Manual Control Class 11 - 3RV, SMF, MMS Wiring Diagrams Signaling Contact for Class 11 - 3RV Class 11 - 3RV Typical Wiring Diagrams—Class SMF 3RV1921-1M Typical Wiring Diagrams—MMS L3 L1 T1 L1 T2 L2 T2 L2 T3 L3 T3 L3 REV FWD COM L3 REVERSING SINGLE PHASE 3-LEAD REPULSION-INDUCTION MOTOR Reversing Manual Motor Starting Switch 2-Pole, 1-Phase L1 L3 T3 Pilot Lights (if used) T1 L1 T1 T2 L2 T2 L2 T3 L3 T3 L3 Motor Reversing Manual Starter 3-Pole, 3-Phase L1 Pilot Lights (if used) 2-SPEED 2-WINDING SINGLE PHASE MOTOR Motor LOW HIGH 2-Pole, 1-Phase with Pilot Lights 2-SPEED 2-WINDING WYE CONNECTED 3- PHASE MOTOR 3-Pole, 3-Phase 3-Pole Reversing Switches THREE PHASE MOTOR LINE AND MOTOR LEADS Line Meter L1 to L2 to L3 to T1 to T2 to T3 to L.H. UNIT _ _ _ T1 T2 T3 Pilot Light Leads to _ _ T1 T2 T3 R.H. UNIT L1 L2 L3 _ _ _ T1 T3 SINGLE PHASE CAPACITOR OR SPLIT PHASE MOTOR L.H. UNIT LINE AND MOTOR LEADS Line L1 to L2 to _ _ Meter T1 to T4 to T5 to T8 to T1 T3 L1 T2 Furnish Jumper L1 L2 _ _ _ _ L3 to _ _ Pilot Light Leads to T8 T4 Motor R.H. UNIT T2 T1 T3 T1 T5 SINGLE PHASE 4-LEAD REPULSION - INDUCTION MOTOR L.H. UNIT LINE AND MOTOR LEADS Line L1 to L2 to _ _ Meter T1 to T4 to T5 to T8 to T2 L3 T3 T1 Furnish Jumper L3 to _ _ Pilot Light Leads to T8 T1 R.H. UNIT L1 L2 _ _ _ _ T2 L1 T2 T5 T4 RUN START Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 17-143 CONTROL PRODUCTS T1 LOW T3 T1 L1 T3 L1 L2 L3 L2 LOW T12 T13 T1 T2 T3 T1 L1 Pilot Light (if used) Motor L1 HIGH 17 L3 T3 REV (R.H. UNIT) COM T1 L1 FWD (L.H. UNIT) HIGH T1 L2 REV T11 L1 FWD NEMA & General Purpose Control AC 2-Speed Manual Motor Starting Switches AC Reversing Manual Starter and Manual Motor Starting Switches Heavy Duty Motor Starters Class 14 Wiring Diagrams 3-Phase and Single Phase Magnetic Starters WIRING DIAGRAM NEMA 00 - 4 Three Phase Magnetic Starter, Size 00–4 TO PILOT CONTROL DEVICE TO SUPPLY L1 L2 L3 Single Phase Magnetic Starter, Size 00–1 ab WIRING DIAGRAM IF PROVIDED CONTROL FUSES (OPTIONAL) 1 3 IF PROVIDED V M B W 1 A T1 2 T2 ESP200 95 96 A3+ A4- XF T3 C 3 V W M 96 1 B T2 T1 2 X1 XF A1 ESP200 A3 95 96 97 98 A3+ A4- H2 C SEC 97 98 H3 X1 H2 SEC T1 MAY BE GROUNDED BY CUSTOMER 3 PHASE MAGNETIC STARTER SIZE 00 - 4 WIRING DIAGRAM NEMA Three Phase Magnetic Starter with DC Coil, Sizes 00–400 - 4 TO PILOT CONTROL DEVICE SEC FUSE H4 H3 X2 H1 MOTOR CONTROL TRANSFORMER (OPTIONAL) A SEC FUSE H4 CONTROL FUSES (OPTIONAL) 1 CONTROL TRANSFORMER (OPTIONAL) 96 NEMA 00 - 4 TO SUPPLY L1 L2 MAY BE GROUNDED BY CUSTOMER SINGLE PHASE MAGNETIC STARTER Solid State Overload 3-Phase Sizes SIZE 00 - 45-8 INCOMING LINE POWER WIRING: USE 75°C COPPER WIRE ONLY. TO SUPPLY L1 L2 L3 H1 T2 MOTOR X2 SIZE CT RATIO 5 300:5 6 600:5 7 750:5 8 1200:5 A B C CIRCUIT PROTECTIVE DEVICE (IF USED) CONTROL FUSES (OPTIONAL) NEMA & General Purpose Control 1 3 IF PROVIDED 2 V M T1 B W T2 T3 LATE BREAK CONTACT 1 96 CONTROL TRANSFORMER (OPTIONAL) XF C ESP200 X1 2CT "A" L1/1 SEC FUSE H4 X1 3 H2 H3 L2 A1 L3 "C " A2 REMOVE WIRE " C " IF THE CONTACTOR COIL IS TO OPERATE ON A VOLTAGE OTHER THAN LINE VOLTAGE OR ON A SEPARATE CONTROL SOURCE. CONTACTOR M 2 SEC 95 96 97 98 A3+ A4- NOTE A X2 "B " CURRENT TRANSFORMER H1 (WHEN USED, SEE TABLE) RELAY 1CT 17 MOTOR CONTROL PRODUCTS THREE PHASE MAGNETIC STARTER WITH D.C. COIL Ambient Compensated Single Phase Sizes 00-2 1/2 a Warning: The ESP200 Starter and Single Phase Motor must be wired as shown above. For L1, L2 do not use the middle terminal or hole. 17-144 X1 O.L. 96 T1 T2 T3 NOTES: A: 2CT IS LOCATED ON THE LINE SIDE OF CONTACTOR ON SIZE 7 STARTERS ONLY. Load Amps (FLA): Adjustment of the ESP200 solid state overload relay accommodates the single phase motor. Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog (IF USED) 3CT X1 95 Ambient Compensated 3-Phase Sizes 00-2 1/2 b Full 2CT X1 MAY BE GROUNDED BY CUSTOMER LOAD Ambient Compensated 3-Phase Sizes 3-4 Combination Heavy Duty Starters Class 17, 18 Wiring Diagrams 3-Phase WIRING DIAGRAM NEMA 00 - 4 Size 00–4 a TO PILOT CONTROL DEVICE TO SUPPLY L1 L2 L3 CONTROL FUSES (OPTIONAL) 1 3 V IF PROVIDED M B W 1 CONTROL TRANSFORMER (OPTIONAL) 96 A T1 2 95 96 T2 ESP200 A3+ A4- XF T3 C SEC FUSE H4 X1 H2 SEC 97 98 H3 X2 H1 MOTOR MAY BE GROUNDED BY CUSTOMER 3 PHASE MAGNETIC STARTER SIZE 00 - 4 NEMA & General Purpose Control Size 5–8 b SIZE CT RATIO 5 300:5 6 600:5 7 750:5 8 1200:5 “C” CONTROL PRODUCTS wire “C” if control transformer is used. For separate control voltage source, remove jumpers “A” and “B” and connect source to control fuse line terminals. 17 aR emove b Remove wire “C” if the contactor coil is to operate on a voltage other than line voltage or in a separate control source. Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 17-145 O.L. RELAY CURRENT TRANSFORMER (SEE TABLE) Reversing Heavy Duty Starters Class 22 REMOVE WIRE "C" IF THE CONTACTOR COIL IS TO OPERATE ON A VOLTAGE OTHER THAN LINE VOLTAGE OR ON A SEPARATE CONTROL SOURCE. MOTOR Wiring Diagrams 3-Phase Ambient Compensated Overload Bimetal Overload Sizes 0-1 3/4 Bimetal Overload Sizes 2-2 1/2 Single Phase Ambient Compensated Overload CONTROL PRODUCTS 17 NEMA & General Purpose Control 3-Wire, 2-Pole Sizes 0-1 3/4 17-146 Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog Bimetal Overload Sizes 3-4 Reversing Heavy Duty Starters Class 22 Wiring Diagrams 3-Phase Solid State Overload 3-Phase Reversing Magnetic Starter 3 WIRING ⁄4 DIAGRAM Sizes 00–1 3-Phase Reversing Magnetic Starter Sizes 2–4DIAGRAM WIRING NEMA 00 - 1 3 4 NEMA 2 - 4 TO SUPPLY TO SUPPLY L3 L1 L2 L3 L2 L1 CONTROL FUSES (OPTIONAL) 3 5 V FOR 7 W 6 1 V REV W CONTROL FUSES (OPTIONAL) 4 ESP200 A 95 96 97 98 A3+ A4- XF B C SEC FUSE H4 2 7 96 CONTROL TRANSFORMER (OPTIONAL) 1 W REV 4 6 XF C T3 T2 T1 V H3 B A MAY BE GROUNDED BY CUSTOMER X2 MOTOR 3 PHASE REVERSING MAGNETIC STARTER MAGNETIC STARTER TO SUPPLY L1 L2 X2 H1 ESP200 95 96 97 98 A3+ A4- MAY BE GROUNDED BY CUSTOMER Solid State Overload 3 PHASE REVERSING Sizes 5–6 X1 SEC H3 H1 T1 MOTOR T3 SEC FUSE H4 H2 X1 SEC T2 W FOR H2 T3 T2 T1 V CONTROL TRANSFORMER (OPTIONAL) 96 1 2 5 3 1 L3 NEMA & General Purpose Control "REV" CONTACTOR "FWD" "FWD" CONTACTOR CONTRACTOR MECHANICAL INTERLOCK O.L. RELAY CURRENT TRANSFORMER (SEE TABLE) 17 REMOVE WIRE "C" IF THE CONTACTOR COIL IS TO OPERATE ON A VOLTAGE OTHER THAN LINE VOLTAGE OR ON A SEPARATE CONTROL SOURCE. CONTROL PRODUCTS MOTOR 3-Phase Reversing Magnetic Starter with DC Coil,WIRING SizesDIAGRAM 00–13⁄4 3-Phase Reversing Magnetic Starter with DC Coil, Sizes 2–4 NEMA 00 - 1 3 4 L1 1 3 7 V FOR W 5 V REV T3 T2 T1 W 6 96 CONTROL TRANSFORMER (OPTIONAL) SEC FUSE XF H4 X1 4 ESP200 95 96 97 98 A3+ A4- LATE BREAK B C H2 SEC T2 T1 MOTOR L2 NEMA 2 - 4 L3 5 3 CONTROL FUSES (OPTIONAL) 1 2 WIRING DIAGRAM TO SUPPLY TO SUPPLY L2 L3 L1 H3 V REV 4 6 ESP200 95 96 97 98 A3+ A4- T1 T2 XF T3 T2 T1 MOTOR 1 96 C SEC FUSE H4 H2 H3 T3 CONTROL FUSES (OPTIONAL) B W L.B. X2 MAY BE GROUNDED BY CUSTOMER 3 PHASE REVERSING MAGNETIC STARTER W/DC COIL V L.B. H1 T3 W FOR 2 7 X1 CONTROL TRANSFORMER SEC (OPTIONAL) X2 H1 MAY BE GROUNDED BY CUSTOMER 3 PHASE REVERSING MAGNETIC STARTER W/DC Siemens Industry, Inc. SPEEDFAX™ 2011 COIL Product Catalog 17-147 Combination Reversing Heavy Duty Starters Class 25, 26 Wiring Diagrams 3-Phase 3-Phase Reversing Magnetic Starter 3 WIRING00–1 DIAGRAM NEMA 00 - 1 3 4 ⁄4 Sizes 3-Phase Reversing Magnetic Starter Sizes 2–4 NEMA 2 - 4 WIRING DIAGRAM TO SUPPLY L3 L1 L2 TO SUPPLY L3 L2 L1 CONTROL FUSES (OPTIONAL) 3 5 V FOR 7 W 6 1 V REV W CONTROL FUSES (OPTIONAL) 4 ESP200 95 96 97 98 A3+ A4- A XF B C T1 T2 T3 V CONTROL TRANSFORMER (OPTIONAL) 96 1 2 SEC FUSE H4 FOR T1 T2 V 2 7 XF C T3 A B MOTOR 3 PHASE REVERSING MAGNETIC STARTER L2 3 PHASE REVERSING MAGNETIC STARTER Size 5–6 L3 "REV" CONTACTOR "FWD" "FWD" CONTACTOR CONTRACTOR 17 MECHANICAL CONTROL PRODUCTS INTERLOCK O.L. RELAY CURRENT TRANSFORMER (SEE TABLE) REMOVE WIRE "C" IF THE CONTACTOR COIL IS TO OPERATE ON A VOLTAGE OTHER THAN LINE VOLTAGE OR ON A SEPARATE CONTROL SOURCE. MOTOR Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog X1 H2 X2 H1 ESP200 X2 TO SUPPLY SEC FUSE H4 SEC 95 96 97 98 A3+ A4- MAY BE GROUNDED BY CUSTOMER L1 96 CONTROL TRANSFORMER (OPTIONAL) 1 W 4 6 H1 T1 MOTOR T3 17-148 REV H3 H2 H3 W X1 SEC T2 NEMA & General Purpose Control 5 3 1 MAY BE GROUNDED BY CUSTOMER Two Speed Heavy Duty Starters Class 30 & 32 Non-Combination and Combination Starters Wiring Diagrams 1 Winding Constant Horsepower Size 0–13/4 ELEMENTARY DIAGRAM TO SUPPLY L1 L2 DISCONNECT or CIRCUIT BREAKER DISCONNECT or CIRCUIT BREAKER HIGH OL HIGH HIGH LOW HIGH LOW 5 T6 T4 T4 T2 LOW T3 V LOW W T1 T5 6 5 95 2 T2 CONSTANT HORSEPOWER MOTOR 3 6 LOW HIGH 5 4 B 8 7 73 V LOW W 1 96 CONTROL TRANSFORMER (OPTIONAL) V HIGH W T6 7 HIGH LOW 2 ESP200 95 96 97 98 A OVERLOAD A3+ RELAY A495 96 HIGH C 1 96 2 4 ALL OL'S 96 6 CONTROL FUSES (OPTIONAL) 1 V HIGH W 4 T3 T1 OL LOW LOW B A 3 8 T5 LOW A NEMA 00 - 1 3 4 WIRING DIAGRAM WIRING DIAGRAM SUPPLY TOTOSUPPLY L1L1 L2L2 L3L3 L3 8 T1 T2 T1 T2 X1 OVERLOAD RELAY A3+ A495 96 T3 T3 SEC FUSE CONTROL FUSES XF (OPTIONAL) H4 ESP200 95 96 97 98 T6 T6 T4 T4 C H2 CONTROL TRANSFORMER SEC (OPTIONAL) SEC FUSE H3 X2 XF H4 X1 T5 T5 H1 LOW H2 T1 T2T1 T3T2 T4T3 MOTOR M T5T4 T6T5 POSITION L1 L2 L3 TOGETHER LOW SPEED T1 T2 T3 T4 T5 T6 HIGH SPEED T6 T4 T5 SEC MAY BE GROUNDED BY X2 CUSTOMER H3 H1 T6 2 SPEED 3 PHASE 1 WINDING CONSTANT HORSEPOWER 1 Winding Constant Horsepower Size 2–4 NEMA 2 - 4 WIRING DIAGRAM TO SUPPLY L1 L2 L3 1 V LOW W CONTROL FUSES (OPTIONAL) 3 6 VHIGHW V L W 4 2 6 A 96 T4 T5 XF ESP200 95 96 97 98 A3+ A4- T2 1 CONTROL TRANSFORMER (OPTIONAL) T6 T1 B 7 ESP200 95 96 97 98 NEMA & General Purpose Control 5 C A3+ A4- SEC FUSE H4 X1 H2 SEC T3 H3 X2 H1 17 MAY BE GROUNDED BY CUSTOMER MOTOR CONTROL PRODUCTS T1 T2 T3 T4 T5 T6 2 SPEED 3 PHASE 1 WINDING CONSTANT HORSEPOWER 1 Winding Constant or Variable Torque Size 0–13/4 ELEMENTARY DIAGRAM TO SUPPLY L1 L2 DISCONNECT or CIRCUIT BREAKER LOW LOW HIGH HIGH HIGH ALL OL'S T3 T4 HIGH 96 T2 T6 OL HIGH HIGH A T1 T5 95 2 4 POSITION L1 L2 L3 TOGETHER LOW SPEED T1 T2 T3 HIGH SPEED T6 T4 T5 T1 T2 T3 LOW HIGH 5 T3 T1 T2 T5 T6 VARIABLE TORQUE MOTOR 3 HIGH 6 5 LOW 7 3 8 T1 T2 T5 T6 CONSTANT TORQUE MOTOR T4 T3 NEMA 00 - 1 3 4 DISCONNECT or CIRCUIT BREAKER T4 OL LOW LOW WIRING DIAGRAM WIRING DIAGRAM TO SUPPLY TO SUPPLY L1 L1 L2 L2 L3 L3 L3 LOW HIGH 8 V HIGH W 7 73 V HIGH W 4 2 ESP200 95 96 RELAY 97 98 OVERLOAD 95 CONTROL FUSES (OPTIONAL) V LOW W 4 6 5 6 B A 1 A A3+ A496 B 8 V LOW W C 1 96 2 ESP200 95 96 97 98 OVERLOAD RELAY 95 A3+ A4- 96 T1 T1T2 T2 T6T6 T4T4 T5T5 T1 T1 T2 T2 T3 T3 MOTOR T4 T4 M T5 T5 T6 T6 1 T3 T3 96 CONTROL TRANSFORMER (OPTIONAL) CONTROL SEC FUSESFUSE (OPTIONAL) XF H4 X1 C H2TRANSFORMER CONTROL (OPTIONAL) SEC SEC FUSE H3 XF X2 H4 X1 H2 H1 SEC MAY BE H3 X2 GROUNDED BY H1 CUSTOMER 2 SPEED 3 PHASE 1 WINDING CONSTANT OR VARIABLE TORQUE Note: For separate control voltage source, remove jumpers “A” and “B” and connect source to control fuse terminal. Remove jumper “C” if control transformer is used. Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 17-149 Two Speed Heavy Duty Starters Class 30 & 32 Non-Combination and Combination Starters Wiring Diagrams 1 Winding Constant or Variable Torque Size 2–4 ELEMENTARY DIAGRAM TO SUPPLY L1 L2 L3 DISCONNECT or CIRCUIT BREAKER LOW H H LOW H HIGH T3 6 LOW 5 LOW 7 4 HIGH H LOW V LOW W ESP200 95 96 97 98 A3+ A4- A3+ A4- T6 T4 T2 T3 C H4 X1 H2 SEC H3 X2 V HI W H1 T6 T4 4 SEC FUSE XF T5 5 HIGH 96 CONTROL TRANSFORMER (OPTIONAL) T1 ESP200 95 96 97 98 H 1 7 A 8 B V H W T1 T2 2T3 OVERLOAD RELAY 95 96 POSITION L1 L2 L3 TOGETHER LOW SPEED T1 T2 T3 HIGH SPEED T6 T4 T5 T1 T2 T3 NEMA & General Purpose Control 6 3 6 CONTROL FUSES (OPTIONAL) 3 8 V H W 1 2 7 4 T2 T5 T6 VARIABLE TORQUE MOTOR 3 HIGH H 2 V LO W T1 T3 5 V HIGHW T4 T5 95 1 T2 T5 T6 CONSTANT TORQUE MOTOR ALL OL'S 96 T1 T3 T2 T4 HIGH A B T1 T6 OL HIGH HIGH NEMA 2 - 4 WIRING DIAGRAM WIRING DIAGRAM CIRCUIT BREAKER T4 OL LOW LOW A TO SUPPLY L1 L2 L3 TO SUPPLY L1 L2 L3 DISCONNECT or T5 T1 T2 T3 T4 T5 T6 OVERLOAD RELAY 95 96 CONTROL FUSES (OPTIONAL) 1 96 C MOTOR H2 T1 T2 T3 T4 T5 T6 MAY BE GROUNDED BY CUSTOMER SEC FUSE XF H4 X1 SEC H3 2 SPEED 3 PHASE 1X2 WINDING MOTOR H1 CONSTANT OR VARIABLE TORQUE D68784002 CONTROL TRANSFORMER (OPTIONAL) 2 Winding Constant Horsepower & 2 Winding Constant or Variable Torque Size 0–4 17 TO SUPPLY L1 L2 L3 CONTROL PRODUCTS L3 WIRING DIAGRAM DISCONNECT or CIRCUIT BREAKER DISCONNECT or CIRCUIT BREAKER LOW LOW HIGH HIGH POSITION L1 L2 L3 LOW SPEED T1 T2 T3 HIGH SPEED T11 T12 T13 V HI 2 T3 T12 W B 4 8 5 6 V HIGH W 37 V LOW W T12 T13 ALL OL'S 95 V LO W T1 1 96 T11 OL HIGH HIGH 96 CONTROL FUSES (OPTIONAL) B A 1 8 T2 T3 5 3 T2 T1 OL LOW LOW A L2 TO SUPPLY L1 L2 L3 NEMA 2 - 4 WIRING DIAGRAM TO SUPPLY L1 ELEMENTARY DIAGRAM 2 6 T1 T2 T3 ESP200 OVERLOAD RELAY 95 96 97 98 95 96 T11 T13 TWO WINDING MOTOR 7 A A3+ A4- 5 LOW 6 4 HIGH 3 HIGH 7 2 LOW HIGH 4 SEC FUSE C 1 96 CONTROL FUSES XF (OPTIONAL) H4 T11 T12 T13 ESP200 OVERLOAD RELAY 95 96 97 98 95 96 CONTROLCTRANSFORMER H2 (OPTIONAL) A3+ A4- 8 T1 T2 T3 LOW T11 T1 T2 T1 T3 T11 T2 T12 T3 T13 T11 T12 T13 T12 T13 XF SEC FUSE H3 H4 X1 H2 M MOTOR CONTROL TRANSFORMER (OPTIONAL) H3 H1 SEC X1 SEC X2 H1 X2 MAY BE GROUNDED BY CUSTOMER 2 SPEED 3 PHASE 2 WINDING SEPARATE WINDING D68786001 Note: For separate control voltage source, remove jumpers “A” and “B” and connect source to control fuse terminal. Remove jumper “C” if control transformer is used. 17-150 Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog Reduced Voltage Starters & Pump Panels Class 36, 37, 88 Wiring Diagrams Part Winding NEMA & General Purpose Control 17 CONTROL PRODUCTS EMT Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 17-151 Reduced Voltage Starters & Pump Panels Class 36, 37, 88 Wiring Diagrams Auto Transformer TO SUPPLY L1 L2 L3 SEK SES SAW LMB SEK SES SAW LMB SEK SES SAW LMB OPTIONAL DISCONNECT OR CIRCUIT BREAKER OL 1S 3L1 0% 50% 1L1 R 65% 1CT 80% 2S L2 L3 100% L1 T1 2L1 OL 0% 50% 65% 80% R 1S 3L2 1L2 100% 2S 2CT * T2 2L2 FOR MOTOR HP SEE CONTROLLER NAMEPLATE MOTOR OL 4FU 71 MR 73 1S 0% 50% 65% 3L3 80% R FOR STARTER SIZES 1-4, 1CT-3CT ARE NOT USED. L1 1L3 100% 2S 3CT T3 2L3 1S 74 (A1) R 75 (A2) 2S 76 MR 5FU 72 L2 2S 77 CR1 L1 JUMPER 1FU 12 TAS 1 2FU 78 (A1) * 1S 79 H1 (A1) H4 (A2) 1S MECH INTLK (A2) R 3FU L2 CPT X2 X1 CONNECT VOLTAGE AS SPECIFIED PER NAMEPLATE NOTE E 17 2 3 2 LMB SAW SES SEK 1 X2 TR SUPPLIED AS REQUIRED 3 (A1) LMB SAW SES SEK NEMA & General Purpose Control CR1 MR (A2) 4 (95) OL (96) 3 MR TR 6 (A1) CR1 (A2) CONTROL PRODUCTS NOTC CONNECTIONS FOR OPTIONAL DEVICES Note E: Remove jumper if thermal protection switch is provided. HAND * 3 1PB OFF AUTO (A1) (A2) 2PB (A1) START CR2 (A2) 3 2 2PB 1SS HAND 1 2 1 1 * SURGE SUPPRESSOR START STOP 1 OFF * 5 AUTO CONTACT 3 1 RUN/ON/ RUNNING 3 3 1SS * 5 OFF 1 AUTO CONTACT 4 ETM AUTO 4 1LT OL OL TRIPPED 9 X2 MR OFF/STOP 10 X2 1 4LT ON 1SS * 3 1 5LT OPTIONAL DEVICES ARE FURNISHED PER CONTRACT DOCUMENTS 17-152 Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog Reduced Voltage Starters & Pump Panels Class 36, 37, 88 Wiring Diagrams Wye Delta (Open Transition) TO SUPPLY L1 L2 L3 OPTIONAL DISCONNECT OR CIRCUIT BREAKER OL 1L1 1M T1 2M T6 1M T2 T1 1CT T6 OL 1L2 S 2CT 2M T1 T6 T2 S S T3 T4 T4 S T4 T5 T5 OL 1M 1L3 T2 T3 T3 3CT 2M T5 FOR STARTER SIZES 1-4, 1CT-3CT ARE NOT USED. 1L1 1L2 4FU 50 MR 2M 51 S CR1 52 53 S 56 (A1) 57 1M 54 (A2) S MR * (A1) 5FU MECH (A2) 2M (A1) 55 INTERLOCK (A2) NEMA & General Purpose Control 1M SUPPLIED AS REQUIRED 3FU 2FU H1 1FU 1 H3 H2 H4 CPT 1X1 X2 X1 CONNECT VOLTAGE AS SPECIFIED PER NAMEPLATE X2 TR 1 2 3 2 MR (A1) 4 (A2) MR TR 3 (95) OL (A1) 6 X2 (96) (A2) 17 CR1 NCTO CONTROL PRODUCTS CONNECTIONS FOR OPTIONAL DEVICES 2 3 CR2 (A2) 3 2PB 1 1SS HAND * (A2) (A1) START 2 1 (A1) 2PB 1PB OFF HAND AUTO * SURGE SUPPRESSOR START STOP 1 OFF * 5 AUTO CONTACT 3 1 4 ETM AUTO RUN/ON/ RUNNING 3 3 4 1LT AUTO 1 1SS * 5 CONTACT OFF 1 OL OL TRIPPED 9 X2 MR OFF/STOP 10 X2 1 4LT ON 1SS * 3 1 5LT OPTIONAL DEVICES ARE FURNISHED PER CONTRACT DOCUMENTS Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 17-153 Reduced Voltage Starters & Pump Panels Class 36, 37, 88 Wiring Diagrams Wye Delta (Closed Transition) TO SUPPLY L1 L2 L3 OPTIONAL DISCONNECT OR CIRCUIT BREAKER OL 1M T1 T1 1CT 1L1 3L1 RES A 1A 2M T6 OL 1M 1L2 2CT 3L2 RES B T1 T6 T2 T2 S 1A 2M S S T3 T4 S T4 T5 T5 OL 1L3 1M T3 T3 3CT 3L3 RES C 2M T2 1A FOR STARTER SIZES 1-4, 1CT-3CT ARE NOT USED. 1L2 1L1 4FU 50 MR 2M 51 CR1 52 53 1A NEMA & General Purpose Control S S 57 (A1) 1A 56 (A1) 58 (A1) (A2) MR 54 2M (A1) 5FU (A2) S * 1M 55 1M MECH (A2) INTERLOCK (A2) SUPPLIED AS REQUIRED 3FU 2FU H1 1FU 1 H3 H2 H4 CPT 1X1 X1 X2 TR 6 CONNECT VOLTAGE AS SPECIFIED PER NAMEPLATE X2 (A1) (A2) CR1 NCTO TR 17 1 3 2 CONTROL PRODUCTS 2 MR (A1) MR 4 (A2) OL (95) (96) X2 3 CONNECTIONS FOR OPTIONAL DEVICES 2 3 1PB OFF HAND AUTO * (A2) START (A1) CR2 (A2) 3 2PB 1SS HAND 1 (A1) 2PB 2 1 1 * SURGE SUPPRESSOR START STOP 1 OFF * 5 AUTO CONTACT 3 1 RUN/ON/ RUNNING 3 3 1SS * 5 OFF 1 AUTO CONTACT 4 ETM AUTO 4 1LT OL OL TRIPPED 9 X2 MR OFF/STOP 10 X2 1 4LT ON 1SS * 3 1 5LT OPTIONAL DEVICES ARE FURNISHED PER CONTRACT DOCUMENTS 17-154 Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog Heavy Duty Contactors and Reversing Contactors Class 40, 43 Wiring Diagrams 3-Phase Magnetic Contactors and Reversing Contactors 3-Phase Contactors—Size 00–4 3-Phase Reversing Contactors—Size 00–4 3-Phase Contactors—Size 5, 6 3-Phase Reversing Contactors—Size 5, 6 TO SUPPLY L1 L2 L3 "REV" CONTACTOR "FWD" "FWD" CONTACTOR CONTRACTOR MECHANICAL NEMA & General Purpose Control INTERLOCK RELAY CURRENT TRANSFORMER REMOVE WIRE "C" IF THE CONTACTOR COIL IS TO OPERATE ON A VOLTAGE OTHER THAN LINE VOLTAGE OR ON A SEPARATE CONTROL SOURCE. 17 LOAD CONTROL PRODUCTS Single Phase Magnetic Contactors and Reversing Contactors Single Phase Contactors—Size 00–4 Single Phase Reversing Contactors—Size 00–1P Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 17-155 Duplex Heavy Duty Controllers Class 83, 84 CONTROL PRODUCTS 17 NEMA & General Purpose Control Standard Duplex Pump Panel (92) 17-156 Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog Wiring Diagrams Duplex Panel w/o alternator (95) Duplex Heavy Duty Controllers Class 83, 84 Duplex Panel with Relay Alternation (93) Wiring Diagrams Duplex Panel with Lead Pump Transfer Switch (94) NEMA & General Purpose Control 17 CONTROL PRODUCTS Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 17-157 Standard & Irrigation Pump Panels Class 87 CONTROL PRODUCTS 17 NEMA & General Purpose Control Standard Class 87 Pump Panel 17-158 Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog Wiring Diagrams Lighting and Heating Contactors Electrically Held, Class LE Wiring Diagrams 20 AMP 30 – 100 AMP NEMA & General Purpose Control 17 CONTROL PRODUCTS 200 – 400 AMP Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 17-159 Lighting and Heating Contactors Mechanically Latched 20 Amp, Class CLM ON Wiring Diagrams OFF CONTACTOR CONTROL VOLTAGE L OFF L ON C COMMON OR SEPARATE CONTROL LINES 5 ON 2 CR1 3 CR2 L CR2 CR1 0 CR1 CR2 C ON 0 OFF CONTROL MODULE VOLTAGE OFF 4 TYPICAL OFF-ON SELECTOR SWITCH COIL PILOT LIGHTS REQUIRE (1) EA. CLM4097291 AUXILIARY CONTACT KIT. 3 WIRE CONTROL ACC. 48 ON CONTACTOR CONTROL VOLTAGE HAND OFF AUTO OFF 5 CONTROL MODULE VOLTAGE CR CR 4 3 OFF L CR 3 COIL REMOTE CONTROL 2 CONTROL MODULE VOLTAGE CR1 CR2 CONNECTIONS TO CONTROL MODULES OFF 1 L NEMA & General Purpose Control CR C 3 CR 4 MODULE TERMINAL L ON-OFF CONTROL MODULE VOLTAGE COIL ON 2 WIRE CONTROL ACC. 47 CONNECT TO: NOT USED 2 CONT. STATION FOR ACC. 48 & 49 3 CONT. STATION FOR ACC. 47,48 & 49 4 MODULE CONTROL VOLTAGE * 5 CONTACTOR CONTROL VOLTAGE O " CONTACTOR " TERMINAL O ON C " CONTACTOR " TERMINAL C ON CONTROL PRODUCTS 17 * FOR 24 VDC CONTROL MODULES CONNECT TERMINAL 4 TO NEGATIVE (-) 17-160 CR1 C ON-OFF (FORM 3) CONTROL ACC. 49 CONTACTOR CONTROL VOLTAGE 0 0 COIL ON ON CR L CR1 4 2 WIRE CONTROL ACC. 47 5 OFF 5 CR2 0 C L CONTACTOR CONTROL VOLTAGE L Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog Lighting and Heating Contactors Mechanically Latched 30–400 Amps, Class CLM Mechanically Latched, CLM 30–200 Wiring Diagrams Ampsa Connection for 2-Wire Control CLMOC, CLMOD, CLMOE, and CLMOF Connection for Hand/Off/Auto Control CLMOC, CLMOD, CLMOE, and CLMOF NEMA & General Purpose Control Connection Diagram for Common/Separate Control with Momentary Pushbutton or ON-OFF Selector Switch CLMOC, CLMOD, CLMOE, and CLMOF Mechanically Latched Type CLM 300 and 400 Ampa 17 CONTROL PRODUCTS Connection Diagram for Common/Separate Control with Momentary Pushbutton or ON-OFF Selector Switch CLMOG and CLMOH Connection for 2-Wire Control CLMOG and CLMOH Connection for Hand/Off/Auto Control CLMOG and CLMOH a Control relay is required for 2-wire and Hand/Off/Auto Control, as shown in diagram. Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 17-161 Industrial Control Power Transformers Class MT, MTG Voltage Letter Aac When secondary fuse clips are installed, Terminal X1 becomes XF Voltage Letter Db CONTROL PRODUCTS 17 NEMA & General Purpose Control Wiring Diagrams Voltage Letter B bc When secondary fuse clips are installed, Terminal X1 becomes XF Voltage Letter E ac Voltage Letter C bc When secondary fuse clips are installed, Terminal X1 becomes XF Voltage Letter Fa When secondary fuse clips are installed, Terminal X1 becomes XF When secondary fuse clips are installed, Terminal X1 becomes XF When secondary fuse clips are installed, Terminal X1 becomes XF Voltage Letter Ga Voltage Letter H Voltage Letter I When secondary fuse clips are installed, Terminal X1 becomes XF Does not include secondary fuse clips Does not include secondary fuse clips Voltage Letter J bc Voltage Letter L When secondary fuse clips are installed, Terminal X3 becomes XF Does not include secondary fuse clips H1 a b c Includes secondary fuse clips on sizes 50-750VA Includes secondary fuse clips on sizes 50-500VA Secondary fuse clips are not included on MTG transformers. 17-162 X2 Voltage Letter P 380V 24V H2 X1 Does not include secondary fuse clips Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog Voltage Letter Ma When secondary fuse clips are installed, Terminal X1 becomes XF