Download

Ionizer (Basic Fan Type)
ZJ-FA20
CSM_ZJ-FA20_DS_E_2_1
High-speed, High cost performance
Ionization
• High-speed ionization in only 0.8 seconds.
• Built-in sensor controls the ion balance at all times.
• Fully open structure makes it possible to perform
maintenance simply and safely.
• Can easily be attached to aluminum profiles.
Refer to Safety Precautions on page 2.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Ordering Information
Ionizer
Accessories (sold separafely)
Model
Model
ZJ-FA20
Replacement Filter
ZJ9-FL120N1 (set of 10)
Replacement Discharger Electrode
ZJ9-NDT06FN1 (set of 6)
Ratings and Specifications
Ionizer
Item
Model
ZJ-FA20
Power supply
voltage
24 VDC *1
Current
consumption
900 mA max. (input from included AC adapter)
Discharge voltage
±7 kV
Discharge method
Variable DC
Airflow (m3/min.)
1.4 to 2.3 m3/min (typical)
Ionization time *2
1.2 s (0.8 s with no Filter)
Ion balance *2
±10 V max.
Amount of
generated ozone
0.01 ppm max. (measured at a distance of 50 mm from air outlet)
Indicators
High-voltage output lamp: ION (yellow), Cleaning lamp: CLEANING (orange), Power lamp: POWER (green)
Main functions
Automatic ion balance adjustment, airflow adjustment, manual ion balance adjustment
Ambient
temperature range
Operating and storage: 0 to 50°C (with no icing or condensation)
Ambient humidity
range
Operating: 35% to 65%, storage: 35% to 85% (with no condensation)
Weight (packed
state)
Approx. 2.0 kg
Materials
Unit: ABS, Discharger: Tungsten, stand: SPCC
Accessories
Instruction sheet, AC adapter, warning labels (2 types), FG connection cable (2 m)
*1. Be sure to use the included AC adapter for Ionizer operation.
*2. Typical default settings.
Measurement location and conditions: Center of air outlet at a distance of 300 mm, with maximum fan speed
Ionization time: The time required to lower the charge from ±1,000 V to ±100 V
Ion balance measurement time: 10 s
Plate monitor: 150 × 150 mm, 20 pF
1
ZJ-FA20
AC Adapter (Provided: UIA336-24-JR01A-998 by UNIFIVE CO., LTD.)
Item
Input voltage
100 to 240 VAC, 50/60 Hz
Power consumption
100 VAC: 70 VA max.
240 VAC: 115 VA max.
Output voltage
24 VDC
Output current
1.5 A max.
Ambient temperature range 0 to 40°C
Ambient humidity range
35% to 85% (with no condensation)
Weight
Approx. 175 g (excluding power cable)
Dimensions
43.8 × 28 × 95.9 (W × D × H) mm
* If an additional AC adapter is required, please contact your OMRON sales representative.
Engineering Data (Reference Value)
Airflow vs. Ionization Time
Ionization Area vs. Ionization Time
3
300
2s
Adjustment dial setting
Ionization time (s)
2.5
200
MIN: 1
ZJ-FA20
2
3s
4s
1s
100
2
3
1.5
0
4
MAX: 5
1
-100
0.5
0
-200
0.5
0.8
1.0
1.3
1.5
1.8
2.0
Airflow (m/s)
Measurement Conditions
Installation distance: 300 mm
Ionization time: ±1,000 V to ±100 V
Plate monitor: 150 × 150 mm, 20 pF
-300
0
(mm)
200
400
600
Distance direction
800
(mm)
Measurement Conditions
Airflow: Max.
Ionization time: ±1,000 V to ±100 V
Plate monitor: 150 × 150 mm, 20 pF
Safety Precautions
WARNING
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Precaution for Correct Use
Do not use the product in atmospheres or environments that exceed
product ratings.
This document provides information mainly for
selecting suitable models. Information such as the
usage precautions is not contained herein.
Be sure to read the instruction manual before using the product.
For technical information and product FAQs,
refer to the Technical Guide on your OMRON
website.
2
ZJ-FA20
(Unit: mm)
Dimensions
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
197.5
8.5
140
80
12
Mounting Hole Dimensions
120°
60°
5
,M
200
n
ve
Se
220
50 ±0.2
15 ±0.2
149
120
100 ±0.2
Rotation Range
165
4
60°
80
60°
120°
60°
dia
5.5
ee,
Thr
5.5
100
50 d
ia.
.
75
dia.
5.5
3
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2013.5
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2013 All Right Reserved.