XL403A

XL403A
Specifications*
±1 g to ±15g Rugged
Uniaxial, Biaxial,
or Triaxial Accelerometer
for Quick Shipment
Measurement Specialties, Inc.
2236 N. Cleveland-Massillon Rd.
Akron, Ohio 44333-1255 USA
(330) 659-3312 www.meas-spec.com
precisionsensors.meas-spec.com
Parameter
Min
Typical
Max
Units
Range
Measurement Full Scale
±1
±13
g
Sensitivity
At 25°C, Option R005
400†
mV/g
Drift Tmin to Tmax
±0.65
±3
%
Zero g Bias Level
At 25°C
2.5
V
Drift Tmin to Tmax
20
mg
Alignment
Deviation from Ideal Axes
±1.0
±3.0
degrees
Transverse Sensitivity
±0.25
%
Nonlinearity
0.1
0.5
% FSR
Frequency Response, 5-pole
0
800
Hz
Noise Density
100
µg/√Hz
Self-Test Pull-up Resistor
5
kΩ
Temperature Sensor
Sensitivity
6.45
mV/°C
0°C Bias Level
509
mV
Outputs
Output Voltage Swing
0.05
4.95
V
Capacitive Drive Capability
1000
pF
Power Supply (Vs)
Input Voltage Limits
-80
+80
V
Input Voltage - Operating
+8.5
+36
V
Input Current
12
mA
Rejection Ratio
>120
dB
Temperature Range (Ta)
-40
+85
°C
Mass
38
grams
Shock Survival
-5000
+5000
g
Data subject to change without notice
*within one year of calibration
†Scale linearly with range option Rnnn; see Ordering Information
Three-Year Limited Warranty
Measurement Specialties warrants this product against defects in
materials and workmanship for a period of three years from date of
shipment. During the warranty period, Measurement Specialties will, at
its option, either repair or replace products which prove to be defective.
Exclusions
This warranty does not apply to defects or damage resulting from:
•Improper installation or maintenance
•Customer supplied software or interfacing
•Unauthorized modification or misuse
•Operation outside of the product specifications
Limitations
The warranty set forth above is exclusive and no other warranty,
whether written or oral, is expressed or implied. Measurement
Specialties specifically disclaims the implied warranties of
merchantability and fitness for a particular purpose.
Some jurisdictions do not allow limitations on how long an implied
warranty lasts, so the above limitation or exclusion may not apply to
you. However, any implied warranty of merchantability or fitness is
limited to the three-year duration of this written warranty.
Warranty Service
To obtain service during the warranty period, products must be returned,
transportation prepaid, to Measurement Specialties.
XL403A Rev. 7/25/13
How to Use the XL403A
►Connect
►
a +8.5 to +36 V DC power source to pin 8, ground
to pin 9.
T004
Male D-Shell
Connector
3
Accelerometer Connections
3
Mounting Instructions
►Use
►
two 3.0 mm x 0.5 mm thread machine screws to attach
to one of the three XL403A mounting faces [recommended
torque 5 lbf-in (0.56 N.m)]. DO NOT thread a screw more
than 2.5 mm (0.100 inch or 5 turns) into any XL403A
mounting face as this can damage the accelerometer and will
VOID the warranty.
►A
► light film of oil or silicone grease can be used to enhance
contact between two mounting surfaces.
►A
► locking compound should be used on all threads to prevent
screws loosening due to vibrations.
Pin
Description
1
2
3
4
5
6
7
8
9
Accelerometer 1 Brown
Accelerometer 2 Red
Accelerometer 3 Orange
Signal -
Yellow
Reserved
Green
Reserved
Blue
Self Test
Violet
+Vs
Grey
Ground*
White
Cable Wire
}
}
}
}
twisted pair
twisted pair
twisted pair
twisted pair
*connected to braided shield at D-shell pin
CAUTION
Improper wiring, particularly Power, may cause
permanent damage and void the warranty.
Pins other than +Vs should not exceed 5 V
►Connect
►
a differential or floating input A/D converter to each
signal and signal common pins (pins 1 and 4 for Accelerometer
1, pins 2 and 4 for Accelerometer 2, and pins 3 and 4 for
Accelerometer 3). For best results, use a converter with
an input impedance greater than 1 MΩ and common mode
rejection ratio greater than 60 dB. Single-ended converters
are not recommended, but if used, leave pin 4 unconnected
to eliminate ground loops. A positive acceleration (marked
on the accelerometer label) causes a positive change on the
corresponding output.
►Keep
►
cable lengths between the accelerometer and A/D
converter as short as practical. Use shielded twisted pair
wiring, especially near electric motors or other noise sources.
►As
► a rule of thumb, sample frequency should be at least
10 times the signal bandwidth when linear interpolation is
used for signal reconstruction. Built-in or external low-pass
filtering can be used to lower the noise floor and eliminate
spurious peak measurements from short-duration shock
impulses with insignificant energy content.
►A
► logic 0 on the self-test input will add to all three accelerometer outputs (see calibration certificate for amount). An
output that changes significantly more or less (±20%) than
the certificate amount indicates a defective channel, shorted
pin or broken wire. The self-test signal is approximate and
should not be used for calibration. If the self-test feature will
not be used, pin 7 may be left disconnected.