VISTA-128FB V128FB-24 Data Sheet

VISTA-128FB/V128FB-24
COMMERCIAL FIRE AND
PARTITIONED ALARM PLATFORM
Designed to integrate seamlessly with CCTV, access
A diverse line of Honeywell initiating devices, notification
control and Honeywell’s full range of fire and burglary
circuits, digital dialers, keypads, RF receivers and relays
components, the VISTA-128FB provides the ultimate
support this extremely powerful control platform.
protection of life and property. The UL listed Commercial
The VISTA-128FB has been designed to mount quickly
Fire and Burglary Control Platform controls up to eight
and easily in an attack resistant cabinet and is available in
partitions and supports up to 128 zones/points using
12V and 24V models.
hardwired, wireless and addressable V-Plex® technologies.
FEATURES
• Supports addressable V-Plex
access control points using
VistaKey (1 to 8 doors)
• Supports up to 15 doors of
access control using Vista
Gateway Module (VGM)*
• Supports CCTV applications with
the new VistaView-100 CCTV
switcher module
• Identifies the point or zone of a fire
or alarm, using the new FSA-8/
FSA-24 Fire system annunciator
• Stores up to 512 events and can
accommodate 150 user codes
• Can control eight separate areas
independently (8 partitions)
• New E2 software simplifies
programming
• Two on-board notification (bell)
circuits delivering 2.3A @ 12V or
3.4 amp @ 24V
• Easily programmed and maintained
with newly upgraded Compass
Downloader software
• Eight hardwired zones standard,
expandableto 120 V-Plex
addressable points/zones or 128
wireless points/zones
• Automatic smoke detector
sensitivity maintenance testing
* Connects to Honeywell’s Passpoint Access
Control Systems. Maximum 32 doors.
VISTA-128FB/V128FB-24
COMMERCIAL FIRE AND PARTITIONED ALARM PLATFORM
SPECIFICATIONS:
• Cabinet dimensions
- 18"H X 14.5"W X 4.3"D
• Environmental
- Storage temp: -14°F to 158°F
(-10°C to 70°C)
- Operating temp: -32°F to 122°F
(0°C to 50°C)
- Humidity: 85% RH
• EMI
Meets or exceeds the following
requirements:
- FCC Part 15, Class B Device
- FCC Part 68
- IEC EMC Directive
• Agency Listings
Burglary
- UL609 Grade A Local Mercantile
Premises and
- Mercantile Safe and Vault
- UL611/1610 Grades A, AA,
Central Station
- UL365 Grades A, AA Police
Connect
• Fire
- UL864 FPA72 Local, Central
Station and Remote Station
- Factory Mutual
- California State Fire Marshal
- MEA
- UL985
• Additional Features
- Notification Appliance Circuits (two)
- Programmable
- Temporal code compliant
- Individually silenceable
- Programmable on-board
auxiliary relay
- SIA false alarm reduction
features:
- Exit Error Logic
- Exit Delay Reset
- Cross Zoning
- Call Waiting Defeat
- Recent Close Report
- Supports commercial hardwired,
addressable V-Plex polling loop and
wireless zones
- Hardwired zones:
- Provides nine style B hardwired
zones
- EOLR supervised for Fire and
UL burglary installations
- Supports N.0 or N.C. sensors
- Individually assignable to one
or all eight partitions
- Up to 16 two-wire smoke
detectors each zone 1 and 2
(32 total)
- Up to 50 two-wire glass break
detectors on zone eight
- Patented addressable V-Plex
polling loopV-Plex technology:
- Supports up to 120 two-wire
zones/points
- Global polling technology for
faster processing
- Increased current draw
capacit (128mA)
- Supervised by panel
- Individually assignable to
partitions, notification circuit
(bell) output or aux relay
- 4,000 ft capability without the
use of shielded cable
- Extender/Isolation bus module
- Two-wire smoke detector
zone/group expansion module
adds two or four zones
- Eight zone - Class A and B
Extender Module
- One zone supervised Contact
Monitor Module
- UL Listed wireless expansion
- Supports up to 128
wireless zones using 5881
Receiver
- Supervised by control for checkin signals
VPlex Loop
9500SN
Glassbreak Sensor
4101SN
Relay Module
4208U
Eight-Zone
Expansion
Module
4293SN
V-Plex Adapter
4208SNF
Eight-Zone
Expansion
Module
With Two Class A
Zones
5881ENHC
Wireless
Commercial
Receiver
5192 Series
Smoke
Detectors
V-PLEX Loop
6160CR
Custom Alpha
Console
VistaView-100
CCTV
Switcher
VistaKey V-Plex
Access Control
Module
NAC (Bell) Circuit
4204CF
4204
Relay
Module
Notification Appliances
}
Eight Class B Hardware Zones
4146
Key
Switch
Option
5140 LED
Communicator
Status Module
4100SM
Printer
Interface
Module
RS232
Notification Appliances
6220S Printer
Phone Line to Central Station
7720ULF Long
Range Radio
7845C Cellular
4278EX
EC
VISTA-128FB/V128FB-24
COMMERCIAL FIRE AND PARTITIONED ALARM PLATFORM
SPECIFICATIONS:
- Tamper protection for transmitter
- Individually assignable up to eight
partitions
- Supports UL864 FPA approved
wireless smoke\ndetectors
- Access control integration
- Full integration with PassPoint
- Access Control System Complete
Gateway in access functions
- Event reporting
- Local printer of access or VISTA
related event
- Scheduled uploading of events to
central station
- Stored events for one call retrieval
- Communication
- Phone mapping by zone
response type
- Supports VIP Interactive Phone
Voice Module
- Panel operation during
download
- Uploading equipment list to
central station
- Communication to PassPoint
via Vista Gateway Module (VGM)
• Applications
Supported by a diverse line of
Honeywell initiating devices, the
powerful VISTA-128FB is the ideal
integrated fire and burglary control for
applications where a higher level of
security is necessary including
medical and professional buildings,
supermarkets, churches and
synagogues, office buildings, schools,
universities, strip malls, larger
residences and factory or warehouse
environments.
Manual Pull Stations
5140MPS - 1*
5140MPS - 2*
Quad PIR
CP Bus
4193SN
Serial Interface
Module
Q2260SN Multiplex
DUAL TEC® Motion Detector
4190SN
V-Plex Two-Zone
Expander
4944SN
Addressable
Recessed Mount
Contact
Tamper Switch*
Flow Switch*
Low Temp Switch*
5881
Wireless Receiver
(Max Two)
5808W3
Smoke
Detectors
6139R
32 Character
Red-Alpha
Keypad
5890
Wireless PIR
5800 Series
Wireless
Devices
4204CF
Supervised
NAC
Module
5816
Door/Window
Miniature
Transmitter
4209U
Group Zoning
Module
5808W3
Smoke
Detectors
Supports Up To 16
Conventional Two-Wire
Smoke Detectors
Notification
Appliance
5869
Commercial
Hold-Up Switch
Supports Up To 64
Conventional Two-Wire
Smoke Detectors
5817CB
Wireless
Commercial
Transmitter
• Installation
The VISTA-128FB alarm system has
been designed to mount both quickly
and easily in an attack resistant
cabinet. It meets all applicable
requirements for UL commercial
burglary installations.
• Electrical:
- Primary power:
- 18 VAC@ 72 VA No. 1450
- Quiescent current draw:
- 350mA
- Backup battery
- 12VDC, 12AH min to
34AAH max
- Lead acid battery (gel type)
- Alarm power
- 12VDC, 1.7A max for each
notification (bell) circuit output
- Aux. standby power
- 12VDC, 1A max
- Total power
- 2.3A at 12VDC, 3.4A at 24VDC
from all sources
- Standby time
- 24 hours with 1A standby load or
60 hours with 205mA max
standby load using 34AAH
battery
- Fusing
- Battery input, aux. and
notification (bell) circuit outputs
are protected using PTC circuit
protectors. All outputs are power
limited.
- Main dialer
- Line seize:
- Double Pole
• Ringer equiv.
- 0.713
VGM (PTVGM)
Vista
Gateway
Module
PassPoint
• Formats
- ADEMCO Low Speed, ADEMCO
4+2 Express, ADEMCO High
Speed, ADEMCO Contact ID,
Sescoa and Radionics
VISTA-128FB/V128FB-24
COMMERCIAL FIRE AND PARTITIONED ALARM PLATFORM
SPECIFICATIONS:
• Auxiliary devices
- 6160CR Alpha Keypad
Commercial Fire
- 6139R - Red Alpha
Keypad/Annunciator
- FSA-8 & FSA-24 Fire System
Annunciator
- 4204 - Relay Module, four form C
contacts
- 4204CF - Two supervised output
circuits
- 6220S - System printer used with
4100SM Serial Interface Module
- 5140DLM, FSA-8, FSA-24,
FSAKSM Fire Annunciator
- 4209U Group Zoning Module two/four zones
- 4293SN One Zone Serial Interface
Module
- 4297 Isolation/Extender Module
• Two-wire and four-wire smoke
detectors conventional
- System Sensor smoke detectors
• V-Plex (addressable) contacts
- 4939SN-WH
- 4944SN-WH
- 4959SN
• Horn/Strobes
- System Sensor notification appliances
• Manual pull stations
- 5140MPS-1
- 5140MPS-2
• V-Plex (addressable) devices
- 4101SN Single Relay/Zone Module
- 4190SN Remote Point Module two zones
- 4190WH Two Point Multiplex RPM
- 4193SN Two Zone Serial Interface
Module
- 4208U Loop Expansion Module eight zones
- 4208SNF Class A/13 Expander
Module
• V-Plex (addressable) smoke
detectors
- 5192SD
- 5192SDT
• Passive infrared detectors
- 998MX
- 4275EX-SN
- 4278EX-SN
- Quest 2260SN
• Glassbreak detectors
- 9500SN
• VISTA Interactive Phone Module
- 4286 Voice Module
• Optional 24V power supply
- PS24 - 24V power supply - 3.4A
• Long range radio
- Long range radio 7720ULF-XX,
7845C, 7835CFPK
• Upgraded software
- Upgraded Compass Downloader
Windows compatible
ORDERING
VISTA-128FB
Commercial Fire and Partitioned Burglary Alarm Platform 12V Model
V128FB-24
Commercial Fire and Partitioned Burglary Alarm Platform 24V Model
For more information: www.honeywell.com/security/hsc
Automation and Control Solutions
Honeywell Security & Communications
2 Corporate Center Dr. Suite 100
Melville, NY 11747
1.800.467.5875
www.honeywell.com
L/VIS128FB/D
May 2009
© 2009 Honeywell International Inc.
• Wireless devices
- 5804 - Wireless Key
- 5804BD - Bi-Directional Key
- 5804BDV - Bi-Directional with voice
- 5816 - Door/Window Transmitter
- 5819 - Shock Sensor
- 5827BD - Bi-Directional Keypad
- 5849 - Glassbreak Detector
- 5881 Series - RF Receiver
supporting 5800 wireless detectors
- 5890 - PIR
• Access control
- VistaKey V-Plex (addressable)
Access Control
- VistaKey-SK Starter Kit
- VistaKey-EX Expansion Kit
- VGM Vista Gateway Module to
PassPoint Access Control
(Honeywell Access Systems)
• CCTV
- VistaView-100-CCTV Switch
Module
• Commercial wireless devices
- 5869 - Hold up Transmitter
- 5817CB - Wireless Commercial
Transmitter
- 5881ENHC - Commercial
Fire/Burg Receiver
- 5808W3 - Wireless Smoke Detector
- 5809 - Wireless Heat Detector