VISTA-128BP BPE Data Sheet

VISTA-128BP SERIES
PARTITIONED COMMERCIAL BURGLARY
ALARM CONTROL PANELS
The VISTA-128BPE is a powerful member of the Honeywell
The VISTA-128BP and VISTA-128BPE (VISTA-128BP Rev. 4)
family of commercial alarm panels, integrating burglary, CCTV
are Listed for residential burglary, residential fire and commercial
and access control functions. Many features are available that
burglary applications (see agency listings in this document for
extend the applications of the VISTA-128BP while simplifying
more details). They are compatible with a wide range of
end-user operation.
AlarmNet communications products for alarm reporting,
uploading/downloading and remote services.
FEATURES
Standard features
(VISTA-128BP and VISTA-128BPE):
• Provides nine style-B hardwired zones
• Supports up to 119 additional zones
using a built-in polling (V-Plex,
multiplex) loop interface
• Supports up to 127 wireless zones
using up to two 5800 series wireless
receivers (fewer if using hardwire
and/or polling loop zones)
• Provides one power-limited bell circuit
delivering 1.7Amp (max) at 12Vdc
• Provides the ability to control eight
separate partitions independently,
each functioning as if it had its own
separate control
• Zone 7 may be used for keyswitch
arming/disarming
• Supports V-Plex® addressable
VistaKey access control (up to eight
doors and 250 cards)
• Easily programmed and maintained
by Compass Windows-based
downloader
• Supports up to 96 programmable
outputs
• Programmable to meet SIA false
alarm prevention specifications.
To meet UL approval for ANSI/SIA
CP-01-2000 order part number
VISTA-128SIA
• Panel Linking up to eight panels
• Accommodates 150 user codes with
seven authority levels
• Supports eight numeric
pager numbers
• Accommodates 32 keypad macro
commands per system
• Supports touchscreen Advanced
User Interface (AUI)
• Keeps a log of up to 512 events
• Smoke detector reset at keypad
• VistaView-100 CCTV support
• Quick exit
• Supports up to 16 compatible twowire smoke detectors on zone 1
• Group bypass
• Supports up to 50 latching-type
glassbreak detectors on zone 8
• Event arming
• Arm faulted
• Scheduled check-in
• Arm stay by group
Enhanced features
(VISTA-128BPE only):
• Carbon monoxide (CO) zone
type support
• Expanded RS-232 capability
for third party interface and
automation
• Internet upload/download over
AlarmNet GSM, iGSM and IP
communicators over the panel's
keypad (ECP) bus
• Ringback support for AlarmNet
communicators (confirmation of
closing report)
• 24-hour dialer test support for
AlarmNet devices
VISTA-128BP SERIES
PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS
ADDITIONAL FEATURES
• A Master partition (9), used strictly to
assign keypads for the purpose of
viewing the status of all eight partitions
at the same time (master keypads)
• Tamper protection for supervised
transmitters
Basic Hardwired Zones
Provides nine style-B hardwired zones
with the following characteristics:
• EOLR supervision (optional for zones
2-8) supporting N.O. or N.C. sensors
(EOLR supervision required for fire
and UL burglary installations)
• Individually assignable to one of
eight partitions
Provides the following scheduling
capabilities:
• Individually assignable to one of
eight partitions
• Open/close schedules (for control of
arming/disarming and reporting)
Polling Loop Expansion
• Holiday schedules (allows different
time windows for open/close
schedules)
Supports up to 119 additional zones
using a built-in polling (V-Plex, multiplex)
loop interface. Current draw can total
up to 128mA. Polling loop zones have
the following characteristics:
• Must use V-Plex devices
• Keypads assignable to one of eight
partitions or to Master partition 9 to
view system status
• Ability to assign relays to one or all
eight partitions
• Ability to display fire and/or burglary
and panic and/or trouble conditions
at all other partitions’ keypads
(selectable option)
• Timed events (for activation of relays,
auto-bypassing and unbypassing,
auto-arming and disarming, etc.)
• Supervised by control panel
• Access schedules (for limiting system
access to users by time)
• Individually assignable to one of
eight partitions
• End user output programming mode
(provides 20 timers for output control)
Wireless Expansion
Eight Partitions
Supports up to 127 wireless zones
using up to two 5800 series wireless
receivers (fewer if using hardwire
and/or polling loop zones).
Provides the ability to control eight
separate areas independently, each
functioning as if it had its own separate
control. Partitioning features include:
Wireless zones have the following
characteristics:
• A Common Lobby partition (1-8),
which can be programmed to arm
automatically when the last partition
that shares the common lobby is
armed, and to disarm when the first
partition that shares the common
lobby is disarmed
• Supervised by control panel for
check-in signals (except certain
non-supervised transmitters)
• All zones assignable to one of
eight partitions
Scheduling
• Individually programmable account
number, entry delay and exit delay by
partition
V-Plex Loop
FG1625SN Glassbreak
4101SN
Relay Module
DT7500SN
V-Plex DUAL TEC
Motion Sensor
4208U Eight-zone
Expansion Module and
4208EX Eight-zone
V-Plex Expander
5193
Series Smoke Detectors
4293SN Adapters
5881
Wireless
Receiver
ECP Bus
6160
Console
Parallel Printer
RS-232
710
Light
VISTA-128BP
Notification
Appliances
4204
Relay
Module
Keyswitch
Option
4146
Serial Printer
Phone Line to Central Station
748
Horn
Alpha Paging
Module
or
7847i
NOTE: Please refer to the website (www.honeywell.com/security/hsc) for the latest product information.
or
GSM
iGSM
VISTA-128BP SERIES
PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS
ACCESSORIES
Auxiliary Devices
• 5193SD
Wireless Devices
• 4204 - Relay Module, four form C
contacts
• 5193SDT
• 5804 - Wireless Key
Passive Infrared Detectors
• 5804BD - Bidirectional Key
• 998MX
• 5804BDV - Bidirectional with voice
• IS2500SN
• 5816 - Door/Window Transmitter
• DT7500SN
• 5819 - Shock Sensor
• QUEST2260SN
• 5827BD - Bidirectional Keypad
• VA8200 - (PLM) Panel Linking Module
V-Plex (Addressable) Contacts
• 5853 - Glassbreak Detector
• VA8201 - (APM) Alpha Paging Module
• 4939SN-WH
• 5894 - Wireless PIR Motion Sensor
Manual Pull Stations
• 4944SN-WH
• 5890 - Passive Infrared Detection
• 5140MPS-1
• 4959SN, 9500SN
• 5140MPS-2
V-Plex Glassbreak Detectors
• 5800PIR-OD - Outdoor
Motion Sensor
V-Plex (addressable) Devices
• FG1625SN
• 4101SN Single Relay/zone Module
VISTA Interactive Phone Module
• 4190SN Remote Point Module two zones
• 4286 VIP Module
• 5881 Series - RF Receiver supporting
5800 wireless detectors
• 6160 - Alpha Keypad/Annunciator
• 6220S - System Printer used with
4100SM serial module
• 5870API - Asset Protection Device
• 5800PIR/5800PIR-RES/5800PIRCOM—Wireless Motion Detectors
• 5800CO/A - Wireless Carbon
Monoxide Detector
Optional Communicators
• 4193SN Two zone Serial Interface
Module
• 5800RP - Wireless Repeater
• AlarmNet Internet/Intranet
communicators and digital cellular
communicators
• 4208EX - Eight zone expander for
ULC commercial installations
• 5808W3 - Wireless Smoke Detector
• 5809 - Wireless Heat Detector
Access Control
• 4208U Loop Expansion Module eight zones
Commercial Listed
Wireless Devices
• VISTAKey V-Plex (addressable)
Access Control
• 4209U Group zoning Module two/four zones
• VISTAKey-EX Expansion Kit
• 5817CB - Commercial UL Burglary,
Universal Contact Monitoring
Transmitter*
CCTV
• 5869 - Commercial UL Wireless
Hold-up Button*
• VISTAKey-SK Starter Kit
• 4293SN One zone Serial Interface
Module
• 4297 Isolation/Extender Module V-Plex
(addressable) smoke detectors
• 5881ENHC and 5883H Receivers
• Optiflex CCTV module
• VSI Short/Overload Isolation Module
IS2500SN
V-Plex PIR
Motion Sensor
ECP
4193SN
4208U
Serial Interface Module
Eight-zone
Expansion Module
5881ENHC
Commercial Wireless Receiver
Bus
(Max Two)
6160
Console
4204
Relay
Module
*When used with 5881ENHC and/or
5883H receiver.
4190SN
Remote Point Module
5808W3
Wireless
Smoke
Detector
5816
Door/Window
Transmitter
4204CF
Supervised
NAC Module
5869
Commercial UL
Wireless Hold-up
Button
4959SN
Overhead Door Contact
4944SN
Contact
Glassbreak Detectors
5800
Series
Wireless
Devices
5890
Wireless PIR
4209U
Group Zoning
Module
5817CB Universal
Contact Monitoring
Transmitter
VISTA-128BP
Panel Linking Module
VISTAKey V-Plex
Access Control
Module
Supports Up To
16 Conventional
Two-Wire
Smoke Detectors
VISTA-128BP
Panel Linking Module
VISTA-128BP SERIES
PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS
SPECIFICATIONS
Electrical
Main Dialer
• UL609 Grade A Local Mercantile
Premises and Mercantile Safe
and Vault
• Voltage Input: From Honeywell No.
1361 Plug-In Transformer or
1361X10 transformer (for X-10
installations) rated 16.5VAC, 40 VA
• UL611/UL1610 Grades A, AA
Central Station
• Use 1361CN plug-in transformer
for Canada
• Formats Supported: ADEMCO
Contact ID, ADEMCO High Speed,
ADEMCO 4 + 2 Express, ADEMCO
Low Speed, Sescoa and Radionics
Low Speed
• UL365 Grades A, AA Police Connect
• Alarm Sounder Output: 10VDC13.8VDC, 1.7 amps max., (UL1023,
UL609 installations); 750mA less aux.
current draw (UL985 installations)
Agency Listed to the
Following Standards:
• UL985 Household Fire
• UL1023 Household Burglar Alarm
California State Fire Marshall (CSFM)
• UL1635 - Digital Alarm
Communicator System Units
• CAN/ULC - S303
• CAN/ULC - S304
• CAN/ULC - S545
• CAN/ULC - S1023
• For commercial burglary attack proof
requirements, use VISTA-ULKT attack
proof enclosure
• Line Seize: Double Pole
• Ringer Equivalence: 0.7B
Cabinet Dimensions
12-1/2" W X 14 1/2" H X 3" D
• Auxiliary Power Output: 9.6VDC13.8VDC, 750mA max. For UL
installations, the accessories
connected to the output must be UL
Listed, and rated to operate in the
above voltage range
• Backup Battery: 12VDC, 4AH or 7AH
sealed-lead acid. YUASA NP4-12
(12V, 4AH) or NP7-12 (12V, 7AH)
recommended
• Standby Time: Four hours min. with
750mA aux. load using 7AH battery
• Circuit Protectors: PTC circuit
breakers are used on battery input to
protect against reverse battery
connections and on alarm sounder
output to protect against wiring faults
(shorts). A solid state circuit breaker
is used on auxiliary power output to
protect against wiring faults (shorts).
ORDERING
VISTA-128BP
Commercial Burglary Alarm Control Panel (UL Listed)
VISTA-128BPE
Enhanced Commercial Burglary Alarm Control Panel (ETL Listed as VISTA-128BP Rev. 4, UL Pending)
VISTA-128SIAE
SIA Approved Enhanced Commercial Burglary Alarm Control Panel
For more information:
www.honeywell.com/security/hsc
Automation and Control Solutions
Honeywell Security & Communications
2 Corporate Center Dr. Suite 100
P.O. Box 9040
Melville, NY 11747
1.800.467.5875
www.honeywell.com
L/VSTA128BPD/D
April 2010
© 2010 Honeywell International Inc.