Load cell DLRP L001 Features • Passive load cell 0...10 kN • Compact dimensions • For compression • Protection class IP 67 • Stainless steel Order Code Technical Data Standard capacities 0...5000 N 0...10000 N Sensitivity at FS 1 mV/V Combined error Linearity Hysteresis < 0,5% FS < 0,5% FS < 0,5% FS DLRP L001. CL05 5 m cable length CL10 10 m cable length Load transmission CO Compression (see drawing) Measuring range 250 0...5000 N 310 0...10000 N < ±0,06% /K Combined error C 0,5% Temperature effect span < ±0,05% /K Zero balance < ±1% FS Non-repeatability < 0,1% FS Creep error < 0,2% FS (after 30 min. with FS) Sensitivity tolerance < ±1% FS Bridge resistance Full bridge 350 Ω Isolation resistance > 3 GΩ Excitation max. 7V Signal polarity unipolar (compression +1mV/V) – static load – dynamic load Breaking load 150% FS 100% FS 220% FS Deflection FS 0,05 mm typical Protection class IP 67 Cable 2 m, shielded, PUR Load cell material 1.4542 Connection FS = Full scale output Combined error contains linearity, hysteresis and non-repeatability 2.4 CO/ Optional cable length (2 m standard) Compensated 0...+70 ˚C temperature range Operating temperature -20...+70 ˚C range Storage temperature range -40...+85 ˚C Temperature effect zero .C www.baumer.com S80 4-pin connector series 712 W24 Cable, 4-wire, open cable end DLRP L001 Dimensions (mm) + ø 8 SR40 2 5,5 14 17 Connector S35A, 4-pin ø 32 h8 40 Electrical Connection S80 W24 3 2 4 1 Bridge Circuit EXC.+ brown black blue white SIG.+ Pin Color Signal +VS 1 +VS brown 2 -VOUT black -VOUT 3 +VOUT blue GND 4 GND white Housing +VOUT SIG.- EXC.- Housing Wiring DLRP Transducer Precision amplifier/ power supply unit +V S +VOut -VOut Stabilized operating voltage Gain + - Zero GND RL: >10 MΩ VS: 5 - 24 VDC www.baumer.com 2.5