Load cell DLRP L002 Features • Passive load cell 0...10 kN • Compact dimensions • For tension and compression • Protection class IP 67 • Stainless steel Order Code Technical Data Standard capacities 0...500 N 0...1000 N 0...2000 N 0...5000 N 0...10000 N Sensitivity at FS 2 mV/V Combined error Linearity Hysteresis < 0,3% FS < 0,3% FS < 0,3% FS DLRP L002. CL10 10 m (5 m standard) Load transmission TC Tension/Compression (see drawing) Measuring range 150 0...500 N 210 0...1000 N 220 0...2000 N 250 0...5000 N 310 0...10000 N Combined error B 0,3% < ±0,02% /K Temperature effect span < ±0,03% /K Zero balance Connection < ±1% FS S80 4-pin connector series 712 W24 Cable, 4-wire, open cable end Non-repeatability < 0,1% FS Creep error < 0,15% FS (after 30 min. with FS) Sensitivity tolerance < ±1% FS Bridge resistance Full bridge 350 Ω Isolation resistance > 3 GΩ Excitation max. 7V Signal polarity bipolar (tension +2 mV/V) – static load – dynamic load Breaking load 200% FS 100% FS 320% FS Deflection FS 0,05 mm typical Protection class IP 67 Cable 5 m, shielded, PUR Load cell material 1.4542 FS = Full scale output Combined error contains linearity, hysteresis and non-repeatability 2.8 TC/CL10 cable length Compensated 0...+70 ˚C temperature range Operating temperature -20...+70 ˚C range Storage temperature range -40...+85 ˚C Temperature effect zero .B www.baumer.com DLRP L002 Dimensions (mm) + SR40 - SR40 27 M10 Connector S35A, 4-pin 9 2 9 27 50,7 50,7 M10 62,5 ø ø ø ø ø M5 x 6M5 / 8x(4x) 6 / 8 (4x) 45° 45° 62,5 4 fixing screws M5, strength class 10.9 Installation torque 9 Nm 40 47 40 55 47 ø 55 Electrical Connection S80 W24 3 2 4 1 Bridge Circuit EXC.+ brown black blue white SIG.+ Pin Color Signal +VS 1 +VS brown 2 -VOUT black -VOUT 3 +VOUT blue GND 4 GND white Housing +VOUT SIG.- EXC.- Housing Wiring DLRP Transducer Precision amplifier/ power supply unit +V S +VOut -VOut Stabilized operating voltage Gain + - Zero GND RL: >10 MΩ VS: 5 - 24 VDC www.baumer.com 2.9