My-Com precision switches MY-COM C My-Com precision switches sample drawing 12 9 4 8 20 30 2,5 12 4 1,5 ø 1 M8 x 1 general data sample picture repeat accuracy < 0,001 mm mech. pre-run / overrun - / 1,5 mm approx. measurement type contact with medium direction of approach frontal electrical data DC voltage max. 15 VDC switch. current DC max. 2 mA AC voltage max. 24 VAC switch. current AC max. 50 mA output circuit break function (NC) mechanical mechanical data activating pin zirconium oxide ZrO2 housing material brass nickel plated dimension 8 mm type rectangular ambient conditions operating temperature -20 ... +75 °C protection class IP 50 order reference activating force connection types housing length MY-COM C100/80 100 cN cable, 80 cm 20 mm MY-COM C100/S35 100 cN connector M8 30 mm MY-COM C30/80 30 cN cable, 80 cm 20 mm MY-COM C30/S35 30 cN connector M8 30 mm MY-COM C50/80 50 cN cable, 80 cm 20 mm MY-COM C50/S35 50 cN connector M8 30 mm MY-COM C75/80 75 cN cable, 80 cm 20 mm MY-COM C75/S35 75 cN connector M8 30 mm 1 www.baumer.com 8/1/2014