VISTA-128BP SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS The VISTA-128BPE is a powerful member of the Honeywell The VISTA-128BP and VISTA-128BPE (VISTA-128BP Rev. 4) family of commercial alarm panels, integrating burglary, CCTV are Listed for residential burglary, residential fire and commercial and access control functions. Many features are available that burglary applications (see agency listings in this document for extend the applications of the VISTA-128BP while simplifying more details). They are compatible with a wide range of end-user operation. AlarmNet communications products for alarm reporting, uploading/downloading and remote services. FEATURES Standard features (VISTA-128BP and VISTA-128BPE): • Provides nine style-B hardwired zones • Supports up to 119 additional zones using a built-in polling (V-Plex, multiplex) loop interface • Supports up to 127 wireless zones using up to two 5800 series wireless receivers (fewer if using hardwire and/or polling loop zones) • Provides one power-limited bell circuit delivering 1.7Amp (max) at 12Vdc • Provides the ability to control eight separate partitions independently, each functioning as if it had its own separate control • Zone 7 may be used for keyswitch arming/disarming • Supports V-Plex® addressable VistaKey access control (up to eight doors and 250 cards) • Easily programmed and maintained by Compass Windows-based downloader • Supports up to 96 programmable outputs • Programmable to meet SIA false alarm prevention specifications. To meet UL approval for ANSI/SIA CP-01-2000 order part number VISTA-128SIA • Panel Linking up to eight panels • Accommodates 150 user codes with seven authority levels • Supports eight numeric pager numbers • Accommodates 32 keypad macro commands per system • Supports touchscreen Advanced User Interface (AUI) • Keeps a log of up to 512 events • Smoke detector reset at keypad • VistaView-100 CCTV support • Quick exit • Supports up to 16 compatible twowire smoke detectors on zone 1 • Group bypass • Supports up to 50 latching-type glassbreak detectors on zone 8 • Event arming • Arm faulted • Scheduled check-in • Arm stay by group Enhanced features (VISTA-128BPE only): • Carbon monoxide (CO) zone type support • Expanded RS-232 capability for third party interface and automation • Internet upload/download over AlarmNet GSM, iGSM and IP communicators over the panel's keypad (ECP) bus • Ringback support for AlarmNet communicators (confirmation of closing report) • 24-hour dialer test support for AlarmNet devices VISTA-128BP SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS ADDITIONAL FEATURES • A Master partition (9), used strictly to assign keypads for the purpose of viewing the status of all eight partitions at the same time (master keypads) • Tamper protection for supervised transmitters Basic Hardwired Zones Provides nine style-B hardwired zones with the following characteristics: • EOLR supervision (optional for zones 2-8) supporting N.O. or N.C. sensors (EOLR supervision required for fire and UL burglary installations) • Individually assignable to one of eight partitions Provides the following scheduling capabilities: • Individually assignable to one of eight partitions • Open/close schedules (for control of arming/disarming and reporting) Polling Loop Expansion • Holiday schedules (allows different time windows for open/close schedules) Supports up to 119 additional zones using a built-in polling (V-Plex, multiplex) loop interface. Current draw can total up to 128mA. Polling loop zones have the following characteristics: • Must use V-Plex devices • Keypads assignable to one of eight partitions or to Master partition 9 to view system status • Ability to assign relays to one or all eight partitions • Ability to display fire and/or burglary and panic and/or trouble conditions at all other partitions’ keypads (selectable option) • Timed events (for activation of relays, auto-bypassing and unbypassing, auto-arming and disarming, etc.) • Supervised by control panel • Access schedules (for limiting system access to users by time) • Individually assignable to one of eight partitions • End user output programming mode (provides 20 timers for output control) Wireless Expansion Eight Partitions Supports up to 127 wireless zones using up to two 5800 series wireless receivers (fewer if using hardwire and/or polling loop zones). Provides the ability to control eight separate areas independently, each functioning as if it had its own separate control. Partitioning features include: Wireless zones have the following characteristics: • A Common Lobby partition (1-8), which can be programmed to arm automatically when the last partition that shares the common lobby is armed, and to disarm when the first partition that shares the common lobby is disarmed • Supervised by control panel for check-in signals (except certain non-supervised transmitters) • All zones assignable to one of eight partitions Scheduling • Individually programmable account number, entry delay and exit delay by partition V-Plex Loop FG1625SN Glassbreak 4101SN Relay Module DT7500SN V-Plex DUAL TEC Motion Sensor 4208U Eight-zone Expansion Module and 4208EX Eight-zone V-Plex Expander 5193 Series Smoke Detectors 4293SN Adapters 5881 Wireless Receiver ECP Bus 6160 Console Parallel Printer RS-232 710 Light VISTA-128BP Notification Appliances 4204 Relay Module Keyswitch Option 4146 Serial Printer Phone Line to Central Station 748 Horn Alpha Paging Module or 7847i NOTE: Please refer to the website (www.honeywell.com/security/hsc) for the latest product information. or GSM iGSM VISTA-128BP SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS ACCESSORIES Auxiliary Devices • 5193SD Wireless Devices • 4204 - Relay Module, four form C contacts • 5193SDT • 5804 - Wireless Key Passive Infrared Detectors • 5804BD - Bidirectional Key • 998MX • 5804BDV - Bidirectional with voice • IS2500SN • 5816 - Door/Window Transmitter • DT7500SN • 5819 - Shock Sensor • QUEST2260SN • 5827BD - Bidirectional Keypad • VA8200 - (PLM) Panel Linking Module V-Plex (Addressable) Contacts • 5853 - Glassbreak Detector • VA8201 - (APM) Alpha Paging Module • 4939SN-WH • 5894 - Wireless PIR Motion Sensor Manual Pull Stations • 4944SN-WH • 5890 - Passive Infrared Detection • 5140MPS-1 • 4959SN, 9500SN • 5140MPS-2 V-Plex Glassbreak Detectors • 5800PIR-OD - Outdoor Motion Sensor V-Plex (addressable) Devices • FG1625SN • 4101SN Single Relay/zone Module VISTA Interactive Phone Module • 4190SN Remote Point Module two zones • 4286 VIP Module • 5881 Series - RF Receiver supporting 5800 wireless detectors • 6160 - Alpha Keypad/Annunciator • 6220S - System Printer used with 4100SM serial module • 5870API - Asset Protection Device • 5800PIR/5800PIR-RES/5800PIRCOM—Wireless Motion Detectors • 5800CO/A - Wireless Carbon Monoxide Detector Optional Communicators • 4193SN Two zone Serial Interface Module • 5800RP - Wireless Repeater • AlarmNet Internet/Intranet communicators and digital cellular communicators • 4208EX - Eight zone expander for ULC commercial installations • 5808W3 - Wireless Smoke Detector • 5809 - Wireless Heat Detector Access Control • 4208U Loop Expansion Module eight zones Commercial Listed Wireless Devices • VISTAKey V-Plex (addressable) Access Control • 4209U Group zoning Module two/four zones • VISTAKey-EX Expansion Kit • 5817CB - Commercial UL Burglary, Universal Contact Monitoring Transmitter* CCTV • 5869 - Commercial UL Wireless Hold-up Button* • VISTAKey-SK Starter Kit • 4293SN One zone Serial Interface Module • 4297 Isolation/Extender Module V-Plex (addressable) smoke detectors • 5881ENHC and 5883H Receivers • Optiflex CCTV module • VSI Short/Overload Isolation Module IS2500SN V-Plex PIR Motion Sensor ECP 4193SN 4208U Serial Interface Module Eight-zone Expansion Module 5881ENHC Commercial Wireless Receiver Bus (Max Two) 6160 Console 4204 Relay Module *When used with 5881ENHC and/or 5883H receiver. 4190SN Remote Point Module 5808W3 Wireless Smoke Detector 5816 Door/Window Transmitter 4204CF Supervised NAC Module 5869 Commercial UL Wireless Hold-up Button 4959SN Overhead Door Contact 4944SN Contact Glassbreak Detectors 5800 Series Wireless Devices 5890 Wireless PIR 4209U Group Zoning Module 5817CB Universal Contact Monitoring Transmitter VISTA-128BP Panel Linking Module VISTAKey V-Plex Access Control Module Supports Up To 16 Conventional Two-Wire Smoke Detectors VISTA-128BP Panel Linking Module VISTA-128BP SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS SPECIFICATIONS Electrical Main Dialer • UL609 Grade A Local Mercantile Premises and Mercantile Safe and Vault • Voltage Input: From Honeywell No. 1361 Plug-In Transformer or 1361X10 transformer (for X-10 installations) rated 16.5VAC, 40 VA • UL611/UL1610 Grades A, AA Central Station • Use 1361CN plug-in transformer for Canada • Formats Supported: ADEMCO Contact ID, ADEMCO High Speed, ADEMCO 4 + 2 Express, ADEMCO Low Speed, Sescoa and Radionics Low Speed • UL365 Grades A, AA Police Connect • Alarm Sounder Output: 10VDC13.8VDC, 1.7 amps max., (UL1023, UL609 installations); 750mA less aux. current draw (UL985 installations) Agency Listed to the Following Standards: • UL985 Household Fire • UL1023 Household Burglar Alarm California State Fire Marshall (CSFM) • UL1635 - Digital Alarm Communicator System Units • CAN/ULC - S303 • CAN/ULC - S304 • CAN/ULC - S545 • CAN/ULC - S1023 • For commercial burglary attack proof requirements, use VISTA-ULKT attack proof enclosure • Line Seize: Double Pole • Ringer Equivalence: 0.7B Cabinet Dimensions 12-1/2" W X 14 1/2" H X 3" D • Auxiliary Power Output: 9.6VDC13.8VDC, 750mA max. For UL installations, the accessories connected to the output must be UL Listed, and rated to operate in the above voltage range • Backup Battery: 12VDC, 4AH or 7AH sealed-lead acid. YUASA NP4-12 (12V, 4AH) or NP7-12 (12V, 7AH) recommended • Standby Time: Four hours min. with 750mA aux. load using 7AH battery • Circuit Protectors: PTC circuit breakers are used on battery input to protect against reverse battery connections and on alarm sounder output to protect against wiring faults (shorts). A solid state circuit breaker is used on auxiliary power output to protect against wiring faults (shorts). ORDERING VISTA-128BP Commercial Burglary Alarm Control Panel (UL Listed) VISTA-128BPE Enhanced Commercial Burglary Alarm Control Panel (ETL Listed as VISTA-128BP Rev. 4, UL Pending) VISTA-128SIAE SIA Approved Enhanced Commercial Burglary Alarm Control Panel For more information: www.honeywell.com/security/hsc Automation and Control Solutions Honeywell Security & Communications 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 1.800.467.5875 www.honeywell.com L/VSTA128BPD/D April 2010 © 2010 Honeywell International Inc.