VISTA-128FB/V128FB-24 COMMERCIAL FIRE AND PARTITIONED ALARM PLATFORM Designed to integrate seamlessly with CCTV, access A diverse line of Honeywell initiating devices, notification control and Honeywell’s full range of fire and burglary circuits, digital dialers, keypads, RF receivers and relays components, the VISTA-128FB provides the ultimate support this extremely powerful control platform. protection of life and property. The UL listed Commercial The VISTA-128FB has been designed to mount quickly Fire and Burglary Control Platform controls up to eight and easily in an attack resistant cabinet and is available in partitions and supports up to 128 zones/points using 12V and 24V models. hardwired, wireless and addressable V-Plex® technologies. FEATURES • Supports addressable V-Plex access control points using VistaKey (1 to 8 doors) • Supports up to 15 doors of access control using Vista Gateway Module (VGM)* • Supports CCTV applications with the new VistaView-100 CCTV switcher module • Identifies the point or zone of a fire or alarm, using the new FSA-8/ FSA-24 Fire system annunciator • Stores up to 512 events and can accommodate 150 user codes • Can control eight separate areas independently (8 partitions) • New E2 software simplifies programming • Two on-board notification (bell) circuits delivering 2.3A @ 12V or 3.4 amp @ 24V • Easily programmed and maintained with newly upgraded Compass Downloader software • Eight hardwired zones standard, expandableto 120 V-Plex addressable points/zones or 128 wireless points/zones • Automatic smoke detector sensitivity maintenance testing * Connects to Honeywell’s Passpoint Access Control Systems. Maximum 32 doors. VISTA-128FB/V128FB-24 COMMERCIAL FIRE AND PARTITIONED ALARM PLATFORM SPECIFICATIONS: • Cabinet dimensions - 18"H X 14.5"W X 4.3"D • Environmental - Storage temp: -14°F to 158°F (-10°C to 70°C) - Operating temp: -32°F to 122°F (0°C to 50°C) - Humidity: 85% RH • EMI Meets or exceeds the following requirements: - FCC Part 15, Class B Device - FCC Part 68 - IEC EMC Directive • Agency Listings Burglary - UL609 Grade A Local Mercantile Premises and - Mercantile Safe and Vault - UL611/1610 Grades A, AA, Central Station - UL365 Grades A, AA Police Connect • Fire - UL864 FPA72 Local, Central Station and Remote Station - Factory Mutual - California State Fire Marshal - MEA - UL985 • Additional Features - Notification Appliance Circuits (two) - Programmable - Temporal code compliant - Individually silenceable - Programmable on-board auxiliary relay - SIA false alarm reduction features: - Exit Error Logic - Exit Delay Reset - Cross Zoning - Call Waiting Defeat - Recent Close Report - Supports commercial hardwired, addressable V-Plex polling loop and wireless zones - Hardwired zones: - Provides nine style B hardwired zones - EOLR supervised for Fire and UL burglary installations - Supports N.0 or N.C. sensors - Individually assignable to one or all eight partitions - Up to 16 two-wire smoke detectors each zone 1 and 2 (32 total) - Up to 50 two-wire glass break detectors on zone eight - Patented addressable V-Plex polling loopV-Plex technology: - Supports up to 120 two-wire zones/points - Global polling technology for faster processing - Increased current draw capacit (128mA) - Supervised by panel - Individually assignable to partitions, notification circuit (bell) output or aux relay - 4,000 ft capability without the use of shielded cable - Extender/Isolation bus module - Two-wire smoke detector zone/group expansion module adds two or four zones - Eight zone - Class A and B Extender Module - One zone supervised Contact Monitor Module - UL Listed wireless expansion - Supports up to 128 wireless zones using 5881 Receiver - Supervised by control for checkin signals VPlex Loop 9500SN Glassbreak Sensor 4101SN Relay Module 4208U Eight-Zone Expansion Module 4293SN V-Plex Adapter 4208SNF Eight-Zone Expansion Module With Two Class A Zones 5881ENHC Wireless Commercial Receiver 5192 Series Smoke Detectors V-PLEX Loop 6160CR Custom Alpha Console VistaView-100 CCTV Switcher VistaKey V-Plex Access Control Module NAC (Bell) Circuit 4204CF 4204 Relay Module Notification Appliances } Eight Class B Hardware Zones 4146 Key Switch Option 5140 LED Communicator Status Module 4100SM Printer Interface Module RS232 Notification Appliances 6220S Printer Phone Line to Central Station 7720ULF Long Range Radio 7845C Cellular 4278EX EC VISTA-128FB/V128FB-24 COMMERCIAL FIRE AND PARTITIONED ALARM PLATFORM SPECIFICATIONS: - Tamper protection for transmitter - Individually assignable up to eight partitions - Supports UL864 FPA approved wireless smoke\ndetectors - Access control integration - Full integration with PassPoint - Access Control System Complete Gateway in access functions - Event reporting - Local printer of access or VISTA related event - Scheduled uploading of events to central station - Stored events for one call retrieval - Communication - Phone mapping by zone response type - Supports VIP Interactive Phone Voice Module - Panel operation during download - Uploading equipment list to central station - Communication to PassPoint via Vista Gateway Module (VGM) • Applications Supported by a diverse line of Honeywell initiating devices, the powerful VISTA-128FB is the ideal integrated fire and burglary control for applications where a higher level of security is necessary including medical and professional buildings, supermarkets, churches and synagogues, office buildings, schools, universities, strip malls, larger residences and factory or warehouse environments. Manual Pull Stations 5140MPS - 1* 5140MPS - 2* Quad PIR CP Bus 4193SN Serial Interface Module Q2260SN Multiplex DUAL TEC® Motion Detector 4190SN V-Plex Two-Zone Expander 4944SN Addressable Recessed Mount Contact Tamper Switch* Flow Switch* Low Temp Switch* 5881 Wireless Receiver (Max Two) 5808W3 Smoke Detectors 6139R 32 Character Red-Alpha Keypad 5890 Wireless PIR 5800 Series Wireless Devices 4204CF Supervised NAC Module 5816 Door/Window Miniature Transmitter 4209U Group Zoning Module 5808W3 Smoke Detectors Supports Up To 16 Conventional Two-Wire Smoke Detectors Notification Appliance 5869 Commercial Hold-Up Switch Supports Up To 64 Conventional Two-Wire Smoke Detectors 5817CB Wireless Commercial Transmitter • Installation The VISTA-128FB alarm system has been designed to mount both quickly and easily in an attack resistant cabinet. It meets all applicable requirements for UL commercial burglary installations. • Electrical: - Primary power: - 18 VAC@ 72 VA No. 1450 - Quiescent current draw: - 350mA - Backup battery - 12VDC, 12AH min to 34AAH max - Lead acid battery (gel type) - Alarm power - 12VDC, 1.7A max for each notification (bell) circuit output - Aux. standby power - 12VDC, 1A max - Total power - 2.3A at 12VDC, 3.4A at 24VDC from all sources - Standby time - 24 hours with 1A standby load or 60 hours with 205mA max standby load using 34AAH battery - Fusing - Battery input, aux. and notification (bell) circuit outputs are protected using PTC circuit protectors. All outputs are power limited. - Main dialer - Line seize: - Double Pole • Ringer equiv. - 0.713 VGM (PTVGM) Vista Gateway Module PassPoint • Formats - ADEMCO Low Speed, ADEMCO 4+2 Express, ADEMCO High Speed, ADEMCO Contact ID, Sescoa and Radionics VISTA-128FB/V128FB-24 COMMERCIAL FIRE AND PARTITIONED ALARM PLATFORM SPECIFICATIONS: • Auxiliary devices - 6160CR Alpha Keypad Commercial Fire - 6139R - Red Alpha Keypad/Annunciator - FSA-8 & FSA-24 Fire System Annunciator - 4204 - Relay Module, four form C contacts - 4204CF - Two supervised output circuits - 6220S - System printer used with 4100SM Serial Interface Module - 5140DLM, FSA-8, FSA-24, FSAKSM Fire Annunciator - 4209U Group Zoning Module two/four zones - 4293SN One Zone Serial Interface Module - 4297 Isolation/Extender Module • Two-wire and four-wire smoke detectors conventional - System Sensor smoke detectors • V-Plex (addressable) contacts - 4939SN-WH - 4944SN-WH - 4959SN • Horn/Strobes - System Sensor notification appliances • Manual pull stations - 5140MPS-1 - 5140MPS-2 • V-Plex (addressable) devices - 4101SN Single Relay/Zone Module - 4190SN Remote Point Module two zones - 4190WH Two Point Multiplex RPM - 4193SN Two Zone Serial Interface Module - 4208U Loop Expansion Module eight zones - 4208SNF Class A/13 Expander Module • V-Plex (addressable) smoke detectors - 5192SD - 5192SDT • Passive infrared detectors - 998MX - 4275EX-SN - 4278EX-SN - Quest 2260SN • Glassbreak detectors - 9500SN • VISTA Interactive Phone Module - 4286 Voice Module • Optional 24V power supply - PS24 - 24V power supply - 3.4A • Long range radio - Long range radio 7720ULF-XX, 7845C, 7835CFPK • Upgraded software - Upgraded Compass Downloader Windows compatible ORDERING VISTA-128FB Commercial Fire and Partitioned Burglary Alarm Platform 12V Model V128FB-24 Commercial Fire and Partitioned Burglary Alarm Platform 24V Model For more information: www.honeywell.com/security/hsc Automation and Control Solutions Honeywell Security & Communications 2 Corporate Center Dr. Suite 100 Melville, NY 11747 1.800.467.5875 www.honeywell.com L/VIS128FB/D May 2009 © 2009 Honeywell International Inc. • Wireless devices - 5804 - Wireless Key - 5804BD - Bi-Directional Key - 5804BDV - Bi-Directional with voice - 5816 - Door/Window Transmitter - 5819 - Shock Sensor - 5827BD - Bi-Directional Keypad - 5849 - Glassbreak Detector - 5881 Series - RF Receiver supporting 5800 wireless detectors - 5890 - PIR • Access control - VistaKey V-Plex (addressable) Access Control - VistaKey-SK Starter Kit - VistaKey-EX Expansion Kit - VGM Vista Gateway Module to PassPoint Access Control (Honeywell Access Systems) • CCTV - VistaView-100-CCTV Switch Module • Commercial wireless devices - 5869 - Hold up Transmitter - 5817CB - Wireless Commercial Transmitter - 5881ENHC - Commercial Fire/Burg Receiver - 5808W3 - Wireless Smoke Detector - 5809 - Wireless Heat Detector