74AUP2G08 DUAL AND GATE Description Pin Assignments The Advanced Ultra Low Power (AUP) CMOS logic family is designed (Top View) for low power and extended battery life in portable applications. The 74AUP2G08 is a dual two input AND gate. Both gates have NEW PRODUCT push-pull outputs designed for operation over a power supply range of 0.8V to 3.6V. The device is fully specified for partial power down applications using IOFF. The IOFF circuitry disables the output preventing damaging current backflow when the device is powered down. Each gate performs the positive Boolean function: Y = A •B or Y =A+B X2-DFN1210-8 Features Applications • Advanced Ultra Low Power (AUP) CMOS • • • Supply Voltage Range from 0.8V to 3.6V ±4mA Output Drive at 3.0V • • • • Suited for Battery and Low Power Needs Wide Array of Products Such as: Tablets, E-readers Low Static Power Consumption ICC < 0.9µA Cell Phones, Personal Navigation/GPS MP3 Players, Cameras, Video Recorders Low Dynamic Power Consumption CPD = 6 pF (Typical at 3.6V) PCs, Ultrabooks, Notebooks, Netbooks Computer Peripherals, Hard Drives, SSD, CD/DVD ROM Schmitt Trigger Action at all inputs makes the circuit tolerant TV, DVD, DVR, Set-Top Box for slower input rise and fall time. The hysteresis is typically 250 mV at VCC = 3.0V • IOFF Supports Partial-Power-Down Mode Operation • ESD Protection Exceeds JESD 22 2000-V Human Body Model (A114) Exceeds 1000-V Charged Device Model (C101) • Latch-Up Exceeds 100mA per JESD 78, Class I • Leadless Packages Named per JESD30E • Totally Lead-Free & Fully RoHS Compliant (Notes 1 & 2) • Halogen and Antimony Free. “Green” Device (Note 3) Notes: 1. No purposely added lead. Fully EU Directive 2002/95/EC (RoHS) & 2011/65/EU (RoHS 2) compliant. 2. See http://www.diodes.com/quality/lead_free.html for more information about Diodes Incorporated’s definitions of Halogen- and Antimony-free, "Green" and Lead-free. 3. Halogen- and Antimony-free "Green” products are defined as those which contain <900ppm bromine, <900ppm chlorine (<1500ppm total Br + Cl) and <1000ppm antimony compounds. 74AUP2G08 Document number: DS36141 Rev. 1 - 2 1 of 9 www.diodes.com January 2015 © Diodes Incorporated 74AUP2G08 Ordering Information 74AUP2G Logic Device Function NEW PRODUCT 74 : Logic Prefix AUP : 0.8 to 3.6 V Logic Family 2G : Dual Gate Device 08 : XXX -7 Package RA3 : X2-DFN1210-8 Package Code Package (Notes 4 & 5) Package Size RA3 X2-DFN1210-8 1.2mm X 1.0mm X 0.35mm 0.3 mm lead pitch 74AUP2G08RA3-7 Notes: 2-Input AND Gates 08 Packing -7 : 7” Tape & Reel 7” Tape and Reel Quantity Part Number Suffix 5,000/Tape & Reel -7 4. Pad layout as shown on Diodes Inc. suggested pad layout document AP02001, which can be found on our website at http://www.diodes.com/datasheets/ap02001.pdf. 5. The taping orientation is located on our website at http://www.diodes.com/datasheets/ap02007.pdf. Pin Descriptions Logic Diagram Pin Name Pin 1A 1 Data Input Function 1B 2 Data Input 2Y 3 Data Output GND 4 Ground 2A 5 Data Input 2B 6 Data Input 1Y 7 Data Output VCC 8 Supply Voltage Function Table Inputs Output A B Y L L L L H L H L L H H H 74AUP2G08 Document number: DS36141 Rev. 1 - 2 2 of 9 www.diodes.com January 2015 © Diodes Incorporated 74AUP2G08 Absolute Maximum Ratings (Note 6 & 7) Symbol Description Rating Unit ESD HBM Human Body Model ESD Protection 2 kV ESD CDM Charged Device Model ESD Protection 1 kV 200 V Supply Voltage Range -0.5 to +4.6 V VI Input Voltage Range -0.5 to +4.6 V Vo Voltage Applied to Output in High or Low State -0.5 to VCC +0.5 V IIK Input Clamp Current VI<0 50 mA IOK Output Clamp Current (VO < 0 ) 50 mA IO Continuous Output Current (VO = 0 to VCC) ±20 mA ICC Continuous Current Through VCC 50 mA IGND Continuous Current Through GND -50 mA Operating Junction Temperature -40 to +150 °C Storage Temperature -65 to +150 °C ESD MM NEW PRODUCT VCC TJ TSTG Notes: Machine Model ESD Protection 6. Stresses beyond the absolute maximum may result in immediate failure or reduced reliability. These are stress values and device operation should be within recommend values. 7. Forcing the maximum allowed voltage could cause a condition exceeding the maximum current or conversely forcing the maximum current could cause a condition exceeding the maximum voltage. The ratings of both current and voltage must be maintained within the controlled range. Recommended Operating Conditions (Note 8) Symbol VCC Parameter Operating Voltage Min Max Unit 0.8 3.6 V VI Input Voltage 0 3.6 V VO Output Voltage 0 VCC V µA IOH IOL High-Level Output Current Low-Level Output Current ∆t/∆V Input Transition Rise or Fall Rate TA Operating Free-Air Temperature Note: — VCC = 0.8V — -20 VCC = 1.1V — -1.1 VCC = 1.4V — -1.7 VCC = 1.65V — -1.9 VCC = 2.3V — -3.1 VCC = 3.0V — -4 VCC = 0.8V — 20 VCC = 1.1V — 1.1 VCC = 1.4V — 1.7 VCC = 1.65V — 1.9 VCC = 2.3V — 3.1 VCC = 3.0V — 4 VCC = 0.8V to 3.6V — mA µA mA — 200 ns/V -40 +125 °C 8. Unused inputs should be held at VCC or Ground. 74AUP2G08 Document number: DS36141 Rev. 1 - 2 3 of 9 www.diodes.com January 2015 © Diodes Incorporated 74AUP2G08 Electrical Characteristics Symbol NEW PRODUCT VIH VIL VOH Parameter Test Conditions — 0.8V to 1.65V 1.65V to 1.95V — — — 2.3V to 2.7V 3.0V to 3.6V 0.8V to 1.65V 0.65 X VCC 1.6 2.0 — Low-Level Input Voltage — 1.65V to 1.95V — — — — — 0.35 X VCC 0.7 0.9 IOH = -20μA 2.3V to 2.7V 3.0V to 3.6V 0.8V to 3.6V VCC – 0.1 — VCC – 0.1 IOH = -1.1mA 1.1V 0.75 X VCC — 0.7 X VCC — IOH = -1.7mA 1.4V 1.11 — 1.03 — High-Level Output IOH = -1.9mA Voltage IOH = -2.3mA 1.65V 1.32 — 1.3 — 2.05 — 1.97 — IOH = -4mA Low-Level Input Voltage ∆IOFF ICC ∆ICC Power Down Leakage Current Delta Power Down Leakage Current Supply Current 3V 0.30 X VCC 0.65 X VCC 1.6 2.0 — — — — — — — V 0.30 X VCC 0.35 X VCC 0.7 0.9 — 1.9 — 1.85 — 2.72 — 2.67 — 2.6 — 2.55 — — 0.1 — 0.1 0.3 X VCC V V 0.8V to 3.6V IOL = 1.1mA 1.1V — 0.3 X VCC — IOL = 1.7mA 1.4V — 0.31 — 0.37 IOL = 1.9mA 1.65V — 0.31 — 0.35 — 0.31 — 0.33 — 0.44 — 0.45 — 0.31 — 0.33 — 0.44 — 0.45 0V to 3.6V — ± 0.1 — ± 0.5 µA VI or VO = 0V to 3.6V 0V — ± 0.2 — ± 0.6 µA VI or VO = 0V to 3.6V 0V to 0.2V — ± 0.2 — ± 0.6 µA 0.8V to 3.6V — 0.5 — 0.9 µA 50 µA IOL = 2.3mA IOL = 2.7mA Input Current 2.3V — — — Unit IOL = 20μA IOL = 3.1mA IOFF TA = -40°C to +85°C Min Max — 0.80 X VCC — IOH = -2.7mA II TA = +25°C Min Max — 0.80 X VCC High-Level Input Voltage IOH = -3.1mA VOL VCC IOL = 4mA A or B Input VI = GND to 3.6V VI = GND or VCC, IO = 0 One Input at VCC –0.6V Additional Supply Other Inputs at VCC or Current GND 74AUP2G08 Document number: DS36141 Rev. 1 - 2 2.3V 3V V — 3.3V — 4 of 9 www.diodes.com 40 January 2015 © Diodes Incorporated 74AUP2G08 Electrical Characteristics (cont.) Symbol NEW PRODUCT VIH VIL VOH Parameter Test Conditions High-Level Input Voltage 0.8V to 1.65V 0.80 X VCC — — 1.65V to 1.95V 0.70 X VCC — — — 2.3V to 2.7V 3.0V to 3.6V 1.6 2.0 — — — — 0.25 X VCC 1.65V to 1.95V — 0.30 X VCC — — 2.3V to 2.7V 3.0V to 3.6V — — 0.7 0.9 IOH = -20μA 0.8V to 3.6V VCC – 0.11 — IOH = -1.1mA 1.1V 0.6 X VCC — IOH = -1.7mA 1.4V 0.93 — IOH = -1.9mA 1.65V 1.17 — 1.77 — 1.67 — 2.40 — 2.3V IOH = -2.7mA 3V IOH = -4mA 0.8V to 3.6V — 0.11 IOL = 1.1mA 1.1V — 0.33 X VCC IOL = 1.7mA 1.4V — 0.41 IOL = 1.9mA 1.65V — 0.39 — 0.36 — 0.50 — 0.36 IOL = 2.3mA 2.3V IOL = 2.7mA 3V IOL = 4mA IOFF ∆IOFF ICC ∆ICC — V V IOL = 20μA IOL = 3.1mA II 2.30 Unit V 0.8V to 1.65V IOH = -2.3mA Low-Level Input Voltage Max — IOH = -3.1mA VOL Min — Low-Level Input Voltage High-Level Output Voltage TA = -40°C to +125°C VCC V — 0.50 0V to 3.6V — ± 0.75 μA Input Current A or B Input, VI = GND to 3.6V Power Down Leakage Current VI or VO = 0V to 3.6V 0V — ± 1.0 μA Delta Power Down Leakage Current VI or VO = 0V to 3.6V 0V to 0.2V — ± 2.5 μA Supply Current VI = GND or VCC, IO = 0 0.8V to 3.6V — 3.0 μA Additional Supply Current Input at VCC –0.6V Other Inputs at VCC or GND 3.3V — 75 μA Operating and Package Characteristics (@TA = +25°C, unless otherwise specified.) Parameter VCC Typ Unit 0.8V 1.2V ± 0.1V 1.5V ± 0.1V 5.1 5.2 5.2 1.8V ± 0.15V 2.5V ± 0.2V 3.3V ± 0.3V 5.5 5.7 6.0 0V or 3.3V 2.0 pF Power Dissipation Capacitance f = 1MHz No Load Ci Input Capacitance Vi = VCC or GND θJA Thermal Resistance Junction-to-Ambient X2-DFN1210-8 (Note 9) — +395 °C/W θJC Thermal Resistance Junction-to-Case X2-DFN1210-8 (Note 9) — +236 °C/W Cpd Note: Test Conditions pF 9. Test condition, X2-DFN1210-8 device mounted on FR-4 substrate PC board, 2oz copper, with minimum recommended pad layout. 74AUP2G08 Document number: DS36141 Rev. 1 - 2 5 of 9 www.diodes.com January 2015 © Diodes Incorporated 74AUP2G08 Switching Characteristics CL = 5pF, See Figure 1 Parameter NEW PRODUCT tpd From Input A or B To Output VCC Y 0.8V 1.2V ± 0.1V 1.5V ± 0.1V 1.8V ± 0.15V 2.5V ± 0.2V 3.3V ± 0.3V To Output VCC Y 0.8V 1.2V ± 0.1V 1.5V ± 0.1V 1.8V ± 0.15V 2.5V ± 0.2V 3.3V ± 0.3V To Output VCC Y 0.8V 1.2V ± 0.1V 1.5V ± 0.1V 1.8V ± 0.15V 2.5V ± 0.2V 3.3V ± 0.3V To Output VCC Y 0.8V 1.2V ± 0.1V 1.5V ± 0.1V 1.8V ± 0.15V 2.5V ± 0.2V 3.3V ± 0.3V Min — 2.6 1.6 1.3 1.1 1.0 TA = +25°C Typ 19.6 5.1 3.7 3.0 2.4 2.2 Max — 11.9 6.5 5.2 4.0 3.5 TA = -40°C to +85°C Min Max — — 2.1 12.9 1.5 7.5 1.3 6.1 1.0 4.8 0.9 4.3 TA = -40°C to +125°C Min Max — — 2.1 14.2 1.5 8.3 1.3 6.7 1.0 5.3 0.9 4.8 Min — 2.4 2.0 1.7 1.4 1.3 TA = +25°C Typ 23.7 6.0 4.3 3.6 2.9 2.7 Max — 13.8 7.6 6.1 4.8 4.2 TA = -40°C to +85°C Min Max — — 2.2 15.0 1.8 8.9 1.6 7.2 1.3 5.7 1.2 4.7 TA = -40°C to +125°C Min Max — — 2.2 16.5 1.8 9.8 1.6 7.9 1.3 6.3 1.2 5.2 Min — 3.4 2.3 1.9 1.7 1.4 TA = +25°C Typ 27.7 6.8 4.9 4.0 3.4 3.1 Max — 15.6 8.6 6.9 5.5 4.8 TA = -40°C to +85°C Min Max — — 3.1 19.3 2.1 10.1 1.8 8.2 1.6 6.5 1.4 5.9 TA = -40°C to +125°C Min Max — — 3.1 19.5 2.1 11.2 1.8 9.0 1.6 7.2 1.4 6.5 Min — 4.6 3.4 2.6 2.3 1.9 TA = +25°C Typ 39.6 9.1 6.4 5.3 4.5 4.2 Max — 21.3 11.5 9.1 7.2 6.2 TA = -40°C to +85°C Min Max — — 4.1 26.8 2.9 13.6 2.4 10.9 2.2 8.6 1.8 7.5 TA = -40°C to +125°C Min Max — — 4.1 27.0 2.9 15.0 2.4 12.1 2.2 9.5 1.8 8.3 Unit ns CL = 10pF, See Figure 1 Parameter tpd From Input A or B Unit ns CL = 15pF, See Figure 1 Parameter tpd From Input A or B Unit ns CL = 30pF, See Figure 1 Parameter tpd From Input A or B 74AUP2G08 Document number: DS36141 Rev. 1 - 2 6 of 9 www.diodes.com Unit ns January 2015 © Diodes Incorporated 74AUP2G08 Parameter Measurement Information From Output Under Test CL R L=1MΩ NEW PRODUCT (see Note A) VCC Inputs VM CL 0.8V VCC tr/tf ≤3ns VCC/2 5, 10, 15, 30pF 1.2V ± 0.1V VCC ≤3ns VCC/2 5, 10, 15, 30pF VCC ≤3ns VCC/2 5, 10, 15, 30pF 1.8V ± 0.15V VCC ≤3ns VCC/2 5, 10, 15, 30pF 2.5V ± 0.2V VCC ≤3ns VCC/2 5, 10, 15, 30pF 3.3V ± 0.3V VCC ≤3ns VCC/2 5, 10, 15, 30pF 1.5V ± 0.1V VI Voltage Waveform Pulse Duration Voltage Waveform Propagation Delay Times Inverting and Non Inverting Outputs Figure 1 Load Circuit and Voltage Waveforms Notes: A. Includes test lead and test apparatus capacitance. B. All pulses are supplied at pulse repetition rate ≤ 10 MHz. C. Inputs are measured separately one transition per measurement. D. tPLH and tPHL are the same as tPD. 74AUP2G08 Document number: DS36141 Rev. 1 - 2 7 of 9 www.diodes.com January 2015 © Diodes Incorporated 74AUP2G08 Marking Information X2-DFN1210-8 ( Top View ) xx NEW PRODUCT YWX X2-DFN1210-8 XX : Identification Code Y : Year : 0~9 W : week : A~Z : 1~26 week a~z: 27-52 week z represents 52 and 53 week X : week : A~Z : Internal code Part Number Package Identification Code 74AUP2G08RA3-7 X2-DFN1210-8 CT Package Outline Dimensions and Suggested Pad Layout Please see AP02002 at http://www.diodes.com/datasheets/ap02002.pdf for the latest version. X2-DFN1210-8 1 A A Seating Plane D ︵ X 4 Z e (Pin #1 ID) C0.5X45° ︶ X 4 1 Z 1 L ︵ ︶ Dim Min Max Typ A - 0.35 0.30 A1 0 0.03 0.02 b 0.10 0.20 0.15 D 1.15 1.25 1.20 E 0.95 1.05 1.00 e - - 0.30 0.25 K 1 K E K - - K1 - - 0.20 L 0.25 0.35 0.30 L1 0.30 0.40 0.35 Z 0.050 0.100 0.075 Z1 0.050 0.100 0.075 x 7 L All Dimensions in mm b ︵ ︶ 1 X G 2 Y Y Document number: DS36141 Rev. 1 - 2 X C 74AUP2G08 8 of 9 www.diodes.com Dimensions Value (in mm) C 0.300 G 0.150 X 0.150 X1 1.050 Y 0.500 Y1 1.150 January 2015 © Diodes Incorporated 74AUP2G08 IMPORTANT NOTICE NEW PRODUCT DIODES INCORPORATED MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARDS TO THIS DOCUMENT, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION). Diodes Incorporated and its subsidiaries reserve the right to make modifications, enhancements, improvements, corrections or other changes without further notice to this document and any product described herein. Diodes Incorporated does not assume any liability arising out of the application or use of this document or any product described herein; neither does Diodes Incorporated convey any license under its patent or trademark rights, nor the rights of others. Any Customer or user of this document or products described herein in such applications shall assume all risks of such use and will agree to hold Diodes Incorporated and all the companies whose products are represented on Diodes Incorporated website, harmless against all damages. Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthorized sales channel. Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized application. Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more United States, international or foreign trademarks. This document is written in English but may be translated into multiple languages for reference. Only the English version of this document is the final and determinative format released by Diodes Incorporated. LIFE SUPPORT Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in significant injury to the user. B. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or to affect its safety or effectiveness. Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of Diodes Incorporated products in such safety-critical, life support devices or systems, notwithstanding any devices- or systemsrelated information or support that may be provided by Diodes Incorporated. Further, Customers must fully indemnify Diodes Incorporated and its representatives against any damages arising out of the use of Diodes Incorporated products in such safety-critical, life support devices or systems. Copyright © 2015, Diodes Incorporated www.diodes.com 74AUP2G08 Document number: DS36141 Rev. 1 - 2 9 of 9 www.diodes.com January 2015 © Diodes Incorporated