Wiring Diagrams

Manual Control
Class 11 - 3RV, SMF, MMS
Wiring Diagrams
Signaling Contact for Class 11 - 3RV
Class 11 - 3RV
Typical Wiring Diagrams—Class SMF
3RV1921-1M
Typical Wiring Diagrams—MMS
L3
L1
T1
L1
T2
L2
T2
L2
T3
L3
T3
L3
REV
FWD
COM
L3
REVERSING
SINGLE PHASE
3-LEAD
REPULSION-INDUCTION
MOTOR
Reversing Manual Motor
Starting Switch 2-Pole, 1-Phase
L1
L3
T3
Pilot Lights
(if used)
T1
L1
T1
T2
L2
T2
L2
T3
L3
T3
L3
Motor
Reversing Manual Starter 3-Pole, 3-Phase
L1
Pilot Lights
(if used)
2-SPEED
2-WINDING
SINGLE PHASE
MOTOR
Motor
LOW
HIGH
2-Pole, 1-Phase with
Pilot Lights
2-SPEED
2-WINDING WYE CONNECTED
3- PHASE
MOTOR
3-Pole, 3-Phase
3-Pole Reversing Switches
THREE PHASE MOTOR
LINE AND
MOTOR LEADS
Line
Meter
L1 to
L2 to
L3 to
T1 to
T2 to
T3 to
L.H.
UNIT
_
_
_
T1
T2
T3
Pilot Light
Leads to
_
_
T1 T2 T3
R.H.
UNIT
L1
L2
L3
_
_
_
T1
T3
SINGLE PHASE CAPACITOR
OR SPLIT PHASE MOTOR
L.H.
UNIT
LINE AND
MOTOR LEADS
Line
L1 to
L2 to
_
_
Meter
T1 to
T4 to
T5 to
T8 to
T1
T3
L1
T2
Furnish Jumper
L1
L2
_
_
_
_
L3 to
_
_
Pilot Light
Leads to
T8 T4
Motor
R.H.
UNIT
T2
T1
T3
T1 T5
SINGLE PHASE 4-LEAD
REPULSION - INDUCTION MOTOR
L.H.
UNIT
LINE AND
MOTOR LEADS
Line
L1 to
L2 to
_
_
Meter
T1 to
T4 to
T5 to
T8 to
T2
L3
T3
T1
Furnish Jumper
L3 to
_
_
Pilot Light
Leads to
T8
T1
R.H.
UNIT
L1
L2
_
_
_
_
T2
L1
T2
T5 T4
RUN
START
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
17-143
CONTROL
PRODUCTS
T1
LOW
T3
T1
L1
T3
L1 L2 L3
L2
LOW
T12
T13
T1
T2
T3
T1
L1
Pilot Light
(if used)
Motor
L1
HIGH
17
L3
T3
REV
(R.H. UNIT)
COM
T1
L1
FWD
(L.H. UNIT)
HIGH
T1
L2
REV
T11
L1
FWD
NEMA & General
Purpose Control
AC 2-Speed Manual Motor Starting Switches
AC Reversing Manual Starter and Manual Motor Starting Switches
Heavy Duty Motor Starters
Class 14
Wiring Diagrams
3-Phase and Single Phase Magnetic Starters
WIRING DIAGRAM
NEMA 00 - 4
Three Phase Magnetic Starter, Size 00–4
TO PILOT
CONTROL DEVICE
TO SUPPLY
L1
L2
L3
Single Phase Magnetic
Starter,
Size 00–1 ab
WIRING
DIAGRAM
IF PROVIDED
CONTROL FUSES
(OPTIONAL)
1
3
IF PROVIDED
V
M
B
W
1
A
T1
2
T2
ESP200
95 96
A3+ A4-
XF
T3
C
3
V
W
M
96
1
B
T2
T1
2
X1
XF
A1 ESP200 A3
95 96
97 98
A3+ A4-
H2
C
SEC
97 98
H3
X1
H2
SEC
T1
MAY BE
GROUNDED BY
CUSTOMER
3 PHASE MAGNETIC STARTER
SIZE 00 - 4
WIRING DIAGRAM
NEMA
Three
Phase Magnetic Starter with DC Coil, Sizes
00–400 - 4
TO PILOT
CONTROL DEVICE
SEC FUSE
H4
H3
X2
H1
MOTOR
CONTROL
TRANSFORMER
(OPTIONAL)
A
SEC FUSE
H4
CONTROL FUSES
(OPTIONAL)
1
CONTROL
TRANSFORMER
(OPTIONAL)
96
NEMA 00 - 4
TO SUPPLY
L1
L2
MAY BE
GROUNDED BY
CUSTOMER
SINGLE PHASE MAGNETIC STARTER
Solid State Overload 3-Phase
Sizes
SIZE 00
- 45-8
INCOMING LINE
POWER WIRING:
USE 75°C COPPER WIRE ONLY.
TO SUPPLY
L1
L2
L3
H1
T2
MOTOR
X2
SIZE
CT RATIO
5
300:5
6
600:5
7
750:5
8
1200:5
A
B
C
CIRCUIT
PROTECTIVE
DEVICE
(IF USED)
CONTROL FUSES
(OPTIONAL)
NEMA & General
Purpose Control
1
3
IF PROVIDED
2
V
M
T1
B
W
T2
T3
LATE
BREAK
CONTACT
1
96 CONTROL
TRANSFORMER
(OPTIONAL)
XF
C
ESP200
X1
2CT
"A"
L1/1
SEC FUSE
H4
X1
3
H2
H3
L2
A1
L3
"C "
A2
REMOVE WIRE " C " IF THE CONTACTOR
COIL IS TO OPERATE ON A VOLTAGE
OTHER THAN LINE VOLTAGE OR ON A
SEPARATE CONTROL SOURCE.
CONTACTOR
M
2
SEC
95 96
97 98
A3+ A4-
NOTE A
X2
"B "
CURRENT
TRANSFORMER
H1
(WHEN USED, SEE TABLE)
RELAY
1CT
17
MOTOR
CONTROL
PRODUCTS
THREE PHASE MAGNETIC STARTER
WITH D.C. COIL
Ambient Compensated
Single Phase Sizes 00-2 1/2
a Warning:
The ESP200 Starter and Single Phase Motor
must be wired as shown above. For L1, L2 do not use
the middle terminal or hole.
17-144
X1
O.L.
96
T1
T2
T3
NOTES:
A: 2CT IS LOCATED ON THE LINE SIDE
OF CONTACTOR ON SIZE 7 STARTERS ONLY.
Load Amps (FLA): Adjustment of the ESP200 solid
state overload relay accommodates the single phase
motor.
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
(IF USED)
3CT
X1
95
Ambient Compensated
3-Phase Sizes 00-2 1/2
b Full
2CT
X1
MAY BE
GROUNDED BY
CUSTOMER
LOAD
Ambient Compensated
3-Phase Sizes 3-4
Combination Heavy Duty Starters
Class 17, 18
Wiring Diagrams
3-Phase
WIRING DIAGRAM
NEMA 00 - 4
Size 00–4 a
TO PILOT
CONTROL DEVICE
TO SUPPLY
L1
L2
L3
CONTROL FUSES
(OPTIONAL)
1
3
V
IF PROVIDED
M
B
W
1
CONTROL
TRANSFORMER
(OPTIONAL)
96
A
T1
2
95 96
T2
ESP200
A3+ A4-
XF
T3
C
SEC FUSE
H4
X1
H2
SEC
97 98
H3
X2
H1
MOTOR
MAY BE
GROUNDED BY
CUSTOMER
3 PHASE MAGNETIC STARTER
SIZE 00 - 4
NEMA & General
Purpose Control
Size 5–8 b
SIZE
CT RATIO
5
300:5
6
600:5
7
750:5
8
1200:5
“C”
CONTROL
PRODUCTS
wire “C” if control transformer is used. For
separate control voltage source, remove jumpers “A” and “B” and connect source to control fuse line
terminals.
17
aR
emove
b Remove
wire “C” if the contactor coil is to operate
on a voltage other than line voltage or in a separate control source.
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
17-145
O.L.
RELAY
CURRENT
TRANSFORMER
(SEE TABLE)
Reversing Heavy Duty Starters
Class 22
REMOVE WIRE "C" IF THE CONTACTOR
COIL IS TO OPERATE ON A VOLTAGE
OTHER THAN LINE VOLTAGE OR ON A
SEPARATE CONTROL SOURCE.
MOTOR
Wiring Diagrams
3-Phase Ambient Compensated Overload
Bimetal Overload
Sizes 0-1 3/4
Bimetal Overload
Sizes 2-2 1/2
Single Phase Ambient Compensated Overload
CONTROL
PRODUCTS
17
NEMA & General
Purpose Control
3-Wire, 2-Pole Sizes 0-1 3/4
17-146
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
Bimetal Overload
Sizes 3-4
Reversing Heavy Duty Starters
Class 22
Wiring Diagrams
3-Phase Solid State Overload
3-Phase Reversing Magnetic Starter
3
WIRING
⁄4 DIAGRAM
Sizes 00–1
3-Phase Reversing Magnetic Starter
Sizes
2–4DIAGRAM
WIRING
NEMA 00 - 1 3 4
NEMA 2 - 4
TO SUPPLY
TO SUPPLY
L3
L1 L2
L3
L2
L1
CONTROL FUSES
(OPTIONAL)
3
5
V
FOR
7
W
6
1
V REV W
CONTROL FUSES
(OPTIONAL)
4
ESP200
A
95 96
97 98
A3+ A4-
XF
B
C
SEC FUSE
H4
2
7
96 CONTROL
TRANSFORMER
(OPTIONAL)
1
W
REV
4
6
XF
C
T3
T2
T1
V
H3
B
A
MAY BE
GROUNDED BY
CUSTOMER
X2
MOTOR
3 PHASE REVERSING
MAGNETIC STARTER
MAGNETIC STARTER
TO SUPPLY
L1
L2
X2
H1
ESP200
95 96
97 98
A3+ A4-
MAY BE
GROUNDED BY
CUSTOMER
Solid State Overload
3 PHASE
REVERSING
Sizes 5–6
X1
SEC
H3
H1
T1 MOTOR T3
SEC FUSE
H4
H2
X1
SEC
T2
W
FOR
H2
T3
T2
T1
V
CONTROL
TRANSFORMER
(OPTIONAL)
96
1
2
5
3
1
L3
NEMA & General
Purpose Control
"REV"
CONTACTOR
"FWD"
"FWD"
CONTACTOR
CONTRACTOR
MECHANICAL
INTERLOCK
O.L.
RELAY
CURRENT
TRANSFORMER
(SEE TABLE)
17
REMOVE WIRE "C" IF THE CONTACTOR
COIL IS TO OPERATE ON A VOLTAGE
OTHER THAN LINE VOLTAGE OR ON A
SEPARATE CONTROL SOURCE.
CONTROL
PRODUCTS
MOTOR
3-Phase Reversing Magnetic Starter with DC Coil,WIRING
SizesDIAGRAM
00–13⁄4
3-Phase Reversing Magnetic Starter with DC Coil, Sizes 2–4
NEMA 00 - 1 3 4
L1
1
3
7
V
FOR
W
5
V
REV
T3
T2
T1
W
6
96 CONTROL
TRANSFORMER
(OPTIONAL)
SEC FUSE
XF
H4
X1
4
ESP200
95 96
97 98
A3+ A4-
LATE BREAK
B
C
H2
SEC
T2
T1
MOTOR
L2
NEMA 2 - 4
L3
5
3
CONTROL FUSES
(OPTIONAL)
1
2
WIRING DIAGRAM
TO SUPPLY
TO SUPPLY
L2
L3
L1
H3
V
REV
4
6
ESP200
95 96
97 98
A3+ A4-
T1
T2
XF
T3
T2
T1
MOTOR
1
96
C
SEC FUSE
H4
H2
H3
T3
CONTROL FUSES
(OPTIONAL)
B
W
L.B.
X2
MAY BE
GROUNDED BY
CUSTOMER
3 PHASE REVERSING
MAGNETIC STARTER W/DC COIL
V
L.B.
H1
T3
W
FOR
2
7
X1
CONTROL
TRANSFORMER
SEC (OPTIONAL)
X2
H1
MAY BE
GROUNDED BY
CUSTOMER
3 PHASE REVERSING
MAGNETIC
STARTER W/DC
Siemens Industry,
Inc. SPEEDFAX™
2011 COIL
Product Catalog
17-147
Combination Reversing Heavy Duty Starters
Class 25, 26
Wiring Diagrams
3-Phase
3-Phase Reversing Magnetic Starter
3
WIRING00–1
DIAGRAM
NEMA 00 - 1 3 4
⁄4
Sizes
3-Phase Reversing Magnetic Starter
Sizes 2–4
NEMA 2 - 4
WIRING DIAGRAM
TO SUPPLY
L3
L1 L2
TO SUPPLY
L3
L2
L1
CONTROL FUSES
(OPTIONAL)
3
5
V
FOR
7
W
6
1
V REV W
CONTROL FUSES
(OPTIONAL)
4
ESP200
95 96
97 98
A3+ A4-
A
XF
B
C
T1
T2
T3
V
CONTROL
TRANSFORMER
(OPTIONAL)
96
1
2
SEC FUSE
H4
FOR
T1
T2
V
2
7
XF
C
T3
A
B
MOTOR
3 PHASE REVERSING
MAGNETIC STARTER
L2
3 PHASE REVERSING
MAGNETIC STARTER
Size 5–6
L3
"REV"
CONTACTOR
"FWD"
"FWD"
CONTACTOR
CONTRACTOR
17
MECHANICAL
CONTROL
PRODUCTS
INTERLOCK
O.L.
RELAY
CURRENT
TRANSFORMER
(SEE TABLE)
REMOVE WIRE "C" IF THE CONTACTOR
COIL IS TO OPERATE ON A VOLTAGE
OTHER THAN LINE VOLTAGE OR ON A
SEPARATE CONTROL SOURCE.
MOTOR
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
X1
H2
X2
H1
ESP200
X2
TO SUPPLY
SEC FUSE
H4
SEC
95 96
97 98
A3+ A4-
MAY BE
GROUNDED BY
CUSTOMER
L1
96 CONTROL
TRANSFORMER
(OPTIONAL)
1
W
4
6
H1
T1 MOTOR T3
17-148
REV
H3
H2
H3
W
X1
SEC
T2
NEMA & General
Purpose Control
5
3
1
MAY BE
GROUNDED BY
CUSTOMER
Two Speed Heavy Duty Starters
Class 30 & 32 Non-Combination and Combination Starters
Wiring Diagrams
1 Winding Constant Horsepower Size 0–13/4
ELEMENTARY DIAGRAM
TO SUPPLY
L1
L2
DISCONNECT or
CIRCUIT BREAKER
DISCONNECT or
CIRCUIT BREAKER
HIGH
OL
HIGH HIGH
LOW
HIGH
LOW
5
T6
T4
T4
T2
LOW
T3
V LOW W
T1
T5
6 5
95
2
T2
CONSTANT HORSEPOWER
MOTOR
3
6 LOW
HIGH
5
4
B
8
7 73
V LOW W
1
96
CONTROL
TRANSFORMER
(OPTIONAL)
V HIGH W
T6
7 HIGH
LOW
2
ESP200
95 96
97 98
A
OVERLOAD
A3+ RELAY
A495
96
HIGH
C 1 96
2
4
ALL OL'S
96
6
CONTROL FUSES
(OPTIONAL)
1
V HIGH W
4
T3
T1
OL
LOW LOW
B A
3
8
T5
LOW
A
NEMA 00 - 1 3 4
WIRING
DIAGRAM
WIRING
DIAGRAM
SUPPLY
TOTOSUPPLY
L1L1 L2L2 L3L3
L3
8
T1
T2
T1
T2
X1
OVERLOAD
RELAY
A3+ A495
96
T3
T3
SEC FUSE
CONTROL FUSES
XF
(OPTIONAL)
H4
ESP200
95 96
97 98
T6
T6
T4
T4
C H2
CONTROL TRANSFORMER
SEC
(OPTIONAL)
SEC FUSE H3
X2
XF
H4
X1
T5
T5
H1
LOW
H2
T1
T2T1
T3T2
T4T3 MOTOR
M
T5T4
T6T5
POSITION L1 L2 L3 TOGETHER
LOW SPEED T1 T2 T3 T4 T5 T6
HIGH SPEED T6 T4 T5
SEC
MAY BE
GROUNDED BY
X2
CUSTOMER
H3
H1
T6
2 SPEED 3 PHASE 1 WINDING
CONSTANT HORSEPOWER
1 Winding Constant Horsepower Size 2–4
NEMA 2 - 4
WIRING DIAGRAM
TO SUPPLY
L1 L2 L3
1
V LOW W
CONTROL FUSES
(OPTIONAL)
3
6
VHIGHW
V L W
4
2
6
A
96
T4
T5
XF
ESP200
95 96
97 98
A3+ A4-
T2
1
CONTROL
TRANSFORMER
(OPTIONAL)
T6
T1
B
7
ESP200
95 96
97 98
NEMA & General
Purpose Control
5
C
A3+ A4-
SEC FUSE
H4
X1
H2
SEC
T3
H3
X2
H1
17
MAY BE
GROUNDED BY
CUSTOMER
MOTOR
CONTROL
PRODUCTS
T1
T2
T3
T4
T5
T6
2 SPEED 3 PHASE 1 WINDING
CONSTANT HORSEPOWER
1 Winding Constant or Variable Torque Size 0–13/4
ELEMENTARY DIAGRAM
TO SUPPLY
L1
L2
DISCONNECT or
CIRCUIT BREAKER
LOW
LOW
HIGH
HIGH
HIGH
ALL OL'S
T3
T4
HIGH
96
T2
T6
OL
HIGH HIGH
A
T1
T5
95
2
4
POSITION L1 L2 L3 TOGETHER
LOW SPEED T1 T2 T3
HIGH SPEED T6 T4 T5 T1 T2 T3
LOW
HIGH
5
T3
T1
T2
T5
T6
VARIABLE TORQUE MOTOR
3 HIGH 6
5 LOW 7
3
8
T1
T2
T5
T6
CONSTANT TORQUE MOTOR
T4
T3
NEMA 00 - 1 3 4
DISCONNECT or
CIRCUIT BREAKER
T4
OL
LOW LOW
WIRING
DIAGRAM
WIRING
DIAGRAM
TO SUPPLY
TO SUPPLY
L1 L1 L2 L2 L3 L3
L3
LOW
HIGH
8
V HIGH W
7 73
V HIGH W
4
2
ESP200
95 96 RELAY
97 98
OVERLOAD
95
CONTROL FUSES
(OPTIONAL)
V LOW W
4
6 5 6
B A
1
A
A3+ A496
B
8
V LOW W
C 1 96
2
ESP200
95 96
97 98
OVERLOAD
RELAY
95 A3+ A4- 96
T1 T1T2 T2
T6T6 T4T4 T5T5
T1
T1
T2
T2
T3
T3 MOTOR
T4
T4
M
T5
T5
T6
T6
1
T3
T3
96
CONTROL
TRANSFORMER
(OPTIONAL)
CONTROL SEC
FUSESFUSE
(OPTIONAL)
XF
H4
X1
C H2TRANSFORMER
CONTROL
(OPTIONAL) SEC
SEC FUSE
H3
XF
X2
H4
X1
H2
H1
SEC
MAY BE
H3
X2
GROUNDED
BY
H1 CUSTOMER
2 SPEED 3 PHASE 1 WINDING
CONSTANT OR VARIABLE TORQUE
Note: For separate control voltage source, remove jumpers “A” and “B” and connect source to control fuse terminal. Remove jumper “C” if control transformer is used.
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
17-149
Two Speed Heavy Duty Starters
Class 30 & 32 Non-Combination and Combination Starters
Wiring Diagrams
1 Winding Constant or Variable Torque Size 2–4
ELEMENTARY DIAGRAM
TO SUPPLY
L1 L2 L3
DISCONNECT or
CIRCUIT BREAKER
LOW
H
H
LOW
H
HIGH
T3
6
LOW
5 LOW 7
4
HIGH
H
LOW
V LOW W
ESP200
95 96
97 98
A3+ A4-
A3+ A4-
T6
T4
T2
T3
C
H4
X1
H2
SEC
H3
X2
V HI W
H1
T6 T4
4
SEC FUSE
XF
T5
5
HIGH
96
CONTROL
TRANSFORMER
(OPTIONAL)
T1
ESP200
95 96
97 98
H
1
7
A
8
B
V H W
T1 T2 2T3
OVERLOAD RELAY
95
96
POSITION L1 L2 L3 TOGETHER
LOW SPEED T1 T2 T3
HIGH SPEED T6 T4 T5 T1 T2 T3
NEMA & General
Purpose Control
6
3
6
CONTROL FUSES
(OPTIONAL)
3
8
V H W
1
2 7
4
T2
T5
T6
VARIABLE TORQUE MOTOR
3 HIGH H
2
V LO W
T1
T3
5
V HIGHW
T4
T5
95
1
T2
T5
T6
CONSTANT TORQUE MOTOR
ALL OL'S
96
T1
T3
T2
T4
HIGH
A B
T1
T6
OL
HIGH HIGH
NEMA 2 - 4
WIRING DIAGRAM
WIRING DIAGRAM
CIRCUIT BREAKER
T4
OL
LOW LOW
A
TO SUPPLY
L1 L2 L3
TO SUPPLY
L1 L2
L3
DISCONNECT
or
T5
T1
T2
T3
T4
T5
T6
OVERLOAD RELAY
95
96
CONTROL FUSES
(OPTIONAL)
1 96
C
MOTOR
H2
T1
T2
T3
T4
T5
T6
MAY BE
GROUNDED BY
CUSTOMER
SEC FUSE
XF
H4
X1
SEC
H3
2 SPEED 3 PHASE
1X2 WINDING
MOTOR
H1
CONSTANT
OR VARIABLE
TORQUE
D68784002
CONTROL TRANSFORMER
(OPTIONAL)
2 Winding Constant Horsepower & 2 Winding Constant or Variable Torque Size 0–4
17
TO SUPPLY
L1 L2 L3
CONTROL
PRODUCTS
L3
WIRING DIAGRAM
DISCONNECT or
CIRCUIT BREAKER
DISCONNECT or
CIRCUIT BREAKER
LOW
LOW
HIGH
HIGH
POSITION L1 L2 L3
LOW SPEED T1 T2 T3
HIGH SPEED T11 T12 T13
V HI
2
T3
T12
W
B
4
8
5 6
V HIGH W
37
V LOW W
T12
T13
ALL OL'S
95
V LO W
T1
1
96
T11
OL
HIGH
HIGH
96
CONTROL FUSES
(OPTIONAL)
B A
1
8
T2
T3
5
3
T2
T1
OL
LOW
LOW
A
L2
TO SUPPLY
L1 L2 L3
NEMA 2 - 4
WIRING DIAGRAM
TO SUPPLY
L1
ELEMENTARY DIAGRAM
2 6
T1 T2 T3
ESP200
OVERLOAD
RELAY
95 96
97 98
95
96
T11
T13
TWO WINDING MOTOR
7
A
A3+ A4-
5 LOW 6
4
HIGH
3 HIGH 7
2
LOW
HIGH
4
SEC FUSE
C 1 96
CONTROL FUSES
XF
(OPTIONAL) H4
T11 T12 T13
ESP200
OVERLOAD
RELAY
95 96
97 98
95
96
CONTROLCTRANSFORMER
H2
(OPTIONAL)
A3+ A4-
8
T1
T2
T3
LOW
T11
T1
T2
T1
T3
T11
T2
T12
T3
T13
T11
T12
T13
T12
T13
XF
SEC FUSE
H3
H4
X1
H2
M
MOTOR
CONTROL
TRANSFORMER
(OPTIONAL)
H3
H1
SEC
X1
SEC
X2
H1
X2 MAY BE
GROUNDED BY
CUSTOMER
2 SPEED 3 PHASE 2 WINDING
SEPARATE WINDING
D68786001
Note: For separate control voltage source, remove jumpers “A” and “B” and connect source to control fuse terminal. Remove jumper “C” if control transformer is used.
17-150
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
Reduced Voltage Starters & Pump Panels
Class 36, 37, 88
Wiring Diagrams
Part Winding
NEMA & General
Purpose Control
17
CONTROL
PRODUCTS
EMT
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
17-151
Reduced Voltage Starters & Pump Panels
Class 36, 37, 88
Wiring Diagrams
Auto Transformer
TO SUPPLY
L1 L2 L3
SEK
SES
SAW
LMB
SEK
SES
SAW
LMB
SEK
SES
SAW
LMB
OPTIONAL
DISCONNECT
OR
CIRCUIT BREAKER
OL
1S
3L1
0%
50%
1L1
R
65%
1CT
80%
2S
L2 L3
100%
L1
T1
2L1
OL
0%
50%
65%
80%
R
1S
3L2
1L2
100%
2S
2CT
*
T2
2L2
FOR MOTOR
HP SEE
CONTROLLER
NAMEPLATE
MOTOR
OL
4FU
71
MR
73
1S
0%
50%
65%
3L3
80%
R
FOR STARTER
SIZES 1-4, 1CT-3CT
ARE NOT USED.
L1
1L3
100%
2S
3CT
T3
2L3
1S
74
(A1)
R
75
(A2)
2S
76
MR
5FU
72
L2
2S
77
CR1
L1
JUMPER
1FU
12
TAS
1
2FU
78
(A1)
*
1S
79
H1
(A1)
H4
(A2)
1S
MECH
INTLK
(A2)
R
3FU
L2
CPT
X2
X1
CONNECT
VOLTAGE
AS SPECIFIED
PER NAMEPLATE
NOTE E
17
2
3
2
LMB
SAW
SES
SEK
1
X2
TR
SUPPLIED AS REQUIRED
3
(A1)
LMB
SAW
SES
SEK
NEMA & General
Purpose Control
CR1
MR
(A2)
4
(95)
OL
(96)
3
MR
TR
6
(A1)
CR1
(A2)
CONTROL
PRODUCTS
NOTC
CONNECTIONS FOR OPTIONAL DEVICES
Note E:
Remove jumper if thermal protection switch is provided.
HAND
*
3
1PB
OFF
AUTO
(A1)
(A2)
2PB
(A1)
START
CR2
(A2)
3
2
2PB
1SS
HAND
1
2
1
1
*
SURGE SUPPRESSOR
START
STOP
1
OFF
*
5
AUTO
CONTACT
3
1
RUN/ON/
RUNNING
3
3
1SS
*
5
OFF
1
AUTO
CONTACT
4
ETM
AUTO
4
1LT
OL
OL TRIPPED
9
X2
MR
OFF/STOP
10
X2
1
4LT
ON
1SS
*
3
1
5LT
OPTIONAL DEVICES ARE FURNISHED PER CONTRACT DOCUMENTS
17-152
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
Reduced Voltage Starters & Pump Panels
Class 36, 37, 88
Wiring Diagrams
Wye Delta (Open Transition)
TO SUPPLY
L1 L2 L3
OPTIONAL
DISCONNECT
OR
CIRCUIT BREAKER
OL
1L1
1M
T1
2M
T6
1M
T2
T1
1CT
T6
OL
1L2
S
2CT
2M
T1
T6
T2
S
S
T3
T4
T4
S
T4
T5
T5
OL
1M
1L3
T2
T3
T3
3CT
2M
T5
FOR STARTER
SIZES 1-4, 1CT-3CT
ARE NOT USED.
1L1
1L2
4FU
50
MR
2M
51
S
CR1
52
53
S
56
(A1)
57
1M
54
(A2)
S
MR
*
(A1)
5FU
MECH
(A2)
2M
(A1)
55
INTERLOCK
(A2)
NEMA & General
Purpose Control
1M
SUPPLIED AS REQUIRED
3FU
2FU
H1
1FU
1
H3 H2
H4
CPT
1X1
X2
X1
CONNECT
VOLTAGE
AS SPECIFIED
PER NAMEPLATE
X2
TR
1
2
3
2
MR
(A1)
4
(A2)
MR
TR
3
(95)
OL
(A1)
6
X2
(96)
(A2)
17
CR1
NCTO
CONTROL
PRODUCTS
CONNECTIONS FOR OPTIONAL DEVICES
2
3
CR2
(A2)
3
2PB
1
1SS
HAND
*
(A2)
(A1)
START
2
1
(A1)
2PB
1PB
OFF
HAND
AUTO
*
SURGE SUPPRESSOR
START
STOP
1
OFF
*
5
AUTO
CONTACT
3
1
4
ETM
AUTO
RUN/ON/
RUNNING
3
3
4
1LT
AUTO
1
1SS
*
5 CONTACT
OFF
1
OL
OL TRIPPED
9
X2
MR
OFF/STOP
10
X2
1
4LT
ON
1SS
*
3
1
5LT
OPTIONAL DEVICES ARE FURNISHED PER CONTRACT DOCUMENTS
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
17-153
Reduced Voltage Starters & Pump Panels
Class 36, 37, 88
Wiring Diagrams
Wye Delta (Closed Transition)
TO SUPPLY
L1 L2 L3
OPTIONAL
DISCONNECT
OR
CIRCUIT BREAKER
OL
1M
T1
T1
1CT
1L1
3L1
RES A
1A
2M
T6
OL
1M
1L2
2CT
3L2
RES B
T1
T6
T2
T2
S
1A
2M
S
S
T3
T4
S
T4
T5
T5
OL
1L3
1M
T3
T3
3CT
3L3
RES C
2M
T2
1A
FOR STARTER
SIZES 1-4, 1CT-3CT
ARE NOT USED.
1L2
1L1
4FU
50
MR
2M
51
CR1
52
53
1A
NEMA & General
Purpose Control
S
S
57
(A1)
1A
56
(A1)
58
(A1)
(A2)
MR
54
2M
(A1)
5FU
(A2)
S
*
1M
55
1M
MECH
(A2)
INTERLOCK
(A2)
SUPPLIED AS REQUIRED
3FU
2FU
H1
1FU
1
H3 H2
H4
CPT
1X1
X1
X2
TR
6
CONNECT
VOLTAGE
AS SPECIFIED
PER NAMEPLATE
X2
(A1)
(A2)
CR1
NCTO
TR
17
1
3
2
CONTROL
PRODUCTS
2
MR
(A1)
MR
4
(A2)
OL
(95)
(96)
X2
3
CONNECTIONS FOR OPTIONAL DEVICES
2
3
1PB
OFF
HAND
AUTO
*
(A2)
START
(A1)
CR2
(A2)
3
2PB
1SS
HAND
1
(A1)
2PB
2
1
1
*
SURGE SUPPRESSOR
START
STOP
1
OFF
*
5
AUTO
CONTACT
3
1
RUN/ON/
RUNNING
3
3
1SS
*
5
OFF
1
AUTO
CONTACT
4
ETM
AUTO
4
1LT
OL
OL TRIPPED
9
X2
MR
OFF/STOP
10
X2
1
4LT
ON
1SS
*
3
1
5LT
OPTIONAL DEVICES ARE FURNISHED PER CONTRACT DOCUMENTS
17-154
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
Heavy Duty Contactors and Reversing Contactors
Class 40, 43
Wiring Diagrams
3-Phase Magnetic Contactors and Reversing Contactors
3-Phase Contactors—Size 00–4
3-Phase Reversing Contactors—Size 00–4
3-Phase Contactors—Size 5, 6
3-Phase Reversing Contactors—Size 5, 6
TO SUPPLY
L1
L2
L3
"REV"
CONTACTOR
"FWD"
"FWD"
CONTACTOR
CONTRACTOR
MECHANICAL
NEMA & General
Purpose Control
INTERLOCK
RELAY
CURRENT
TRANSFORMER
REMOVE WIRE "C" IF THE CONTACTOR
COIL IS TO OPERATE ON A VOLTAGE
OTHER THAN LINE VOLTAGE OR ON A
SEPARATE CONTROL SOURCE.
17
LOAD
CONTROL
PRODUCTS
Single Phase Magnetic Contactors and Reversing Contactors
Single Phase Contactors—Size 00–4
Single Phase Reversing Contactors—Size 00–1P
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
17-155
Duplex Heavy Duty Controllers
Class 83, 84
CONTROL
PRODUCTS
17
NEMA & General
Purpose Control
Standard Duplex Pump Panel (92)
17-156
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
Wiring Diagrams
Duplex Panel w/o alternator (95)
Duplex Heavy Duty Controllers
Class 83, 84
Duplex Panel with Relay Alternation (93)
Wiring Diagrams
Duplex Panel with Lead Pump Transfer Switch (94)
NEMA & General
Purpose Control
17
CONTROL
PRODUCTS
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
17-157
Standard & Irrigation Pump Panels
Class 87
CONTROL
PRODUCTS
17
NEMA & General
Purpose Control
Standard Class 87 Pump Panel
17-158
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
Wiring Diagrams
Lighting and Heating Contactors
Electrically Held, Class LE
Wiring Diagrams
20 AMP
30 – 100 AMP
NEMA & General
Purpose Control
17
CONTROL
PRODUCTS
200 – 400 AMP
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
17-159
Lighting and Heating Contactors
Mechanically Latched 20 Amp, Class CLM
ON
Wiring Diagrams
OFF
CONTACTOR CONTROL
VOLTAGE
L
OFF
L
ON
C
COMMON OR SEPARATE
CONTROL LINES
5
ON
2
CR1
3
CR2
L
CR2
CR1
0
CR1
CR2
C
ON
0
OFF
CONTROL
MODULE
VOLTAGE
OFF
4
TYPICAL OFF-ON
SELECTOR SWITCH
COIL
PILOT LIGHTS
REQUIRE (1) EA.
CLM4097291
AUXILIARY
CONTACT KIT.
3 WIRE CONTROL ACC. 48
ON
CONTACTOR CONTROL
VOLTAGE
HAND
OFF
AUTO
OFF
5
CONTROL
MODULE
VOLTAGE
CR
CR
4
3
OFF
L
CR
3
COIL
REMOTE
CONTROL
2
CONTROL
MODULE
VOLTAGE
CR1
CR2
CONNECTIONS TO CONTROL MODULES
OFF
1
L
NEMA & General
Purpose Control
CR
C
3
CR
4
MODULE
TERMINAL
L
ON-OFF
CONTROL
MODULE
VOLTAGE
COIL
ON
2 WIRE CONTROL ACC. 47
CONNECT TO:
NOT USED
2
CONT. STATION FOR ACC. 48 & 49
3
CONT. STATION FOR ACC. 47,48 & 49
4
MODULE CONTROL VOLTAGE *
5
CONTACTOR CONTROL VOLTAGE
O
" CONTACTOR
"
TERMINAL O ON
C
" CONTACTOR
"
TERMINAL C ON
CONTROL
PRODUCTS
17
* FOR 24 VDC CONTROL MODULES
CONNECT TERMINAL 4 TO NEGATIVE (-)
17-160
CR1
C
ON-OFF (FORM 3) CONTROL ACC. 49
CONTACTOR CONTROL
VOLTAGE
0
0
COIL
ON
ON
CR
L
CR1
4
2 WIRE CONTROL ACC. 47
5
OFF
5
CR2
0
C
L
CONTACTOR CONTROL
VOLTAGE
L
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
Lighting and Heating Contactors
Mechanically Latched 30–400 Amps, Class CLM
Mechanically Latched, CLM 30–200
Wiring Diagrams
Ampsa
Connection for 2-Wire Control CLMOC,
CLMOD, CLMOE, and CLMOF
Connection for Hand/Off/Auto Control
CLMOC, CLMOD, CLMOE, and CLMOF
NEMA & General
Purpose Control
Connection Diagram for Common/Separate
Control with Momentary Pushbutton or
ON-OFF Selector Switch CLMOC, CLMOD,
CLMOE, and CLMOF
Mechanically Latched Type CLM 300 and 400 Ampa
17
CONTROL
PRODUCTS
Connection Diagram for Common/Separate
Control with Momentary Pushbutton or
ON-OFF Selector Switch CLMOG and
CLMOH
Connection for 2-Wire Control CLMOG and
CLMOH
Connection for Hand/Off/Auto Control
CLMOG and CLMOH
a Control
relay is required for 2-wire and Hand/Off/Auto
Control, as shown in diagram.
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
17-161
Industrial Control Power Transformers
Class MT, MTG
Voltage Letter
Aac
When secondary fuse clips are installed,
Terminal X1 becomes XF
Voltage Letter
Db
CONTROL
PRODUCTS
17
NEMA & General
Purpose Control
Wiring Diagrams
Voltage Letter
B bc
When secondary fuse clips are installed,
Terminal X1 becomes XF
Voltage Letter
E ac
Voltage Letter
C bc
When secondary fuse clips are
installed, Terminal X1 becomes XF
Voltage Letter
Fa
When secondary fuse clips are
installed, Terminal X1 becomes XF
When secondary fuse clips are installed,
Terminal X1 becomes XF
When secondary fuse clips are installed,
Terminal X1 becomes XF
Voltage Letter
Ga
Voltage Letter
H
Voltage Letter
I
When secondary fuse clips are installed,
Terminal X1 becomes XF
Does not include secondary fuse clips
Does not include secondary fuse
clips
Voltage Letter
J bc
Voltage Letter
L
When secondary fuse clips are installed,
Terminal X3 becomes XF
Does not include secondary fuse clips
H1
a
b
c
Includes secondary fuse clips on sizes 50-750VA
Includes secondary fuse clips on sizes 50-500VA
Secondary fuse clips are not included on MTG
transformers.
17-162
X2
Voltage Letter
P
380V
24V
H2
X1
Does not include secondary fuse clips
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
Voltage Letter
Ma
When secondary fuse clips are
installed, Terminal X1 becomes XF