ICPTest_471L pdf

ICP Test Report Certification Packet
Company name :
Littelfuse, Inc.
Product Series:
Pico
Product #:
471xxxL Series
Issue Date:
March 4, 2010
It is hereby certified by Littelfuse, Inc. that there is neither RoHS (EU Directive
2002/95/EC)-restricted substance nor such use, for materials to be used for unit parts, for
packing/packaging materials, and for additives and the like in the manufacturing processes.
In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used
for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing
processes, are all composed of the following components.
Issued by:
<Global EHS Engineer>
(1) Parts, sub-materials and unit parts
This document covers the Pico RoHS-Compliant series products manufactured by
Littelfuse, Inc.
< Raw Materials Used
Please see Table 1
(2) The ICP data on all measurable substances
Please see appropriate pages as identifed in Table 1
Remarks:
Pb (lead) contained in the high temperature melting solder > 85% and is categorized as
exempt under section 7a of the RoHS Annex.
Form 585-047 Rev. A
1
2/21/06
Table 1: List of Raw Materials covered by this report
Total Parts
1
2
3
4
5
6
Raw Material Part Number
909-144
910-263
497xxx
082xxx
692320
087234
Raw Material Description
Body
Cap and Lead Assembly
Cu Clad Fe58 42Ni5Ag by weight Wire
99% Cu Wire
Solder
Pico Gold Powder
2
Page(s)
3-8
9-13
14-18
19-23
24-28
29-34
Test Report
Applicant:
Number : TWNC00141509
Littelfuse, Inc.
800 E. NORTHWEST HWY
DESPLAINES IL 60016
Date
: Dec 09, 2009
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: Body
Part Number
: 909-144
Date Sample Received
: Dec 04, 2009
Date Test Started
: Dec 04, 2009
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
This report shall not be reproduced
except in full, without the written
approval of the laboratory.
Page 1 Of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00141509
Test Conducted
(Ⅰ) Test Result Summary :
Testing Item
Result (ppm)
Grey Material
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content
Polybrominated Biphenyls (PBBs)
Monobrominated Biphenyls (MonoBB)
Dibrominated Biphenyls (DiBB)
Tribrominated Biphenyls (TriBB)
Tetrabrominated Biphenyls (TetraBB)
Pentabrominated Biphenyls (PentaBB)
Hexabrominated Biphenyls (HexaBB)
Heptabrominated Biphenyls (HeptaBB)
Octabrominated Biphenyls (OctaBB)
Nonabrominated Biphenyls (NonaBB)
Decabrominated Biphenyl (DecaBB)
Polybrominated Diphenyl Ethers (PBDEs)
Monobrominated Diphenyl Ethers (MonoBDE)
Dibrominated Diphenyl Ethers (DiBDE)
Tribrominated Diphenyl Ethers (TriBDE)
Tetrabrominated Diphenyl Ethers (TetraBDE)
Pentabrominated Diphenyl Ethers (PentaBDE)
Hexabrominated Diphenyl Ethers (HexaBDE)
Heptabrominated Diphenyl Ethers (HeptaBDE)
Octabrominated Diphenyl Ethers (OctaBDE)
Nonabrominated Diphenyl Ethers (NonaBDE)
Decabrominated Diphenyl Ether (DecaBDE)
Halogen Content
Fluorine (F)
Chlorine (Cl)
Bromine (Br)
Iodine (I)
ND
52
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
Remarks: ppm = Parts per million based on weight of tested sample = mg/kg
ND = Not detected
Responsibility Of Chemist : Irene Chiou / Kevin Liu / Cathy Chen
Date Sample Received
Testing Period
: Dec 04, 2009
: Dec 04, 2009 To Dec 08, 2009
Page 2 Of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00141509
Test Conducted
(Ⅱ) RoHS Requirement:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Polybrominated Biphenyls (PBBs)
Polybrominated Diphenyl Ehters (PBDEs)
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for
homogeneous material.
(Ⅲ) Test Method:
Testing Item
Cadmium (Cd)
content
Lead (Pb) content
Mercury (Hg)
content
Chromium VI (Cr6+)
content
Polybrominated
Biphenyls (PBBs)
Polybrominated
Diphenyl Ethers
(PBDEs)
Halogen Content
Testing Method
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 7, by microwave
digestion until the tested samples are
totally dissolved and determined by
ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in annex C, by alkaline
digestion and determined by UV-Vis
spectrophotometer.
With reference to IEC 62321 edition
1.0:2008 in annex A, by solvent
extraction and determined by GC-MSD
and further HPLC confirmation when
necessary.
With reference to IEC 62321 edition
1.0:2008 in annex A, by solvent
extraction and determined by GC-MSD
and further HPLC confirmation when
necessary.
With reference to EN 14582:2007 by
combustion flask with oxygen and
determined by ion chromatography
Reporting Limit
2 ppm
2 ppm
2 ppm
1 ppm
5 ppm
5 ppm
50 ppm
Remark: Reporting limit = Quantitation limit of analyte in sample
Page 3 Of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00141509
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Cd/Pb/Hg/Chromium (VI)/PBBs/PBDEs Contents
Reference Standard: IEC 62321 edition 1.0:2008
Page 4 Of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00141509
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Halogen Content
Reference Standard: EN 14582
sampling/grinding or
cutting
add absorbent in a
combustion flask &
place weighed sample in
equipment
fill the combustion
flask with oxygen
ignite then leave the
flask at room
temperature
transfer the absorbent
into a volumetric flask
make up with deionized
water
analyzed by ion
chromatography
End Of Report
Page 5 Of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00141509
Test Conducted
Photo
Page 6 Of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Test Report
Applicant:
Number : TWNC00132836
Littelfuse, Inc.
800 E. NORTHWEST HWY
DESPLAINES IL 60016
Date
: Sep 29, 2009
Sample Description:
One (1) group of submitted samples said to be :
Sample Description
: Cap/ Lead Assay
(A)Base meterial
(B)Plating
Style / Item No.
: 910-263
Date Sample Received
: Sep 23, 2009
Date Test Started
: Sep 24, 2009
Test Conducted:
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
This report shall not be reproduced
except in full, without the written
approval of the laboratory.
Page 1 Of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00132836
Test Conducted
(Ⅰ) Test Result Summary :
Testing Item
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content (mg/kg with 50cm2)
Result (ppm)
(A)
(B)
ND
ND
ND
Negative
(< 0.02)
ND
ND
ND
Negative
(< 0.02)
Remarks: ppm = Parts per million based on weight of tested sample = mg/kg
ND = Not detected
<
= Less than
mg/kg with 50cm2 = milligram per kilogram with 50 square centimetre
Negative = A negative test result indicated positive observation
was not found at the time of testing.
Responsibility Of Chemist : Irene Chiou / Kevin Liu / Cathy Chen
Date Sample Received
Testing Period
: Sep 23, 2009
: Sep 24, 2009 To Sep 28, 2009
(Ⅱ) RoHS Requirement:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for
homogeneous material.
Page 2 Of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00132836
Test Conducted
(Ⅲ) Test Method:
Testing Item
Cadmium (Cd)
content
Lead (Pb) content
Mercury (Hg)
content
Chromium VI (Cr6+)
content
Remark:
Testing Method
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 7, by microwave
digestion until the tested samples are
totally dissolved and determined by
ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in annex B, by boiling water
extraction and determined by UV-Vis
spectrophotometer.
Reporting Limit
2 ppm
2 ppm
2 ppm
0.02
mg/kg with 50cm2
Reporting limit = Quantitation limit of analyte in sample
Page 3 Of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00132836
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Cd/Pb/Hg/Chromium (VI)
Reference Standard:IEC 62321 edition 1.0:2008
End Of Report
Page 4 Of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00132836
Test Conducted
Photo
Page 5 Of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Test Report
Applicant:
Number : TWNC00139515
Littelfuse, Inc.
800 E. Northwest Hwy
Desplaines IL 60016
Date
: Nov 20, 2009
Sample Description:
One (1) group of submitted samples said to be :
Sample Description
: Element-CuClad Fe58 Ni Ag By weight (497xxx)
Style / Item No.
: 497226
Date Sample Received
: Nov 17, 2009
Date Test Started
: Nov 18, 2009
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
This report shall not be reproduced
except in full, without the written
approval of the laboratory.
Page 1 Of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00139515
Test Conducted
(Ⅰ) Test Result Summary :
Testing Item
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content (mg/kg with 50cm2)
Result (ppm)
Silvery Metal Wire
ND
ND
ND
Negative
(< 0.02)(#)
Remarks: ppm = parts per million based on weight of tested sample = mg/kg
ND = Not Detected
<
= Less Than
mg/kg with 50cm2 = milligram per kilogram with 50 square centimeter
Negative = A negative test result indicated positive observation
was not found at the time of testing. When the spot test
showed a negative result, the boiling water extraction
procedure shall be used to verify the result.
#
= Due to the insufficient sample area, reduced total sample
surface of 10 cm2 was used and the dilution factor was
adjusted accordingly.
Responsibility Of Chemist : Irene Chiou / Kevin Liu / Cathy Chen
Date Sample Received
Testing Period
: Nov 17, 2009
: Nov 18, 2009 to Nov 20, 2009
(Ⅱ) RoHS Requirement:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for
homogeneous material.
Page 2 Of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00139515
Test Conducted
(Ⅲ) Test Method:
Testing Item
Testing Method
With reference to IEC 62321
edition 1.0:2008 in clause
8/9/10, by microwave digestion
Cadmium (Cd) content
until the tested samples are
totally dissolved and determined
by ICP-OES.
With reference to IEC 62321
edition 1.0:2008 in clause
8/9/10, by microwave digestion
Lead (Pb) content
until the tested samples are
totally dissolved and determined
by ICP-OES.
With reference to IEC 62321
edition 1.0:2008 in clause 7, by
microwave digestion until the
Mercury (Hg) content
tested samples are totally
dissolved and determined by ICPOES.
With reference to IEC 62321
edition 1.0:2008 in annex B, by
Chromium VI (Cr6+) content boiling water extraction and
determined by UV-Vis
spectrophotometer.
Reporting Limit
2 ppm
2 ppm
2 ppm
0.02
mg/kg with 50cm2
Remark: Reporting Limit = Quantitation limit of analyte in sample
Page 3 Of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00139515
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Cd/Pb/Hg/Chromium (VI)
Reference Standard:IEC 62321 edition 1.0:2008
End Of Report
Page 4 Of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00139515
Test Conducted
Photo
Page 5 Of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Intertek Testing Services Ltd., Shanghai
TFH Division
Block B, Jinling Business Square,No.801 Yi Shan Road,
Shanghai, China, 200233
Tel: +86 21 6120 6565
Fax: +86 21 6127 9740
E-mail: [email protected]
www.intertek.com
www.intertek.com.cn
China Toll-Free: 800 999 1338
TEST REPORT
APPLICANT: LITTELFUSE,INC.
800 E. NORTHWEST HWY
ATTN: A.DIVIETRO/D.UNTIEDT
NUMBER: SHAH00176754
DATE: FEB 10, 2010
SAMPLE DESCRIPTION:
One (1) group of submitted samples said to be Coppery Wire.
Part Description
: Element.
Part Number
: 99% Cu 082xxx.
Date Sample Received
: Feb.3, 2010.
Date Test Started
: Feb.3, 2010.
***********************************************************************
TESTS CONDUCTED:
AS REQUESTED BY THE APPLICANT, FOR DETAILS REFER TO ATTACHED PAGE(S)
***********************************************************************
TO BE CONTINUED
PREPARED AND CHECKED BY:
FOR INTERTEK TESTING SERVICES
LTD., SHANGHAI
AUTHORIZED BY:
FOR INTERTEK TESTING SERVICES
LTD., SHANGHAI
MYRA LV
CHEMICAL DIVISION MANAGER
STEPHEN TSANG
GENERAL MANAGER
PAGE 1 OF 5
Intertek Testing Services Ltd., Shanghai
TFH Division
Block B, Jinling Business Square,No.801 Yi Shan Road,
Shanghai, China, 200233
Tel: +86 21 6120 6565
Fax: +86 21 6127 9740
E-mail: [email protected]
www.intertek.com
www.intertek.com.cn
China Toll-Free: 800 999 1338
TEST REPORT
NUMBER: SHAH00176754
TESTS CONDUCTED
(I) Test Result Summary :
Testing Item
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content (mg/kg with 50cm2)
Result (ppm)
ND
ND
ND
ND
Remarks: ppm = Parts per million = mg/kg
ND = Not detected
mg/kg with 50cm2 = milligram per kilogram with 50 square
centimetre
Responsibility Of Chemist : Dent Fang
(II) RoHS Requirement:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment
2005/618/EC for homogeneous material.
**********************************************************************
TO BE CONTINUED
PAGE 2 OF 5
Intertek Testing Services Ltd., Shanghai
TFH Division
Block B, Jinling Business Square,No.801 Yi Shan Road,
Shanghai, China, 200233
Tel: +86 21 6120 6565
Fax: +86 21 6127 9740
E-mail: [email protected]
www.intertek.com
www.intertek.com.cn
China Toll-Free: 800 999 1338
TEST REPORT
NUMBER: SHAH00176754
TESTS CONDUCTED
(III) Test Method:
Testing Item
Testing Method
Reporting Limit
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
Cadmium (Cd)
microwave digestion until the
2 ppm
content
tested samples are totally
dissolved and determined by ICPOES.
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the
Lead (Pb) content
2 ppm
tested samples are totally
dissolved and determined by ICPOES.
With reference to IEC 62321 edition
1.0:2008 in clause 7, by microwave
Mercury (Hg)
digestion until the tested samples
2 ppm
content
are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
0.02
Chromium VI (Cr6+) 1.0:2008 in annex B, by boiling
mg/kg with
content
water extraction and determined by
50cm2
UV-Vis spectrophotometer.
Remark: Reporting limit = Quantitation limit of analyte in sample
Date Sample Received : Feb.3, 2010
Testing Period : Feb.3, 2010 TO Feb.8, 2010
**********************************************************************
TO BE CONTINUED
PAGE 3 OF 5
Intertek Testing Services Ltd., Shanghai
TFH Division
Block B, Jinling Business Square,No.801 Yi Shan Road,
Shanghai, China, 200233
Tel: +86 21 6120 6565
Fax: +86 21 6127 9740
E-mail: [email protected]
www.intertek.com
www.intertek.com.cn
China Toll-Free: 800 999 1338
TEST REPORT
NUMBER: SHAH00176754
TESTS CONDUCTED
(IV) Measurement Flowchart:
Test For Cd/Pb/Hg/Chromium (VI)
Reference Standard:IEC 62321 edition 1.0:2008
**********************************************************************
TO BE CONTINUED
PAGE 4 OF 5
Intertek Testing Services Ltd., Shanghai
TFH Division
Block B, Jinling Business Square,No.801 Yi Shan Road,
Shanghai, China, 200233
Tel: +86 21 6120 6565
Fax: +86 21 6127 9740
E-mail: [email protected]
www.intertek.com
www.intertek.com.cn
China Toll-Free: 800 999 1338
TEST REPORT
NUMBER: SHAH00176754
TESTS CONDUCTED
*******************************************************************
END OF REPORT
PAGE 5 OF 5
Test Report
Applicant:
Number : TWNC00141510
Littelfuse, Inc.
800 E. Northwest Hwy
Desplaines IL 60016
Date
: Dec 09, 2009
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: Solder
Part Number
: 692320
Date Sample Received
: Dec 04, 2009
Date Test Started
: Dec 04, 2009
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
This report shall not be reproduced
except in full, without the written
approval of the laboratory.
Page 1 Of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00141510
Test Conducted
(Ⅰ) Test Result Summary :
Testing Item
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content (mg/kg with 50cm2)
Result (ppm)
Silvery Metal
ND
850739
ND
Negative (< 0.02)
Remarks: ppm = Parts per million based on weight of tested sample = mg/kg
ND = Not detected
<
= Less than
mg/kg with 50cm2 = milligram per kilogram with 50 square centimetre
Negative = A negative test result indicated positive observation
was not found at the time of testing.
Responsibility Of Chemist : Irene Chiou / Kevin Liu / Cathy Chen
Date Sample Received
Testing Period
: Dec 04, 2009
: Dec 04, 2009 to Dec 09, 2009
(Ⅱ) RoHS Requirement:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for
homogeneous material.
Page 2 Of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00141510
Test Conducted
(Ⅲ) Test Method:
Testing Item
Cadmium (Cd)
content
Lead (Pb) content
Mercury (Hg)
content
Chromium VI (Cr6+)
content
Testing Method
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 7, by microwave
digestion until the tested samples are
totally dissolved and determined by
ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in annex B, by boiling water
extraction and determined by UV-Vis
spectrophotometer.
Reporting Limit
2 ppm
2 ppm
2 ppm
0.02
mg/kg with 50cm2
Remark: Reporting limit = Quantitation limit of analyte in sample
Page 3 Of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00141510
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Cd/Pb/Hg/Chromium (VI)
Reference Standard:IEC 62321 edition 1.0:2008
End Of Report
Page 4 Of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00141510
Test Conducted
Photo
Page 5 Of 5
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Test Report
Applicant:
Number : TWNC00141512
Littelfuse, Inc.
800 E. Northwest Hwy
Desplaines IL 60016
Date
: Dec 08, 2009
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: Epoxy Powder (RoHS Gold)
Part Number
: 087234
Date Sample Received
: Dec 04, 2009
Date Test Started
: Dec 04, 2009
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
This report shall not be reproduced
except in full, without the written
approval of the laboratory.
Page 1 Of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00141512
Test Conducted
(Ⅰ) Test Result Summary :
Testing Item
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content
Polybrominated Biphenyls (PBBs)
Monobrominated Biphenyls (MonoBB)
Dibrominated Biphenyls (DiBB)
Tribrominated Biphenyls (TriBB)
Tetrabrominated Biphenyls (TetraBB)
Pentabrominated Biphenyls (PentaBB)
Hexabrominated Biphenyls (HexaBB)
Heptabrominated Biphenyls (HeptaBB)
Octabrominated Biphenyls (OctaBB)
Nonabrominated Biphenyls (NonaBB)
Decabrominated Biphenyl (DecaBB)
Polybrominated Diphenyl Ethers (PBDEs)
Monobrominated Diphenyl Ethers (MonoBDE)
Dibrominated Diphenyl Ethers (DiBDE)
Tribrominated Diphenyl Ethers (TriBDE)
Tetrabrominated Diphenyl Ethers (TetraBDE)
Pentabrominated Diphenyl Ethers (PentaBDE)
Hexabrominated Diphenyl Ethers (HexaBDE)
Heptabrominated Diphenyl Ethers (HeptaBDE)
Octabrominated Diphenyl Ethers (OctaBDE)
Nonabrominated Diphenyl Ethers (NonaBDE)
Decabrominated Diphenyl Ether (DecaBDE)
Halogen Content
Fluorine (F)
Chlorine (Cl)
Bromine (Br)
Iodine (I)
Result (ppm)
Submitted Samples
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
740
40464
ND
Remarks: ppm = Parts per million based on weight of tested sample = mg/kg
ND = Not detected
Responsibility Of Chemist : Irene Chiou / Kevin Liu / Cathy Chen
Date Sample Received
Testing Period
: Dec 04, 2009
: Dec 04, 2009 to Dec 08, 2009
Page 2 Of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00141512
Test Conducted
(Ⅱ) RoHS Requirement:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Polybrominated Biphenyls (PBBs)
Polybrominated Diphenyl Ehters (PBDEs)
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for
homogeneous material.
(Ⅲ) Test Method:
Testing Item
Cadmium (Cd)
content
Lead (Pb)
content
Mercury (Hg)
content
Chromium VI
(Cr6+) content
Polybrominated
Biphenyls
(PBBs)
Polybrominated
Diphenyl
Ethers (PBDEs)
Halogen
Content
Testing Method
Reporting Limit
With reference to IEC 62321 edition 1.0:2008
in clause 8/9/10, by microwave digestion
2 ppm
until the tested samples are totally
dissolved and determined by ICP-OES.
With reference to IEC 62321 edition 1.0:2008
in clause 8/9/10, by microwave digestion
2 ppm
until the tested samples are totally
dissolved and determined by ICP-OES.
With reference to IEC 62321 edition 1.0:2008
in clause 7, by microwave digestion until
2 ppm
the tested samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition 1.0:2008
1 ppm
in annex C, by alkaline digestion and
determined by UV-Vis spectrophotometer.
With reference to IEC 62321 edition 1.0:2008
in annex A, by solvent extraction and
5 ppm
determined by GC-MSD and further HPLC
confirmation when necessary.
With reference to IEC 62321 edition 1.0:2008
in annex A, by solvent extraction and
5 ppm
determined by GC-MSD and further HPLC
confirmation when necessary.
With reference to EN 14582:2007 by combustion
flask with oxygen and determined by ion
50 ppm
chromatography
Remark: Reporting limit = Quantitation limit of analyte in sample
Page 3 Of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00141512
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Cd/Pb/Hg/Chromium (VI)/PBBs/PBDEs Contents
Reference Standard: IEC 62321 edition 1.0:2008
Page 4 Of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00141512
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Halogen Content
Reference Standard: EN 14582
sampling/grinding or
cutting
add absorbent in a
combustion flask &
place weighed sample in
equipment
fill the combustion
flask with oxygen
ignite then leave the
flask at room
temperature
transfer the absorbent
into a volumetric flask
make up with deionized
water
analyzed by ion
chromatography
End Of Report
Page 5 Of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Number : TWNC00141512
Test Conducted
Photo
Page 6 Of 6
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401