data sheet - family

My-Com precision switches
MY-COM A
My-Com precision switches
sample drawing
M8 x 0,5
ø 5
20
30
18
SW 10
1,5
ø 1
M8 x 1
general data
sample picture
repeat accuracy
< 0,001 mm
mech. pre-run / overrun
- / 1,5 mm approx.
measurement type
contact with medium
direction of approach
frontal
electrical data
DC voltage max.
15 VDC
switch. current DC max.
2 mA
AC voltage max.
24 VAC
switch. current AC max.
50 mA
output circuit
break function (NC) mechanical
mechanical data
activating pin
zirconium oxide ZrO2
housing material
brass nickel plated
dimension
8 mm
type
cylindrical threaded
ambient conditions
operating temperature
-20 ... +75 °C
protection class
IP 50
order reference
activating force
connection types
housing length
MY-COM A100/80
100 cN
cable, 80 cm
20 mm
MY-COM A100/S35
100 cN
connector M8
30 mm
MY-COM A30/80
30 cN
cable, 80 cm
20 mm
MY-COM A30/S35
30 cN
connector M8
30 mm
MY-COM A50/80
50 cN
cable, 80 cm
20 mm
MY-COM A50/S35
50 cN
connector M8
30 mm
MY-COM A75/80
75 cN
cable, 80 cm
20 mm
MY-COM A75/S35
75 cN
connector M8
30 mm
1
www.baumer.com
8/1/2014