Ionizer Basic Fan Type ZJ-FA20 High-speed, High cost performance Ionization 0HHWWKH,QGXVWU\6WDQGDU $VHOHFWURQLFFRPSRQHQWVEHFRPHLQFUHDVLQJO\VPDOOHUDQGGHQVHU SURGXFWLRQOLQHVDUHKDYLQJWRDWWDFKPXFKJUHDWHULPSRUWDQFHWR WKHFRQWURORISUREOHPVUHODWHGWRVWDWLFHOHFWULFLW\VXFKDVWKH DGKHVLRQRIIRUHLJQPDWWHUDQGGDPDJHGXHWRHOHFWURVWDWLF GLVFKDUJH 20521RIIHUVDKLJKSHUIRUPDQFHUHOLDEOHDQGUHDVRQDEO\ SULFHGLRQL]DWLRQVROXWLRQWRDOOXVHUVILJKWLQJWKLVLQYLVLEOH ZDUDJDLQVWVWDWLFHOHFWULFLW\ in Fan Ionizers High-speed Ionization A Unique Structure Provides a Uniform Airflow The newly developed airflow control system (AFCS) structure optimally controls the airflow of the fan to efficiently carry the discharged ions to the target workpiece. This gives the ZJ-FA20 the highest ionization performance in its class. Even with the airflow at a low setting, ionization is completed in approximately 2 seconds. Small, light workpieces are not blown away by the airflow, and static electricity is effectively neutralized. Airflow Control System (AFCS) Conventional ZJ-FA20 The front louvers and internal structure keep the airflow uniform. The airflow is dispersed, lowering efficiency. Engineering Data Airflow vs. Ionization Time Ionization Area vs. Ionization Time 300 3 3s Adjustment dial setting 2.5 200 MIN:1 1s ZJ-FA20 100 2 Ionization time (s) 4s 2s 2 3 1.5 0 4 MAX: 5 1 -100 -200 0.5 0 0.5 0.8 1.0 1.3 Airflow (m/s) 1.5 Measurement Conditions Installation distance: 300 mm Ionization time: ±1,000 V to ±100 V Plate monitor: 150 X 150 mm, 20 pF 1.8 2.0 -300 0 (mm) 200 400 Distance direction Measurement Conditions Airflow: Max. Ionization time: ±1,000 V to ±100 V Plate monitor: 150 X 150 mm, 20 pF 600 800 (mm) rd in Fan Ionizers More Versatile Use Long-term Ionization Performance A built-in ion balance sensor constantly senses the ion condition, and a variable DC system maintains the optimal ion balance at all times. This provides a long-term, stable balance for reliable ionization. Variable DC System Ion balance sensor + Positive discharge voltage Discharge Voltage Time Time 0V 0V Senses the ion balance - Negative discharge voltage Increase The ion balance is sensed and the voltage applied to the discharger electrodes is varied to adjust the ion output. Clean and Easy Maintenance The ZJ-FA20 features a fully opening front cover. Removing it allows neat and thorough cleaning, without spreading dust and other particles around. The discharger electrodes can also be replaced for long-term operation. LED lamps show the ion-generating condition and indicate when cleaning is required. Cleaning the discharger electrodes Replacing the discharger electrodes A Variety of Installation Possibilities In addition to table-top or bench-top installation, the ZJ-FA20 can be easily mounted to an aluminum pipe. The angle can also be freely adjusted using the angle-adjustment knob and oblong stand. Easy-to-see lamps Ordering Information Ionizer Accessories (sold separafely) Model Model Replacement Filter ZJ-FA20 ZJ9-FL120N1 (set of 10) ZJ9-NDT06FN1 Replacement Discharger Electrode (set of 6) Ratings and Specifications AC Adapter Ionizer Item Model 100 to 240 VAC, 50/60 Hz Input voltage Power supply voltage 24 VDC (See note 1.) Current consumption 900 mA max. (input from included AC adapter) Discharge voltage (Provided: UIA336-24-JR01A-998 by UNIFIVE CO., LTD.) Item ZJ-FA20 AC240V: 115VA MAX Power consumption ±7 kV 240 VAC: 115 VA max. Variable DC Output voltage 24 VDC Airflow (m3/min.) 1.4 to 2.3 m3/min (typical) Output current 1.5 A max. Ionization time (See note 2.) 1.2 s (0.8 s with no Filter) Ambient temperature range Discharge method Ambient humidity range Ion balance (See note 2.) ±10 V max. Amount of generated ozone 0.01 ppm max. (measured at a distance of 50 mm from air outlet) High-voltage output lamp: ION (yellow), Cleaning lamp: CLEANING (orange), Power lamp: POWER (green) Indicators Approx. 175 g (excluding power cable) Weight 43.8 X 28 X 95.9 (W X D X H) mm Dimensions * If an additional AC adapter is required, please contact your OMRON sales representative Automatic ion balance adjustment, airflow adjustment, manual ion balance adjustment Main functions 0 to 40°C 35% to 85% (with no condensation) Ambient temperature range Operating and storage: 0 to 50°C (with no icing or condensation) Ambient humidity range Operating: 35% to 65%, storage: 35% to 85% (with no condensation) Approx. 2.0 kg Weight (packed state) Unit: ABS, Discharger: Tungsten, stand: SPCC Materials Instruction sheet, AC adapter, warning labels (2 types), FG connection cable (2 m) Accessories Note 1: Be sure to use the included AC adapter for Ionizer operation. Note 2: Typical default settings. Measurement location and conditions: Center of air outlet at a distance of 300 mm, with maximum fan speed Ionization time: The time required to lower the charge from ±1,000 V to ±100 V Ion balance measurement time: 10 s Dimensions (Unit: mm) 197.5 140 8.5 80 12 Mounting Hole Dimensions 5 220 ,M n ve Se 120 149 s 60° 200 120° 50±0.2 15±0.2 4 100±0.2 165 Rotation Range 60 75 ° 5d e, 5 . The 0° 5.5 ° 60 12 dia. 50 d 5.5 100 ia. ia. 60° 80 4HISDOCUMENTPROVIDESINFORMATIONMAINLYFORSELECTINGSUITABLEMODELS0LEASEREADTHE)NSTRUCTION3HEETCAREFULLYFORINFORMATIONTHATTHE USERMUSTUNDERSTANDANDACCEPTBEFOREPURCHASEINCLUDINGINFORMATIONONWARRANTYLIMITATIONSOFLIABILITYANDPRECAUTIONS /-2/.#ORPORATION )NDUSTRIAL!UTOMATION#OMPANY 3ENSING$EVICES$IVISION(1 !PPLICATION3ENSORS$IVISION 3HIOKOJI(ORIKAWA3HIMOGYOKU +YOTO*APAN 4EL&AX 2EGIONAL(EADQUARTERS /-2/.%52/0%"6 3ENSOR"USINESS5NIT #ARL"ENZ3TR$.UFRINGEN 'ERMANY 4EL&AX /-2/.%,%#42/.)#3,,# /NE#OMMERCE$RIVE3CHAUMBURG ),53! 4EL&AX !UTHORIZED$ISTRIBUTOR /-2/.!3)!0!#)&)#04%,4$ .O!!LEXANDRA2OAD,OBBY !LEXANDRA4ECHNOPARK3INGAPORE 4EL&AX /-2/.#().!#/,4$ 2OOM"ANKOF#HINA4OWER 9IN#HENG:HONG2OAD 0U$ONG.EW!REA3HANGHAI#HINA 4EL&AX /-2/.)NDUSTRIAL!UTOMATION'LOBALWWWIAOMRONCOM Ú/-2/.#ORPORATION!LL2IGHTS2ESERVED )NTHEINTERESTOFPRODUCTIMPROVEMENT SPECIFICATIONSARESUBJECTTOCHANGEWITHOUTNOTICE CSM_1_1_0409 0RINTEDIN*APAN #AT.O%% -#