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in annex B, by boiling water extraction and determined by UV-Vis spectrophotometer. Reporting Limit 2 ppm 2 ppm 2 ppm 0.02 mg/kg with 50cm2 Remark: Reporting limit = Quantitation limit of analyte in sample Page 3 Of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00141510 Test Conducted (Ⅳ) Measurement Flowchart: Test For Cd/Pb/Hg/Chromium (VI) Reference Standard:IEC 62321 edition 1.0:2008 End Of Report Page 4 Of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00141510 Test Conducted Photo Page 5 Of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Test Report Applicant: Number : TWNC00132836 Littelfuse, Inc. 800 E. NORTHWEST HWY DESPLAINES IL 60016 Date : Sep 29, 2009 Sample Description: One (1) group of submitted samples said to be : Sample Description : Cap/ Lead Assay (A)Base meterial (B)Plating Style / Item No. : 910-263 Date Sample Received : Sep 23, 2009 Date Test Started : Sep 24, 2009 Test Conducted: As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory. Page 1 Of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00132836 Test Conducted (Ⅰ) Test Result Summary : Testing Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content (mg/kg with 50cm2) Result (ppm) (A) (B) ND ND ND Negative (< 0.02) ND ND ND Negative (< 0.02) Remarks: ppm = Parts per million based on weight of tested sample = mg/kg ND = Not detected < = Less than mg/kg with 50cm2 = milligram per kilogram with 50 square centimetre Negative = A negative test result indicated positive observation was not found at the time of testing. Responsibility Of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received Testing Period : Sep 23, 2009 : Sep 24, 2009 To Sep 28, 2009 (Ⅱ) RoHS Requirement: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr6+) Content Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. Page 2 Of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00132836 Test Conducted (Ⅲ) Test Method: Testing Item Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Remark: Testing Method With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in annex B, by boiling water extraction and determined by UV-Vis spectrophotometer. Reporting Limit 2 ppm 2 ppm 2 ppm 0.02 mg/kg with 50cm2 Reporting limit = Quantitation limit of analyte in sample Page 3 Of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00132836 Test Conducted (Ⅳ) Measurement Flowchart: Test For Cd/Pb/Hg/Chromium (VI) Reference Standard:IEC 62321 edition 1.0:2008 End Of Report Page 4 Of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00132836 Test Conducted Photo Page 5 Of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Test Report Applicant: Number : TWNC00141513 Littelfuse, Inc. 800 E. Northwest Hwy Desplaines IL 60016 Date : Dec 08, 2009 Sample Description: One (1) group of submitted samples said to be : Part Description : Epoxy Powder (HF Gold) Part Number : 087340 Date Sample Received : Dec 04, 2009 Date Test Started : Dec 04, 2009 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory. Page 1 Of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00141513 Test Conducted (Ⅰ) Test Result Summary : Testing Item Result (ppm) Submitted Samples Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Halogen Content Fluorine (F) Chlorine (Cl) Bromine (Br) Iodine (I) ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND 426 ND ND Remarks: ppm = Parts per million based on weight of tested sample = mg/kg ND = Not detected Responsibility Of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received Testing Period : Dec 04, 2009 : Dec 04, 2009 to Dec 08, 2009 Page 2 Of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00141513 Test Conducted (Ⅱ) RoHS Requirement: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr6+) Content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ehters (PBDEs) Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. (Ⅲ) Test Method: Testing Item Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) Halogen Content Testing Method Reporting Limit With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion 2 ppm until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion 2 ppm until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until 2 ppm the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 1 ppm in annex C, by alkaline digestion and determined by UV-Vis spectrophotometer. With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and 5 ppm determined by GC-MSD and further HPLC confirmation when necessary. With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and 5 ppm determined by GC-MSD and further HPLC confirmation when necessary. With reference to EN 14582:2007 by combustion flask with oxygen and determined by ion 50 ppm chromatography Remark: Reporting limit = Quantitation limit of analyte in sample Page 3 Of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00141513 Test Conducted (Ⅳ) Measurement Flowchart: Test For Cd/Pb/Hg/Chromium (VI)/PBBs/PBDEs Contents Reference Standard: IEC 62321 edition 1.0:2008 Page 4 Of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00141513 Test Conducted (Ⅳ) Measurement Flowchart: Test For Halogen Content Reference Standard: EN 14582 sampling/grinding or cutting add absorbent in a combustion flask & place weighed sample in equipment fill the combustion flask with oxygen ignite then leave the flask at room temperature transfer the absorbent into a volumetric flask make up with deionized water analyzed by ion chromatography End Of Report Page 5 Of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00141513 Test Conducted Photo Page 6 Of 6 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401