data sheet - family

My-Com precision switches
MY-COM E (2-wire)
My-Com precision switches
sample drawing
M6 x 0,5
1,2
ø 2,5
36
15
SW 8
ø 10
general data
sample picture
repeat accuracy
< 0,001 mm
mech. pre-run / overrun
- / 0,8 ... 1,5 mm approx.
measurement type
contact with medium
direction of approach
frontal and lateral approach
electrical data
DC voltage max.
15 VDC
switch. current DC max.
2 mA
AC voltage max.
24 VAC
switch. current AC max.
50 mA
output circuit
break function (NC) mechanical
mechanical data
activating pin
hardened steel
housing material
brass nickel plated
dimension
6 mm
type
cylindrical threaded
housing length
36 mm
connection types
cable, 80 cm
ambient conditions
operating temperature
-20 ... +75 °C
protection class
IP 50
order reference
activating force
MY-COM E100/80
100 cN
MY-COM E75/80
75 cN
1
www.baumer.com
9/1/2014