23203B

23203B
0.167
[4,25]
0.354
[9,00]
Wide Input Voltage
Biaxial Accelerometer
0.099
[2,51]
0.323
[8,20]
0.128
[3,25]
Dimensions in inches [mm]
0.354
[9,00]
0.542
[13,75]
1.437
[36,50]
0.354
[9,00]
1 2 3 4 5 6 7 8 9
0.575
[14,60]
1
2
2
1.180
[29,97]
Rear View
6 7 8 9
0.240
[6,10]
1
0.689
[17,50]
Terminal Block
Spring and cable
added with
Option T001
0.147 [3,73] Thru
(2) Places
1.000
[25,40]
Bottom View
Mounting Instructions
Use two 3,0 x 0,5 mm thread machine screws to attach to the
bottom or rear 23203B mount faces. Be careful not to bottom
screws in tapped holes as this can strip threads. Alternatively, the
two thru holes allow two #6 or two 3,5 mm screws to be used to
mount the 23203B from the top.
➤ A light film of oil or silicone grease can be used to enhance
contact between mounting surfaces.
➤ A locking compound should be used on all threads to prevent
screws loosening due to vibrations.
➤
INSTRUMENTS
Summit Instruments, Inc.
2 2 3 6 N . C l eve l a n d - M a s s i l l o n R d .
A k ro n , O h i o 4 4 3 3 3 - 1 2 5 5 U S A
( 3 3 0 ) 6 5 9 - 3 3 1 2 FA X : ( 3 3 0 ) 6 5 9 - 3 2 8 6
How to Use the 23203B
Connect a +8 to +30V DC power source to pins 8 and 9.
Connect a differential or floating input A/D converter to each
signal and signal common pins (pins 5 and 6 for Accelerometer 1,
pins 1 and 2 for Accelerometer 2, and pins 3 and 2 for
Temperature). For best results use a converter with an input
impedance greater than 1MΩ and common mode rejection ratio
greater than 60dB. Single-ended converters are not
recommended but if used, leave Signal Common unconnected to
eliminate ground loops. A positive acceleration (labeled on the
accelerometer cover) causes a positive change on the
corresponding output.
➤ Keep cable lengths between the accelerometer and A/D converter
as short as practical. Use shielded twisted pair wiring, especially
near electric motors or other noise sources.
➤ As a rule of thumb, sample frequency should be at least 10 times
the signal bandwidth when linear interpolation is used for signal
reconstruction. Built-in or external low-pass filtering can be used
to lower the noise floor and eliminate spurious peak
measurements from short-duration shock impulses with
insignificant energy content.
➤ A logic 1 on the self-test input will add 0.1 to 0.5V* to both
accelerometer outputs. An output that changes less than +0.1V*
or more than +0.5V* indicates a defective channel, shorted pin,
or broken wire. The self-test signal is approximate and should not
be used for calibration. If the self-test feature will not be used, pin
7 should be connected to pin 9.
➤
➤
* Scale linearly with range option Rnnn.
Male D-Shell
Connector
Accelerometer Connections
Pin
SUMMIT
1 2 3 4 5
3 mm x 0,5 mm Thread
0.138 [3,50] Deep
(4) Places
Specifications*
Min Typical Max
Range
Measurement Full Scale
Shock survival, powered
Shock survival, unpowered
Sensitivity
At 25° C, ±5 g FSR
Drift TMIN to TMAX
Zero G Bias Level
At 25° C
Drift TMIN to TMAX
Alignment Deviation from ideal
Transverse Sensitivity
Nonlinearity
Upper Cutoff Frequency
Noise Density
Self Test Input Impedance
Temperature Sensor
Sensitivity
+25°C Bias Level
Power Supply (VS )
Input voltage
Input current
DC rejection ratio
Outputs
Output voltage swing
Capacitive drive capability
Temperature Range
* Data subject to change without notice.
±1
-500
-1000
±5
+500
+1000
450
±0.5
3.125
±0.2
±2.0
0.25
0.2
4.6
30
0.225
50
±3.0
10,000
0.325
8
2.4
2.6
+8
80
0.05
1000
-40
†
6
120
g
g
g
mV/g
%
†
1.875
Units
V
g
degrees
%
% FSR
Hz
mg/√Hz
kΩ
mV/°K
V
+30
9
V
mA
dB
4.95
V
pF
°C
+85
Scale linearly with range option Rnnn.
1
2
3
4
5
6
7
8
9
Description
Cable Wire
Accelerometer 2
Signal Common
Temperature
+5V Output
Accelerometer 1
Signal Common
Self Test
Power
Ground
Brown
Red
Orange
Yellow
Green
Blue
Violet
Grey
White*
}twisted pair
}twisted pair
}twisted pair
}twisted pair
* connected to braided shield at D-Shell Pin
Three - Year Limited Warranty
Summit Instruments, Inc. (SI) warrants this product against
defects in materials and workmanship for a period of three years from
date of shipment. During the warranty period, SI will, at its option,
either repair or replace products which prove to be defective.
Exclusions
This warranty does not apply to defects or damage resulting from:
• Improper installation or maintenance.
• Customer supplied software or interfacing.
• Unauthorized modification or misuse.
• Operation outside of the product specifications.
Limitations
The warranty set forth above is exclusive and no other warranty,
whether written or oral, is expressed or implied. Summit
Instruments specifically disclaims the implied warranties of
merchantability and fitness for a particular purpose.
Some jurisdictions do not allow limitations on how long an implied
warranty lasts, so the above limitation or exclusion may not apply
to you. However, any implied warranty of merchantability or
fitness is limited to the one-year duration of this written warranty.
Warranty Service
To obtain service during the warranty period products must be
returned, transportation prepaid, to SI.
23203B-D001 Rev. 06/05